Product Information UV3000 Multi-gas Stack/Process Monitor System
|
|
|
- Earl Short
- 9 years ago
- Views:
Transcription
1 Cerex Monitoring Solutions, LLC Briarwood Industrial Court, Suite D, Atlanta, GA (678) phone; (404) fax; web Product Information UV3000 Multi-gas Stack/Process Monitor System Cerex Monitoring Solutions is pleased to submit the following technical information for our UV3000 Stack Gas Analyzer. The system is available to meet a variety of stack monitoring methods, ranging from extractive, to in-situ, utilizing optical methods of gas detection. For process monitoring, a closed cell is used, and either process pressure, or a pump is used to transport the sample into the optical cell. Many clients, including industry, researchers, University, and EPA have a requirement to perform a wide array of air monitoring projects. The applications might include ambient monitoring, stack monitoring, process monitoring, on a fixed or mobile platform. The clients usually end up purchasing several sets of expensive equipment, just to enable their capability to meet these varied project needs. The Cerex UV3000 system is designed with the flexibility to accommodate these needs within a single analyzer. The construction and features of the UV3000 system are such that a single, core system, coupled with modular sampling accessories, allows multiple applications to be explored without having to purchase multiple monitoring systems. Cerex has developed two technologies that allow this to be possible. UV spectrophotometer hardware and software allow multi-gas measuring flexibility. Second, Cerex has perfected multipass, long-path gas cells that provide for very low minimum detection capabilities; often down to parts per trillion or low ppb levels. When attempting to match a monitor to an application, a primary issue is the concentration range of the gases that will be detected. In ambient applications, the concentration limits usually begin in low ppb levels. Stack monitoring applications typically can have gas concentrations ranging from ppm even up to pp-thousand, or even percent levels. Process applications can span the entire range. The Cerex UV3 monitor allows the user to adapt to these various concentration levels by selectively varying the pathlength of the UV beam that intercepts the gas stream. In the case of ambient gases, the pathlength of 30meters or more is used. We gain this path by utilizing a multipass cell.
2 For short path, stack or process applications, we utilize a short path multipass cell, or even a single pass cell ranging in the length of centimeters. Cerex has developed our analyzer system such that various cells are plug and play and coupled to the main analyzer via fiber optic cables. This enables the user to customize the system to his specific project application needs. Summary of UV3000 Features High Resolution 2048 element UV spectrometer Operates on principle of UV/Vis DOAS Stabilized UV Source (Deuterium or Xenon) Continuous, Real-Time Concentration Data Raw Data is Logged Easy On-Site Calibration Checks Stack Extractive options allow paths from 1cm to 30+meters Cross-Stack, In-Situ method is offered In-Stack In-Situ method is offered Gas concentrations from pptrillion to percent Optional Alarm outputs (trip-level is user selectable in software) Optional 4-20 ma outputs corresponding to measuring range Long-life deuterium UV Source (guaranteed 2000 hours, 4000 typical) Fiber optic-coupled, Temperature stabilized UV Source Cell or other Probe connected to main analyzer using only fiber optic Advanced real-time software utilizing CLS or optional PLS External laptop connects to analyzer via USB Or user can select a internal Single Board Controller (SBC) Optional local display on the analyzer case Automatically takes clean air backgrounds (auto re-zero function) Internet/wireless connectivity Operation in extreme temperatures with optional heating/cooling package Optional Thermostatically controlled heated Cell to eliminate condensation effect Provided with the capability of the full Cerex UV library of compounds Sample cell can be remoted to keep personnel away from hazardous gases. UV3000 Main Analyzer The system is separated into two parts, the primary UV3000 analyzer, and the optical probe. This probe can be a closed cell, or an open path optical system. The optical half of the system connects to the primary analyzer via optical cabling. Therefore, if the user elects to remote the optical half in a separate area, this entire half of the system is now intrinsically-safe. The main analyzer is available in a 19-inch rackmount enclosure, or an optional outdoor-rated NEMA enclosure. Cerex Reference Spectra Each Cerex system comes standard with our core group of compounds. There is no need to pay extra to monitor for additional compounds. Please see the attached Appendix A for a sample listing of core compounds provided, and also a statement on detection limits.
3 Create New Reference Spectra Onsite Using the standard Short Path Linear Flow Cell, the user can create certified library references onsite, without the need to purchase these from Cerex or another outside source. This is typically accomplished via 3 methods; Obtain a cylinder of target gas containing a certified concentration (lab analysis) Dilute a liquid sample into a known volume of carrier gas Obtain a standard, certified permeation tube, and use these with a calibrated oven. The quantitative sample is flowed into the stabilized cell of known pathlength. From this the absorption spectra is acquired and saved in a format that is compatible with the Cerex CMS real-time analysis software. UV Light Source The main UV3000 Analyzer is available with a choice of light sources. UV3000-X Xenon- A more powerful beam that allows for longer paths, or paths heavy in particulate matter. The downside is that there is a subset of deep-uv absorbing compounds that may not be available UV3000-D Deuterium A less powerful optical beam, but enables monitoring of several deep-uv compounds, including H2S. See separate Cerex document for details on uv source intercomparison. Enclosure The UV3000 primary analyzer comes standard built into a 19 rack-mount enclosure. A variety of other enclosure options are available to accommodate a variety of environments. These range from sealed enclosures that are suitable for mounting in outdoor environments, including hazardous locations. The Cell accessory options are also available mounted in enclosures, or sold individually for use in customerdetermined applications, including research and general laboratory use. Stack Monitoring Options Gnerally, the Cerex UV3000 has the ability to accommodate 3 types of Stack Sampling Scenarios; A single UV3000 system has the capability to adapt to each of these 3 scenarios with the purchase of optional sampling equipment. In addition to stack sampling, the system can then easily be adapted to process monitoring, or even ambient (closed or open path) monitoring. Extractive - In this method, the gas sample is removed from the stack and transported to the analyzer for analysis. However, in most cases some conditioning of the sample is required to remove water vapor and particulate matter. A variety of different pathlength cells are available, and the selection of what cell to use is a function of the gas and concentration range found in the stack. In the case of Cerex Cells, each of these opto/mechanical assemblies is fiber-optically linked to the main UV3000 analyzer. Cross Stack This method represents a form of in-situ monitoring, as the sample never leaves the stack. In effect, this is also remote sensing, because the sample never touches any sampling apparatus. An optical beam passes across the stack diameter, and that optical beam is the absorption path which enables the analysis.
4 In-Situ A gas probe is inserted into the wall of the stack. An optical beam is contained within the probe. This optical beam represents the absorption path which enables the analysis. The sample is drawn into the probe, but remains at the conditions found in the stack. The sample is never removed or extracted from the stack. In each case, the UV3000 connects via fiber optic to the opto-mechanical hardware that is utilized under each method. The gas absorption is monitored, and continuous, real-time indications of concentration are reported and logged. Next we will describe the specific options that are available with each stack monitoring method; EXTRACTIVE Short Path Linear Flow-Through Cells The Cerex Short Path linear cells are designed with several unique features that make them very user-friendly in applications that require flexibility in pathlength; Cells are offered in a wide variety of materials to adapt in harsh chemical or temperature conditions Cells easily disassemble in the event cleaning is required The path length is User-Selectable. The center section of the cell is constructed of standard stainless-steel pipe with standard NPT threads. Any standard pipe nipple can be used as the body of the cell. This enables the user to choose any standard off-the-shelf size, or even create a custom-length cell. Heater can easily be added Paths of up to 1.5 meter are recommended (using Xenon) Paths of up to 0.5 meters are recommended (using D2) Standard Compression fittings for Gas Inlet and Outlet (10cm) Fiber Optically Coupled 10-Centimeter path Flow Cell General Purpose, Light Duty Long Path Multipass Cells 5 meter path Low volume Gas inlet and outlet valves are shown on the right side of the cell. The left side of the cell supports the optical input and output ports.
5 20 meter path Larger Volume Shown right are the relative size comparisons of the 20 meter cell, 5 meter cell, and UV3000 Primary Analyzer built into the 19 Rackmount Configuration. Cerex UV3000 Analyzer Shown Configured in an outdoor NEMA enclosure. Cerex UV3000 Analyzer Internal View.
6 Cerex UV3000 Analyzer 10-Meter Multipass Cell Complete with Heating and Enclosure. Extractive Probe, with complete Sample Conditioning Specifications are attached in a separate document found under appendix B. The SPP-100 system comes complete with a sample extraction probe, and all of the hardware required to condition the stack sample prior to the gas entering the gas Cell for analysis. SPP-100 Sample Extraction System with Conditioning
7 Cross-Stack Monitoring Optical System Shown above The optical telescope head used in the cross-stack method of the UV3000 stack analyzer The cross stack optical system is typically built custom for every application. This is due to the fact that the diameter of the stack at the measuring height is different in every case. In addition the available size of the access port also is a limitation in some applications. The concentration of measurable gases within the stack also determine whether the optical pathlength achieved by the system is indeed large enough to allow enough absorption to detect the compounds at the required minimum detectable limit (MDL). In addition, if the concentrations range very high, and the path is too long, then so much absorption could occur that certain spectral regions of analysis could be rendered useless due to complete loss of available uv light. Monostatic system The monostatic configuration consists of a Transmitter and Receiver located side-by-side. The beam path is completed at the opposite end of the stack with a retro-reflector or mirrored transfer optic. This design offers the following benefits; Double path through the stack achieves lower detections of gases Only a reflector is required at one end of the path easier installation details Bistatic System The bistatic configuration consists of a Transmitter located at one end of the path, and the Receiver located at the opposite end. The beam passes through the sample one time In both designed, the optical system is fiber-optically coupled to the main UV3000 analyzer. Depending on the gases to be analyzed, and the amount of particulates within the stack, the appropriate UV source (Deuterium or Xenon) is chosen. Xenon has the benefit of higher optical power to cut through heavy particulate scattering. Deuterium has the benefit of enabling the monitoring of the deep-uv subset of compounds. For the purposes of this proposal, the two optional optical systems are simply identified as Cross Stack Short Path and Cross-Stack Long Path. P/N Cross Stack Short Path Used on Stacks of 1 meter diameter or less Available in monostatic or bistatic optical designs Please specify length of fiber to interconnect the optics and main UV3000 analyzer
8 P/N Cross Stack Long Path Used on stacks with diameter greater than 1 meter. Available in monostatic or bistatic designs Please specify length of fiber to interconnect the optics and main UV3000 analyzer In-Situ Stack Probe In Situ Probes are normally custom-specified and priced according to the effective pathlength of the probe. The concentration of measurable gases within the stack determine whether the optical pathlength achieved by the system is indeed large enough to allow enough absorption to detect the compounds at the required minimum detectable limit (MDL). In addition, if the concentrations range very high, and the path is too long, then so much absorption could occur that certain spectral regions of analysis could be rendered useless due to complete loss of available uv light. Shown Left The in-situ probe has a maximum pathlength of 2 meters. (Physical length is 1 meter). Sections of the probe can be removed to reduce the pathlength for higherconcentration gas sampling In-Situ probes are available in a variety of paths ranging from a few millimeters up to 2 meters. Each probe is fiber-optically coupled back to the primary UV3000 Analyzer Most models that we offer have the provision built-in to inject a zero gas or calibration gas ahead of the sample stream Probes up to pathlength of 20mm Probes from 20mm up to 1 meter
9 Extractive Probe, with complete Sample Conditioning Specifications are attached in a separate document. The SPP-100 system comes complete with a sample extraction probe, and all of the hardware required to condition the stack sample prior to the gas entering the gas Cell for analysis. SPP-100 Sample Extraction System with Conditioning Computer Controller and Software The UV3000 is provided with a computer controller. Two options are available, and the customer should specific which at the time of order; External Laptop PC.- The UV3000 connects to the laptop via USB connection. Internal Single Board Controller (SBC) The single board controller handles all the real time monitoring, data collection and archiving. The customer communicates and controls the UV3000 via a wireless or Ethernet link from another local PC or laptop (remote desktop connection). In the case that the SBC option is chosen, then Cerex also offers an optional LCD display that is front-mounted on the enclosure. The display provides the same visual information that is available on the laptop screen. CMS Cerex Continuous Monitoring Software and Data Logging
10 The CMS software is provided in several modules; Instrumentation Control This provides the interface with the basic spectrometer data acquisition controls Averaging Data Output Rate Alarms Real Time Monitor Numerical concentration output for each of the compounds that have been user-selected Numerical representation of data quality. Each concentration result has this data-confidence attached Monitor of system light throughput, updated with each measurement Trend Chart with choice of all chemicals shown, or a user-selected subset Smart-QA Software * Software applet that guides the user through a simple, calibration verification utilizing the Cerex sealed calibration cells. Raw Spectral Data is Saved Raw Single-Beam Intensity Spectra Data Summary file containing a complete log of o Time and date stamp o Concentration value for each individual gas chosen o Data quality value for each measurement o Record of signal strength o Record of what background file was utilized in the analysis to create the reported concentration Post Processing Module Reprocess with an alternate background Reprocess to locate additional chemicals Graphic/Report Summary Tools * One-click data summary chart creator Library Reference Generator * Allows user-selection of spectral analysis regions * Important when configuring the analysis for mixtures of gases Algorithms CLS Included in the basic analysis software PLS - Offered on a custom gas-mixture basis (additional charges apply) Hardware Control Solenoid valve activation to control the injection of zero or calibration gas into the cell Auto-cal, Auto-background function
11 Calibration Generally, the calibration of the UV Spectrometer is fixed and inherent in the quality of the library reference spectrum. However, Cerex does offer the provision to challenge every configuration with a calibration gas. * Cerex offers a small sealed calibration cell that can be inserted within the uv beam path. A limited number of gases are stable, long-term in these sealed cells. Cerex recommends that these only be left in the beam path for short periods of time * For absolute calibration, Cerex offers 1 cm path flow cells that allow calibration gas from a certified cylinder to be flowed. * In the case of UV3000 systems utilizing linear, or multipass cells, provision is offered to flow a calibration gas from a certified cylinder. * In the case of UV3000 systems utilizing a in-situ probe, provision exists to flow calibration gas ahead of the stack gas. * In the case of the Cross-Stack system, a large flow-cell, with precision glass windows is provided. The cell is manually inserted into the beampath (external to the stack). Gas from a certified cylinder is flowed through the cell for verification purposes. OTHER OPTIONS Heating Option for Cells Heaters and a temperature sensor are attached to the body of the cell. A separate temperature controller is adjusted to allow the cell to maintain a fixed temperature setting. This is very useful for eliminating condensation effects from unconditioned samples. This also reduces the effect of polar molecules sticking to the internal cell walls. Please specify your desired setpoint temperature P/N Heating Option for Cells Enclosure for External Cells The cells, and optional heaters and controllers are built into a sealed steel enclosure. AC power is accessible on the outside (for heater power). 2 bulkhead fiber ports are provided as the optical interface to the internal cell Sections of fiber are also provided on the internal side of the enclosure. Bulkhead compression fittings are provided as the gas inlet and outlet ports. P/N Enclosure for External Cells
12 Fiber Optic Cables Used to connect optical sampling accessories to the main UV3000 analyzer Specify Length when ordering. Typically 2, equal length fibers are required meter meter meters meters meters Auto Purge / Background system Auto Zero / Background- We can add the option to auto-background (zero) the system. The solenoid shuts off the sample flow from the stack, and opens the valve to allow clean air (N2, O2, Factory air, Ambient air...from cylinder or local supply lines) to purge the cell. When the timing cycle of the purge is reached, then a new instrument background is taken. Afterwards, normal stack monitoring resumes. Background acquisition frequency is software selectable. POWER The system is powered by 115VAC/15A/60Hz Standard North American connection. As an option 220VAC/ 50-60Hz is also available. (Please specify at the time of ordering) Maintenance Items P/N UV Deuterium Source (replacement bulb) P/N UV Xenon Source (replacement bulb)
13 APPENDIX A Guidelines - Minimum Detection Limits for Cerex s UV3000 UV DOAS Monitor Compound Detection Limits (ppm-m)* Ammonia 1.59 Benzene Chlorine 5.0 Carbon Disulfide Napthalene Formaldehyde 3.2 Hydrogen Sulfide.500 Nitrogen Oxide (NO).34 Nitrogen Dioxide (NO2) 2.0 Ozone 2.00 o-xylene 3.77 m-xylene p-xylene Sulfur Dioxide Toluene ,3 Butadiene 0.20.and more * Currently there are a number of definitions of detection limits used to characterize the performance of air monitoring systems. A common definition of is the magnitude of the absorbance spectra that is twice the system noise. The Environmental Protection Agency s Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air - Second Edition Compendium Method TO- 16 Long-Path Open-Path Fourier Transform Infrared Monitoring Of Atmospheric Gases defines detection limits as the following: The detection limit of the UV3000 systems is a dynamic quantity that will change as the atmospheric conditions change. The variability of the target gas, and all of the other interfering species concentrations contributes to the variability of this measurement. The detection limit as determined in this procedure is the result of a calculation using a set of 15 individual absorption spectra. The 16 individual single beam spectra used for this determination are acquired in 5-min intervals and no time is allowed to elapse between them. The absorption spectra are then created by using the first and the second single beam spectra, the second and the third, and the third and the fourth, and so on until the 15 absorption spectra are obtained. These absorption spectra are analyzed in exactly the same way that all field spectra are to be analyzed and over the same wave number region. The analysis should result in a set of numbers that are very close to zero because most of the effects of the gas variability have been removed. The numerical results should be both positive and negative and for a very large set of data should average to zero. Three times the standard deviation of this calculated set of concentrations is defined to be the detection limit. Although Method TO-16 was written for open path FTIR, the Cerex UV3000 system is unique among UV systems in that the raw data is essentially identical to an FTIR Single beam file. Hence the direct correlation drawn to TO-16. Using the detection limit definition described in TO-16, CEREX developed the detection limits that are listed above However it should be noted that the actual detection limits achieved in the field will vary. This is primarily due to the fact that variations in interfering species will result in variability in detection limits. Cerex considers the detection limits listed to be a very conservative estimate. The end-user of the equipment will likely achieve much better results in the field. Cerex believes it is a good policy to not oversell a capability to our potential customers.
14 APPENDIX B Detailed Literature on the SPP-100 Sample Conditioning System
15
16
17
Sentry-MS. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific. Open Path Multi-gas UVDOAS Analyzer. Ammonia.
Sentry-MS Open Path Multi-gas UVDOAS Analyzer Ammonia Benzene Carbon Disulfide Chlorine Cost Effective Perimeter & LDAR Monitoring The Sentry-MS offers perimeter monitoring with among the lowest cost per
Advanced Solutions for Gas Monitoring
Continuous Emissions Monitoring Stack Testing Process Monitoring Quality Control Engine Exhaust Gas Monitoring Workplace Air Quality Monitoring Combustion Research Emergency Rescue Services Advanced Solutions
Trace Gas Exchange Measurements with Standard Infrared Analyzers
Practical Environmental Measurement Methods Trace Gas Exchange Measurements with Standard Infrared Analyzers Last change of document: February 23, 2007 Supervisor: Charles Robert Room no: S 4381 ph: 4352
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer
Procedure No: SOP-039 Revision No: 1.1 January 21, 2011 Page No.: 1 of 11 1. INTRODUCTION AND SCOPE This document will outline specifics with regards to portable sampling analysis utilizing and operating
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry Models UVS-1, MoniSpec-UV & MoniSpec-UVd Model UVS-1 general information
Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
The Ambient Air Monitoring System
The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters
CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: 0000037051. GM32 ln-situ-gasanalysator model Cross Duct for NO and S02
Umwelt Bundes Amt @ For our Environment A TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000037051 Certified AMS: Manufacturer: Test Institute: GM32 ln-situ-gasanalysator
Installing a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2
ENERGY RESEARCH at the University of Oulu 117 Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2 1 University of Oulu, Department
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer
LI-7000 CO /H O Analyzer 2 2 High Speed, High Precision Differential Analyzer LI-7000 CO 2 /H 2 O Analyzer - Advantages... Page 1 The LI-7000 CO 2 /H 2 O Analyzer The LI-7000 is a high performance, dual
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy
Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy UV/VIS AND UV/VIS/NIR SPECTROSCOPY A P P L I C A T I O N N O T E Introduction The availability and applications of fiber optic sampling in UV/Vis
Application Requirement
Hazardous Gas Monitors Sensor Selection Overview Safety Monitoring (LEL) Toxic Limit Detection (PEL) Leak Detection Personal Safety Application Requirement Exposure Assessment (TWA) Ambient Air Quality
Overview. Inficon s Product
A comparison between Stanford Research Systems BGA244 Binary Gas Analyzer and Inficon s Composer Elite Gas Concentration Monitor. (Compiled by Stanford Research Systems) Overview The speed of sound can
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
AUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja
Process gas chromatographs. Measurement made easy Compliance Solutions for 40CFR60 Subpart Ja Introduction ABB offers a proven analytical solution to completely meet your Refinery Flare Monitoring requirements
PortaSens ll G AS DETECTOR
PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor
DUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants
Intelligent Mould Flow Monitoring
Intelligent Mould Flow Monitoring The Mouldflo Flow Monitoring System 1 2 The Mouldflo Flow Monitoring System Mouldflo Flow Monitoring System For the first time Mouldflo offers Injection Moulders an affordable
G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method
G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace
450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer
450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 First Edition MONITORING AND LABORATORY DIVISION August
Fundamentals of Mass Flow Control
Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
RGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
Rackmount Intelligent Pressure Scanners
Rackmount Intelligent Pressure Scanners NetScanner System 9816/98RK-1 FEATURES ±0.05% Accuracy 100 Hz EU Throughput Autonegotiating 10/100/1G Base T Ethernet - TCP and UDP Protocol Pressure Ranges up to
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
REAL-TIME DUST AND AEROSOL MONITORING
REAL-TIME DUST AND AEROSOL MONITORING THE DUSTTRAK II AND DRX AEROSOL MONITORS UNDERSTANDING, ACCELERATED REAL-TIME DUST MONITORING. ANY ENVIRONMENT. ANY APPLICATION. The DustTrak II and DRX Aerosol Monitors
World s Best Oil in Water Analyzers
World s Best Oil in Water Analyzers Advanced Water Measurement and Analysis Advanced Sensors Ltd is the leading global supplier of Oil in Water analyzers to the Oil and Gas Industries. We provide innovative
AMBIENT AIR QUALITY MONITORING SYSTEM. Air Quality Monitoring... Easier. Faster. Better. www.chemtrols.com
AMBIENT AIR QUALITY MONITORING SYSTEM Air Quality Monitoring... Easier. Faster. Better. www.chemtrols.com AMBIENT AIR QUALITY MONITORING FROM CHEMTROLS Chemtrols is a leading solution provider in the field
NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: [email protected]; www.a-tech.ca
Networking Solutions NetScanner System 9IFC/90DB/90DC FEATURES Ethernet Interface for NetScanner System Modules Provides Power and Hardware Trigger Interface 10/100 Base-T Auto-Negotiating Universal AC
Fundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration
Relative Humidity Measurement and Calibration The widest range of humidity products from a pioneer of RH sensor development The best in Relative Humidity technology to optimize your process Whether you
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
General Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.
QUANTITATIVE INFRARED SPECTROSCOPY Objective: The objectives of this experiment are: (1) to learn proper sample handling procedures for acquiring infrared spectra. (2) to determine the percentage composition
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
ABSTRACT INTRODUCTION
Infrared Technology for Fail-To-Safe Hydrocarbon Gas Detection Authors: Dr. Shankar Baliga is Manager of Research & Development at General Monitors. He has a Ph.D. in Physics from Ohio State University
Process Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
Electronic faucets for every occasion, every application
Electronic Faucets Electronic Faucets Electronic faucets for every occasion, every application With above-deck electronics and other exclusive features, Chicago Faucets electronic products are an ideal
Ammonia Detection System Codes and Design Specifications
Ammonia Detection System Codes and Design Specifications December 28, 2015 Revision 5 920 N Trade Winds Pkwy Columbia, MO 65201 Ammonia detection system codes and design specifications Following is a discussion
Ultrasound Condition Monitoring
Ultrasound Condition Monitoring Whitepaper Alan Bandes UE Systems, Inc. Abstract: Instruments based on airborne/structure borne ultrasound technology offer many opportunities for reducing energy waste
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
OptiNet Applications. A Review of the Unique Requirements for a Facility Monitoring System. White Paper Series
OptiNet Applications A Review of the Unique Requirements for a Facility Monitoring System White Paper Series A Review of the Unique Requirements for a Facility Monitoring System Overview The surging cost
Page 1 of 10. MIDAC Corporation 130 McCormick Avenue, #111 Costa Mesa, CA 92626 (714) 546-4322 www.midac.com
PPM-Level HCl Measurements from Cement Kilns and Waste Incinerators by FTIR Spectroscopy Peter Zemek, PhD, Joe Van Gompel, PhD, Steven Plowman, Introduction Fourier transform infrared (FTIR) spectroscopy
Engineering Specifications XNX Universal Transmitter
Engineering Specifications XNX Universal Transmitter 1.0 General Description: The XNX Universal Transmitter is a comprehensive solution designed to operate in hazardous locations and utilize sensor technologies
Online Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS
PORTER MASS MEASUREMENT AND CONTROL SYSTEMS PORTER: THE STANDARD OF EXCELLENCE IN MASS Porter Mass Flow products reflect nearly three decades of experience in the design and manufacture of precision instruments
Emission Monitoring and Reporting (EMR) Guidelines for Continuous Emissions Measurements in Holcim Cement Plants
Emission Monitoring and Reporting (EMR) Guidelines for Continuous Emissions Measurements in Holcim Cement Plants (European Version) HGRS-CTS/MT J. Waltisberg HGRS-CIE/ETPS Th. Lang Version: 2003-02/E 20.03.2003
Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems
Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations
Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory
FIELD APPLICATION REPORT UV/Vis/NIR Spectroscopy Author: Frank Padera Shelton, CT Contributor: Chris Lynch Shelton, CT Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
DESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC
Measurement & Analytics Measurement made easy MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC MB3600 FT-NIR spectrometer for your industry
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Cooling Channel Optimization
Mouldflo Test Rig Cooling Channel Optimization Plug and Play Mould pre-set for production For the first time Mouldflo offers Mouldmakers a unique way to configurate the cooling circuits with full Benchmark
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
Analytical Instruments Smart Analyzer 90 Type SMA
Data Sheet Analytical Instruments Smart Analyzer 90 Type SMA Oxygen Only or Optional Oxygen and Combustibles Rugged Industrial Design Easy Installation and Start-up Highly Accurate Sensors Simplified In-house
How To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
Quality Assurance Program Quality Assurance Plan Periodic Audits Standard Operating Procedures Preventive Maintenance Outline Quality Assurance Plan (QAP) What is a QAP Why is a QAP required? What does
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
UVC LEDs for. Environmental Monitoring
UVC LEDs for Environmental Monitoring Environmental monitoring relies extensively on molecular spectroscopy for tracking air quality, water and wastewater quality, and detecting hazardous substances. Advances
The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO
The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
User and installation manual
User and installation manual aquaero 5 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of April 2011 ENGLISH: PAGE 1 DEUTSCH: SEITE 13
Powers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
OEM-EP Pressure Controllers
Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable
Thermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
EXPLORER 4 MULTIPOINT
EXPLORER 4 MULTIPOINT Sampling gas analyser EXPLORER 4 MULTIPOINT is a sampling gas analyser, with 4 gas detection sensors ( LEL,H2S, O2 CO ) reliable and in accordance of the Rules with 15 sampling points
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement
MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters
Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein
Air Quality Issues in the Rocky Mountain Region PM2.5 Source Testing Method 201A Determination PM 10 and PM 2.5 Emissions from Stationary Sources (Constant Sampling Rate Procedure) Method 202 Dry Impinger
The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD
TN-100 The Fundamentals of Infrared Spectroscopy The Principles of Infrared Spectroscopy Joe Van Gompel, PhD Spectroscopy is the study of the interaction of electromagnetic radiation with matter. The electromagnetic
Ron 3025 Crane Scale with 1"/25mm Display
Exceptionally small dimensions enable minimum headroom loss. For example: Height of the 5t load cell is 16.7 inch / 423 mm Optional shock absorbing protective cage Optional IR remote control Short delivery
HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED
HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed
Chlorine Gas Detection System Operation & Maintenance
Chlorine Gas Detection System Operation & Maintenance Maynard King K&D Pratt Instrumentation 2011 Clean and Safe Drinking Water Workshop Chlorine Gas Detector Operation, Maintenance, Checks 1. Why you
Streaming Potential System (SPT1000, SPD1000)
Streaming Potential System (SPT1000, SPD1000) User's Manual Sentrol Systems, Inc. 3949 Cotswold Dr. SW, Lilburn, GA 30047-2371 Tel: 770-564-1541, Fax: 770-564-8605 www.sentrolsystems.com Since the streaming
Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators
Atlas Copco On-site Industrial Gases Nitrogen & Oxygen Generators A secure supply of nitrogen and oxygen Whether your company is specialized in chemical manufacturing, electronics, laser cutting or food
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
CAMS. Combustion Airflow Management System. Proven solutions for a tough industry
CAMS Combustion Airflow Management System Proven solutions for a tough industry CAMS TM Combustion Airflow Management System Product Description The Air Monitor Power CAMS TM Combustion Airflow Management
ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget
ACE Automated Soil CO 2 Exchange System Automated operation Automatically exposes soil area between measurements CO 2 analyser in chamber Highly accurate CO 2 IRGA housed directly inside soil chamber assembly