Flexus APPLICATIONS EMERGENCY LIGHTING SUITABLE FOR FLEXIBILITY ADVANCED COMMUNICATION ZERO IMPACT SOURCE BATTERY CARE SYSTEM LOW MANAGEMENT COST

Size: px
Start display at page:

Download "Flexus APPLICATIONS EMERGENCY LIGHTING SUITABLE FOR FLEXIBILITY ADVANCED COMMUNICATION ZERO IMPACT SOURCE BATTERY CARE SYSTEM LOW MANAGEMENT COST"

Transcription

1 increased, as prescribed by the battery manufacturers, in order to avoid damage to or a drop in performance of the storage batteries. Ripple Current: the recharge ripple current (residual AC component) is one of the most important causes that reduce battery reliability and life. Flexus, thanks to the high-frequency battery charger, reduces this value to negligible levels, extending battery life and maintaining high performance for a long time. Wide voltage range: the rectifier is made to be operated with a wide range of values of the input voltage (up to - 40% with half load), reducing the need to discharge the batteries and, as a result, extending battery life. LOW MANAGEMENT COST The technology used and the choice of high performance components mean that Flexus can obtain exceptional performance and efficiency levels, from a very low footprint and dimensions: the lowest footprint in this category, only 0.26 sq. m. for 20kVA Flexus, batteries included high performance up to 94% that permits 35% of the energy dissipated in one year to be saved, compared to similar products present on the market (with average performance 91%). This exceptional performance value makes it possible to recover the initial investment in less than 4 years in operation. output power with power factor 0.9 that provides up to 15% more active power compared to a normal UPS in commerce, guaranteeing the greatest margin in sizing of the UPS for further load increases FLEXIBILITY Flexus can be used for a wide range of applications, thanks to its characteristics of configuration flexibility, accessories and options available and performance levels: suitable for powering capacitive loads such as blade servers, without any reduction of the active power, from 0.9 leading to 0.9 lagging modes of operation: On Line, Eco, Smart Active and Stand By Off Leading Cosϕ (capacitive loads) frequency converter mode Power Share sockets that can be configured in order to maintain the back-up time for the most critical loads or to be activated only when the mains goes down Cold Start to switch on the UPS including when the supply mains is off battery cabinets of various dimensions and capacity, for longer back-up times option to connect a temperature sensor for external battery cabinets, for recharge voltage compensation additional battery chargers to optimize recharge times optional double input of the supply mains isolation transformers to modify the neutral arrangements, in case of separate sources or for galvanic isolation between input and output ADVANCED COMMUNICATION Flexus is equipped with a graphic display that provides information, measures, states and alarms regarding the UPS in 5 different languages. Advanced multiplatform communication, for all operating systems and network environments: Watch&Save 3000 monitoring and shutdown software included with SNMP agent Compatible with PowerNetGuard for the remote assistance service RS232 or USB serial port Flexus Output Power cosϕ 0,9 cosϕ 1 100% kw 1,00 0,75 0,50 0,25 cosϕ 0,9 Lagging Cosϕ (inductive loads) -1-0,8-0,6-0,4-0,2 0 0,2 0,4 0,6 0,8 1 Reactive Power 100% kva Active Power Cosϕ 0,9 Es. 20kVA - 18kW!!! 3 slots for the installation of optional communication accessories such as network adapters, zero-potential contacts, etc. REPO (Remote Emergency Power Off) with which to power down the UPS through a remote emergency pushbutton Input for connection of the auxiliary contact of an external manual bypass Input for synchronization from an external source Graphic mimic panel display for remote connection SUITABLE FOR EMERGENCY LIGHTING APPLICATIONS The FLEXUS series is suitable for protecting information and telecommunications systems, information networks and critical systems in general, where the risks connected with a power supply of poor quality energy could put the continuity of activities and services at risk, entailing high costs. The FLEXUS series is available in kva three-phase input and output models, with double conversion on-line technology according to the VFI-SS-111 classification, as defined by the IEC EN standard. Flexus has been designed and produced with state-ofthe-art technologies and components, in order to guarantee maximum protection for the users powered, no impact on the supply mains and energy saving. ZERO IMPACT SOURCE Thanks to the technology used, Flexus can solve any problem of connection in installations where the supply mains has a limited installed power, where the UPS is also powered by a generator set or where there are problems of compatibility with loads that generate current harmonics; Flexus has indeed zero Flexus impact on the power supply source, be it the mains or a generator set: low distortion of input current less than 3% input power factor 0.99 power walk-in function that guarantees progressive start-up of the rectifier delayed switching-on function, to restart the rectifier igniters when the mains returns, in case of systems with various UPS The Flexus also acts a filter and phaseshift mechanism in respect of the supply mains ahead of the UPS, since it removes the harmonic components and the reactive power generated by the users powered. BATTERY CARE SYSTEM Management of the batteries is fundamental to guaranteeing operation of the power supply unit under emergency conditions. The Battery Care System consists of a series of functions and performances that permit management of the storage batteries in such a way as to obtain the best performance and to extend battery life. Battery recharge: Flexus is suitable for working with hermetically sealed (VRLA), AGM and GEL lead batteries, and openvase and Nickel-Cadmium batteries. According to the type of battery, various recharge methods are available. One-level recharge, typical for the most commonly used VRLA AGM batteries Two voltage levels recharge according the IU characteristic Charge block system to reduce consumption of the electrolyte and further extend the life of VRLA batteries. Compensation of the recharge voltage according to temperature in order to avoid excessive charges and battery overheating. Battery Test in order to detect any falloff in performance or failure of the batteries in good time. Protection against deep discharges: in case of long low load discharges, the end-of-discharge voltage tension will be 50 51

2 Flexus Three-phase input Three-phase output Technical data Models FT 10 FT 12 FT 15 FT 20 Power (kva) Input FT 10 FT 12 FT 15 FT 20 Rated voltage Vac three-phase +N Rated frequency 50/60 Hz Frequency tolerance Hz Power factor at full load 0.99 Pf Current distortion THDI 3% By pass FT 10 FT 12 FT 15 FT 20 Rated voltage Vac three-phase +N Number of phases 3 + N Voltage tolerance 180 ± 264V (selectable) Rated frequency 50 or 60 Hz (selectable) Frequency tolerance ±5 (selectable) Output FT 10 FT 12 FT 15 FT 20 Rated power (kva) Active power with load PF from 0,9 cap. to 0,9 ind Output power factor 0.9 Number of phases 3 + N Rated voltage Vac (selectable) Static variation ± 1% Dynamic variation ± 3% Crest factor (Ipeak/Irms) 3 : 1 Voltage distortion 1% with linear load / 3% with non-linear load Frequency 50/60 Hz Frequency stability on battery mode 0.01% Overload at Pf % infinite, 125% for 10 minutes, 150% for 1 minute, 168% for 5 seconds Batteries FT 10 FT 12 FT 15 FT 20 Type VRLA AGM/GEL Recharge time 6 h 52 Flexus Three-phase input Three-phase output System FT 10 FT 12 FT 15 FT 20 Weight with internal batteries (kg) Dimensions (hwd) (mm) 930 x 320 x 840 Communication 3 communication interface slots/rs232/usb Operating temperature O C - 40 C Relative humidity 90% non condensing Colour Dark grey (RAL 7024) Noise < 56 dba at 1 m Protection rating IP20 Efficiency 94% in On-line mode, 98% in Economy mode Compliance European Directives: L V 73/23/EC and 93/68/EC Low voltage directive EMC 2004/108/EC and 89/336/EC Electromagnetic compatibility directive Standards: Safety IEC EN ; EMC IEC EN C2 Classification according to IEC (Voltage Frequency Independent) VFI - SS Details Powershare sockets Communication interface slot Remote contacts connectors Parallel board Serial interface port USB port 53

3 Personal computers iplug VA single-phase ECO LINE The iplug series is the ideal solution for household, and small home office systems. Its compact size and versatility - push-button operation, led status panel and user-replaceable batteries - make iplug easy to install within a domestic environment to protect systems from surges and blackouts. When mains power fails the load is powered by the inverter and built-in battery. PowerShield 3 UPS monitoring and control software (available for download from can be used for an orderly unattended shutdown of IT systems. LOAD CONFIGURATOR Load type Power (VA)* Personal computer 250 LCD Monitor Monitor 150 Scanner, printer 200 Modem, TV, DVD reader, PlayStation, Hi-Fi, Phone, Fax 50 Laser printer** 200 *Average estimated value. **Use the iplug filtered power output. FEATURES ECO LIne energy efficient product Compact, ergonomic design 5 sockets with battery backup 3 sockets with surge protection only Cold start capability to power up the UPS without mains power User replaceable batteries USB interface for remote monitoring Power cable included Protection from short-circuits Auto restart - when the mains returns after battery exhaustion GS/Nemko safety marking Available with French (2P+E), English, Schuko and Italian outlets. ADVANCED COMMUNICATION PowerShield 3 supervision and shut-down software for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X and Sun Solaris operating systems Plug and Play function. 2 YEAR WARRANTY

4 MODELS iplug 600 iplug 800 POWER INPUT 600VA/360W 800VA/480W Rated voltage Vac Voltage range 230 Vac (+20/-25%) Frequency 50/60 Hz with auto sensing OUTPUT Voltage on mains operation 230 Vac (+20/-25%) Voltage on battery operation 230 Vac (+/- 10%) Frequency on battery operation 50 or 60 Hz (+/- 1%) BATTERIES Type Recharge time VRLA AGM Maintenance-free lead-acid 6-8 h ENVIRONMENTAL Net weight (kg) Gross weight (kg) Dimensions (hwd) (mm) 99 x 175 x 313 Packaging dimensions (hwd) (mm) 260 x 380 x 140 Communication Compliance Marks Operating temperature Colour Altitude and relative humidity Accessories provided USB EN and Directive 2006/95/EC; EN EN and Directive 2004/108 EC CE; GS/NEMKO on Schuko version 0 C / +40 C Black 6000 meters max. elevation, <95% non condensing 1 input supply cable, user guide iplug iplug 800 Rear detail Sockets with UPS protection (no break in power if mains fails) Filtered sockets: overvoltage protection only IEC OUTLETS WITH UPS PROTECTION SAFETY FUSE USB communication port TECHNICAL DETAILS LED detail AVAILABLE SOCKETS schuko socket CEE 7/7P French socket CEE 7/5 ITALIAN socket CEI 23/16 British socket BS1363A

5 QUALITY POWER SUPPLY SENTRY MPS is an on-line double conversion UPS (VFI SS 111 in accordance with IEC EN ) with a transformer isolated inverter. With a compact footprint and high power quality output, SENTRY MPS is designed to protect mission critical applications including data processing, telecommunications, industrial processes, security and electro-medical systems. SENTRY MPS is available from 100 to 800kVA in two or four versions each with different harmonic distortion and power factor for better matching the market requirements: MPS (100 to 200kVA only), MPS LH (100 to 200kVA only), MPS Plus, MPS Sinus. Sentry MPS Three-phase output BATTERY CARE SYSTEM: MAXIMUM LIFETIME POTENTIAL Traditionally, when a mains supply is present the UPS charges its batteries. Battery power is used for the inverter should the input supply fail. Efficient battery management and care is therefore essential to the overall performance of the UPS in an emergency. The SENTRY MPS Battery Care System consists of a range of features designed to provide optimum performance and enhanced operating life: Dual level charging regime to optimise recharge currents and lower recharge times; Temperature compensation and deep discharge protection to reduce overall battery aging; Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries; Predictive battery testing to spot potential battery deterioration and failure. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd. MINIMUM INPACT ON SUPPLIES - EASY SOURCE SENTRY MPS technology removes the problems of over sizing downstream power sources, whilst improving load power factors and current harmonics. The UPS features the latest input current absorption techniques including progressive rectifier start-up and the option to reduce battery charging currents. These features make SENTRY MPS one of the most generator compatible and environmentally friendly UPS available. 66 FLEXIBILITY SENTRY MPS is suitable for a wide range of applications including IT and the most demanding industrial environments suitable for power capacitive loads such as blade servers, without any reduction of the active power, from 0,8 lagging to 0,9 leading. With a broad of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the AROS UPS Group Synchroniser (USG) and Parallel Systems Joiner (PSJ) sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability. EASY INSTALLATION SENTRY MPS has a small footprint (only 0,64 sqm for 200kVA and 1,63 sqm for 400kVA). Front access to internal assemblies and top panel ventilation make space allocation within confined data processing or plant rooms easy. SENTRY MPS can be placed against a wall as there is no requirement for rear or side panel access for maintenance or ventilation. Leading Cosϕ (capacitive loads) cosϕ 0,8 cosϕ 0,9 ADVANCED COMMUNICATION Compatible with PowerNetGuard for remote maintenance Advanced, multi-platform communication, for all operating systems and network environments: Watch&Save 3000 supervision and shut-down software included, with SNMP agent, for Windows 95, 98, NT 4.0, Me, 2000, 2003, XP, Mac OS 9.x, X, Linux, Novell operating systems. The UPS is supplied with a cable for direct connection to the PC (Plug and Play) RS232 double serial port Slot for installation of the mains adapter; EPO contact (Emergency Switching Device) for switching off the UPS with a remote emergency switch Remote mimic panel (LED or LCD) Graphic Remote Panel MPS Output Power 100% kw cosϕ 1 cosϕ 0,9 cosϕ 0,8 1,00 0,75 0,50 0, ,8-0,6-0,4-0,2 0 0,2 0,4 0,6 0,8 1 1,2 Reactive Power APPLICATIONS Servers Local Area Network (LAN) Data centers Telecommunications Industrial equipment Electro-medical equipment OPTIONS Lagging Cosϕ (inductive loads) cosϕ 0,7 cosϕ 0,6 100% kva Active Power Input Isolation transformer UPS Group Syncroniser (UGS) Parallel System Joiner (PSJ) Interface for generator LED remote status panel LCD based remote control panel Graphic Display Remote panel Empty battery cabinets for prolonged runtime 67

6 Fig 1- Bock diagram UPS in parallel up to 8 units EXPANDABILITY The units can be connected in parallel up to 8 units to increase power availability or redundancy. The single module or the system can be expanded any time to suit power requirements without influencing the initial investment. Thanks to the peculiarity of the Hot System Expansion feature, the additional unit can be connected in parallel while the other units are on-line and supplying regular power to the load. The new UPS is on-line and will be set up automatically. 200kVA 68 DUAL BUS SYSTEM The Dual Bus System powers the priority loads from two independent sources. Fig. 2 - Dual bus System DYNAMIC DUAL BUS SYSTEM Two independent systems set in Dual Bus Configuration can be merged together at any time for system Fig. 3 - Dynamic Dual Bus System This configuration increases the redundancy and availability level of a multi-module configuration. Each bus may consist of a single module or up to expansion or maintenance thanks to the PSJ (Parallel System Joiner) option. This provides a lot of flexibility in your installation in case of maintenance or 8 modules in parallel, kept in synchro by the UGS (UPS Group Synchroniser). when it is necessary to change the redundancy level of both systems. 69

7 Sentry MPS Three-phase input Three-phase output Technical data Sentry MPS Technical data Three-phase input Three-phase output Models MPS 100 MPS 120 MPS 160 MPS 200 Power (kva) Models MPS 250 MPS 300 MPS 400 Power (kva) Input MPS 100 MPS 120 MPS 160 MPS 200 Nominal voltage Vac three-phase Voltage tolerance 400 V ± 20% Frequency Hz Power factor >0.95 in the Sinus version Current harmonic distortion <3% in the Sinus version Soft start 0 100% in 30 configurable Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel) Standard features Back Feed protection; separable bypass line Input MPS 250 MPS 300 MPS 400 Nominal voltage Vac three-phase Voltage tolerance 400 V ± 20% Frequency Hz Power factor >0.95 in the Sinus version Current harmonic distortion <3% in the Sinus version Soft start 0 100% in 30 configurable Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel) Standard features Back Feed protection; separable bypass line Battery MPS 100 MPS 120 MPS 160 MPS 200 Type Lead, open vase acid and VRLA, AGM / GEL; NiCd AC ripple current Zero Temperature compensation -0,5 Vx C Battery MPS 250 MPS 300 MPS 400 Type Lead, open vase acid and VRLA, AGM / GEL; NiCd AC ripple current Zero Temperature compensation -0,5 Vx C Output MPS 100 MPS 120 MPS 160 MPS 200 Output MPS 250 MPS 300 MPS 400 Rated power (kva) Rated power (kva) Active power with load PF from 0,9 cap. to 0,8 ind. (kw) Active power with load PF from 0,9 cap. to 0,8 ind. (kw) Number of phases 3 + N Number of phases 3 + N Nominal voltage Vac three-phase + N Nominal voltage Vac three-phase + N Static stability ± 1% Static stability ± 1% Dynamic stability ± 5% in 10 msec. Dynamic stability ± 5% in 10 msec. Voltage distortion with linear load 1% Voltage distortion with linear load 1% Voltage distortion with non linear load 3% Voltage distortion with non linear load 3% Frequency 50 or 60 Hz configurable Frequency 50 or 60 Hz configurable Waveform Sinusoidal Waveform Sinusoidal Crest factor (Ipeak/Ipms) 3:1 Crest factor (Ipeak/Ipms) 3:1 Overload 110% for 60 ; 125% for 10 ; 150% for 1 Overload 110% for 60 ; 125% for 10 ; 150% for 1 System MPS 100 MPS 120 MPS 160 MPS 200 Remote signalling Voltage-free contacts (configurable) Remote commands EPO and bypass Communication Double RS232 + remote contacts + 2 communication interface slots Efficiency Up to 94% Dimensions (wdh) (mm) 800x800x1900 (base version) Weight (kg) Noise level dba a 1 m Operating temperature 0 C / +40 C Relative humidity <95% non condensing Protection degree IP20 Colour Light grey (RAL 7035) Compliance Directives EEC 73/23-93/68-89/336 Safety IEC EN ; EMC IEC EN ; Performance IEC EN Classification as per IEC (Voltage Frequency Independent) VFI - SS System MPS 250 MPS 300 MPS 400 Remote signalling Voltage-free contacts (configurable) Remote commands EPO and bypass Communication Double RS232 + remote contacts + 2 communication interface slots Efficiency Up to 94% Dimensions (wdh) (mm) 850x1630x x1630x1900 Weight (kg) Noise level 70 dba a 1 m Operating temperature 0 C / +40 C Relative humidity <95% non condensing Protection degree IP20 Colour Light grey (RAL 7035) Compliance Directives EEC 73/23-93/68-89/336 Safety IEC EN ; EMC IEC EN ; Performance IEC EN Classification as per IEC (Voltage Frequency Independent) VFI - SS

8 Sentry MPS Three-phase input Three-phase output Technical data Models MPS 500 MPS 600 MPS 800 Power (kva) Input MPS 500 MPS 600 MPS 800 Nominal voltage Vac three-phase Voltage tolerance 400 V ± 20% Frequency Hz Power factor >0.93 in the Sinus version Current harmonic distortion <3% in the Sinus version Soft start 0 ± 100% in 30" configurable Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel) Standard features Back Feed protection; separable bypass line Battery MPS 500 MPS 600 MPS 800 Type Lead, open vase acid and VRLA, AGM / GEL; NiCd AC ripple current < 1% Temperature compensation -0,5 Vx C Output MPS 500 MPS 600 MPS 800 Rated power (kva) Active power with load PF from 0,9 cap. to 0,8 ind. (kw) Number of phases 3 + N Nominal voltage Vac three-phase + N Static stability ± 1% Dynamic stability ± 5% in 10 msec. Voltage distortion with linear load 1% Voltage distortion with non linear load 3% Frequency 50 or 60 Hz configurable Waveform Sinusoidal Crest factor (Ipeak/Ipms) 3:1 Overload 110% for 60 ; 125% for 10 ; 150% for 1 System MPS 500 MPS 600 MPS 800 Remote signalling Voltage-free contacts (configurable) Remote commands EPO and bypass Communication Double RS232 + remote contacts + 2 communication interface slots Efficiency Up to 94% Dimensions (wdh) (mm) 3200x980x x1000x1900 Weight (kg) Noise level 78 dba a 1 m Operating temperature 0 C / +40 C Relative humidity <95% non condensing Protection degree IP20 Colour Light grey (RAL 7035) Compliance Directives EEC 73/23-93/68-89/336 Safety IEC EN ; EMC IEC EN ; Performance IEC EN Classification as per IEC (Voltage Frequency Independent) VFI - SS

9 PROTECTION FOR INDUSTRIAL APPLICATION MPS 1Ph is an on-line double conversion UPS (VFI SS 111 in accordance with IEC EN ) with transformers isolated inverter and rectifier. MPS 1Ph has a compact foot print and high quality output to provide the ultimate power protection for industrial applications: industrial processes, petrochemical, power plant, energy etc. INDUSTRIAL ENVIRONMENT MPS 1Ph is suitable for severe installation environments such as petrochemical manufacturing sites, where the operating conditions (levels of vibration, mechanical stress, ambient temperatures and dust ingress) require a more robust and industrialized UPS design to those installed within, for example, data centres. HIGH Icc A high short-circuit current (Icc = 3 In) making the UPS suitable for loads with high current peaks; during switch-on or a load step-change. 220V DC VOLTAGE An input transformer and isolated inverter to protect the 220Vdc bus bar (from 108 to 114 blocks), the recognised industrial standard. REDUNDANT VENTILATION 100% redundant ventilation with 50% fan loading at nominal load and each fan monitored for breakdown or failure. Sentry MPS Single-phase output MINIMUM IMPACT ON SUPPLIES - EASY SOURCE MPS 1Ph technology removes the problems of over sizing upstream power sources, whilst improving load power factors and current harmonics. The UPS features the latest input current absorption techniques including progressive rectifier start-up and the option to reduce battery charging currents. These features make MPS 1Ph one of the most generator compatible and environmentally friendly UPS available. BATTERY CARE SYSTEM: MAXIMUM LIFETIME POTENTIAL Traditionally, when a mains supply is present the UPS charges its batteries. Battery power is used for the inverter should the input supply fail. Efficient battery management and care is therefore essential to the overall performance of the UPS in an emergency. The MPS 1Ph Battery Care System consists of a range of features designed to provide optimum performance and enhanced operating life: Dual level charging regime to optimise recharge currents and lower recharge times Temperature compensation and deep discharge protection to reduce overall battery aging Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries Predictive battery testing to spot potential battery deterioration and failure MPS 1Ph is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd. FLEXIBILITY With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the Aros UPS Group Synchroniser (USG) and Parallel Systems Joiner (PSJ) sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability. ADVANCED COMMUNICATION Compatible with PowerNetGuard for remote maintenance Advanced, multi-platform communication, for all operating systems and network environments: Watch&Save 3000 supervision and shut-down software included, with SNMP agent, for Windows 95, 98, NT 4.0, Me, 2000, 2003, XP, Mac OS 9.x, X, Linux, Novell operating systems. The UPS is supplied with a cable for direct connection to the PC (Plug and Play) RS232 double serial port Slot for installation of the mains adapter; EPO contact (Emergency Switching Device) for switching off the UPS with a remote emergency switch Remote mimic panel (LED or LCD) 74 Sentry MPS Three-phase input Single-phase output Technical data Models MPM 30 MPM 40 MPM 60 MPM 80 Power (kva) Input MPM 30 MPM 40 MPM 60 MPM 80 Nominal voltage Vac three-phase Voltage tolerance 400 V ± 20% Frequency Hz Power factor 0.93 Current harmonic distortion <5% C Soft start 0 100% in 120 configurable Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel) Standard features Back Feed protection; separable bypass line Battery MPM 30 MPM 40 MPM 60 MPM 80 Numeber of cells Max Vdc 274 V Temperature compensation -0,5 Vx C Output MPM 30 MPM 40 MPM 60 MPM 80 Rated power (kva) Active power (kw) Nominal voltage 230Vac single-phase Static stability ± 1% Dynamic stability ± 5% Voltage distortion with linear load <1% Voltage distortion with non linear load <3% Frequency 50 or 60 Hz configurable Crest factor (Ipeak/Ipms) 3:1 Overload 110% for 60 ; 125% for 10 ; 150% for 1 Short circuit current 3 I nom. System MPM 30 MPM 40 MPM 60 MPM 80 Remote signalling Voltage-free contacts Remote commands EPO and bypass Communication Double RS232 + remote contacts + 2 communication interface slots Efficiency Up to 94% Dimensions (wdh) (mm) 800x800x x800x1900 Weight (kg) Noise level dba a 1 m Ventilation Redundant fans Operating temperature 0 C / +40 C Relative humidity <95% non condensing Protection degree IP20 Colour Light grey (RAL 7035) Compliance Directives EC 73/23-93/ /108 Safety IEC EN ; EMC IEC EN ; Performance IEC EN Classification as per IEC (Voltage Frequency Independent) VFI - SS

10 10/30 kva Sentry Multistandard SENTRY MULTISTANDARD provides maximum protection for critical data processing networks and security applications, thanks to its advanced design, selectable operating modes and communications capabilities. Operating modes include: On-line, Economy, Smart-Active, Standby/Off and Voltage Stabilisation. Standard communications features include a front panel LCD with 128 potential messages, RS232 interfaces, EPO input, communications interface slot and Watch&Save 3000 management software. The SENTRY MULTISTANDARD series includes kVA single/singlephase, three/single-phase and kva three-phase models, and uses on-line double conversion technology (VFI). The load is powered continuously by the inverter with a filtered, stabilised and regulated sinewave supply. The input and output filters considerably increase the immunity of the load to mains disturbances and surges, even on bypass. LOW POWER CONSUMPTION On-line Mode: up to 92% efficiency can be achieved due to the use of IGBT technology, increasing to 98% in one of the other operating modes Economy Mode: uses Line Interactive (VI) technology to power less critical loads from the mains supply for certain periods Smart Active: if the mains supply is out of range, the UPS will power the load from the inverter as an On-line UPS. When the mains supply returns to within range again, the UPS will monitor this for a certain period before selecting Line Interactive operation. Fig. 1 Block diagram UPS in parallel up to 8 units 10/30 kva Battery cabinet SIMPLE TO INSTALL Option to connect the UPS to singlephase or three phase mains supplies (SM series) Panel adjustment to offset voltage drop down long cable runs MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 8 units in parallel for power capacity or redundancy HIGH LEVEL BATTERY RELIABILITY Automatic battery test Recharge compensated for temperature Automatic or manual rapid charge (boost) duration progammable MAINTENANCE SIMPLICITY = LOW MTTR For the 40 to 80 kva models, open the door and remove the protective panel (standards requirement) and the power components - mounted on a sliding tray - can be pulled out to provide easy access to all the electrical and electronic components for maintenance and repair work. This particular feature means that the MTTR (Mean Time To Repair) is much lower than traditional UPS designs with less easily reached assemblies, which has longer times due to the compact size of the products and difficult access to the parts. A large amount of maintenance information is available from the front mimic panel and LCD. In addition system operating parameters are software configurable via a local PC to allow new functions to be added or adjustments made to operating specifications SUITABLE FOR EMERGENCY LIGHTING APPLICATIONS

11 SENSITIVE SUPPLY COMPATIBLE For power supply sources that are particularly sensitive to harmonics (generator sets or transformers of low power with respect to that of the UPS) it is often a good idea to take action to limit the harmonics injected back into the supply by the UPS. SENTRY MULTISTANDARD series is also available with built-in active filter using high frequency Isolated Gate Bipolar (IGBT) Technology with Digital Signal Processor (DSP) control. The Active Filter helps to reduce harmonics generated by the UPS into the supply which could disrupt the operation of downstream generators and transformers whose rating is closely matched to that of UPS. UPS input current with optional Active Filter advanced technology The active filter reduces harmonic distortion of the phase and neutral currents. The Digital Signal Processor (DSP) and the current mode instantly control and monitor the input current to maintain a perfect sinewave with less than 4% harmonic distortion maximum efficiency Thanks to the active filter Sentry Multistandard systems have low input distortion even at low loads and their overall efficiency is not affected by generator frequency variations or line impedance reduction of neutral current The active filter reduces the input neutrals current by up to 3.5 times their nominal rating to help avoid oversizing input protections and conductors maximum reliability Sentry Multistandard systems are extremely reliable. Overall UPS performance is unaffected should the harmonic filter fail Sentry Multistandard with Active Filter (internal view) excellent capabilities Input distortion: (THDi) less than 4% Input power factor: >0.99 Efficiency: up to 93% Sentry Multistandard can also be supplied without the Active Filter for installations less sensitive to current harmonics. OTHER CHARACTERISTICS Sentry Multistandard is able to supply loads with power factor from 0,8 capacitive to 0,8 inductive without derating the active power (KW) High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD in several languages Reduced noise levels: high frequency inverter bridge Back feed protection standard: to avoid energy feeding back into the mains supply (in compliance with CEI 11-20; DK5600) Power factor correction (input power factor, close to 1) By pass may be deactivated to allow operation as a frequency converter (at 50 or 60 Hz) Emergency operation: the UPS can be set to operate only when the mains fails (for emergency lighting) Multistandard Output Power Leading Cosϕ (capacitive loads) Lagging Cosϕ (inductive loads) cosϕ 0,8 cosϕ 0,9 100% kw cosϕ 1 cosϕ 0,9 cosϕ 0,8 1,00 Operating status, alarms, applied load, battery charging. 0,75 0,50 100% kva Controls and settings menu. Active Power 0, ,8-0,6-0,4-0,2 0 0,2 0,4 0,6 0,8 1 Reactive Power Language selection menu. ADVANCED COMMUNICATION Compatible with PowerNetGuard for remote maintenance Advanced, multi-platform communication, for all operating systems and network environments: Watch&Save 3000 supervision and shut-down software included, with SNMP agent, for Windows 95, 98, NT 4.0, Me, 2000, 2003, XP, Mac OS 9.x, X, Linux, Novell operating systems. The UPS is supplied with a cable for direct connection to the PC (Plug and Play) Double RS232 serial ports Network adapter slot for SNMP agent Emergency Power Off (EPO) shutdown input contact Remote control mimic panel APPLICATIONS Local Area Networks (LAN) Data Centers Servers Industrial PLCs Cash registers Electromedical devices Emergency devices (lights/alarms) Telecommunication devices e-business (Servers, Farms, ISP/ASP/POP) Battery voltages, internal operating temperatures. OPTIONS Input isolation transformer Active filter LED remote status panel LCD based remote control panel Graphic Display remote control panel Empty battery cabinet for prolonged runtime Additional battery charger Dual input mains 40/80kVA 40/80kVA 56 57

12 Sentry Multistandard Three- / Single-phase input Single-phase output Technical data Sentry Multistandard Technical data Three-phase input Three-phase output Input SM10 SM15 SM20 Rated voltage 230 Vac single-phase or 400 Vac three-phase + N Voltage range ± 20% Frequency range Hz Power factor > 0.99 Current harmonic distortion Sinewave absorbtion THDi <4% (3Ph input) (1) Input ST10 ST15 ST20 ST30 ST40 ST60 ST80 Rated voltage 400 Vac three-phase + N Voltage range ± 20% Frequency range Hz Power factor > 0.99 Current harmonic distortion Sinewave absorbtion THDi <4% (3Ph input) (1) By pass SM10 SM15 SM20 Rated voltage 230 Vac Number of phases 1 Permitted voltage range ± 15% (selectable from ± 5% to ± 25%) Rated frequency 50/60 Hz Permitted frequency range ± 2% (selectable from ± 1% to ± 5%) By pass ST10 ST15 ST20 ST30 ST40 ST60 ST80 Rated voltage 400 Vac Number of phases 3 + N Permitted voltage range ± 15% (selectable from ± 5% to ± 25%) Rated frequency 50/60 Hz Permitted frequency range ± 2% (selectable from ± 1% to ± 5%) Batteries SM10 SM15 SM20 Type Lead, open vase acid and VRLA, AGM / GEL; NiCd Recharge time 6 h Batteries ST10 ST15 ST20 ST30 ST40 ST60 ST80 Type Lead, open vase acid and VRLA, AGM / GEL; NiCd Recharge time 6 h 4-8 h Output SM10 SM15 SM20 Rated power (kva) Active power with load PF from 0,8 cap. to 0,8 ind. (kw) 8 12/10,5 (2) 16/12 (2) Number of phases 1 Rated voltage 230 Vac Voltage regulation range Vac Crest factor (Ipeak/Irms) 3 : 1 Distortion with linear load 2% Static stability ± 1% Dynamic stability ± 5% in 10 ms Frequency 50 / 60 Hz selectable Overload 110% 125% 150% of the rated current for 5 h/10 /1 Output ST10 ST15 ST20 ST30 ST40 ST60 ST80 Rated power (kva) Active power with load PF from 0,8 cap. to 0,8 ind. (kw) Number of phases 3 + N Rated voltage Vac selectable Voltage regulation range Vac Crest factor (Ipeak/Irms) 3 : 1 Distortion with linear load 2% Static stability ± 1% Dynamic stability ± 5% in 10 ms Frequency 50 / 60 Hz selectable Overload 110%125% 150% of the rated current for 5h/10 /1 System SM10 SM15 SM20 Weight (kg) From 105 to 243 From 110 to 330 From 125 to 345 Dimensions (wdh) (mm) 450x750x1200 Remote signaling Volt free contacts Remote controls EPO and bypass Communication Double RS232/C + remote contacts + communication interface slot Operating temperature O C / +40 C Relative humidity < 95% non condensing Colour Dark grey (RAL 7024) Noise <56 dba at 1 m Protection degree IP20 Efficiency > 92% in On-Line Mode, > 98% in Economy Mode/Smart Active Mode/Standby-Off Mode/AVS Mode Compliance EN EMC EN Directives 73/23-93/68-89/336 EEC EN System ST10 ST15 ST20 ST30 ST40 ST60 ST80 Weight (kg) From 110 to 258 From 115 to 335 From 130 to 350 From 144 to Dimensions (wdh) (mm) 450x750x x740x1400 Remote signaling Volt free contacts Remote controls EPO and bypass Communication Double RS232/C + remote contacts + communication interface slot Operating temperature O C / +40 C Relative humidity <95% non condensing Colour Dark grey (RAL 7024) Noise <56 dba at 1 m <60 dba at 1 m Protection degree IP20 Efficiency > 92% in On-Line Mode, > 98% in Economy Mode/Smart Active Mode/Standby-Off Mode/AVS Mode Compliance EN EMC EN Directives 73/23-93/68-89/336 EEC EN (1) Version with Active Filter (2) Version with single-phase input 58 59

13 Sentinel 7 Sentinel 7 Technical data Models S7-700 S S POWER S S S POWER S S POWER Power 700VA/560W 1000VA/800W 1500VA/1200W 2200VA/1760W 3000VA/2400W Input S7-700 S S POWER S S S POWER S S POWER Nominal voltage Vac Voltage range for no battery intervention 140 Vac < Vin < 276 LOAD / 184 Vac < Vin < % LOAD Maximum permitted voltage 300 Vac Nominal frequency 50/60 Hz ± 5% Power factor > 0.99 Current distortion δ7% By pass S7-700 S S POWER S S S POWER S S POWER Voltage tolerance Vac Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable) Sentinel 7 is the latest evolution of the successful Aros Sentinel 6 online UPS. This latest development has been designed with the environment in mind. Sentinel 7 is an on-line double- conversion UPS offering the highest levels of reliability and protection for critical servers, voice and data processing IT systems. For long runtime applications, Sentinel 7 (POWER models) can be fitted with matching battery extension packs which also include additional battery boost chargers. In terms of communications, each Sentinel 7 has a built-in mimic panel with an LCD to show input and output voltages, and battery charge status. The inverter is a totally new design, fully microprocessor controlled and constructed to achieve the highest levels of operating efficiency and configuration options. Sentinel 7 UPS also have USB communication ports as standard, with a built-in expansion slot for additional adapters, protocol converters and relate contact cards. The UPS is highly efficient. Sentinel 7 is designed to save energy and has a MAIN FEATURES Filtered, stabilised, reliable output voltage: on-line double-conversion technology (VFI in accordance with IEC ) with built-in EMI filters High overload capability up to 150% Programmable auto-restart when mains power returns Programmable cold-start from battery Power factor correction (UPS input power factor close to 1) Wide input voltage tolerance (from Vac) without battery usage Possibility to extend autonomy for several hours Fully configurable using UPS Tools configuration software High level of battery reliability (automatic and manually-activated battery tests) High level of UPS reliability (total microprocessor control) Low impact on the mains (sinusoidal absorption) Input protection with fuse which can be reset. ADVANCED COMMUNICATION Advanced communication, multiplatform, for all operating systems and network environments, Watch&Save 3000 supervision and shut-down software included for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and VMware ESX operating systems and other Unix operating systems UPS Tools configuration and personalisation software supplied as standard RS232 serial port and opto-isolated contacts USB port Slot for communication cards. Output S7-700 S S POWER S S S POWER S S POWER Voltage distortion with linear load/with distorting load < 2% / < 4% Frequency Can be selected: 50 Hz or 60 Hz or self-learning Static variation / Dynamic variation ± 1% / 5% in 20 msec. Waveform Sinewave Current crest factor 3 : 1 On Line / ECO Mode and Smart Active efficiency 98% Overload 2 min. (100%<Load<110%), 5 sec. (100%<Load<150%), 1 sec. (8>Load>150%) Batteries S7-700 S S POWER S S S POWER S S POWER Type VRLA AGM lead, maintenance-free Charging time 2-4 hours N.A. 2-4 hours N.A. 2-4 hours N.A. System S7-700 S S POWER S S S POWER S S POWER Net weight (kg) 10,9 13,3 7 14,8 25,6 10, Gross weight (kg) 12,5 14,9 8,6 16,4 28,8 13,8 31,2 17,2 Dimensions (wdh) (mm) 422x235x x333x190 Packaging dimensions (wdh) (mm) 500x340x x470x325 Protection against overvoltages 300 joules Protection devices Overcurrent - short circuit - overvoltage - undervoltage - circuit breaker - excessively low battery Communication USB / DB9 with RS232 and contacts / Slot for communication interface Standards Safety: EN and Directive 2006/95/EC; EMC: EN category C2 and Directive 2004/108/EC Ambient temperature / Relative humidity 0 C / +40 C / < 95% not condensed Colour Black Noise level < 40 1 m Standard equipment Power cable, serial cable, USB cable, safety manual, quick start, software on CD-ROM Details S POWER S POWER power-off push-button feature to reduce energy consumption to zero, when no load is connected or switched off. Sentinel 7 models include 700VA, 1000VA, 1500VA, 2200VA and 3000VA. S S POWER Usb port Serial Interface Communication slot Battery Expansion connector Thermal output Protection Output Sockets Input thermal protection Input socket

14 Sentinel 7 RT Sentinel 7 RT is the high density version of the Sentinel 7 range of doubleconversion on-line UPS. Sentinel 7 RT is designed to power critical loads such as servers, storage systems, telephone equipment, medical systems and industrial applications. The UPS is ideal for Blade servers with an input power factor close to Unity (1). The UPS has can be used as tower UPS or within a rackmount cabinet, and takes up only 2U in height. Sentinel 7 RT has a modern design, choice of functional formats, and represents the state-of-the-art technology from the Aros research & development team. The UPS can achieve an on-line operating efficiency of 92%. For critical business continuity applications requiring long runtimes, Sentinel 7 RT can be installed with battery extension packs (POWER models) with their own internal battery chargers to maintain sensible recharge times. The UPS also incorporates the Aros power-off function found in other UPS. Sentinel 7 RT is designed to save energy when no loads are connected. SIMPLIFIED INSTALLATION Tower or Rackmount UPS: Sentinel 7 RT can be installed as tower or 19 rackmount UPS, with a front mimic panel that can be turned through 90º to suit the installation. Noise Free Operation (<40dBA): the UPS can be installed in any environment thanks to its PWM digitally-controlled high frequency inverter. High Temperature Operation: UPS components are sized for high temperature operation up to 40ºC and are not therefore stressed during normal operational environments. EnergyShare: Sentinel 7 RT output sockets can be programmed to disconnect less critical loads when the mains power fails. REDUCED MANAGEMENT COSTS Sentinel 7 RT can be programmed remotely via software or set manually from the front mimic panel to operate in a range of energy saving operating modes: On Line: maximum power protection and output voltage waveform quality ECO: to increase operating efficiency to 98% and provide line interactive protection Smart Active: with the UPS selecting automatically its operating mode - ECO or On-Line dependent upon the reliability and quality of the local mains power supply. Backup: for emergencies only with the UPS only operating when mains power fails Frequency converter: from 50 to 60Hz or 60 to 50Hz. ADVANCED COMMUNICATION Sentinel 7 RT offers maximum flexibility for integrations with any communication system. Multiplatform communication for all operating systems and network environments, Watch&Save 3000 supervision and shut-down software included for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and VMware ESX operating systems and other Unix operating systems. UPS Tools configuration and personalisation software supplied as standard. RS232 serial port and opto-isolated contacts. USB port Slot for communication cards such as Modbus/Jbus, TCP/IP, SNMP and relay contacts. HIGH OUTPUT VOLTAGE QUALITY Even with distorting loads (IT loads with a crest factor of up to 3:1). High short circuit current on bypass. High overload capacity: 150% from inverter (even with no mains power). Filtered, stabilised, reliable (On Line double conversion technology (VFI in accordance with EN class C1) standard with filters to suppress atmospheric disturbances. Load power factor correction: incoming UPS power factor close to 1 and sinusoidal current absorption. HIGH LEVELS OF BATTERY RELIABILITY Automatic and manual battery tests Batteries are hot-swappable and user replaceable. Unlimited battery runtime extension using battery extension packs. OTHER FEATURES Output voltage can be selected using software ( V). Auto-restart when mains power returns (programmed via software). Stand-by on Bypass: when the machine is switched off, it automatically goes into bypass operation with batteries charging. Power-Off with zero load connected to save energy. Low battery warning Power-on delay Full microprocessor control. Automatic bypass without interruption Status, measurements and alarms available on the front panel mimic panel and LCD UPS firmware upgrade via PC platform Input protection including a user reset thermal switch (up to 1500VA) Back-feed protection Manual option to switch to bypass.

15 Sentinel 7 RT Technical data Sentinel 7 RT Models S7 RT-1000 S7 RT-1500 S7 RT-2200 S7 RT-2200 POWER S7 RT-3000 S7 RT-3000 POWER Power 1000VA/900W 1500VA/1350W 2200VA/1980W 2200VA/1760W 3000VA/2700W 3000VA/2400W Input S7 RT-1000 S7 RT-1500 S7 RT-2200 S7 RT-2200 POWER S7 RT-3000 S7 RT-3000 POWER Nominal voltage Vac Voltage range for no battery intervention 140 Vac < Vin < 276 LOAD / 184 Vac < Vin < % load Maximum permitted voltage 300 V Nominal frequency 50/60 Hz ±5Hz Frequency range 50 Hz ± 5% / 60 Hz ± 5% Power factor > 0.98 Current distortion δ7% By pass S7 RT-1000 S7 RT-1500 S7 RT-2200 S7 RT-2200 POWER S7 RT-3000 S7 RT-3000 POWER Voltage tolerance Vac Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable) System S7 RT-1000 S7 RT-1500 S7 RT-2200 S7 RT-2200 POWER S7 RT-3000 S7 RT-3000 POWER Net weight (kg) Gross weight (kg) Dimensions (wdh) (mm) 425x450x87 (425x19"x2U) 625x450x87 (625x19"x2U) Packaging dimensions (wdh) (mm) 600x245x x245x600 Protection against overvoltages 300 joules Protection devices Overcurrent - short circuit - overvoltage - undervoltage - circuit breaker - excessively low battery Communication USB / DB9 with RS232 and contacts / Slot for communication interface Standards Safety: EN and Directive 2006/95/EC; EMC: EN category C2 and Directive 2004/108/EC Ambient temperature O C / +40 C Relative humidity < 95% not condensed Colour Black Noise level < 40 1 m Standard equipment Power cable, serial cable, USB cable, safety manual, quick start, software on CD-ROM Details Output S7 RT-1000 S7 RT-1500 S7 RT-2200 S7 RT-2200 POWER S7 RT-3000 S7 RT-3000 POWER Voltage distortion with linear load/with distorting load < 2% / < 4% Frequency Can be selected: 50 Hz or 60 Hz or self-learning Static variation ±1% Dynamic variation δ5% in 20 msec Waveform Sinewave Current crest factor 3 : 1 On Line / ECO Mode and Smart Active efficiency 98% S7 RT1000 S7 RT1500 Input Sockets Input thermal protection Batteries S7 RT-1000 S7 RT-1500 S7 RT-2200 S7 RT-2200 POWER S7 RT-3000 S7 RT-3000 POWER Type VRLA AGM lead, maintenance-free Emergency switch device (esd) S7 RT2200/2200 POWER Battery expansion outlet Output sockets Input plug Charging time 2-4 hours Overload times S7 RT-1000 S7 RT-1500 S7 RT-2200 S7 RT-2200 POWER S7 RT-3000 S7 RT-3000 POWER S7 RT3000/3000 POWER Rs232 serial Usb Port 100% < Load < 110% 1 minute 110% < Load < 150% 4 seconds Load > 150% 0,5 seconds

16 SENTINEL XR is the best solution for protecting medium sized networking applications which require the highest possible levels of reliability. The UPS is designed to support a wide applications from IT to security. SENTINEL XR is unique in that the UPS can be placed directly onto the floor or mounted in 19 rack mount cabinets. The range is available in VA models. The UPS is primarily an on-line double-conversion (VFI) technology system with further selectable operating modes that can configure the UPS to protect applications including emergency lighting, security and medical systems. Each UPS features advanced communications and diagnostics including a digital front panel display that can turned to suit the installation format, RS232 and USB interfaces, and an internal adaptor slot for SNMP and other interface card options. Watch&Save 3000 software is supplied as standard. Sentinel XR SIMPLIFIED INSTALLATION The UPS can be installed as a floor standing tower or 19 rack mount UPS. The front panel digital display can be pulled out (using the keys provided) and rotated to suite the installation format Low noise level (<40dBA) thanks to the digitally PWM controlled ventilation system which is load and temperature dependent, and the use of an inverter with a high switching frequency (>20kHZ, above the audible range) Optional bolt-on maintenance bypass (SENTINEL XR kva models) to allow service without disruption to the loads Performance guaranteed in temperatures up to 40 C Two IEC output plugs with thermal protection (SENTINEL XR kva) PowerShare output socket (2x10A IEC) functionality on SENTINEL XR kva models GUARANTEED OUTPUT QUALITY Even with typical distorting IT loads with crest factors of 3:1 Increased short circuit current on the bypass Increased overload capacity: 150% on inverter even when mains supply has failed Reliable, filtered, stabilised and regulated sinewave output (double conversion technology VFI in conformity with IEC specifications) with filters for atmospheric disturbance suppression Rephasing of load as the UPS has an input power factor close to 1, with a sinusoidal input current HIGHLY RELIABLE BATTERY PERFORMANCE Automatic and manual battery tests Unique Low Ripple Current Discharge (LRCD) to help prolong battery life Hot-swap user replaceable batteries Unlimited extendable back-up time using modular design Battery Extension Packs Increased ride through (without batteries) on mains breaks up to 40ms and for fluctuations ranging from 84 to 276Vac OTHER CHARACTERISTICS Output voltage selection: Vac Auto restart when mains power returns programmed using the UPS Tools software supplied Bypass on: when the UPS is switched off, it automatically goes into bypass mode to charge the batteries Automatic power down due to minimum load End of battery discharge pre-alarm Delayed start up Completely digitally controlled Automatic bypass with no break in power supply Use of IMS (Insulated Metallic Substrates) modules Status, measurements, and alarms available on the standard backlit display UPS can be updated digitally (flash upgradeable) Input protected by resettable thermally activated switch Back-feed protection: to avoid current being fed back into the mains should a fault occur Manual switch over to bypass Microsoft Certified Product ADVANCED COMMUNICATION Advanced, multi-platform communication for all operating systems and network environments: Watch&Save 3000 supervision and shut-down software included, with SNMP agent, for Windows 95, 98, NT4.0, Me, 2000, 2003, XP, Mac OS 9.x, X, Linux, Novell operating systems. The UPS is supplied with a communications cable for Plug and Play PC connection Plug & Play feature USB port RS232 serial port Interface card slot Microsoft certification APPLICATIONS Local Area Networks (LAN) Data Centers Servers Industrial PLCs Cash registers Electromedical devices Emergency devices (lights/alarms) 2-YEAR WARRANTY SUITABLE FOR EMERGENCY LIGHTING APPLICATIONS Display LCD custom SELECTABLE OPERATING MODES On line Economy Mode: selects Line Interactive VI technology to power noncritical loads from mains and achieve up to 98% operating efficiency Smart Active Mode: the UPS selects automatically whether to operate in On-line VFI technology - full system protection or Line Interactive VI mode depending on the stability of the mains supply Emergency: the UPS can be programmed to work only when the mains fails - suitable for emergency lighting Frequency conversion 50 or 60Hz OPTIONS Extended runtime solutions with/without battery charger External maintenance bypass (except 3300VA and 4000VA) Interface cards Telescopic rails for rack cabinet 40 41

17 Sentinel XR Single-phase input Single-phase output Technical data Models SXR-3300 SXR-4000 SXR-5000 SXR-6000 SXR-8000 SXR Power 3300VA/2300W 4000VA/2400W 5000VA/3500W 6000VA/4200W 8000VA/6400W 10000VA/8000W Input SXR-3300 SXR-4000 SXR-5000 SXR-6000 SXR-8000 SXR Rated voltage Vac Minimum voltage 164 load 100% 84 load 50% Rated frequency 50/60 Hz ± 5 Hz Power factor > 0.98 Current distortion 7% By pass SXR-3300 SXR-4000 SXR-5000 SXR-6000 SXR-8000 SXR Voltage range Vac (selectable in Economy Mode and SMART ACTIVE Mode) Frequency range Selected frequency ±5 % (user configurable) Batteries SXR-3300 SXR-4000 SXR-5000 SXR-6000 SXR-8000 SXR Recharge time 4-6 h Output SXR-3300 SXR-4000 SXR-5000 SXR-6000 SXR-8000 SXR Rated voltage Vac selectable Static variation 1,5 % Dynamic variation 5% in 20 ms Waveform Sinewave Voltage distortion with linear load < 3% Voltage distortion with non-linear load < 6% Frequency 50/60 Hz selectable Crest factor 3 : 1 Overload capacity SXR-3300 SXR-4000 SXR-5000 SXR-6000 SXR-8000 SXR % < Load < 110% 1 110% < Load < 125% 4 125% Load < 150% 4 Load > 150% Sentinel XR System SXR-3300 SXR-4000 SXR-5000 SXR-6000 SXR-8000 SXR Weight (kg) Dimensions (wdh) (mm) tower 175x520x x660x455 2x175x660x455 Dimensions (wdh) (mm) rack 483x520x175(4U) 483x660x175(4U) 2x483x660x175(4U) On Line Efficiency 92% Line-interactive/Smart Active Efficiency 98% Operating temperature O C / +40 C Relative humidity < 95% non condensing Protection Overload - short-circuit - overvoltage - undervoltage - temperature - low battery Compliance EN EMC EN Directives 73/23-93/68-89/336 EEC EN Communication USB / RS232 + communication interface slot Colour Dark grey (RAL 7035) Noise <40 dba at 1 m <45 dba at 1 m Accessories provided 2x10A cables; 1xIEC-16A plug; 2 cable guides; terminal board connection; software; serial cable; software; serial cable; plastic keys plastic keys to release display; handles kit to release display; handles kit Details USB port Serial port Interface card slot SNMP or additional RS232 ports Input thermal protection re-set Input hardwired gland Output hardwired glands Battery extension pack connector Input cable access Output cable access SXR SXR SXR

18 Sentinel XR Three-phase input Single-phase output Technical data Models SXR-6500 SXR-8000 SXR Power 6000VA/5200W 8000VA/6400W 10000VA/8000W Input SXR-6500 SXR-8000 SXR Rated voltage 400 Vac tree-phase + N Minimum voltage 164 load 100% - 84 load 50% Rated frequency 50/60 Hz ± 5 Hz Power factor > 0.95 By pass SXR-6500 SXR-8000 SXR Voltage range Vac (selectable in Economy Mode and SMART ACTIVE Mode) Frequency range Selected frequency ±5 % (user configurable) Batteries SXR-6500 SXR-8000 SXR Recharge time 4-6 h Output SXR-6500 SXR-8000 SXR Rated voltage Vac selectable Static variation 1,5 % Dynamic variation 5% in 20 ms Waveform Sinewave Voltage distortion with linear load < 3% Voltage distortion with non-linear load < 6% Frequency 50/60 Hz selectable Crest factor 3 : 1 Overload capacity SXR-6500 SXR-8000 SXR % < Load < 110% 1 110% Load < 150% 4 Load > 150% Sentinel XR System SXR-6500 SXR-8000 SXR Weight (kg) Dimensions (wdh) (mm) tower 2x175x660x455 Dimensions (wdh) (mm) rack 2x483x660x175(4U) On Line Efficiency 92% Line-interactive/Smart Active Efficiency 98% Operating temperature O C / +40 C Relative humidity < 95% non condensing Protection Overload - short-circuit - overvoltage - undervoltage - temperature - low battery Compliance EN EMC EN Directives 73/23-93/ /108EC EN Communication USB / RS232 + communication interface slot Colour Dark grey (RAL 7035) Noise <45 dba at 1 m Accessories provided 2 cable guides; terminal board connection; software; serial cable; plastic keys to release display; handles kit Details Battery connection Serial port USB port Interface card slot SNMP or additional RS232 ports Input cable access Output cable access SXR

19 Sentinel XR Plus Sentinel XR Plus is the ideal solution for powering vital mission critical, sensitive loads such as electro-medical security applications in order to guarantee maximum reliability and availability. The series includes 5kVA-6kVA single/single phase and 6.5kVA-8kVA- 10kVA single/single phase and three/single phase models and uses double conversion on-line technology (VFI). The load is powered constantly by the inverter which supplies filtered, stabilised and regulated sinewave voltage. Moreover, the input and output filters increase the immunity of the load against mains power disturbances and lightning strikes. Sentinel XR Plus is without doubt one of the best UPS systems on the market today thanks to the technology used, the features (selectable Economy Mode and Smart Active Mode) and the diagnostics offered (custom LCD display, RS232 and USB interfaces complete with Watch&Save 3000 software, EPO contact and slots for optional interface boards). HIGH RELIABILITY Full microprocessor control. No break static and maintenance bypass. Features guaranteed up to 40 C (the components are designed to operate at high temperatures and thus are subject to less stress at ordinary temperatures). SELECTABLE OPERATING MODES The operating mode can be programmed using the software or selected manually on the digital front panel display. On line Mode (VFI). Economy Mode: increases efficiency (up to 98%), and uses Line Interactive (VI) technology to power low priority loads from the mains supply. Smart Active Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply. Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode). Frequency converter Mode (50 or 60 Hz). HIGH QUALITY OUTPUT VOLTAGE Even with distorting loads (IT loads with crest factor of up to 3:1). High short circuit current on bypass. High overload capacity: 150% on inverter, even when mains power fails. Filtered, stabilised and reliable voltage (double conversion on-line technology, VFI compliant with EN specifications, with filters to suppress atmospheric interference). Rephasing of the load: UPS input power factor close to 1 with sinusoidal current absorption. 48

20 SIMPLIFIED INSTALLATION The UPS can be connected to both single phase and three phase mains supplies. Output terminal board + 2 IEC plugs to power local equipment (computers, modems, etc.). Easy to move thanks to built-in wheels. HIGH BATTERY RELIABILITY Automatic and manual battery tests. Low Ripple Current Discharge system LRCD to prolong battery life. Unlimited extendable runtime thanks to dedicated modular design Battery Boxes. Increased ride-through for mains failures up to 40ms (high hold up time) and for fluctuations in the input voltage ranging from 84V to 276V). LOW IMPACT ON MAINS POWER Sinusoidal input current on single phase/single phase series. OTHER FEATURES Advanced diagnostics: status, measurements and alarms available on the custom LCD display. Very low noise level (<40dBA): for installation in any environment thanks to the PWM digitally controlled ventilation that is load dependent, and the use of an inverter with high switching frequency (>20kHz, value above the audible range). Autorestart when mains power returns, can be programmed using software or the digital front panel display. Emergency mode: the UPS can be programmed to work only when mains power fails (suitable for emergency lighting). Standard back feed protection: to avoid current being fed back into the mains system. Digital updating of the UPS (flash upgradable). ADVANCED COMMUNICATION Compatible with the AROS TeleNetGuard remote assistance system. Advanced, multiplatform communication for all operating systems and network environments: Watch&Save 3000 monitoring and shutdown software included, for Windows 2008, Vista, 2003, XP, Mac OS X, Sun Solaris, Linux, Novell and other Unix operating systems. RS232 serial port. Plug and Play connection. Slots for communication interface boards. APPLICATIONS Local Area Networks (LAN) Data Centers Servers Industrial PLCs Cash registers Electromedical devices Emergency devices (lights/alarms) Telecomunication devices 49

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication

More information

RIELLO ELETTRONICA. Master HP

RIELLO ELETTRONICA. Master HP RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES

More information

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase.

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase. LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro online UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase LOCAL AREA NETWORKS (LAN) INTERNET CENTERS (ISP/ASP/POP) ELECTRO-MEDICAL

More information

UPS Sentinel DUAL SDL

UPS Sentinel DUAL SDL Sentinel Dual is the new range of high density double onversion online, suitable for powering a wide range of devices such as servers, storage systems, telephony - VoIP equipment, network and medical systems

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications ZP110 on-line UPS 1, 2, 3, 6, 10kVA single/single phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs Emergency Devices (Lights/Alarms) Electro-Medical Devices

More information

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0 The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,

More information

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /

More information

30-120 3 Phase Modular Finally the benefits of Modular ups are for all

30-120 3 Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion

More information

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U

More information

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection

More information

LAP ENERGIA PARA DATACENTERS

LAP ENERGIA PARA DATACENTERS LAP ENERGIA PARA DATACENTERS Latin American Power. CABA, Argentina. 2 UPS INDOOR Latin American Power. CABA, Argentina. ALI ELITE SERIES Line Interactive UPS Tower/19 Rack Mount Versions 19 Rack Mount

More information

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB. Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V

More information

UNINTERRUPTIBLE POWER SUPPLY (UPS)

UNINTERRUPTIBLE POWER SUPPLY (UPS) Your Inspirations. Our Innovations. UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data CATALOGUE Revision 0 Table of Contents Table of Contents About Us - Company Profile Online UPS Professional

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications

More information

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES INDEX General characteristics page 4 Modular page 12 Conventional page 32 Line-interactive page 44 Communication

More information

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw Tender Technical Specification For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw 1 di 14 Index 1 GENERAL REQUIREMENTS... 4 1.1 SUBJECT AND AGREEMENT TYPE... 4 1.2 CONDITIONS... 4 2 GENERALI

More information

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine

More information

VISION UPS UPS PRODUCT CATALOGUE

VISION UPS UPS PRODUCT CATALOGUE VISION UPS UPS PRODUCT CATALOGUE 2012 1 VISION UPS Systems S. à r. l. About VISION UPS VISION UPS SYSTEMS S. à r. l. was established in 2003 by the two belgian UPS-specialists Patrick Willems and Ralph

More information

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine

More information

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR CLASSIFICATION CLASSIFICATION ACC. TO - AEG S UPS PRODUCT PORTFOLIO - IT S APPLICATION ORIENTED USE - UPS PRODUCT

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality

More information

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,

More information

Online UPS. PowerWalker VFI 1000R/1U

Online UPS. PowerWalker VFI 1000R/1U Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.

More information

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,

More information

4.0 UPS dedicated to ICT for unmatched energy savings

4.0 UPS dedicated to ICT for unmatched energy savings 4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.

More information

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling

More information

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMX750SLT Highlights 750VA line interactive tower UPS; Sine wave output 220/230/240V nominal

More information

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

3U, 2200 VA Audio/Video Pure Sine Wave UPS System 3U, 2200 VA Audio/Video Pure Sine Wave UPS System MODEL NUMBER: HTR22-3U Description Tripp Lite's HTR22-3U Pure Sine Wave 2200VA/1600W on-line, double-conversion UPS system prevents media data loss, equipment

More information

GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work GE Digital Energy TLE Series UPS 160-400 kw three phase 400 Vac with best-in-class efficiency gimagination at work GE provides clean, efficient and reliable power for today s digital world with the ultra

More information

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert

More information

Eaton 93PM UPS Where aesthetics meet intelligence.

Eaton 93PM UPS Where aesthetics meet intelligence. Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Model #: SMART2200CRMXL

Model #: SMART2200CRMXL Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for

More information

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA the Mega Power protection up to 5.4 MVA range is capable of a maximum system size of up to 5.4 MVA and specifically designed for demanding Data centre applications such as large DTC of banks / insurances,

More information

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output

More information

User Manual 1K/2K/3K Online UPS

User Manual 1K/2K/3K Online UPS User Manual 1K/2K/3K Online UPS Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation...

More information

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79

More information

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work GE Consumer & Industrial Power Protection Digital Energy LP Series UPS Uninterruptible Power Supply 3-30 kva GE imagination at work For more than a century, GE has led the way with innovative technologies

More information

USER MANUAL Online UPS 1K/2K/3K

USER MANUAL Online UPS 1K/2K/3K USER MANUAL EN Online UPS 1K/2K/3K Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1.1. Transportation 2 1.2. Preparation 2 1.3. Installation 2 1.4. Operation 2 1.5.

More information

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line

More information

Liebert APM from 30-150 kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert APM from 30-150 kw. The Compact Row-Based UPS With FlexPower Technology TM Liebert APM from 30-150 kw The Compact Row-Based UPS With FlexPower Technology TM Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,

More information

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V

More information

TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency

TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency GE Critical Power TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency imagination at work GE provides clean, efficient and reliable power for today s digital world with the

More information

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated

More information

USER MANUAL Online UPS 1K/2K/3K Rack

USER MANUAL Online UPS 1K/2K/3K Rack USER MANUAL EN Online UPS 1K/2K/3K Rack Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2

More information

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8

Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8 Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,

More information

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL

More information

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power

More information

MGE Galaxy 7000. 160/200/250/300/400/500 kva Power efficiency for business continuity

MGE Galaxy 7000. 160/200/250/300/400/500 kva Power efficiency for business continuity MGE Galaxy 7000 160/200/250/300/400/500 kva Power efficiency for business continuity Performance three-phase power protection with high adaptability to meet the unique requirements of medium to large data

More information

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS + Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

The UPS for the highest security in industry and data centres

The UPS for the highest security in industry and data centres The UPS for the highest security in industry and data centres P R E M I U M 6,000-20,000VA T E C H N O L O G Y www.online-usv.de Perfect: The ultimate protection against blackout and data loss The new

More information

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power

More information

GB USER S MANUAL GB 41

GB USER S MANUAL GB 41 GB USER S MANUAL GB 41 INTRODUCTION Thanks you for choosing this product of the DIALOG DUAL range. Riello UPS are renowned specialists in the development and production of uninterruptible power supplies

More information

Galaxy VM. Three-phase power protection. schneider-electric.com

Galaxy VM. Three-phase power protection. schneider-electric.com Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,

More information

Internet Office 500VA Tower Standby 120V UPS with USB port

Internet Office 500VA Tower Standby 120V UPS with USB port Internet Office 500VA Tower Standby 120V UPS with USB port MODEL NUMBER: INTERNETOFFICE500 Highlights 500VA tower 120V standby UPS Maintains AC output during power failures 3 UPS battery supported outlets,

More information

SG Series UPS 10-600 kva three phase 400 Vac

SG Series UPS 10-600 kva three phase 400 Vac GE Critical Power SG Series UPS 10-600 kva three phase 400 Vac with ultra-high efficiency eboost TM technology imagination at work From protecting assets such as generators, transmission lines and motors,

More information

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)

More information

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable

More information

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M Power Protection for Business Critical Continuity Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications Compact Three-phase UPS with Optimum Load Performance And

More information

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port Internet Office 750VA Ultra-compact Standby 120V UPS with USB port MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery supported

More information

NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL info@tuncmatik.com / www.tuncmatik.com Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3.

More information

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva 1. UPS definition... 2 1.1. Purpose... 2 1.2. Brief description... 2 2. Operating principles... 2 2.1. Normal operation...

More information

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA Liebert GXT3 is a full feature UPS providing reliable protection for IT network equipment and data centers. It is a true

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous

More information

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor

More information

TLE Series. Product Description. 160-200-320-400 kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

TLE Series. Product Description. 160-200-320-400 kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES TLE Series Product Description 160-200-320-400 kva / 400Vac / S1 KEY BEEFIT High efficiency up to 96.5% in on-line double conversion and 99% in eboost operation mode Unity output power factor; full power

More information

Smart-UPS On-Line 230 V

Smart-UPS On-Line 230 V Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide Smart-UPS

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of

More information

Technical Specification Kohler PW 5000/TP

Technical Specification Kohler PW 5000/TP Technical Specification Kohler PW 5000/TP Pioneering solutions for total power protection 2 UPS472-01-01 Kohler PW 5000/TP Technical Specification Dated 17-11-2011 Kohler PW 5000/TP SYSTEM DESCRIPTION

More information

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on Home Sign In View Cart Order Status Search Solutions Products and Services Support Your Business Company Data Center Server Rooms Solutions for Small-Medium Data Center Large Data Centers Cloud & Co-location

More information

Dell Smart-UPS 1,500 3,000 VA

Dell Smart-UPS 1,500 3,000 VA Dell Smart-UPS,00,000 VA 0 V Advanced line interactive power protection for servers and network equipment Reliable. Intelligent. Efficient. Manageable. Engineered by APC by Schneider Electric, the Dell

More information

Installation and Operation Back-UPS 1250, 1300, 1500

Installation and Operation Back-UPS 1250, 1300, 1500 Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with

More information

BC Pro UPS System Standby UPS System

BC Pro UPS System Standby UPS System BC Pro UPS System Standby UPS System Model #: BCPRO1400 1400VA standby, tower UPS system Offers battery derived AC output during blackouts and brownouts starting at 99V 6 protected AC outlets (NEMA 5-15R)

More information

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS. NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying

More information

GE Digital Energy. SG-CE Series UPS. 60-500 kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

GE Digital Energy. SG-CE Series UPS. 60-500 kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work GE Digital Energy SG-CE Series UPS 60-500 kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work From protecting assets such as generators, transmission lines and motors, to ensuring

More information

TECHNICAL SPECIFICHE SPECIFICATIONS MULTI DIALOG

TECHNICAL SPECIFICHE SPECIFICATIONS MULTI DIALOG TECHNICAL SPECIFICHE SPECIFICATIONS TECNICHE MULTI DIALOG 10-15-20kVA single-phase / single-phase 10-15-20kVA three-phase / single-phase 10-15-20-30-40-60-80kVA three-phase / three-phase On line double

More information

10000HXL31/15000HXL31/20000HXL31

10000HXL31/15000HXL31/20000HXL31 Table of Contents www.eaton.com/dxups USER MANUAL ON LINE UPS 10000HXL31/15000HXL31/20000HXL31 Uninterruptible Power Supply Table of Contents 1. Brief introduction 1.1 System and model description---------------------------------------------------------------------1

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality

More information

Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications 160-200 kva UPS

Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications 160-200 kva UPS Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications 160-200 kva UPS THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS

More information

Back-UPS Pro 1300/1500 Installation and Operation

Back-UPS Pro 1300/1500 Installation and Operation Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a

More information

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications W H I T E P A P E R Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications Executive Summary One of the fundamental decisions in the design of data centers, server rooms

More information

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)

More information

TLE Series UPS 225-1500 kw for best-in-class multi-mode operating efficiency

TLE Series UPS 225-1500 kw for best-in-class multi-mode operating efficiency TLE Series UPS 225-1500 kw for best-in-class multi-mode operating efficiency Ensuring Uptime for Critical Processes Mission-critical processes need a power system that is cleaner and more reliable than

More information

Power Quality Solutions up to 40 kva. UPS product catalogue

Power Quality Solutions up to 40 kva. UPS product catalogue Power Quality Solutions up to 40 kva UPS product catalogue Power Quality Contents Eaton Power Quality Division, a part of the Electrical Sector, has more than 45 years of experience in designing and producing

More information

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers CEMEP UPS The high environmental performance solution for power supply to high-availability data centers Exchanges of information and communication needs are growing at an exponential rate. That growth

More information

Internet Office UPS System Standby UPS for PCs, workstations and more

Internet Office UPS System Standby UPS for PCs, workstations and more Internet Office UPS System Standby UPS for PCs, workstations and more Model #: INTERNETOFFICE500 500VA standby tower UPS system Offers battery-derived AC output during blackouts and brownouts starting

More information