DEPARTMENT OF THE ARMY SUPPLY CATALOG SETS, KITS AND OUTFITS COMPONENT LIST/HAND RECEIPT MEDICAL EQUIPMENT SET GROUND AMBULANCE

Size: px
Start display at page:

Download "DEPARTMENT OF THE ARMY SUPPLY CATALOG SETS, KITS AND OUTFITS COMPONENT LIST/HAND RECEIPT MEDICAL EQUIPMENT SET GROUND AMBULANCE"

Transcription

1 *SC M72 DEPARTMENT OF THE ARMY SUPPLY CATALOG SETS, KITS AND OUTFITS COMPONENT LIST/HAND RECEIPT MEDICAL EQUIPMENT SET GROUND AMBULANCE NSN: LIN: M26413 *THIS PUBLICATION SUPERSEDES SC M72, DATED 30 MARCH 2004, INCLUDING ALL CHANGES HEADQUARTERS, DEPARTMENT OF THE ARMY 30 MAY 2006 DISTRIBUTION STATEMENT, A Approved for publication release; distribution is unlimited

2 SECTION I - INTRODUCTION 1. GENERAL. 3. RESPONSIBILITY. a. This catalog provides an alphabetical listing of Medical Equipment Set, Ground Ambulance.* b. The component listing/hand receipt is identified by a four-segment symbol: (1) The first segment (SC) indicates Supply Catalog. (2) The second segment (6545) identifies the Federal Supply Classification (FSC). (3) The third segment (8) identifies the compiler. (4) The fourth segment (M72) distinguishes the SKO from others in the same FSC. c. The title SKO is authorized by The Army Authorization Documents Systems (TAADS). d. The term SKO in the SC introduction will be replaced by the specific title for each SC (i.e., MES, DES, MMS, etc.). e. This Catalog is not an authorization for requisitioning NSN , Modification Table of Organization and Equipment (MTOE) or other Department of the Army (DA) authorization document(s).may requisition components listed in quantities indicated when the set is authorized. 2. PURPOSE. This SC provides initial allowances and quantities of supplies and equipment sets that provide initial supplies and equipment to initiate or maintain emergency resuscitation and provide emergency resupply to the medical aidman. This constitutes the minimum basic load to sustain this SC. *This publication supersedes SC M72 dated 30 March a. The Surgeon General (TSG) is responsible for the overall management of the Medical Equipment Sets (MES) and the Dental Equipment Sets (DES) for the Army and also approves the composition of the major MESIDES. Additionally, TSG is responsible for planning, programming, and budgeting for the initial issue of selected MESIDESs to the active Army and or all procurement-appropriation-funded medical equipment, regardless of whether it is in an initial issue or replacement. b. The U.S. Army Medical Department Center and School (USAMEDD C&S) designs, develops, and recommends the composition of MES/DES, Medical Supply Planning Modules (MSPM), and Optical Resupply Sets (ORSS). c. The U.S. Army Medical Materiel Agency (USAMMA) coordinates requirements with the Defense Supply Center Philadelphia (DSCP). The USAMMA also performs staffmanagement actions as directed by TSG and as outlined in AR ** d. In conjunction with the Army Medical Department Center and School (AMEDD C&S), Directorate of Combat and Doctrine Development, the USAMMA develops the requirements. The OTSG coordinates programming and budgeting from the proper appropriation (OMA, OMAR, OMNG, OPA, or Stock Fund) for procurement of newly developed or significantly revised MES/DES and for Associated Support Items of Equipment (ASIOE). e. After initial fielding, MACOMs (in addition to OCAR and the ARNG) are responsible for follow-up requisitioning, storing, and maintaining those MES/DES and equipment authorized to be on-hand in TOE units or TDA activities. MACOMs program and budget for replacement of consumable and expense equipment components, and for minor changes to MES/DES on hand at TOE units. **Reference AR dated 25 January 1995, Section I, Abbreviations Glossary.

3 a 5' m cn a, ~ 7 < urn m S 3 -. n SELm,cnm rn 0 zn P E$j 0 3;- 0 j;~ $. 2 m m =3 E. 33 G 7w3 E3 m m p 25" 5 = 2. n ru g. a, c a 0 2 ~2 " s: EL-. m 3 a ZDg'Vr C s 8 gu a pa: :..a2 3 3 g(d= a* fi ZV W zfeg2 Ea - 3"- c,230 (y Ln 0 n G. 2 n 3 u m ' " 5 a gga: 9 - zg5'zx a* E.-, 3 YS# 3% "' A m m o n E 2DBo3 p:s3s '0 0 3'0 (Dcno e2.24 crh 38% "' 3.p CI % ( D m V y EEx 73 g

4 SECTION I - INTRODUCTION, n d. RMKS (REMARKS). Space reserved for notes, which g. UI (UNIT OF ISSUE). This is a two-position code that are explained in the "Special Information" paragraph. shows the smallest quantity that an item can be requisitioned and issued. e. ARC (ACCOUNTING REQUIREMENTS CODE). This is a one-position alphabetic code that identifies the way an item is h. QTY AUTH (QUANTTPI AUTHORIZED). This is the accounted for by the Army. One of the following codes must be quantity authorized to be on hand for each end item or entered here. component of an end item. N - NONEXPENDABLE D - DURABLE X - EXPENDABLE This code identifies items, which are not used up and keep their identity throughout their life and must be accounted for in the properly book. This code identifies items that are not used up. These items keep their identity throughout their life. Items identified by this code are accounted for by hand receipt or other similar document. This code identifies items that will be used up. These items do not need to be entered on hand receipts; however, preprinted hand receipts list expendable items for information purposes only. f. CIIC (CONTROLLED ITEM INVENTORY CODE). This is a oneposition alphabeticlnumeric code that indicates the security classification, security risk, or pilferage controls required for storage and transportation of DOD assets. DA PAM identifies those items that must be inventoried monthly. The CIIC code applicable to components of this SC unless othenvise indicated in the CIIC column, is U (UNCLASSIFIED). i. QUANTITY ON HAND (A Thru F). These columns are for the actual quantity on hand for each component listed. 5. ABBREVIATIONS: Standard abbreviations are listed in AR (Authorized Abbreviations and Brevity Codes) and the DoD Medical Catalog, Introduction (Authorized Abbreviations Referenced to Terms). Some words will be truncated (with vowels removed that do not meet the above references) in order to fit a limited-space nomenclature field. Army acronyms used in this SC are defined in AR 40-61, Glossary, Section I Abbreviations. Nonstandard abbreviations used in this publication are given in the following lists:

5 SECTION I - INTRODUCTION Abbreviation Explanation ABS ABSORB AC ACET ACR ACRY ADH AD3 ADL ADMIN ADU AE AERS AHP AL ALC ALUM AMPS ANALYZ AN AS ANER ANES ANG ANGIO ANGLD AORT APP APPAR APPROX APPRX ARM ASIF ASST AUTO AUTOCL BACITR BAL BAND Absorbent, Absorbable Absorbable Alternating Current Acetate Acrylic Acrylic Adhesive, Adhere Adjustable Adult Administration Adjustable Antiembolism Aerosol Angle Handpiece Aluminum, Alloy Alcohol Aluminum Amperes Analyzer Anastomosis Aneroid Anesthesia Angle Angioplasty Angled Aorta Apparatus Apparatus Approximately Approximately Armed Association For The Study of Internal Fixation Assortment Automatic Automatic Closure Autoclavable Bacitracin Balloon Bandage BAT BAT CHAR BAT/OP BEVL BIO BIOLOG BICAR BIU BIUR BLD BLDE BLK BLN BNK BR BRST BT C C2 CAL CAP CAPS CARB CARD10 CART CART-NDL CAS CASS CAT CATH CATH&NDL CATH-TUBE CH CHAM CHAM6 CHEM CHI-ADU CHL CHLD CHLORAM Battery Battery Charger Battery Operated Bevel Biological Biological Bicarbonate Bilitubin Bilirubin Blood Blade Black Blunt Bank Braided Breast Bottle Celsius, Cycle, Centigrade Carbon Dioxide Calcium Capsule, Capacity Capsules Carbide Cardiovascular Cartridge Cartridge Needle Cassette Cassette Catheter Catheter Catheter and Needle Catheter-Tu be Child Chamber Chamber Chemical Child-Adult Chloride Child Chlorarnphenicol

6 INTRODUCTION! Abbreviation Explanation Abbreviation Explanation CHLORAME CHRM CIR CUN CUNDAMY CLO CLR CM COL COLL COLLECn COMB COMP CONCEN CONN CONSEC COT CR CRES CRM CRS CRVD CS CTN CU CULT CUSH CVD CVR CVRS CYL CYUN D D A DARKRM DBL DC DEG DEN DENT Chloramphenicol Chrome Circle Clinical Clindamycin Closure Clear Centimeter Collecting Collection, Collect Collecting Combination Compressor Concentration Connector Consecutive Cotton Cream Crescent Corrosion-Resisting Metal Corrosion-Resisting Steel Curved Carbon Steel Cotton Cubic Culture Cushion Curved Cover Covers Cylinder, Cycle, Cylindrical Cylindrical Deep Double Armed Darkroom Double Direct Current Degree Dental Dental DEPMEDS DES DET DETACH DETERG DEVEL DEX DFLCTNG DIA DIAG DIAGN DFLCTNG DILUT DIS DISP DISPO DISPEN DISPSNERS DP DRESS EA ECG ELAS ELEC EDTA EKG ELECTROSURG ENDOTRAC ENDOTRACH ENE EPIN EQ EQUI EQUIP EQUIV ERYTHROM EX EXAME EXP Deployable Medical Systems Dental Equipment Set Detachable Detachable Detergent Developer Dexamethasone Deflecting Diameter Diagnostic, Diagonal Diagnostic Deflecting Diluting Disposable Disposable Disposable Dispensers Dispensers Deep, Durable Press Dressing Each Electrocardiogram Elastic Electric Ethylenediaminetetra Acetic Acid Electrocardiogram Electrosurgical Endotrachael Endotrachael Enema Epinephrine Equivalent Equivalent Equipment Equivalent Erythromycin Examining Examining Explosion

7 SECTION I - INTRODUCTION Abbreviation EXT F/ FAB FABRCTN F/ALL FED FIB FILT nx FL FLD FLEX FLM FLR FNGR FOLD FRICT FOUNT FR FRM FT FST F/SZ G A GAL GEL GEN GL GLA GLAS GLU GM GMS GP GRA GRP GYN Explanation Extension, Extra For Fabrication Fabrication For All Federal Fiber Filter Fixer, Fixed fluid Field Flexible Film Floor Finger Folding Friction Fountain French Form FeeVFoot Fastener For Size Gage Gallon Gelatin General Gallon Glass Glass Glucose Gram Grams General Purpose Gramicidin Group Gynecology H HCL HEM0 HEXAG HG HI HNDL HNDPC HOR HORIZ HOSP HRS HTD HYDROCOR HYDROX HYP HYPO HZ I ID IUUM IMP IMPRE IN IND INDI INDIC INF INF-CH-AD INFO INJ INS INST INSTR INSUL INTERMIT INTRA INTRAVEN INTRO INVER High Hydrochloride Haemostatic Hexagonal Height High/Highly Handle Hand piece Horizontal Horizontal Hospital Hours Heated Hydrocortisone Hydroxide Hypodermic Hypodermic Hertz Inch Inside Diameter / Identification Illuminator Impregnated Impregnated Inch, Injection Individually/Individual Indicating Indicating Infant Infant-Child-Adult Information Injection Inserts Instrument Instrument(s) Insulated Intermittent Intravenous Intravenous Introduction Inverted

8 SECTION I - INTRODUCTION, Abbreviation Explanation Abbreviation Explanation INW IOTHALA I.S. IS0 IV KET KG KILO KT L LAB LACT LG LGTH U UQ LO LPM LRG LRGE LSE LT M MACH MAG MAGNES MAN MATL MAX MCG MCGM MECH MED MEDROXYPR MEG M EQ MER Inch Wide Iothalamate Individually Sealed Isopropyl Intravenous Ketone(s) Kilogram Kilogram Kit Long Laboratory Lactated Length, Long, Large Length Liter Liquid Low Liters Per Minute Large Large Leaf Light Meter Machine Magnesium Magnesium Manual Materials Maximum Microgram Microgram Mechanical/Mechanic Medium, Medical, Medicinal Medroxyprogesterone Megetholate Milliequivalents Mercury MERC MERTH-OD-FORM M ETR MG MICON MICROSURG MIN MISS MIX M L MM MODIF MONIT MONO MR MT MTD NAS NASOPHAR NDL NEG NF NIT NITR N LD NO NONADJ NONABS NONAUTO NONAUTOCL NONCORR NONFLAM NONSTER NONWOV NONWVN NORM NYST 0 B OCCU Mercury Merthiolate-Iodine-Formalin Metered Milligram Miconazole Microsurgery Minimum, Minute Medical Instrument Supply Set Mixing Milliliter Millimeter Modified Monitor Monofilament Meter Mount Mounted Nasal Nasopharyngeal Needle Negative National Formulary Nitrate Nitrite, Nitrate Needle Number Nonadjustable Nonabsorbable, Nonabsorbent Nonautoclavable Nonautoclavable Noncorrosive Nonflammable Nonsterile Nonwoven Nonwoven Normal Nystatin Obstetrical Occlusion

9 Abbreviation Explanation SECTION I - INTRODUCTION Abbreviation OID OD OP OIN OINT OPER OPHTH OPNG OPT O.R. ORAN ORTHO OSCILL o/r OW oz P2 PAPR PAR PAT PDWR PED PG PH PHARYN PHENYLEP PHENYLPRO PHOS PL PLAS PLTD PLYSTR PNEU POLY POLYGL POLYMY POLYPROP POLYUR POR POS Outside Diameter Outside Diameter, Olive Drab Operated, Open Ointment Ointment Operatedloperating Ophthalmic Opening Optic Operating Room Oranasal Orthopedic Oscillations Outlet Oxygen Ounce Oxygen / Partial Pressure Paper Partial Patient Powder Pediatric Package Potential Hydrogen Pharyngeal Phenylephrine Phenylpropanolamine Phosphate Plus, Plated Plastic Plated Polyester Pneumatic Polyester, Polyurethane, Polyethylene, Polyglycolic, Polygladin Polymyxin Polypropylene Polyurethane Portable Positive, Position POSTOP POT POVIDONE-IOD POV-IOD PR PREP PRES PRF PRIM PROC PROCH PROHIB PROT PROTECT PRTBLE PRTO PSI PT FTBL ms UR PURP PWDR RAD RADGR RADIO RADIOP R-ANG RAY RBBR RD REAG REC RECEP RECIP RECT REF Post Operative Potassium Povidone-Iodine Povidone-Iodine Pair Preparation Pressure Proof Primary Procedure Prochlorperazine Prohibits Protein Protective Portable Protein Pounds Per Square Inch Pint, Points Portable Points Purpose Purpose Powder Sufficient Quantity Quart Radiological Radiographic Radiopaque, Radiological Radiopaque Right Angle Rayon Rubber Round, Radiographic Reagent Rectal Receptacle Reciprocating, Reciprocation Rectal Refrigerator

10 SECTION I - INTRODUCTION! Abbreviation Explanation Abbreviation Explanation REFRIG REG REINF REMOV RES RESP REV REVERS RH RNG RO RPM RUB RUBB S A SE SEA SEAL SEL SEN SENS SENSI SEP SERA SET sm SGL SH SHPE SIL SIMETH SM SML SMPL SNG SOD SOL SPD Refrigeration, Refrigerator Regular, Regulator Reinforced Removable Rest Respiratory Reverse Reversible Rhodium Ring Roll Revolutions Per Minute, Rotations Per Minute Rubber Rubber Single- Armed Set Sealed Sealed Self Sensitive Sensitive Sensitive Separate Serum Setting Safety Single Sheet Shaped, Shape Silicone Simethicone Small Small Sample Single Sodium Solution, Soluble Speed SPEC SPHER SPHYGMO SQ SS STD STER STERIL STERLZR STETHO STL STR SUBNORM sum SUL SULF SUPOS SURG SURGY SUS SUST REL SUT SYN SY NTH SYR SYR NO1 SYS sz TABS TEMP TENN TERM TH TH K TH R TOW TP TRACH Specimen Spherical Sphygmomanometer Square Stainless Steel Standard Sterile, Sterilize, Sterilizing, Sterilized Sterilization Sterilizer Stethoscope Steel Strength, Straight Subnormal Suction Sulfate Sulfate Suppositories Surgical, Surgery Surgery Suspension Sustained Release Suture Synthetic Synthetic Syringe Syringe Needle System Size Tablets Temperature Tennessee Terminal Thick Thick Thread Towel Tip Tracheal, Tracheotomy

11 SECTION I - INTRODUCTION Abbreviation Explanation TREAT TUNGS PI Treatment Tungsten TY pe VERT VET VS Vertical Veterinary Venus U U N UNC UNF U RE U RETH UNIV UNIVER URIN UROBIL USP v VAG VAL V AR VIS VOL VENT Univenity Unit Unified National Coarse Unified National Fine Urethral Urethral Universal Universal Urinalysis Urobilinogen United States Pharmacopoeia Volt(s) Vaginal Valve Variable Visual Volume Vented W/FLEX W/HDL WHL w/o w/ W W/BAT-CHAR WBC WD W/SEP M WVN X XLGE XLR With Flexible With Handle Whole Without With WideIWatts, Wide, With With't3attery Charger White Blood Cell Wide With Separate Weight Woven Extra Extra Large Extra Large

12 6. SPECIAL INFORMATION. a. The items listed in Section I11 of this SC beginning with Page are ASIOE end items dedicated to the operation andlor maintenance of this medicalldental assemblage. b. ASIOE are separately documented into TOEphe Army Authorization Documents System (TAADS) and are not to be considered components of this medicalldental assemblage. SECTION I - INTRODUCTION, F G Subject to Damage by Freezing -. Requires refrigeration between 2 degrees to 8 degrees Centigrade (35 degrees to 46 degrees Fahrenheit) I Flammable or Oxidizing P Potency-Type Items n NOTE: This SC does not have a Section 111. c. They are listed In this section for information purposes only and do not constitute an additional authorization. Total authorization is reflected on the Unit's.MTOE. d. To assist physicians in prescribing items initially supplied with this set, a Therapeutic Index constructed in accordance with the American Hospital Formulary Service (AHFS) is provided in section IV. The Therapeutic Index may not be required for all SCs. This index lists the FSC 6505 components of the major assemblage with a therapeutic classification in NSN sequence within each therapeutic class. NOTE: This SC does not have a Section IV. e. Permission to use the Pharmacological-Therapeutic Classification Systems of the AHFS has been granted by the American Society of Hospital Pharmacists. The Society is not responsible for the accuracy of transpositions, or additions, or excerpts from the original context. For complete information concerning all drugs, consult the AHFS, copyright , American Society of Hospital Pharmacists, Inc., All Rights Reserved. f. REMARKS COLUMN: The symbols shown in the Remarks Column apply to this SC only and include the following: g. COMPONENTS LISTINGS. (1) To support Army Medical Department Activities, the USAMMA also provides disks for UA component listings in lieu of hard-copy versions. For each UA requested, the disk will consist of UA information contained in the following ways: - TexVraw data file, - Report File (which is in the same four-section format as the current hard-copy component listing), and - An Excel file. A brief instruction guide on "How to Access and Print the Information" is included on the disk. This guide contains the data record layout of the Text file allowing the user to merge the data with existing software of either Lotus or Access. (2) Activities that have automated capabilities and choose the disk method, should send their complete address and UIC along with all UAs authorized under that UIC to: Commander U.S. Army Medical Materiel Agency ATTN: MCMR-MMO-AS 1423 Sultan Dr., Suite 100 Fort Detrick MD

13 SECTION I - INTRODUCTION (3) Component authorizations are published in medical!i materiel set computer listings available from the USAMMA and ' i. SECnON VI - NSNS DELMD FROM PREVIOUS in the appropriate supply catalog (SC Series). PUBLICATIONS AND APPLICABLE REPLACEMENTS. Revisions to components are published on the USAMMA web site - (1) This Section, if applicable, appears in all editions subsequent to the initial edition of the Supply Catalog. (4) Publication of current component set authorizations constitutes authority for updating assemblages in (2) It includes all deletions and replacements made respective units and serves as the authorization document of to Section I1 since the previous edition. assemblage components. (5) Commanders of DEPMEDS Units will continue to utilize the UA list initially fielded with the unit until authorized for update by the USAMMA. This may result in the use of several UA listings with different dates for different assemblages until a new upgrade of the set is provided by the USAMMA. (6) Commanders who do not have automated capabilities and need the hard copy listings should continue to request a current-ua listing by submitting requests through to: usammacrrn@amedd.army.mil or writing to: Commander U.S. Army Medical Materiel Agency AlTN: MCMR-MMO-AS Fort Detrick MD Telephone DSN COMM The request should identify the specific NSN for medical set(s) required. In addition on the request, you may also identify the UA, Nomenclature, or UN. h. AMDF INCOMPATIBILITIES. If catalog incompatibilities are discovered between this publication and the AMDF (Army Master Data File), the latter will govern. 7. ACCOUNTABILITY. a. Page , Section I1 (FROM:) identifies the element from which the property is issued. Enter the name of the organization, unit, section, or squad that issues the property. b. The block (TO:) identifies the element to which the property is issued. Enter the name and rank of the person receiving the property. TOE/MTOE paragraph, line number, and job title may be added as optional information. c. HAND RECEIPT NUMBER: Enter a locally assigned number. d. END ITEM STOCK NUMBER: Enter the NSN of the MES/DES. e. END ITEM DESCRIPTION: Enter a short description of the MES/DES. f. PUBUCATION NUMBER: SC Number. g. PUBUCATION DATE: SC Effective Date. h. QUANTITY ON HAND: These columns are for the actual quantity on hand for each component listed. (1) Enter the quantity on-hand for each component listed. Line out all unused blocks in columns with recorded quantities.

14 (2) Advance all quantities to the next column when quantities change. Quantities must be advanced when changing hand-receipt holders. (3) The person receiving the property will sign, enter his/her rank, and date the proper quantity column on the last page (ink entry). The last page is the last-numbered page and may be an odd or even number. The last page may be reserved for signature only. (The original page will have an original signature; the copy may have a duplicate/reproduced signature.) SECTION I - INTRODUCTION 9. POWER REQUIREMENTS. An external power source is required to support this MES/DES. The following NSNs operate on 115V, single-phase power with wattage requirements as shown: NSN ITEM WAlTS VOLTS Suction App , Surgical Prog, Batt, ll-30v or AC 120 PRTBLE n 8. TRANSPORTATION INFORMATION. a. Supplies will be packed in containers suitable for operations under field conditions. b. Packages or containers will ordinarily be of such size and weight as to permit the required handling c. When practicable, crating will be such as to permit equipment to be readily accessible by removing the front, side, or top of the container. d. To reduce the overall bulk when this assemblage is packed by the Depot, any empty chests that appear as components on the equipment list will be utilized wherever possible as shipping containers. e. The following information is applicable to this MESIDES. Total Weight and Volume of this MES/DES: Weight: Volume: REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS. a. You can help improve this publication. If you find any grammatical or publishing mistakes, please let us know. Mail your letter or DA Form 2028 (Recommended Changes to Publication and Blank Forms) direct to: Commander US Army Medical Materiel Agency ATTN: MCMR-MMO-AS 1423 Sultan Dr., Suite 100 Fort Detrick MD or via to: usammacrm@amedd.armv.mil b. To recommend any additions or changes to the set components, you must also submit the DA Form Mail the Form, to include justification, to: Commander, AMEDD Center and School ATTN: MCCS FC 1400 East Grayson ST Fort Sam Houston TX (1-014 blank)

15 SECIION 11: ILLUSTRATED COMPONENT USTIHAND RECEIPT

16

17 SECTION II. ILLUSTRATED COMPONENT LlSTlHAND RECEIPT FOR USE OF THIS HAND RECEIPT SEE SECTION I. From: To: Hand Receipt No: END ITEM STOCK NUMBER ITEM DESCRIPTION PUBLICATION NUMBER PUBLICATION DATE QUANTITY MES GROUND AMBULAN SC M72 10 Feb 06 ILL. ACT STOCKNUMBER NO ITEM DESCRIPTION RMKS ARC CllC UI QTYAUT MEDICAL EQUIPMENT SET GROUND N U EA 1.OO AMBULANCE: QUANTITY ON HAND A B C D E 3256 M PUMP INTRAVENOUS INFUSION MINI RAPID N U EA 1.OO IV I CNTO SUCTION APPARATUS SURG N U EA 1.OO PROGRAMMABLE BAlTERY 1 I-3OV OR AC PRTBLE BLANKET BED WOOL OLIVE GREEN 90x66 D U EA 8.00 INCHES MIL N CABLE POWER 120" LG D U EA 2.00 lqrkl TA-CDC CASE HOSPITAL LINENS SMALL CANVAS D U EA 1.OO MILCOO16489 N CASE,MEDICAL INSTRUMENT & SUPPLY D U EA 2.00 SET #3 OLIVE DRAB 30X18X10 ID

18 ILL. NO ILL. NO ILL. NO NOT ILLUSTRATED ILL. NO ILL. NO ILL. NO

19 SECTION II. ILLUSTRATED COMPONENT LISTHAND RECEIPT FOR USE OF THIS HAND RECEIPT SEE SECTION I. From: To: Hand Receipt No: END ITEM STOCK NUMBER ITEM DESCRIPTION PUBLICATION NUMBER PUBLICATION DATE QUANTITY MES GROUND AMBULAN SC M72 10 Feb 06 ILL. ACT STOCK NUMBER NO ITEM DESCRIPTION RMKS ARC CllC UI QTY AUT N CHARGER BATTERY TA-CAC 2.5"X 4.25"X D U EA " AUTO SHUT OFF QUANTITY ON HAND A B C D E 1QRKl TA-CAC FORCEPS HEM0 PEAN DESIGN SLIGHTLY D U EA 2.00 CURVED JAW 9'01A LG CRS OXIMETER PULSE FINGER PULSE D U EA 2.00 OXIMETER SELF CONTAINED OSCH REGULATOROXYGENPRESSURE D U EA 2.00 LIGHTWEIGHT WllNTEGRAL FLOW CONTROLLER RESCUE AND TRANSPORT SYSTEM D U EA 1.OO PATIENT BASIC HIGH DENSITY SHEET&ACC SK RESUSCITATOR HAND OPERATED HAND D 7 EA 1.OO PUMP PORTABLE IN CARRYING CASE SAW FINGER RING.75"BLADE DIA 6"LG D U EA 1.OO " ARBOR HOLE DIAMETER 07TA6 BD

20

21 SECTION II. ILLUSTRATED COMPONENT LISTIHAND RECEIPT FOR USE OF THIS HAND RECEIPT SEE SECTION I. From: To: Hand Receipt No: END ITEM STOCK NUMBER ITEM DESCRIPTION PUBLICATION NUMBER PUBLICATION DATE QUANTITY MES GROUND AMBULAN SC M72 10 Feb 06 ILL. ACT STOCKNUMBER NO ITEM DESCRIPTION RMKS ARC CllC UI QTYAUT SCISSORS BANDAGE 7.25" LG ANG TO HDL D U EA " CUT LG BLUNT PTS CRS QUANTITY ON HAND A B C D E 7P522 BC SCISSORS GEN SURG 5.50' LG ONE BLUNT D U EA 1.OO AND ONE SHARP BLADE PT CRS 1H SPHYGMOMANOMETER ANEROID 300MM D U EA 1.OO MAX CALIBRATION WlCLlP FOR CUFF MX STRAP WEBBING PATIENT SECURING D U EA BUCKLE WlLOCKlNG DEVICE 8 SPRING 056F9 STRAP, WEBBING TRACTION APPARATUS KENDRICK D U EA 2.00 FllMMOBlLlZATlON OF FEMORAL FRACTURE 06ST ADHESIVE TAPE SURGICAL RAYON BASIC P X U RO 1 00 WHITE 3" WIDE 10 YDS OZSM5 TRM ADHESIVE TAPE SURGICAL RUBBER P X U PG 2.00 SYNTHETIC COATING WHITE 1"XlOYD 2s OZSM5 TRM3231A02

22 NOT ILLUSTRATED NOT ILLUSTRATED NOT ILLUSTRATED NOT ILLUSTRATED NOT ILLUSTRATED NOT ILLUSTRATED NOT ILLUSTRATED

23 SECTION II. ILLUSTRATED COMPONENT LISTIHAND RECEIPT FOR USE OF THIS HAND RECEIPT SEE SECTION I. From: To: Hand Receipt No: END ITEM STOCK NUMBER ITEM DESCRIPTION PUBLICATION NUMBER PUBLICATION DATE QUANTITY MES GROUND AMBULAN SC M72 10 Feb 06 ILL. QUANTITY ON HAND ACT STOCKNUMBER NO ITEM DESCRIPTION RMKS ARC CllC UI QTYAUT A B C D E ADMINISTRATION SET INFUSION PUMP X U PG 4.00 VENTEDNNVENTED E AIRWAY NASOPHARYNGEAL 6MM ID 8MM X U PG 1.OO OD SMOOTH RD EDGES PLAS DlSPlOS AIRWAY NASOPHARYNGEAL 9MM ID 12MM X U PG 1.OO OD KINK RES SMOOTH RD EDGESlOS ATROPINE INJECTION AQUEOUS TYPE P X J EA ML SYRINGE WITH NEEDLE ATROPINE INJECTION BAG STERILIZATION BIOHALARD DlSP X U PG 2.00 ORANGE POLY A4 FLAT 34x25" 10s OZSM5 TRM BANDAGE ADHESIVE.75 X 3" STERILE P X U PG FLESH 6s OZSM5 TRM BANDAGE ELASTIC FLESH ROLLED P X U PG 1 00 NONSTERILE 6"X 4.5 YDS 12s

24

25 SECTION 11. ILLUSTRATED COMPONENT LISTIHANQRECEIPT FOR USE OF THIS HAND From: To: Hand Receipt No: END ITEM STOCK NUMBER ITEM DESCRIPTION PUBLICATION NUMBER PUBLICATION DATE QUANTITY MES GROUND AMBULAN SC M72 10 Feb 06 ILL. ACT STOCKNUMBER NO ITEM DESCRIPTION RMKS ARC CllC UI QTYAUT BANDAGE GAUZE 6 PLY WHITE 4.5" WIDE 4 P X U PG 8.00 YDS LONG STERILE 6s QUANTITY ON HAND A B C D E OZSM5 TRM BANDAGE MUSLIN COMPRESSED OLIVE X U EA DRAB37X37X52" TRIANG WlSFTY PINS 5R BASIN WASH RECTANG 7QT LIGHTWEIGHT X U PD 2.00 SOAKING FOREARM ELBOW FOOT 2s OZSM5 TRMH BATTERY NONRECHARGEABLE ALKALINE P X J PG 1.OO AA 1.5V 1 YEAR SHELF LIFE 24s NEDA 15A BATTERY NONRECHARGEABLE ALKALINE P X J PG 1.OO AAA 1.5V 12lPACKAGE N BATTERY PACK RECHARGEABLE 12V 6.69"X X U EA "X 5.0" E lqrkl TA-BCE BLANKET CASUALTY PLAS ALUM COATED X U EA X561NCHES GREEN TAPED MIL-B

26

27 SECTION II. ILLUSTRATED COMPONENT LISTHAND RECEIPT FOR USE OF THIS HAND RECEIPT SEE SECTION I. From: To: Hand Receipt No: END ITEM STOCK NUMBER ITEM DESCRIPTION PUBLICATION NUMBER PUBLICATION DATE QUANTITY MES GROUND AMBULAN SC 6545&M72 10 Feb 06 ILL. QUANTITY ON HAND r ACT STOCKNUMBER NO ITEM DESCRIPTION RMKS ARC CllC U1 QTYAUT A B C D E BLOOD-FLUID WARMER SYS DlSP 9"X 2.8"X X U EA " UNV lqrkl TA CARTRIDGE PUMP STER DIS P X U EA 1.OO CRYSTALLOIDLCOLLOID W/ CNTO CASE SPHYGMOMANOMETER 8X4.50X2.50" X J EA 1.OO CATHER & NDL UNIT Dl2 IV 14GX1.25" 2" P X U PG 6.00 NLD CLR FLASH CHAMBER 4s OZSM5 TRM CATHETER & CONNEC SUCT TRACH El4 18 P X U PG 3.00 FR WHISTLE TIP 2 EYES MAS 5s OZSM5 TRM CATHETER & NDL UNIT Dl2 IV ANGIOCATH X J PG 1.OO 20GA CATH 23GA NDL STER 50s 07TA CATHETER & NEEDLE UNIT Dl2 IV 18GA X U PG 1 00 NDL 1.25" CATH LG TAN STER50S

28

29 SECTION II. ILLUSTRATED COMPONENT LISTMAND RECEIPT FOR USE OF THIS HAND RECEIPT SEE SECTION I. From: To: Hand Receipt No: END ITEM STOCK NUMBER ITEM DESCRIPTION PUBLICATION NUMBER PUBLICATION DATE QUANTITY MES GROUND AMBULAN SC M72 10 Feb 06 ILL. QUANTITY ON HAND & ACT STOCKNUMBER NO ITEM DESCRIPTION RMKS ARC CllC UI QTYAUT A B C D E CONNECTOR TUBING STRAIGHT 3.5 IN LG X U EA IN INSIDE DIA 1 PER PG OZSM5 TRM350AOl DEPRESSOR TONGUE 6X0.75X0.062" P X U PG 1.OO STRAIGHT 1 OOS 5L DIAZEPAM INJECTION USP SMGIML 2 ML PQ X Q PG 2.00 UNIT 10 PER PACKAGE 3VBU6 NDC DISPOSAL CONTAINER NDLE 3.YX3.5" 1" X U EA 2.00 OPENING RED PUNCTURE RESIST OZSM5 WIN DRESSING FIRST AID FIELD CAMOUFLAGED X U EA "W "LG ABS CAMOUFlAGED.11-3MIN. S DRESSING FIRST AID FLD CAMOUFLAGED X U EA X4" COMPRESS STER 5R542 CAMOUFLAGED,4 X 7 IN. IN R DRESSING PRESSURE PAD COTTON 7.5X8" P X U EA STERILE LATEX FREE 06UE

Enables MDA Medical Teams to categorize victims in mass casualty scenarios, in order to be able to triage and treat casualties

Enables MDA Medical Teams to categorize victims in mass casualty scenarios, in order to be able to triage and treat casualties MDA Disposable ALS + BLS Medical Ambulance Equipment Prices shown in CDN. Funds Items Description Picture Mass Casualty ID tag 1000 units = $350 Enables MDA Medical Teams to categorize victims in mass

More information

SUBJECT: BASIC LIFE SUPPORT AMBULANCE EQUIPMENT REFERENCE NO. 710

SUBJECT: BASIC LIFE SUPPORT AMBULANCE EQUIPMENT REFERENCE NO. 710 SUBJECT: BASIC LIFE SUPPORT AMBULANCE EQUIPMENT REFERENCE NO. 70 POLICY: NOTE: Ambulances dedicated for infant transportation or when staffed and equipped for use in conjunction with newborn intensive

More information

Excel Invoice Format. SupplierWebsite - Excel Invoice Upload. Data Element Definition UCLA Supplier website (Rev. July 9, 2013)

Excel Invoice Format. SupplierWebsite - Excel Invoice Upload. Data Element Definition UCLA Supplier website (Rev. July 9, 2013) Excel Invoice Format Excel Column Name Cell Format Notes Campus* Supplier Number* Invoice Number* Order Number* Invoice Date* Total Invoice Amount* Total Sales Tax Amount* Discount Amount Discount Percent

More information

PENNSYLVANIA DEPARTMENT OF HEALTH EMERGENCY MEDICAL SERVICES OFFICE. Vehicle # ALS Mobile Care and BLS Inspection Checklist

PENNSYLVANIA DEPARTMENT OF HEALTH EMERGENCY MEDICAL SERVICES OFFICE. Vehicle # ALS Mobile Care and BLS Inspection Checklist PENNSYLVANIA DEPARTMENT OF HEALTH EMERGENCY MEDICAL SERVICES OFFICE Vehicle # ALS Mobile Care and BLS Inspection Checklist I. GENERAL INFORMATION: Date Stickers: Yes No Decals: Yes No Name of Ambulance

More information

NCCEP Standards. NCCEP Standards for EMS Equipment

NCCEP Standards. NCCEP Standards for EMS Equipment NCCEP Standards NCCEP Standards for EMS Equipment Performance Standards 2009 . The baseline equipment required in all systems (including Specialty Care Transport Programs) with EMS personnel credentialed

More information

SECTION OF EMERGENCY MEDICAL SERVICES MINIMUM REQUIRED EQUIPMENT LIST PARAMEDIC

SECTION OF EMERGENCY MEDICAL SERVICES MINIMUM REQUIRED EQUIPMENT LIST PARAMEDIC MINIMUM REQUIRED EQUIPMENT LIST PARAMEDIC Trauma Dressing (2) Isolation Kits (2) OB Kit (1) - must contain Bulb syringe Betadine Solution (1 Bottle) Hemostat Window Punch Scalpel Exam Gloves (1 Box) Sterile

More information

Procedure Code A4215 22 Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external

Procedure Code A4215 22 Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external A4215 22 Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external insulin pump, needle type A4232 Syringe with needle for external insulin

More information

Anesthesia Products Needles. Anesthesia Products Trays. Antimicrobial Products. Hypodermic/Diabetes Care Products. Hypodermic/Reusable Products

Anesthesia Products Needles. Anesthesia Products Trays. Antimicrobial Products. Hypodermic/Diabetes Care Products. Hypodermic/Reusable Products 2014 2015 Sections A1 A2 B C D E F G H I J K L M Anesthesia Products Needles Anesthesia Products Trays Antimicrobial Products Flush Products Hypodermic/Diabetes Care Products Hypodermic/Reusable Products

More information

SECTION. BD Medical Anesthesia Products - Trays 2014 2015. For additional product information, visit us online at www.bd.com

SECTION. BD Medical Anesthesia Products - Trays 2014 2015. For additional product information, visit us online at www.bd.com SECTION A2 BD Medical Anesthesia Products - Trays 2014 2015 For additional product information, visit us online at www.bd.com BD Combined Spinal and Epidural Trays 405815 1/1/2014 17 G x 3 1/2 in. BD Durasafe

More information

OFFICIAL AIR AMBULANCE, GROUND AMBULANCE, AND FIREFIGHTING AGENCY INVENTORY

OFFICIAL AIR AMBULANCE, GROUND AMBULANCE, AND FIREFIGHTING AGENCY INVENTORY OFFICIAL AIR AMBULANCE, GROUND AMBULANCE, AND FIREFIGHTING AGENCY INVENTORY Pursuant to Health District EMS Regulations Sections 900.100 and 1000.100 any Air Ambulance or Ground Ambulance that is permitted

More information

Located On IV Pole Front of cart- Arrest Board

Located On IV Pole Front of cart- Arrest Board ADULT CRASH CART Adult Crash Cart First Supply To Expire Located On IV Pole Front of cart- Arrest Board In a Sleeve (back of cart) Top of cart Clipboard Zoll- checklist Exam gloves- 1 box under defib ACLS

More information

CITY OF COLORADO SPRINGS TAX GUIDE MEDICAL EXEMPTIONS

CITY OF COLORADO SPRINGS TAX GUIDE MEDICAL EXEMPTIONS CITY OF COLORADO SPRINGS TAX GUIDE MEDICAL EXEMPTIONS The City of Colorado Springs Sales and Use Tax Ordinance contains a medical exemption and definitions that, when combined, provide a variety of exemptions

More information

The specialists in single-use. Refractive

The specialists in single-use. Refractive The specialists in single-use. Refractive Flap Separators/Elevators 77 LASIK Flap Elevator, Curved, 8mm 0.mm 0.5mm Tip, Curved 8mm Tapered Shaft at 90. 8mm 78 435 LASIK Flap Elevator, Straight, 8mm LASIK

More information

Red rubber all-purpose urethral. Catheters. Bard Clean-Cath Intermittent catheter: 802408-22 8-22 Fr. 100/case

Red rubber all-purpose urethral. Catheters. Bard Clean-Cath Intermittent catheter: 802408-22 8-22 Fr. 100/case BARDIA Urethral Catheters Red rubber all-purpose urethral catheters: Radiopaque red rubber catheter with a round, hollow tip Can be used as a Robinson or a Nelaton catheter Two opposing drainage eyes 16

More information

Aerospace Medical Association

Aerospace Medical Association Paulo M. Alves, MD Anthony D. Evans, MBChB Frank S. Pettyjohn, MD Claude Thibeault, MD Aerospace Medical Association Medical Guidelines for Airline Travel In-flight Medical Care Reviewed and accepted by

More information

Ground Vehicle Supply Requirements for EMR Quick Response Units.

Ground Vehicle Supply Requirements for EMR Quick Response Units. Ground Vehicle Supply Requirements for EMR Quick Response Units. Ring cutters 2 Blood pressure cuffs, one adult, one pediatric 2 Stethoscopes, one adult and one pediatric or combination 2 Heavy duty shears

More information

Coloplast Product Guide Ostomy, Continence, Wound & Skin Care. Effective March 2010

Coloplast Product Guide Ostomy, Continence, Wound & Skin Care. Effective March 2010 Coloplast Guide Ostomy, Continence, Wound & Skin Care Effective March 2010 SpeediCath TM Intermittent Catheters The only ready-to-use hydrophilic catheter. Clinical research indicated that twice as many

More information

... more than you expect. Shipping supplies

... more than you expect. Shipping supplies ... more than you expect Shipping supplies Shipping boxes 000040 006 186x184x22 mm 000042 006 333x333x32 mm 9999007138 153x110x50 mm 9999007137 220x150x50 mm 000030 006 280x185x125 mm 000031 006 360x230x167

More information

Alliant Healthcare Products Overview

Alliant Healthcare Products Overview Alliant Healthcare Products Overview Alliant Healthcare Products is a Veteran Owned Small Business (VOSB) that designs, develops, manufactures and markets products for the U.S. healthcare market. Alliant

More information

RADIATION CONTROL TECHNIQUE #2 INSTRUCTIONS FOR PREPARATION OF RADIOACTIVE WASTE FOR DISPOSAL

RADIATION CONTROL TECHNIQUE #2 INSTRUCTIONS FOR PREPARATION OF RADIOACTIVE WASTE FOR DISPOSAL RADIATION CONTROL TECHNIQUE #2 INSTRUCTIONS FOR PREPARATION OF RADIOACTIVE WASTE FOR DISPOSAL I. PURPOSE: To establish a standard procedure for preparing Radioactive Waste and Radioactive Mixed Waste (RMW)

More information

CITY OF HOUSTON Department of Health and Human Services Emergency Medical Services Program

CITY OF HOUSTON Department of Health and Human Services Emergency Medical Services Program Ambulance Service Permit Application Process New Applicants: Please read and complete the following application carefully. Make sure all information is accurate to prevent a delay in verification and processing.

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

CITY OF HOUSTON Department of Health and Human Services Emergency Medical Services Program

CITY OF HOUSTON Department of Health and Human Services Emergency Medical Services Program Ambulance Service Permit Application Process New Applicants: Please read and complete the following application carefully. Make sure all information is accurate to prevent a delay in verification and processing.

More information

Emergency Medical Services Division. ALS Bike Medic Program Policies and Procedures August 15, 2014

Emergency Medical Services Division. ALS Bike Medic Program Policies and Procedures August 15, 2014 Emergency Medical Services Division ALS Bike Medic Program Policies and Procedures August 15, 2014 Edward Hill EMS Director Robert Barnes, M.D. Medical Director Table of Contents I. GENERAL PROVISIONS:...

More information

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g. How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g. Ebola) Step 1: Before entering patient room, assemble all equipment (1 st part)

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

Care for your child s Central Venous Catheter (CVC)

Care for your child s Central Venous Catheter (CVC) Care for your child s Central Venous Catheter (CVC) This booklet is intended for general informational purposes only. You should consult your doctor for medical advice. Please call the clinic or your home

More information

AMP Standard Terminals and Splices. RoHS. Ready

AMP Standard Terminals and Splices. RoHS. Ready AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control

More information

Application Data Important Safety Information

Application Data Important Safety Information Application Data Important Safety Information Read this page before using any of the information in this catalog. This catalog is designed to be used as a guide in selecting the proper hose for the applications

More information

Premier Pharmaceutical, Medical Equipment, Supply and Distribution FAQs

Premier Pharmaceutical, Medical Equipment, Supply and Distribution FAQs Premier Pharmaceutical, Medical Equipment, Supply and Distribution FAQs Who is the Lead Agency for the Pharmaceutical, Medical Equipment, and Supply Contract? Dane County Wisconsin RFP# 113102. Who is

More information

Search and Rescue Ready Pack

Search and Rescue Ready Pack New York Search and Rescue, Inc 91-33 221 Street # 1350 Queens Village, NY 11428-1350 www.newyorksearchandrescue.org Search and Rescue Ready Pack New York Search and Rescue recommends that its members

More information

INFORMATION ON CUSTOMS CLEARANCES FOR TRADERS FOR CLASS A MEDICAL DEVICES EXEMPTED FROM PRODUCT REGISTRATION

INFORMATION ON CUSTOMS CLEARANCES FOR TRADERS FOR CLASS A MEDICAL DEVICES EXEMPTED FROM PRODUCT REGISTRATION INFORMATION ON CUSTOMS CLEARANCES FOR TRADERS FOR CLASS A MEDICAL DEVICES EXEMPTED FROM PRODUCT REGISTRATION The HS Codes required for Customs clearances, such as through the TradeNet System, are managed

More information

TRANSPORT PROTOCOLS FOR PATIENTS ON AN INTRA-AORTIC BALLOON PUMP

TRANSPORT PROTOCOLS FOR PATIENTS ON AN INTRA-AORTIC BALLOON PUMP TRANSPORT PROTOCOLS FOR PATIENTS ON AN INTRA-AORTIC BALLOON PUMP Courtesy of Datascope Corp. Clinical Support Services Department TABLE OF CONTENTS Objectives of the Transport Team 2 Interfacility Transfer

More information

Expendable/Durable Items (Except Medical, Class V, Repair Parts, and Heraldic Items)

Expendable/Durable Items (Except Medical, Class V, Repair Parts, and Heraldic Items) Common Table of Allowance 50 970 Expendable/Durable Items (Except Medical, Class V, Repair Parts, and Heraldic Items) Headquarters Department of the Army Washington, DC 28 January 2005 UNCLASSIFIED SUMMARY

More information

Institutional members names have been submitted to each vendor for membership verification at the time of ordering.

Institutional members names have been submitted to each vendor for membership verification at the time of ordering. Website informational sheet PURCHASING CO-OP PRICE LIST 2016 for MPMA Members Description of Products & Discounts From Participating Companies These are some of the deepest discounts you will find because

More information

Environmental, Emergency, First Aid

Environmental, Emergency, First Aid Environmental, Emergency, First Aid Section Contents Horizontal Fire Extinguisher 152 Horizontal Fire Ext Bracket 152 Portable Fire Extinguisher Stand 152 Fire Extinguisher Sign 152 Fire Extinguisher 153

More information

Flexible Spill Containment Protecting You And The Environment

Flexible Spill Containment Protecting You And The Environment Flexible Protecting You And The Environment Unit Liner Company C o nta i n m ent Syste m s C o nta i n m ent Syste m s Foam Foam Clean and store for repeated use Includes Clean and patch store kit for

More information

CONTRA COSTA HEALTH SERVICES EMERGENCY MEDICAL SERVICES

CONTRA COSTA HEALTH SERVICES EMERGENCY MEDICAL SERVICES CONTRA COSTA HEALTH SERVICES EMERGENCY MEDICAL SERVICES AMBULANCE EQUIPMENT AND SUPPLY REQUIREMENTS. Vehicles a. Ambulance vehicles shall meet standards specified in Title 3, California Code of Regulations,

More information

DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT. Health Facilities and Emergency Medical Services Division

DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT. Health Facilities and Emergency Medical Services Division DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT Health Facilities and Emergency Medical Services Division 6 CCR 1015-3 Chapter 4 Licensure of Ground Ambulance Services Rules Pertaining To Emergency Medical

More information

EXAMPLE EXERCISE 3.1 Metric Basic Units and Prefixes

EXAMPLE EXERCISE 3.1 Metric Basic Units and Prefixes EXAMPLE EXERCISE 3.1 Metric Basic Units and Prefixes Give the symbol for each of the following metric units and state the quantity measured by each unit: (a) gigameter (b) kilogram (c) centiliter (d) microsecond

More information

The following book is required for purchase prior to the beginning of the semester:

The following book is required for purchase prior to the beginning of the semester: Dear Student: As a faculty member of the Johns Hopkins University School of Nursing, we are pleased to welcome you to the School. In preparation for a key nursing course, Principles and Applications in

More information

Transport and Mailing Systems

Transport and Mailing Systems Transport and Mailing Systems For transportation of diagnostic samples and blood products The complete product range for mailing and transport requirements Safe and compliant with transportation guidelines

More information

109-2-11 Standards for type V air ambulance vehicles and equipment. (a) The operator shall ensure that the patient compartment is configured in

109-2-11 Standards for type V air ambulance vehicles and equipment. (a) The operator shall ensure that the patient compartment is configured in 109-2-11 Standards for type V air ambulance vehicles and equipment. (a) The operator shall ensure that the patient compartment is configured in such a way that air medical personnel have adequate access

More information

CHS Medical Group Hazardous Waste Management In Service

CHS Medical Group Hazardous Waste Management In Service CHS Medical Group Hazardous Waste Management In Service Objective Educate staff how to properly manage Regulated Medical Waste (RMW), Chemotherapy Waste and EPA RCRA Hazardous Waste Ensure compliance with

More information

STOCK BOXES SIZE STYLE BUNDLE BALE NOTES

STOCK BOXES SIZE STYLE BUNDLE BALE NOTES STOCK BOXES SIZE STYLE BUNDLE BALE NOTES 4 x 4 x 4 RSC - 32 ECT C FLUTE 25 2000 4 x 4 x 48 5PF - 32 ECT B FLUTE 10 500 5 x 5 x 5 RSC - 32 ECT C FLUTE 25 2000 6 x 4 x 4 RSC - 32 ECT C FLUTE 25 2000 6 x

More information

DIRECT PRINTING NYLON JACKETS. The Basics

DIRECT PRINTING NYLON JACKETS. The Basics DIRECT PRINTING NYLON JACKETS The Basics . The Nylon Jacket Types of Nylon There are three basic weaves that are commonly used to manufacture nylon jackets or outerwear. These are Taffeta, Satin and Oxford.

More information

General Product Line Quick Quote U.S. Suggested List Price

General Product Line Quick Quote U.S. Suggested List Price Note: Not all items are presented in our order on line web site! Please use as a reference tool only. General Product Line Quick Quote U.S. Suggested List Price January 1, 2006 Table of Contents Tapers

More information

Health Technician skills checklist Health Services Department Lincoln Public Schools TEMPERATURE

Health Technician skills checklist Health Services Department Lincoln Public Schools TEMPERATURE Rev. 2/07 Health Technician skills checklist TEMPERATURE 1. Explain to student what you are going to do. 2. Wait for Welch-Allyn thermometer to beep, then apply probe cover. Make sure probe cover is secure.

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

Peel Adhesion of Pressure Sensitive Tape

Peel Adhesion of Pressure Sensitive Tape Harmonized International Standard Call Letters PSTC 101 Date of Issuance 10/00 Revised 10/03 Revised 05/07 Peel Adhesion of Pressure Sensitive Tape 1. SCOPE 1.1 These methods cover the measurement of the

More information

MaxCell Technical Manual Design Parameters

MaxCell Technical Manual Design Parameters MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50

More information

Health System Compliance Division Inspection Department Ambulance Inspection Checklist Class III Advanced Life Support (ALS)

Health System Compliance Division Inspection Department Ambulance Inspection Checklist Class III Advanced Life Support (ALS) Health Authority - Abu Dhabi ھيئة الصحة - أبو ظبي Health System Compliance Division Inspection Department Ambulance Inspection Checklist Class III Advanced Life Support (ALS) A- Ventilation and Airway

More information

CataLoG No. weight o.d. i.d. GLaSSwaRe

CataLoG No. weight o.d. i.d. GLaSSwaRe Lead weights with Vikem Vinyl Coating Protect and Stabilize Expensive Glassware Stabilizes vessels in water baths and on benchtops Added insurance against tipping and possible chemical spills Closed ring

More information

Double Coated Urethane Foam Tapes

Double Coated Urethane Foam Tapes 3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear

More information

Surgical scissors and forceps Product List

Surgical scissors and forceps Product List Surgical scissors and forceps Product List Sr. No Items Picture of Product Product specification 1 Grasping forceps-- 5 MM Grasping forceps are used to remove stones and retrieve foreign objects under

More information

Urology Extended Care

Urology Extended Care Urology Extended Care Urology Extended Care Covidien s mission is to provide quality urological devices delivering powerful benefits to physicians, caregivers, and patients. Covidien offers a comprehensive

More information

Frequently Asked Questions About the District of Columbia School Health Nursing Program

Frequently Asked Questions About the District of Columbia School Health Nursing Program GOVERNMENT OF THE DISTRICT OF COLUMBIA DEPARTMENT OF HEALTH Community Health Administration Frequently Asked Questions About the District of Columbia School Health Nursing Program The following questions

More information

A Guide to Managing Your Biological Waste at the University at Albany

A Guide to Managing Your Biological Waste at the University at Albany A Guide to Managing Your Biological Waste at the University at Albany Section 1 - What you need to know: Definition: "Regulated Medical Waste (RMW) shall mean any of the following waste which is generated

More information

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION ENTERAL NUTRITION Freka Enteral Feeding Tube Product Range Fresenius Kabi Limited, Cestrian Court, Eastgate Way, Runcorn, Cheshire WA7 1NT tel: 01928 533533 fax: 01928 533520 email: nutrition.service@fresenius-kabi.com

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

ALS Ambulance. Limited (L-ALS) Laryngoscope blades (Adult) straight 1 set 1 set N/A 1 set

ALS Ambulance. Limited (L-ALS) Laryngoscope blades (Adult) straight 1 set 1 set N/A 1 set NAPA COUNTY EMS AGENCY Minimum Equipment Requirements ADMINISTRATIVE POLICY 4004 The following list is applicable to all EMS providers within Napa County. This list is not all inclusive and serves as a

More information

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter IC 192 Rev C A measure of flexibility and strength. Table of Contents 1. Introduction 2. What is the Morpheus CT PICC? 3. What

More information

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS 4 AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10.0 Bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from polyacetal 2 bodies and above manufactured from polymade and glass fibre 3/4 to

More information

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL DO NOT REMOVE FILM FROM TUBING! THIS PRODUCT CONTAINS DRY NATURAL RUBBER! Products by NASCO About the Simulator The Life/form Pediatric

More information

RECONSTITUTING MEDICATIONS: HOW TO FLUFF UP MEDICATIONS

RECONSTITUTING MEDICATIONS: HOW TO FLUFF UP MEDICATIONS RECONSTITUTING MEDICATIONS: HOW TO FLUFF UP MEDICATIONS After the completion of this module you will be able to: Define medication reconstitution. Read a medication label. Reconstitute a medication. Calculate

More information

8 GENITOURINARY Order inquiries? 204.945.3000 Items may not be exactly as shown. Foley Catheters

8 GENITOURINARY Order inquiries? 204.945.3000 Items may not be exactly as shown. Foley Catheters GENITOURINARY GENITOURINARY 7 A Foley atheters Silastic Foley atheters Latex, 2-way, silicone/elastomer coated, short round tip, ribbed balloon, inflation valve, 2 opposing eyes, 10/box. ard 16 French,

More information

2.3. The management in each HCF shall be responsible for ensuring good waste management practices in their premises.

2.3. The management in each HCF shall be responsible for ensuring good waste management practices in their premises. 1. PURPOSE Health-care activities lead to production of medical waste that may lead to adverse health effects. Most of this waste is not more dangerous than regular household waste. However, some types

More information

Hospital Marketing Services. Inc. Reference and Buyers Guide

Hospital Marketing Services. Inc. Reference and Buyers Guide Hospital Marketing Services. Inc. Reference and Buyers Guide All HMS products are LATEX-FREE 1-800-786-5094 Fax: (203) 723-7248 www.hmsmedical.com Table of Contents Cover......................... Table

More information

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD HVAC/R GAS TEST GAUGE Hex or Bell Type mounting 5 to00 Psi pressure ranges Steel case and brass internals Use to pressure test all new gas installations for leaks and passing inspection codes. After installing

More information

TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.

TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options. Page 1 of 8 pages NOTE Contact Surgeon before giving any medication marked with an asterisk. In an emergency or during Loss of Signal, begin appropriate treatment; then call Surgeon as soon as possible.

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

SMA Aluminum Cylinders

SMA Aluminum Cylinders SMA Aluminum Cylinders PNEUMATIC TO 200 PSI HYDRAULIC 250 TO 400 PSI Non shock /8,, 2, 3 BORE SPACE SAVING AND CONVENTIONAL DESIGNS REPAIRABLE Very high quality Pancake type cylinders with all of the engineering

More information

REPAIR AND MAINTENANCE MANUAL

REPAIR AND MAINTENANCE MANUAL REPAIR AND MAINTENANCE MANUAL Professional Pest Control Application Equipment Prime Line Sprayers B&G Equipment Company 135 Region South Drive, Jackson, GA 30233 800.544.8811 Phone 678.688.5601 Fax 678.688.5633

More information

SUCTION, ASPIRATING TUBES

SUCTION, ASPIRATING TUBES 162300 536204 162345 162301 (shown twice size) Yankauer Suction Tubes YANKAUER SUCTION TUBES Standard adult size. 10 mm diameter. Tip has 2 mm central opening and four 2 mm side openings. 162300 12 1/2"

More information

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04 BROWN MINNEAPOLIS TANK PAGE 1 OF 7 PURPOSE: Create and Drawing Uniformity Create, explain, and establish a standard bill of materials to be placed on every drawing (except the overall tank elevation and

More information

UNIT (1) MEASUREMENTS IN CHEMISTRY

UNIT (1) MEASUREMENTS IN CHEMISTRY UNIT (1) MEASUREMENTS IN CHEMISTRY Measurements are part of our daily lives. We measure our weights, driving distances, and gallons of gasoline. As a health professional you might measure blood pressure,

More information

Gotta- Have- It Chart

Gotta- Have- It Chart Gotta- Have- It Chart One area of heartbreak at state and national HOSA competitive events is a failure to bring the needed supplies/materials to an event for orientation or competition. Every year competitors

More information

APPLICATION FORM FOR ADVANCED LIFE SUPPORT AMBULANCE. (For Certification by Committee for Registration of Ambulances in Delhi)

APPLICATION FORM FOR ADVANCED LIFE SUPPORT AMBULANCE. (For Certification by Committee for Registration of Ambulances in Delhi) APPLICATION FORM FOR ADVANCED LIFE SUPPORT AMBULANCE (For Certification by Committee for Registration of Ambulances in Delhi) 1. Applicant Details Name of the Applicant : (in Block letters) Name of the

More information

Anodes and Misc Equipment

Anodes and Misc Equipment Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,

More information

Hot water extractable acidity or alkalinity of paper (Reaffirmation of T 428 om-08) (No changes from Draft 1)

Hot water extractable acidity or alkalinity of paper (Reaffirmation of T 428 om-08) (No changes from Draft 1) NOTICE: This is a DRAFT of a TAPPI Standard in ballot. Although available for public viewing, it is still under TAPPI s copyright and may not be reproduced or distributed without permission of TAPPI. This

More information

MEASUREMENTS. U.S. CUSTOMARY SYSTEM OF MEASUREMENT LENGTH The standard U.S. Customary System units of length are inch, foot, yard, and mile.

MEASUREMENTS. U.S. CUSTOMARY SYSTEM OF MEASUREMENT LENGTH The standard U.S. Customary System units of length are inch, foot, yard, and mile. MEASUREMENTS A measurement includes a number and a unit. 3 feet 7 minutes 12 gallons Standard units of measurement have been established to simplify trade and commerce. TIME Equivalences between units

More information

NSN 4120-01-21 4-3692

NSN 4120-01-21 4-3692 *TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21

More information

CIVIL AVIATION REQUIREMENTS SECTION 2 AIRWORTHINESS SERIES X PART III DATED 12 TH JUNE, 1997 EFFECTIVE: 1 st MARCH 2011

CIVIL AVIATION REQUIREMENTS SECTION 2 AIRWORTHINESS SERIES X PART III DATED 12 TH JUNE, 1997 EFFECTIVE: 1 st MARCH 2011 GOVERNMENT OF INDIA OFFICE OF THE DIRECTOR GENERAL OF CIVIL AVIATION TECHNICAL CENTRE, OPP. SAFDARJUNG AIRPORT, NEW DELHI-110 003 CIVIL AVIATION REQUIREMENTS SECTION 2 AIRWORTHINESS SERIES X PART III DATED

More information

Here are trade show displays I'm sure will meet your goals. I can also find items priced within your expected budget.

Here are trade show displays I'm sure will meet your goals. I can also find items priced within your expected budget. Here are trade show displays I'm sure will meet your goals. I can also find items priced within your expected budget. Please review the items and let me know which ones you are interested in. You can also

More information

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET [METRIC] A-A-59135 28 OCTOBER 1997 SUPERSEDING PPP-C-1752D(3) 1 FEBRUARY 1993 COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET The General Services Administration has authorized the use of this commercial

More information

CHEMICAL INVENTORY WORKSHEET INSTRUCTIONS

CHEMICAL INVENTORY WORKSHEET INSTRUCTIONS CHEMICAL INVENTORY WORKSHEET INSTRUCTIONS This form may be used as an aid to gather chemical inventory information for reporting in the online EHSA database. Completion of this form does NOT take the place

More information

HOSE, TUBE, AND PIPE CLAMPS

HOSE, TUBE, AND PIPE CLAMPS hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions

More information

ANAESTHESIA AND GENERAL SURGERY PRODUCTS PHOENIX BRAND

ANAESTHESIA AND GENERAL SURGERY PRODUCTS PHOENIX BRAND ANAESTHESIA AND GENERAL SURGERY PRODUCTS PHOENIX BRAND PHOE Apr 11 ENDOBRONCHIAL TUBE, SINGLE USE Original Dr Frank Robertshaw design. D shaped lumina provides maximum cross sectional area, minimising

More information

Emergency Medical Services Advanced Level Competency Checklist

Emergency Medical Services Advanced Level Competency Checklist Emergency Services Advanced Level Competency Checklist EMS Service: Current License in State of Nebraska: # (Copy of license kept in file at station) Date of joining EMS Service: EMS Service Member Name:

More information

WHATMAN ÜRÜN LİSTESİ 1 / 53 KATALOG NO AMBALAJ ŞEKLİ. Labsciences

WHATMAN ÜRÜN LİSTESİ 1 / 53 KATALOG NO AMBALAJ ŞEKLİ. Labsciences Labsciences Sterivent 36, 0.2μm Inlet - 3/8 to 1/2 inch Stepped Hosebarb Outlet- 3/8 to 1/2 inch Stepped Hosebarb 1/pk 1/pk 2103 Sterivent 150, 0.2μm Inlet -3/8-1/2" Stepped Hosebarb Outlet- 3/8-1/2" Stepped

More information

Pharmacy Operations. Basic Facts in Pharmacy. Pharmacy Technician Training Systems Passassured, LLC

Pharmacy Operations. Basic Facts in Pharmacy. Pharmacy Technician Training Systems Passassured, LLC Pharmacy Operations Basic Facts in Pharmacy Pharmacy Technician Training Systems Passassured, LLC Pharmacy Operations, Basic Facts in Pharmacy PassAssured's Pharmacy Technician Training Program Pharmacy

More information

109-2-13 Standards for fixed-wing ambulance aircraft and equipment. (a) Each air

109-2-13 Standards for fixed-wing ambulance aircraft and equipment. (a) Each air 109-2-13 Standards for fixed-wing ambulance aircraft and equipment. (a) Each air ambulance operator shall comply with all Federal Aviation Regulations as contained in 14 C.F.R. Parts 91 and 135, as in

More information

Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution

Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution Volatile Acids DOC316.53.01144 Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution Scope and application: For digestor sludges. 1 Adapted from The Analyst, 87, 949 (1962).

More information

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents

More information

URINARY CATHETER INSERTION - STRAIGHT OR INDWELLING CATHETER

URINARY CATHETER INSERTION - STRAIGHT OR INDWELLING CATHETER URINARY CATHETER INSERTION - STRAIGHT OR INDWELLING CATHETER PURPOSE To obtain a sterile urine specimen. To facilitate emptying bladder. To relieve bladder distention. To irrigate bladder. To measure residual

More information

Occupational Health & Safety. First Aid in Saskatchewan Workplaces

Occupational Health & Safety. First Aid in Saskatchewan Workplaces Occupational Health & Safety First Aid in Saskatchewan Workplaces Occupational Health and Safety Division Table of Contents General Requirements...3 Exemptions...3 First Aid Training...3 First Aid Supplies...5

More information

COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE

COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE INCH-POUND A-A-59588 January 12, 2001 SUPERSEDING ZZ-R-765E/GEN May 10, 1989 COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE The General Service Administration has authorized the use of this commercial item

More information

Display & Exhibit Systems

Display & Exhibit Systems Display & Exhibit Systems 2016 Catalog NEW - Ripple Expandable Banner Stand System - page 4 EXPO Ready Retractable Banner Stand Our flagship banner stand - quality construction, great features and a fantastic

More information

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information