1 FIRE DETECTION SYSTEMS CATALOGUE 2011/2012
2 BENTEL SECURITY srl - A Tyco International Company Via Gabbiano 22, Zona Industriale S. Scolastica Corropoli (TE) Italy Tel Fax [email protected] [email protected] The images shown in this catalogue are merely indicative and Bentel Security s.r.l. reserves the right to modify at any time the characteristics of the products here represented. Some products are not available in all countries. Contact your local distributor for details.
3 Contents catalogue Addressable Control Panels - Page 4 FireClass Software Console Page 5 FireClass Accessories Page 6 FC400 Series Detectors Page 7 FC400 Series Visual/Acoustic Signalling Page 10 FC400 Series Detector Bases and Accessories - Page 11 FC400 Series Input & Output Modules Page 14 FC400 Series Module Accessories Page 17 FC400 Series Callpoints Page 18 FC400 Series Accessories Page 19 Beam Detectors Page 20 FireRay Optical Beam Smoke Detector Mounting Accessories Page21 Air Sampling Smoke Detection Page 22 Air Sampling Accessories Page 23 FireClass J400 Conventional Control Panels Page 24 FireClass J400 Panel Accessories - Page Series Conventional Detectors Page 27 Detector Bases and Accessories Page 29 ZT100 Series Conventional Detectors Page 31 Conventional Accessories Page 32 Power Supplies Page 33 Detector Test Equipment Page 35 3
4 FireClass 500 Addressable Control Panels The new FireClass 500 is a completely programmable series of addressable, modular control panels which meet the EN54 standard and which are suitable for medium to large fire alarm installations. Each loop supports up to 250 FireClass Digital Loop addresses detectors and devices can be mixed and matched in any combination. In addition, each control panel offers one conventional zone for maximum flexibility for device compatibility. Network up to one master and seven slave control panels via the onboard RS485 bus for maximum expandability needed in larger installations capable of controlling up to 4000 addressable devices. Each output can be associated up to 4 zones and/or to 3 inputs on the loop for selected intervention during alarm (location signalling, closing of fire barrier doors). NAC supervised programmable and silenceable outputs can be used for the activation of signalling devices. A non-programmable NAC, an auxiliary non-controlled alarm output and a non-controlled fault signal output (relay) are also available. Configuration programming and management of the FireClass 500 is made simple with the multilanguage alphanumeric keypad and the large backlit LCD. The control panel is protected by codes which allow command access only to authorized personnel. Possibility to connect up to eight FC500REP repeaters to the control panel through the RS485 bus, having the same display, advanced control function and visualization of the control panel. EN54 APPROVED 250 devices on each loop Automatic device-drift compensation 1 conventional input-line for the connection of up to 32 conventional devices Completely programmable software zones: FC520 = 128 FC510 = programmable open-collector outputs, 8 of which are monitored NAC supervised programmable and silenceable outputs FC520 = 3 FC510 = 1 1 non-programmable NAC 1 auxiliary non-controlled alarm output (relay) 1 non-controlled fault-signal output (relay) RS485 Interface for the connection of up to 8 FC500REP repeaters and up to 7 FireClass 500 Slave control panels 4000 event log Power supply 230 Vac 27.6 Vdc 5 A switching supply / battery-charger Product Code 2 Loop Control Panel 1 Loop Control Panel Repeater FC520 FC510 FC500REP 4
5 FireClass 500 Software Console FireClass 500 Software Console FC500 Software Console, the highly flexible and powerful programming tool that has been used successfully with FireClass systems since day one. Iit is constantly being extended and refined to meet every changing demand. Available for free download from the New graphical user interface View system diagnostics Fast and simple system configuration, also offline Transferable user database Device graphic displayed Configuration summary report Real time visualization of the loop current load Battery/wiring calculation Customizable cables database Visualization of all the devices assigned to a single zone Easy to create user interface with control buttons (Reset, silence, evacuate) FireClass 500 Graphic Maps FireClass 500 Graphic Maps is a new client/server emergency management system and fire detection graphical user interface. FireClass Graphic Maps is a Microsoft Windows based graphical interface with a high resolution colour display and provides annunciation, status display incorporating the latest FireClass Technology fire detection systems. Utilising a combination of symbols, floor plans, pictures, text, FireClass Graphic Maps displays the precise location. Real time visualization of control panel loop & zone status, etc. Multilevel map based on a tree structure Access device data from any pages of the map Addressable control panels 5
6 FireClass 500 Accessories IP Module FC500IP The FC500IP is an IP Module which is used to connect control units in the FireClass 500 range to a LAN. The same procedures may be performed using the FireClass Graphic Maps console application, either through the serial port or the network. With a public IP address, it is also possible to manage and monitor the control unit form anywhere in the world, as long as you have access to the Internet. Connect control units in the FireClass 500 control panels range to a LAN Teleservice for programming maintenance remotely via IP DHCP or manual configuration 128 bit AES encryption Installed inside the FC500 control panel cabinet Telecom Module FC500PSTN FC500PSTN is a Telecom Module which allows implementing the functions of Channel Telephone Dialler and Telemonitoring (functions E and J of standard EN54-1:1996), on the FireClass 500 control panels. Possibility of associating up to 3 voice messages for each event Built-in multiprotocol digital communicator: Contact ID and SIA 32 programmable telephone numbers Programming by PC via FireClass 500 Console Check for telephone line cutting Excluded line tone check Overvoltage protection Digital message recording/playback Built-in speaker for message playback Installed inside the FireClass 500 control panel cabinet Battery Cabinet FC500BX Extended Battery Cabinet house up to two 12 V, 38 Ah batteries providing extended battery backup time for the system. Dimensions (LxHxP): 452x350x209 mm Batterie housing: two 12 V, 38 Ah 6
7 FC400 Series Detectors The FC400 Series are addressable multi-sensor fire, smoke and heat detectors, which can be implemented as several detectors by the Fire Class 500 control panel. The FC400 Series are designed and approved to EN54. The FC400 Series detectors provide the latest fire detection technology in an attractive cost effective package. The FC400 Series detectors are supplied in an extremely robust and reliable fully sealed construction, which has undergone stringent environmental testing. Electrical contacts are moulded into the plastic to eliminate any movement. The detectors are constructed from hardwearing Fire Resistant FR110 plastic. The multi-sensor detectors are environmentally friendly. They use no radioactive parts and can be returned to the factory for recycling at the end of their life. All FC400 Series detectors are supplied with integral dust covers as part of the packaging. Dust covers are retained throughout installation and removed at commissioning time. Installation The FC400 Series detectors include a host of installation and service features which are provided to reduce installation and service costs and reduce repair times. Standard bases with multiple mounting options speed and simplify installation Unique park position for commissioning and service procedures. Detector Addressing programmed from the SERVICE Tool or FireClass 500 control panel Address flag fixed to the base to prevent mix ups during service Full range of remote installation and service tools Dirty Detector Read-out can be viewed on the SERVICE Tool or panel. Detection Modes All FC400 Series devices communicate to the FireClass 500 control panel using the fast reliable FireClass digital loop protocol. This allows each detector to operate in one or two of several detection modes, thus allowing it to be easily optimised to the risk. For example, to meet detection applications with multiple risks the FC400PH detector allows two detection modes to operate simultaneously. Multiple Fire Detection modes FC detection algorithms CO fire detection technology Up to 250 detectors per loop Optional bi-directional line isolation Remote detector verification & temperature read-out Highly featured SERVICE tool Programmable Alarm LED with 360 viewing angle Optional detector locking pin Variety of sounder and relay detector bases Address flag stays with the base Internationally approved Addressable control panels 7
8 FC400 Series Detectors Photo Optical Smoke Detector FC400P The FC400P is a sophisticated photo optical smoke detector which provides economical fire detection coverage without the use of multi-sensor. The FC400P provides detector condition monitoring and pre-alarm options but without the ability to drive functional bases. The 5B standard base or the FC450IB isolator base can be used with the FC400P. The FC400P cannot be used with the FC430SB sounder base. Dimensions (ØxH): 109 x 43 mm Operating Temperature: -20 to +70 C Storage Temperature: -40 to +80 C Standards: EN54-7 Multi-Sensor Smoke and Heat Detector FC400PH The FC400PH is a state-of-the-art smoke and heat detector which allows a full set of detection modes to be implemented in the FireClass 500 control panel to suit most smoke and heat detection applications. The FC400PH incorporates a unique mousehole design optical chamber with an unrivalled signal to noise ratio providing high resilience to dust and dirt which means reduced service costs. The unique design provides immunity to small insects and thrips without the need for a separate thrip filter. The FC400PH provides all the features of FireClass Digital Loop detectors. The 5B standard base or the FC450IB isolator base can be used with the FC400PH. The FC400PH can be used with the FC430SB sounder base.net Dimensions (ØxH): 109 x 43 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C Standards: EN54-5, EN54-7 8
9 Heat Detector FC400H The FC400H is a flexible cost-effective addressable heat detector with all the features of FireClass detectors. The FC400H returns the temperature to the FireClass 500 control panel which allows various detection modes to be implemented. The FC400H uses a high quality thermistor with very low thermal mass. This allows the detectors to provide fast accurate temperature detection as well as heat detection. The 5B standard base or the FC450IB isolator base can be used with the FC400H. The FC400H can be used with the FC430SB sounder base. Standards EN54-5 Dimensions (ØxH) 109 x 43 mm Operating Temperature: -20 to +70 C, +90 for low time Storage Temperature: -40 to +80 C Multi Sensor CO and Heat Detector FC400CH The FC400CH is designed to transmit, to a FireClass 500 control panel, digital signals which represent status of the carbon monoxide and heat elements of the detector. The 5B standard base or the FC450IB isolator base can be used with the FC400CH. The FC400CH can be used with the FC430SB sounder base. Dimensions (ØxH): 109 x 43 mm Operating Temperature: 0 to +55 C Standards: EN54-5, EN54-7 Addressable Loop Devices 9
10 FC400 Series Visual/Acoustic Signalling Sounder Addressable Beacon FC430SAB The FC430SAB is a FireClass Addressable Beacon that fits into the 5B Standard Base. Alternatively the FC430SAB may be fitted to the FC430SB, Sounder Base to enable the FireClass 500 Control Panel to communicate with and control this sounder bases and also provide a Flashing Beacon effectively turning the FC430SB into a combined addressable loop powered sounder and beacon. Dimensions (ØxH): 108x21.2 mm Operating Temperature: -10 to +55 C Storage Temperature: -25 to +70 C Sounder Addressable Module FC430SAM The FC430SAM Sounder Addressable Module is a FireClass addressable device which may be fitted to the FC430SB Sounder Bases to enable the FireClass 500 Control Panel to communicate with and control this sounder base, without the need for a detector, effectively turning the combination into an addressable loop powered sounder. Dimensions (ØxH): 108x21.2 mm Operating Temperature: -10 to +55 C Storage Temperature: -25 to +70 C Loop Power Sounder Base FC430SB The FC430SB Loop Power Sounder Base provides an additional sounder function on the FireClass 500 control panel. The FC430SB Loop Powered Sounder Base requires an associated FC400 series detectors, FC430SAB or FC430SAM module in order to operate, as it uses the address of the detector or the module that is fitted to it. The configuration FC430SB with detectors allows only to activate the sounder by his associated detector and could not be activated by zones. For this case you have to use the FC430SAM and FC430SAB. The FC430SB does not support the detector FC400P. Current Draw: 200 μa on standby (typical); 6.8 ma at full volume (90 dba); 1.2 ma at low volume (68 dba) Dimensions (ØxH): 110x37.5 mm (including mounting flange) Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C 10
11 FC400 Series Detector Bases & Accessories Universal Base 5 5B The 5B is the most common base designed to fix directly to the ceiling or various common backboxes. This base allows a detector to be plugged in directly. Variety of fixing options Remote LED connections Park position and address flag holder Integral breakout locking key Isolator Base 5 FC450IB With all the features of the 5B Universal Base the FC450IB Isolator Base allows any FC400 Series Detectors to be upgraded to incorporate bidirectional short circuit isolation. Implemented on every detector, the FC450IB can ensure that no detector is lost on a system in the event of an open or short circuit. Alternatively, the FC450IB can be implemented between detectors to provide short circuit isolation according to EN54. The FC450IB can be used as a stand alone line isolator fitted between call points and other ancillaries. All the features of the 5B Integral yellow LED to indicate when the built-in isolator has been Tripped Ceiling Tile Adapter Kit The Time Saver Ceiling Tile Adaptor is used with the 4B 4 detector base snap fit base and consists of three parts, a bezel and clamp that are fitted to the ceiling tile and a back-box that carries the detector and base assembly. Requires a 127mm diameter hole. The CTA adaptor plate allows to be used with other devices such as the FC430SB. Product Code Ceiling Tile Adaptor Kit (consists of 1 x / 1 x ) CTA-BB CTA Back Box CTA-BC CTA Bezel and Clamp CTA-AP CTA Adaptor Plate The CTA adaptor plate allows the Ceiling Tile Adaptor to be used with other devices such as the 802SB Addressable Loop Devices 11
12 FC400 Series Detector Bases & Accessories 4B 4 Detector Base 4B The new 4B 4 detector base is designed to snap-fit to the Ceiling Tile Adaptor. Adaptor or it can be screw fixed to a ceiling in the traditional manner. Variety of fixing options Remote LED connections Park position and address flag holder Integral breakout locking key Euro-Mounting Base FC450EMB The euro-mounting base provides a matching back box, which allows the 5 bases to be ceiling mounted with conduit entries for standard 18 and 21mm conduit. 2 x 18mm conduit entries 2 x 21mm conduit entries Fits all 5 Bases Deck Head Mounting DHM-5B Where the detectors are mounted in humid and environmentally challenging situations such as marine or offshore installations, the DHM-5B deck head mount provides a sealed waterproof mounting which protects the 5 bases electrical connections. Can be screwed, bolted or welded to the deckhead. Supplied with 1 terminal. 4 x 20mm gland entries Fits ALL 5 bases IP55 with supplied gasket Protective Detector Cage White powder coated steel protective cage for Series FC400 Detectors fitted with a sounder base. Dimensions: 120mm dia x 80mm deep Protective Detector Sounder Base Cage Robust steel protective cage for Series FC400 detector ranges using the 5 bases. Ideal for schools and sporthalls or whenever detectors need protection. Strong coated steel construction with 4 point fitting. 12
13 Duct Probe Unit DPK4 The DPK4 duct probe unit have been developed to detect smoke in ventilation ducts. They offer significant benefits in terms of performance and installation. The system comprises a single duct probe tube andhousing specially designed for optimum airflow through the smoke detector and suitable for use in incoming, outgoing and circulation air ducts of ventilation and conditioning systems. The duct probes can operate across a wide range of airflow speeds and are especially recommended for installations in ducts with air flow velocities between 1 m/s and 20 m/s. Unlike more traditional duct probe units that employ an inlet and exhaust tube with sampling holes, the DPK4 and DPK4I units uses a highly efficient single sampling tube that is slotted along its length. This allows the sampling tubes to be cut to the desired length whilst maintaining maximum efficiency. The transparent cover gives clear visibility of the detector, its LED indication and airflow indicator. A red plastic flag is fixed inside the housing providing a simple but effective confirmation that there is no leakage and that the air flow from the air duct is in fact passing through the housing. In order to reduce the time required to test the duct probe detector during routine maintenance, an aperture is provided that allows aerosol test gas to be directed at the detector without having to dismantle the unit. Built-in 5B Universal Base 5 Suitable for addressable and conventional systems Suitable for air velocities from 1 m/s to 20 m/s Can be used in combination with a wide range of detectors One-pipe air sampling system simplifies installation Range of aluminium probe tube available for air ducts up to 1500 mm Transparent lid allows detector to be seen Test hole on cover Sensitive flow indicator IP rating: IP 54 Dimensions (WxHxD): 180x235x183 mm Operating Temperature: -20 to +70 C Accessories Duct Probe Tube 600 mm Duct Probe Tube 1500 mm Duct Probe Bracket DPK600 DPKM1500 DPKBR Addressable Loop Devices 13
14 FC400 Series Input & Output Modules Beam Detector Module FC410BDM The FC410BDM is designed to interface FIRERAY 50/100 to the FireClass Digital Addressable Loop. The FC410BDM provides power from the loop, monitors the Fire and Fault outputs of the detector and also monitors inter-connections for open and short circuit faults. Overall Dimensions with plate (WxHxD): 148x87x14 mm Operating Temperature: -10 to +55 C Storage Temperature: -40 to +80 C Beam Termination Module FC410BTM Simplifies the wiring between beam detector and FC410BDM. It allows FC410BDM to be sited up to 40 m from the beam detector. Overall Dimensions with plate (WxHxD): 148x87x14 mm Operating Temperature: -10 to +55 C Storage Temperature: -40 to +80 C Contact Input Module FC410CIM The FC410CIM Addressable Contact Input Module is designed to monitor external equipments. The FC410CIM provides two inputs and can be configured to monitor normally open or normally closed inputs. Dimensions (WxHxD): 85x60x15 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C Mini Input Module FC410MIM The FC410MIM Mini Addressable Contact Input Module is designed to monitor external equipments. The FC410MIM provides one input and can be configured to monitor normally open or normally closed inputs. Dimensions (WxHxD): 48x57x13 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C 14
15 Detector Input Module FC410DIM The Addressable FC410DIM provides the ability to connect and interface up to two zones of 24V d.c. 2-wire conventional detectors to the FireClass 500 Control Panel. The conventional detection circuit is powered from an external 24V d.c. supply and is reset by the FireClass 500 control panel. The FC410DIM monitors the status and wiring to the detectors and the external 24V d.c. Dimensions (WxHxD): 85x60x15 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C Line Isolator Module FC410LI The FC410LI Line Isolator Module is designed to be used on the FireClass addressable loop control panel. It monitors the line condition and when detecting a short circuit will isolate the affected section whilst allowing the rest of the addressing circuit to function normally. The purpose of the FC410LI Line Isolator Module is to ensure that, on a looped addressable system, no short circuit fault can disable more detection devices than would be lost on a conventional non-addressable fire circuit. Dimensions (WxHxD): 85x60x15 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C Relay Interface Module FC410RIM The FC410RIM Relay Interface Module provides one volt-free relay changeover contact. Relay Contact Rating: 2 24 Vdc Dimensions (WxHxD): 85x60x15 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C Addressable Loop Devices 15
16 FC400 Series Input & Output Modules Single Input / Output Module FC410SIO The FC410SIO Single Input Output Module provides one volt-free relay changeover contact and one input to monitor external equipment. The input can be configured to monitor normally open or normally closed inputs. Relay Contact Rating: 2 24 Vdc Dimensions (WxHxD): 85x60x15 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C Multi Input / Output Module FC410MIO The FC410MIO Multi I/O Module has three inputs and four low power outputs. The inputs can monitor external equipments and can be configured to monitor normally open or normally closed inputs. All four low power outputs can drive a self-powered high voltage relay HVR800. By disabling the low voltage outputs three and four, the outputs one and two can be used as volt-free relay changeover contacts (2 24 Vdc). Dimensions (WxHxD): 110x72x18 mm Operating Temperature: -25 to +70 C Storage Temperature: -40 to +80 C High Voltage Relay HVR800 The HVR800 module is a non-addressable device which allows a low current mains rated relay to switch up to 10 A. Relay Contact Rating: Vac Dimensions (WxHxD): 42x26.5x74 mm Operating Temperature: -25 to +70 C Storage Temperature: -45 to +80 C 16
17 FC400 Series Module Accessories Ancillary Cover for FC Modules FC470CV Ancillary cover for use with 400 series modules. Will fit onto a backbox. White Plastic Surface Mount Back Box FC470DGB White plastic surface mount backbox for use with 400 Series addressable modules using FC470CV cover. Dry Lining Flush Mount Back Box FC470DLB Dry lining flush mount (for plasterboard etc) backbox for use with 400 Series addressable modules using FC470CV cover. Steel Flush Mount Back Box FC470FMB Steel flush mount backbox for use with 400 Series addressable modules using FC470CV cover. Metal Flush Mount Back Box FC470MDGB Metal surface mount backbox for use with 400 Series addressable modules using FC470CV cover. Addressable Loop Devices 17
18 FC400 Series Callpoints Addressable Callpoint (Indoor) FC420CP FC420CP Addressable Break Glass Callpoint is designed to monitor and signal the condition of a switch contact that is operated by activating the break glass element. The glass element may be replaced with the deformable plastic element which allows the FC420CP device to be reset, using the key supplied, after alarm activation. Dimensions (WxHxD): 89x93x59.5 mm (27.5 mm if flush mounted) Operating Temperature: -10 to +55 C Storage Temperature: -30 to +70 C Accessories Standard break glass callpoint housing FC420CPB Deformable Activation Element Cover Test key for all MCP and CP style callpoints Addressable Callpoint (Outdoor) FC421CP FC421CP Addressable Break Glass Callpoint is designed to monitor and signal the condition of a switch contact that is operated by activating the break glass element. The FC421CP is fitted into a standard weatherproof break glass callpoint housing. The glass element may be replaced with the deformable plastic element which allows the FC420CP device to be reset, using the key supplied, after alarm activation. Dimensions (WxHxD): 97.5x93x73 mm Operating Temperature: -25 to +70 C Storage Temperature: -30 to +70 C IP Rating:IP67 Accessories Deformable Activation Element Cover Test key for all MCP and CP style callpoints
19 FC400 Series Accessories Loop Service Tool FC490ST The FC490ST is a powerful and flexible tool for assistance in the installation, commissioning, diagnostics and service of FireClass fire detection systems. The tool allows all the addressable devices to be interrogated, tested and programmed. Suitable for desktop or single handed operation the FC490ST tool is battery operated using standard rechargeable batteries. Read/write the detector / ancillary address Display temperature / CO levels / smoke obscuration Programming of the LED Testing the detector remote LED and control outputs Perform the detector self verification test function Displaying detector dirtiness level Controlling ancillary outputs Reading ancillary status Power management options FC Loop Service Tool Case FC490STK A carry case which contains the following items: Car Lighter Adapter, Shoulder Strap. This provides space for the following items: FC490 Service Tool. Ancillary Programming Lead. Mains Charger. Remote LED Indicator 801RIL The 801RIL Remote Indicator is used where a detector LED is not visible i.e., when the detector is mounted in a roof void, lift shaft etc. Dimensions (WxHxD): 86x86x16 mm Operating Temperature: -20 to +70 C Storage Temperature: -45 to +80 C Current consumption Standby: 0 Alarm: 5.43 ma Remote LED Indicator 801HL The 801HL Remote Indicator is used where a detector LED is not visible i.e., when the detector is mounted in a roof void, lift shaft etc. Dimensions (WxHxD): 85x85x38 mm Operating Temperature: -25 to +70 C Storage Temperature: -45 to +80 C Current consumption Standby: 0 Alarm: 5 ma Addressable Loop Accessories 19
20 Beam Smoke Detectors Optical Beam Smoke Detectors Fireray50 / 100 The Fireray50 and Fireray100 are comprised of two base elements i.e. a combined infra-red transmitter and receiver in a common housing and a reflective prism. The electronics of the combined transmitter and receiver unit analyse the reflected beam from the prism for smoke and generates an alarm condition if a pre- determined level is reached. Range: Fireray100 = Fireray50 to 100 meters Fireray50 = 5 to 50 meters Area of coverage: Fireray100 up to 1500 sq; Fireray50 up to 750 sq Selectable sensitivity Self-check and automatic compensation Manual or Automatic Reset Low current consumption Dimensions (WxHxD): 130x210x120 mm Operating Temperature: -30 to +55 C Relative Humidity: 90% (non condensing) FR5000 Auto Aligning Optical Beam Smoke Detectors The FIRERAY 5000 motorised, auto aligning infrared optical beam smoke detector can now be installed with up to four detector heads per system, thus saving on installation time and costs. This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user, both now and in the future. Once the detector heads are connected, using the Easifit First Fix system, an integral LASER, which is aligned along the optical path of the beam, can be activated. This allows the reflective prism to be sighted quickly and with confidence. Once the LASER has been used to coarsely align the beam, the AutOptimise beam alignment system takes over and automatically steers the beam into the optimum position. Each detector head is independently configurable from 8m through to 100m and has its own individual fire threshold. The System Controller retains one set of Fire and Fault relays that is common to all detectors that are installed. The FR5000 MultiHead is supplied with one detector head and reflector for single beam operation from 8 to 50 meters. Up to 3 additional detector heads can be added to the controller to enable larger or more complex areas to be protected (Subject to local codes and standards). Motorised Auto-Aligning Up to 4 Detectors per System Controller Each Detector configurable from 8m to 100m Integral LASER Auto-Align Fast Automatic Beam Alignment Auto-Optimise Building Movement and Contamination Compensation Worldwide Approvals including EN54:12 and UL268 Controller Dimensions (WxHxD): 202 x 230 x 81 mm Detector Dimensions (WxHxD): 134 x 135 x 134 mm 20
21 Optical Beam Smoke Detector Mounting Accessories FR 5000 Detector Head Each detector head is independently configurable from 8m through to 100m and has its own individual fire threshold. The System Controller retains one set of Fire and Fault relays that is common to all detectors that are installed. Reflector Reflector 100 X 100mm 4 reflectors are required for distances from 50 to 100m. Universal Mounting Bracket The Universal Mounting bracket can be used with the Fireray 5000 detector head and the 1 or 4 way prism plates to enable the detector head or prism plates to be easily mounted and adjusted when fixing to angled walls or cladding. Flat Mounting Plate for 1 to 4 Prisms The Flat Mounting plate is a metal plate which will support a single prism or 4 prisms, the side mounting holes are compatible with Unistrut racking systems. Prism Mounting Plate for 4 Prisms The large prism plate will securely mount 4 prisms and is designed to be used in conjunction with the Universal Mounting Bracket (not included). Prism Mounting Plate for 1 Prism The small prism plate will securely mount a single prism and is designed to be used in conjunction with the Universal Mounting Bracket (not included). Addressable Loop Accessories 21
22 Air Sampling Smoke Detection ICAM Air Sampling Smoke Detection Systems IAS800 The ICAM IAS800 Air Sampling Smoke Detection System provides a flexible solution to meet the unique needs of numerous applications including industrial spaces such as cable tunnels, tamper proof and unobtrusive requirements for special accommodation, or can simply be used to replace spot (point) detectors in office environments. The IAS800 system actively draws air from the protected area through sampling holes in a pipe network. Sampled air is then filtered before being analyzed by upto two FC400 Series detectors. The IAS800 system is available in three configurations: IAS800 twin inlet pipe configuration which can be fitted with two detectors for monitoring one or two pipe runs. IAS801 single inlet pipe configuration which can be fitted with one detector. IAS802 twin inlet pipe configuration which can be fitted with two detectors for monitoring one or two separate pipe runs with independant fault outputs. The system utilises a high performance aspirator and software configurable flow monitoring circuitry. The air flow level is displayed on a ten element bar graph that can be adjusted for high and low flow thresholds, and flow failure is reported as a device fault. Powerful fan Upto two x 50m pipe runs Pipes can be individually monitored for air flow with LED bar graph FireClass Digital Loop and 24 VDC connections Fault monitored via the FireClas digital Loop IP65 enclosure Field serviceable air filters Uses standard 25mm Vesda pipe & fittings Technical Specification Supply Voltage 18 to 30Vdc Current Consumption 300mA Dimensions 259w x 184h x 166d mm Weight 2.77 Kg Operating Temp -10 to +55 C (with detectors) Humidity 10 to 90% RH NonCondensing Sampling Pipes 25 mm dia, 50m per inlet Product Code Aspirated Smoke Dual Detector common fault monitor ICAM IAS800 Aspirated Smoke Single Detector common fault monitor ICAM IAS801 Aspirated Smoke Dual Detector dual fault monitor ICAM IAS802 ICAM Course Filter (PK10) Special Equipments
23 Air Sampling Accessories Pipe 25mm Diameter VESDA aspirating pipe, printed along its length on opposite side at 450mm intervals. 3 m length pipe Order in multiples of 10. Socket 25mm Straight socket for 25mm pipe.order in multiples of 10. Socket Union 25mm Socket union to facilitate servicing of pipework. Order in multiples of 1. Bend 25mm 90 degree Long Radius bend Order in multiples of 5. Elbow 25mm 45 deg elbow Order in multiples of 5. End Cap 25mm End cap 25mm Order in multiples of 5. Equal Tee 25mm Equal Tee 25mm Order in multiples of 5. Pipe Clip 25mm Pipe Clip 25mmm Order in multiples of 10. Solvent Cement (0.25 Litre Tin) Solvent cement. Capillary Tube Conical Sample Point Assembly Capillary Tube Conical Sample Point Assembly. 25mm socket adaptor + 2m capillary tube (tube colour - red). Capillary Tube Flush Sample Point Assembly Capillary Tube Flush Sample Point Assembly. 25mm socket adaptor + 2m capillary tube (tube colour - red). Capillary Tube 10 mm Capillary Tube 10 mm 10mm o/d x 30m length (tube colour - red). Sampling Point Label (1 Reel) Sampling point label. Order in multiples of 100. Pipe Label (1 Reel) Pipe Label. Order in multiples of
24 FireClass J400 Conventional Control Panels 8 to 24 Zone Expandable Control panel J424-8 Designed and made according to EN54 and EN standards (with J400-EXT extinguishment module), the J424-8 is a microprocessor based control panel for medium and large applications. It has 8 zones main board and supports two J400-EXP8 expander modules, for a total of 24 zones and 512 devices (maximum 32 in each zone). Each detection zone is equipped with an alarm repeat output for selective alarm management in the event of fire. The control panel has supervised and silenceable alarm outputs for the control of the selfpowered sirens, piezoelectric sirens, fire bells, flashers, telephone diallers, etc. This easy-to-use control panel is protected by a lockable frontplate which allows operational access to authorized personnel only. The J424 control panel is also available with a backlit display, which shows all the information regarding the control panel status. The optional Console Software in Windows environment, allows full systems management of events memory, files, reset and all the programmable functions provided by the control panel. Main EN54 and EN approved (with J400-EXT extinguishment module) 8 controlled, balanced, bypassable input zones expandable to 24 by means of two 8 zone expanders Up to 32 devices can be connected to each zone (but no more than 512 in total): conventional fire detectors, alarm buttons, gas detectors Gas zone compatible with 4 20 ma gas detectors Manual call point recognition Programmable thresholds Missing detectors Day/Night mode Alarm verification time Programmable restoral and reset times One alarm-repeat output (open collector) for each input zone 2 supervised, silenceable, bypassable 24 V alarm output for the activation of piezoelectric sirens, fire bells and flashers Silenceable, bypassable alarm output, for the activation of 24 V self-powered sirens Silenceable fault-warning output for the activation of signalling and auxiliary devices Supervised fire output for telephone dialler activation Programmable open-collector output Alarm/fault memory up to next reset Command for silencing signalling devices (sirens) Command security using key and code Programmable from PC or keypad 50 events log viewed via PC Optional backlit display RS485 bus for connecting up to 4 repeater panels Technical Power supply: 230 Vac ±10% 27.6 Vdc 2.5 A switching supply/battery-charger Compartment for two 12 Vdc 17 Ah batteries Dimensions (wxhxd): 422x502x116 mm Weight (without batteries): max. 8.5 Kg 24 Conventional Control Panels
25 FireClass J400 Conventional Control Panels 2, 4, 8 Zone Control Panels J408 Designed and made according to EN54 and EN standards (with J400-EXT extinguishment module), the J408 is a microprocessor based control panel for small to medium applications. It has up to 8 zones, each supports up to 32 devices, for a maximum of 256 devices. Each detection zone has an alarm-repeat output for selective management in the event of fire. The control panel has supervised, silenceable alarm-outputs for self-powered sirens, piezoelectric sirens, fire bells, flashers, telephone diallers, etc. Main EN54 and EN approved (with J400-EXT extinguishment module) 8 (J408-8), 4 (J408-4) or 2 (J408-2) controlled, balanced, bypassable input zones Up to 32 devices can be connected to each zone: conventional fire detectors, alarm buttons, gas detectors Gas zone compatible with 4 20 ma gas detectors Manual call point recognition Programmable thresholds Missing detectors Day/Night mode Alarm verification time Programmable restoral and reset times One alarm-repeat output (open collector) for each input zone 2 supervised, silenceable, bypassable 24 V alarm output for the activation of piezoelectric sirens, fire bells and flashers Silenceable, bypassable alarm output, for the activation of 24 V self-powered sirens Silenceable fault-warning output for the activation of signalling and auxiliary devices Supervised fire output for telephone dialler activation Programmable open-collector output Alarm/fault memory up to next reset Command for silencing sirens Keypad commands require key or code Programmable from PC or keypad 50 events log viewed via PC RS485 bus for connecting up to 4 repeater panels Technical Power supply: 230 Vac ±10% 27.6 Vdc 1.5 A switching supply/battery-charger Compartment for two 12 V 7 Ah batteries Dimensions (wxhxd): 354x280x100 mm Weight (without batteries): max. 4 Kg Product Code Two Zone Control Panel J408-2 Four Zone Control Panel J408-4 Eight Zone Control Panel J
26 FireClass J400 Panel Accessories Repeater Panel J400-REP Repeater panel. Technical 4 wire connection to the panel (power supply included) The repeater panel may be installed up to 1,000 m from the control panel Displays all audible and visual signalling Control panel management Dimensions (wxhxd): 280x320x40 mm Weight: Kg LCD Display J400-LCD Backlit LCD display module, two lines with 16 characters for line. Main text regarding the system s status and it is equipped with 6 scroll keys. Extinguishment Module J400-EXT Extinguishment module with microprocessor control. Technical Output for electro-valves controlled by logic (AND/OR) between the status of the control panel zones Programmable extinguishment delay Output signals: extinguishment delay, extinguishment and released Input for the forced activation of the extinguishment devices; input for the pressure switch Fault signalling on pressure-switch supply line Fault signalling on input lines Bypass of extinguishment devices in the event of false alarm Inputs for manual activation, extinguishment inhibition and pressure supervision Expander Module J400EXP8 8 zones expander module for J424 panel. BRIDGE - Serial Interface Enables PC communication with J400 series fire control panels via RS485 bus. It receives data from zones and pheriperals and transmits commands to the system. PCJ Conventional Control Panels
27 600 Series Conventional Detectors The new 600 Series conventional detectors is the result of the evolution of conventional detectors design but with extra unique style features enabling improved operation, installation and easy servicing. Included within the 600 Series range is the new conventional enhanced carbon monoxide detector (601CH). The incorporation of a reliable electrochemical CO detection cell and high specification low thermal mass thermistor for accurate temperature detection has enabled the introduction of an enhanced CO detector suitable for fast, reliable fire detection on both slow and fast developing fires. The traditional detectors or two-status detectors in the 600 Series have two output statuses: standby or alarm. When used in conjunction with suitable monitoring and signalling equipment, they create an automatic detection system. Application As each type of detector responds to a particular fire characteristic, the relative speed of response of the detector is therefore dependent upon the type of fire being detected. The range of FC600 Series conventional detectors have been designed to provide the earliest possible warning of a fire condition, with a minimum possibility of false/unwanted alarms. EN54 Approved from LPCB Low operational voltage: 10.5 Vdc to 33 Vdc Aesthetically discreet Superior performance and reliability Designed for rapid installation Integrated alarm LED Remote LED connection Wiring polarity independent Compatible with standard mounting base and with relay base 27
28 600 Series Conventional Detectors Photo Optical Smoke Detector 601P 601P detector is capable of detecting the visible smoke produced by materials which smoulder or burn slowly, i.e. soft furnishings, plastic foam etc;. or smoke produced by overheated but unburnt PVC. These detectors are particularly suitable for general applications and areas where cable overheating may occur e.g. electrical services areas. Multi-Sensor Smoke and Heat Detector 601PH 601PH detector react to the whole range of fire products from slow smouldering fires, producing visible particles to open flaming fires producing large numbers of very hot smaller sized aerosols. It combines optical and heat detector technology to detect clear burning fire products which hitherto could only be easily detected by ion-chamber detectors. For normal ambient conditions, the high performance optical detector behaves as a normal optical detector. Only when a rapid rise in temperature is detected does the sensitivity of the detector increase and the presence of smoke will confirm a fire condition. The HPO will not operate on a rate of rise of temperature alone. Heat Detector 601H-R / 601H-F 601H-R (rate of rise) and 601H-F (fixed temperature) detectors detect abnormally high rates of rise of temperature and abnormally high (static) temperatures respectively. Multi Sensor CO and Heat Detector 601CH 601CH detector is a unique general purpose fire detector which provides very early warning of slow smouldering fires. Ideal for sleeping risks the CO fire detector is also well suited to many applications where heat detection is insufficient but smoke detection causes false alarms. As CO travels more freely than smoke the position of CO fire detectors is more flexible. This feature is particularly useful in large complex structures such as atria and warehouses, where position of smoke detectors is difficult. 28 Conventional Detectors
29 Detector Bases & Accessories 5 Universal Base 5B The 5B is the most common base designed to fix directly to the ceiling or various common backboxes. This base allows a detector to be plugged in directly. Variety of fixing options Remote LED connections Park position and address flag holder Integral breakout locking key Ceiling Tile Adapter Kit The Time Saver Ceiling Tile Adaptor is used with the 4B 4 detector base snap fit base and consists of three parts, a bezel and clamp that are fitted to the ceiling tile and a back-box that carries the detector and base assembly. Product Code Ceiling Tile Adaptor Kit (consists of 1 x / 1 x ) CTA-BB CTA Back Box CTA-BC CTA Bezel and Clamp CTA-AP CTA Adaptor Plate The CTA adaptor plate allows the Ceiling Tile Adaptor to be used with other devices such as the 802SB 29
30 4B 4 Detector Base 4B The new 4B 4 Detector Base is designed to snap-fit to the Ceiling Tile Adaptor or it can be screw fixed to a ceiling in the traditional manner. Variety of fixing options Remote LED connections Park position and address flag holder Integral breakout locking key Euro Mounting FC450EMB The Euro-Mounting base provides a matching back box, which allows the 5 bases to be ceiling mounted with conduit entries for standard 18 and 21mm conduit. 2 x 18mm conduit entries 2 x 21mm conduit entries Fits all 5 Bases Deck Head Mounting DHM-5B Where the detectors are mounted in humid and environmentally challenging situations such as marine or offshore installations, the DHM-5B deck head mount provides a sealed waterproof mounting which protects the 5 bases electrical connections. Can be screwed, bolted or welded to the deckhead. Supplied with 1 terminal. 4 x 20mm gland entries Fits ALL 5 bases IP55 with supplied gasket Protective cage White powder coated steel protective cage for Series FC400 Detectors fitted with a sounder base. Dimensions: 120mm dia x 80mm deep Protective Detector Sounder Base Cage Robust steel protective cage for Series FC400 detector ranges using the 5 bases. Ideal for schools and sporthalls or whenever detectors need protection. Strong coated steel construction with 4 point fitting. 30 Conventional Detectors
31 ZT100 Series Conventional Detectors Photo Optical Smoke Detector ZT100PL2 Conventional photoelectric smoke detector without base. Durable sensor head, no need for replacement; 2-WIRE/24Vdc; Standby current: 90 µa; Alarm current: 50 ma (max). Heat Detector ZT100HL2 Conventional rate of rise with fixed temperature heat detectors without base. 2-wire/24Vdc; Standby current: 55 µa; Alarm current: 50 ma (max). High Profile Base ZT100BH4 High base for installations needing more clearance from the mounting surface. Low Profile Base ZT100BL4 Low profile base. 31
32 Conventional Accessories Conventional Callpoint MCP200CS The MCP200CS is a resettable manual call point for conventional fire control panels. Easy to use and install, it complies with the EN 54-11standard. The MCP200CS has a large activation surface that gives a visual indication after use. Standby status is restored with a simple action using the provided key, while the transparent plastic cover provides an effective barrier to prevent accidental activation. An alarm status alert is completed by the illumination of the red LED indicator. Other features include, easy installation using push-fit terminals and the option of selecting the alarm current in order to isolate call point vs detector alarm alerts where possible on the same zone (only where the control panel design support this feature). Sounder H200 The H200 is a sounder indicating device for fire indication systems compliant with standard EN It emits an acoustic signal selectable from the 32 options, and have a trimmer for adjusting the volume. Power Supply: Vdc Current Consumption at 24 Vdc: from 12.5 to 37.4 ma IP Rating: IP21 Operating temperature: C Dimensions (Øxh): 92x94mm Weight: 254g Sounder and Beacon HS200 The HS200 is a sounder-beacon indicating device for fire indication systems compliant with standard EN It emits an acoustic signal selectable from the 32 options, and have a trimmer for adjusting the volume. The luminous signalling is performed by means of high-efficiency red LEDs. Power Supply: Vdc Current Consumption 24 Vdc: from 12.5 to 37.4 ma Current Consumption 24 Vdc: 16 ma IP Rating: IP21 Operating temperature: C Dimensions (Øxh): 92x110 mm Weight: 278 g 32 Conventional Accessories
33 Power Supplies Power Supply Stations BXM24/25-U / BXM24/50-U The BXM24/25-U and 50-U are approved by IMQ to EN 54-4: A1:2002 and EN :2001. The steel housing contains a 2,5 amp or 5 amp switch mode power supply and monitoring board and has space to accommodate 2 x 12V 17Ah sealed lead acid batteries. The 10 front panel LED s comprehensively indicate the status of the unit. Robust metal housing Twin fused outputs Temperature compensated charging Deep discharge protection of batteries Fault relay output Size 383mm wide x 408mm high x 97mm deep Weight 4.3 Kg (excluding batteries) Operating temperature -5 C to +40 C Supply voltage 230VAC 50/60Hz Comprehensive LED status indication Product Code BXM24/25-U = 2.5 A BXM24/50-U = 5.5 A Power Supply Stations BXM24/25-B / BXM24/50-B The BXM24/25-B and 50-B are approved by IMQ to EN 54-4: A1:2002 and EN :2001. The steel housing contains a 2,5 amp or 5 amp switch mode power supply and monitoring board and has space to accommodate 2 x 12V 17Ah sealed lead acid batteries. The 10 front panel LED s comprehensively indicate the status of the unit. RS485 Bus Interface, Up to 8 BXM24, -B version, can be connected Robust metal housing Twin fused outputs Temperature compensated charging Deep discharge protection of batteries Fault relay output Size 383mm wide x 408mm high x 97mm deep Weight 4.3 Kg (excluding batteries) Operating temperature -5 C to +40 C Supply voltage 230VAC 50/60Hz Comprehensive LED status indication Product Code BXM24/25-B = 2.5 A BXM24/50-B = 5.5 A 33
34 Power Supply-Battery Charger BAQ The BAQ is a power supply unit and battery charger for use with appliances that require a regulated voltage of 27.6 V and a maximum current of 5,5 A. Its power output is protected against overload, shortcircuit and accidental inversion of the battery polarity. Input Voltage: 240 Vac, -15% /+10%, 50/60Hz Output Voltage: 27.6Vdc, -1% / +1% Max. battery size (charge): BAQ35T24 = 2 x 12V - 7Ah max. BAQ60T24 = 2 x 12V - 15Ah max. BAQ140T24 = 2 x 12V - 15Ah max. Operating Temperature: -5º - +40ºC Dimensions: 38H x 205W x 98D mm Weight: 0.7Kg Product Code BAQ35T24 = 1.5 A BAQ60T24 = 2.5 A BAQ140T24 = 5.5 A 34 Conventional Accessories
35 Detector Test Equipment Dispenser for Solo Smoke and CO Canister SOLO330 Lightweight and simple to use Universal design suits wide range of detectors Spring loaded solution for suspended ceilings For use with Solo Smoke and CO Canisters Designed for use with Solo Dispenser Smoke Detector Tester Non flammable Fast activation CO Detector Tester Designed for use with Solo Dispenser Genuine, non-flammable CO stimulus Cordless Heat Detector Test Kit SOLO461 Battery powered No cables, trailing leads or hanging wires Suits fixed temperature, rate of rise detectors Lightweight and simple to use Universal design suits wide range of detectors Includes: 1 x Solo Heat Detector Tester; 1 x Solo Battery Charger Telescopic Access Pole SOLO100 Solo Telescopic Pole extends from 1.26 to 4.5 metres Optimum strength to weight ratio Certified non-conductivity Extension Pole SOLO101 A 1.13 metre Solo Extension Pole which can be used on its own or fitted to the Solo. Adaptor Tube B SOLO704 Adaptor for Solo Accesss Poles to allow fitting FC400RT Detector Removal Tool. 800RT Detector Removal Tool 800RT Compatible with FC400 Series detectors Storage Bag A protective carry and storage bag for the Solo or Testifire product ranges. 35
36 For more information on the products featured here or on any other Bentel Security product please call: or contact your Authorized Distributor. Please visit us at PN 2011 Tyco International Ltd. and its Respective Companies. All Rights Reserved. The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco International Ltd. will aggressively enforce its intellectual property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by Tyco International Ltd. are the property of their respective owners, and are used with permission or allowed under applicable laws. Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative
MINERVA MX MX Virtual Multi-Sensor Detectors
DATASHEET MINERVA MX MX Virtual Multi-Sensor Detectors Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Optional bi-directional
Premier M Plus & Infinity 8
25 Years of Manufacturing Excellence Premier M Plus & Infinity 8 Conventional Fire Alarm Systems 007 Assessed to ISO 9001: 2008 Certificate number 330 Premier M Plus 8-24 Zone Conventional Fire Alarm Panel
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
Fire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
HART HSSD High Sensitivity Smoke Detection
HART HSSD High Sensitivity Smoke Detection The HART High Sensitivity Smoke Detection system (HSSD) is an Aspirating Smoke Detection system (ASD) designed to give very early indication of an incipient
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19
TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
Analogue addressable devices
Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet
DTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
welcome to our world fire alarm systems - series 600 www.staticsystems.co.uk
Static Systems Group PLC Heath Mill Road, Wombourne Staffordshire WV5 8AN. United Kingdom. Tel: +44 (0) 1902 895551 Fax: +44 (0) 1902 324969 www.staticsystems.co.uk welcome to our world In line with our
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
Global System Technology(UK) PLC The Intelligent Solution
Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
Fire Detection Product Range
Fire Detection Product Range World Leading Fire Detection Products from the NITTAN group Issue 1.0 Business Overview The Nittan Group has been at the forefront of the fire protection industry since 1954
Always on the Lookout Perfect Protection against Burglary
Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
The supplier and installer of the system should be approved by the local civil defence authority.
ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer
C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems
P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier
AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
CB200 1 8 Zone Conventional Control Panel
CB200 1 8 Zone Conventional Control Panel > features Built-in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User-friendly
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work
GE Security Small Building Life Safety Solutions Affordable FireShield Conventional Fire Alarm Control Panels imagination at work cost Location: Environment: Solution: Flower shop Finely decorated, gentle
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
FAAST. Fire Alarm Aspiration Sensing Technology
FAAST Fire Alarm Aspiration Sensing Technology The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m2 state-ofthe-art facility
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:
EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: [email protected]
Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems
Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system
FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience
Life Alarm Fire Alarm Controls
FIRE SUPERVISORY SUPV SILENCED SILENCE AC POWER RESET UL, ULC Listed FM Approved MEA Approved* Life Alarm Fire Alarm Controls Fire Alarm Controls 4005 Series Fire Alarm Control Panels Eight through Thirty-Six
E-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating
QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2
QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2 2.1 GENERAL...2 2.1.1 Scope 2 2.1.2 References 2 2.1.3 Contractor s Responsibility 2 2.1.4 System Description
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
Protection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
FIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS
SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment
ACTIVE 5 ENGINEERING MANUAL
ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features
D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors
D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
Emergency Voice Communication Systems EVCS Network 8 Data Sheet
Emergency Voice Communication Systems EVCS Network 8 Data Sheet The Emergency Voice Communications System (EVCS) Network 8 is for use as a Fire Telephone system, Disabled Refuge Call system or as a combined
Fire Alarm system Installation Guide
Fire Alarm system Installation Guide Fire Alarm System Categories Systems designed for Protection of Property only, fall into two classifications P1 or P2. but a manual system is also needed, then this
INTELLIGENT MONITORING FOR SAFER BUSINESS
INTELLIGENT MONITORING FOR SAFER BUSINESS PANASONIC FIRE ALARM SOLUTIONS TECHNOLOGY FOR A BETTER WORKING WORLD CHOOSE PANASONIC FIRE SOLUTIONS AND YOU RE CHOOSING WORLD-CLASS PROTECTION With more than
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
CB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products
Basic Security 101 Overview Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Components of an Alarm System Main Control
FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:
Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.
BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
Fire alarm system EBL512 G3
Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands
AlarmSense 2-wire detection and alarm system. Product Guide
AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
PLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders
DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders For the automatic addressable detector bus C-NET Cerberus PRO Sounder base DBS720 11 selectable tones, 2 programmable activation levels Sound intensity
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE
Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals
INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
I.S. 3218 :2013 Fire Detection & Alarm Systems
I.S. 3218 :2013 Fire Detection & Alarm Systems Overview of significant changes 26 th March 2014 FPS Ltd Today s Programme Commencement Transition Competence & Qualifications System Certification System
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply
FIRE DETECTION, ALARM AND MASS NOTIFICATION SYSTEMS Inspection, testing, and maintenance of fire detection, alarm and Mass Notification systems shall be performed in accordance with the manufacturer's
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the