Producer: AII appropriate regulations, satisfied by engine plant: KlMlM. KlM 1/2



Similar documents
ECOCIAT. Domestic hot water heat recovery unit

RPV - RP - RA air handling units

TECHNICAL SPECIFICATION TYPE ATESO ALFA

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

Topvex SX/C, Topvex TX/C. Air Handling Unit

Operations Manual Blast Chiller

INFO. Legally binding regulations on relating to energy efficiency and environmental protection. Eco-Design Directive and EC-Commission Regulation

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

Mechanical Rooftop Custom Capabilities

Testing and Certification Procedure

FLEXIT S4 R S6 R S7 R

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Company Presentation

lindab we simplify construction Air Handling Units Product Overview

Transformer oil cooler ALFA A02

Dehumidifier D 850E. - Instruction manual version 02

US Installation Manual Smappee Monitor

Drainage specialist swimming pool and wellness area

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Performance Rating of Room Fan- Coils

CE Marking and Technical Standardisation

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Medical Waste Autoclaves. Medical Waste Autoclaves

MELA quick 12+ Compact. Fast. Strong.

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Glossary of Heating, Ventilation and Air Conditioning Terms

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

HVAC units for tramways, trains and metros Proven performance, high reliability and low life cycle cost

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Initial Type Testing Report

Direct Fresh Air Free Cooling of Data Centres

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

RiMatrix S Make easy.

IEQ-15 Air Distribution System

Drives and motors. A guide to using variable-speed drives and motors in retail environments

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Decree of the Ministry of the Environment on fire safety of ventilation systems

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Espresso coffee grinder

Commercial Gas Furnace Upflow

Nordic Heat Pump Product Guide

NORSOK STANDARD H-001 Rev. 4, Nov Heating, ventilation and air-conditioning

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

University of St Andrews. Energy Efficient Data Centre Cooling

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

CIBSE Guide M: Maintenance engineering and management Statutory compliance legislation and guidance

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Dehumidification Frequently Asked Questions

Certification based on F-gas regulation the Czech Republic experience

(English language translation, the original version is in Czech language) DEWALT PTB-PRO. DeWalt Black-&-Decker Str Idstein Germany

C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning

Air-Conditioning Buying Guide

Draft UCL Heating, Cooling and Ventilation Policy

CRAC Precision climate control units for data centres

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

marine refrigeration and air conditioning

Small Business Energy Consumption Survey (SBECS) User s Guide

CoolTeg Plus Chilled Water (CW) version: AC-TCW

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

Hazardous chemical substances

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

INFO 6/

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Hospital Sterilizers. T-Max Line

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION


ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

INDUSTRIAL ENERGY EFFICIENCY. CEE Bedrijvengroep, Researchpark Haasrode, Industrieweg 3, 3001 Heverlee

Glossary of HVAC Terms

RRV934. Multi-controller. Synco living

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Supplying new machinery

PLUG and PLAY VRV Connection

AHRI Standard 325 (Formerly ARI Standard 325) 1998 Standard for Ground Water-Source Heat Pumps

FVA/A1 saturated-steam sterilizer

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Weiss Mobile Air Conditioning Systems

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

ROTARY SCREW COMPRESSOR. RMD kw

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

SolCalor B.V. is officiel Benelux Service Center of SRB-Energy. Marktstraat 23, 5701 RM, Helmond, The Netherlands. Tel: +31-(0) Website:

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

2013 / ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list

ECP 208. Cold Rooms Controllers USER S MANUAL

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Transcription:

-~ Ii -KL KLME ME CE By Directions of European parliament and Council 98/37/EC, changed by Direction of European parliament and Council 98/79/EC (Government Regulation no. 24/2003 Coll.) By Direction of Council 73/23/EEC changed by Direction of Council 93/68/EEC (Government Regulation no.17/2003 Coll.) By Direction of Council 89/336/EEC changed by Direction of Council 93/68/EEC (Government Regulation no.18/2003 Coll.) Producer: Type designation: JANKA Radotín a.s. Vrážská 143 15301 Praha 5 - Radotín IÈ : 63999927 Air handling units KLM 102 IKCM 1-04".- KlM 06 KlM Co- KlM fi KlMlM - KlM I KLM - KLM KLM KLM 80 - I -102 I 102 -I~ -102 -I -104 -I Tij""4 -IKLME - 06 -I -- 06 80 KLME KLME -,KLMi)" 102 TO3 IKLMD -'M m04 05 06 07 Units KLM have been designed for supply and treatment of air in ventilation, heating, and airconditioning systems. Air passing through the fans must not contain any mechanical particles, fibrous dust or any foreign substances. Air-conditioning unit are assembled from individua I chambers. Chamber can be in configuration: fan chamber, free chamber, damper chamber, mixing chamber, filter chamber, heating chamber, electrical heating chamber, water cooling chamber, direct evaporator cooling chamber, heat recovery chamber with plate exchanger or with rotary wheel, silencer dam per, water or steam humidifier chamber. If there is placed fan or another moving equipment in the chamber, doors can be open/close only using special tool. Unit casing are made from galvanized, painted or stainless metal sheet panels. AII appropriate regulations, satisfied by engine plant: Direction of European parliament and Council 98/37/EC, at last changed by Direction of European parliament and Council 98/79/EC Direction of Council 73/23/EEC at last changed by Direction of Council 93/68/EEC Direction of Council 89/336/EEC at last changed by Direction of Council 93/68/EEC 1/2

ce References on harmonized technical standards, national technical standards and technical specifications used at the standard's consideration: ÈSN EN ISO 12100-1:2004 - Safety of machinery - Basic concepts, general principles for design - Part 1: Basic terminology, methodology ÈSN EN ISO 12100-2:2004 - Safety of machinery - Basic concepts, general principles for design - Part 2: Technical princíples ÈSN EN 953: 1998 - Safety of machinery - Guards - General requirements for the design and construction of fixed and movable guards ÈSN ISO 5149:1998 - Mechanícal refrigerating systems used for cooling and heating -- Safety requirements ÈSN EN 60335-1 :2003 - Safety of electrical appliances for households and similar purpose ÈSN EN 60335-2-40:2004 - Special requirements for electrical heat pumps, air-conditioning units and dehumidifiers ÈSN EN 610000-6-3:2002: EMC - Part 6-3: Master standards - Emissions - Household environment, business and light industry ÈSN EN 55014-1 :2001 EMC - Requirements for household electrical appliances, electrical tools and simílar appliances - Part 1: Emissions ÈSN EN 61000-3-2:2001 - EMC - Part 3: Limits - section 2: Limits for emissions of harmonic electric current (appliances with inlet phase current ~ 16 A) ÈSN EN 61000-3-3: 1997 - EMC - Part 3: Limits - section 3: Reduction of voltage fluctuatíon and blinkíng in distribution of supply mains of low voltage for appliances with nominal current ~ 16 A ÈSN EN 55014-2: 1998 EMC - EMC - Requirements for household electrical appliances, electrical tools and similar appliances - Part 1: Resistance Certificate no. E-30-00594-05 - according to Directive 73/23/EEC (certain voltage limits) Certificate no. E-30-00595-05 - according to Directive 89/336/EEC (electromagnetic compatibility) Certificate no. E-30-00596-05 - according to Directive 98/37/EC (machinery) Final Report no. 30-5120/2 dated 2005-11-30 I. KA. JAN Radono a.s. ~ /~~ 15301 PRAH 5 - Radotfn, Vrážská 143 12 2/2

Specification of the types and versions: KLM 02, KLM 04, KLM 06, KLM 08, KLM 10, KLM 12, KLM 16, KLM 20, KLM 25, KLM 31, KLM 40, KLM 63, KLM 80; KLMD 02, KLMD 05; KLME 02, KLME 03, KLME 04, KLME 05, KLME 06, KLME 07; KLMH 02, KLMH 04, KLMH 06, KLMH 08, KLMH 10, KLMH 12, KLMH 16, KLMH 20, KLMH 25, KLMH 31, KLMH 40, KLMH 63, KLMH 80; 02, 04, 06, 08, 10, 12, 16, 20, 25, 31, 40, 50, 63, 80 RULES FOR HANDLING THE CERTIFICATE: For the purpose of placing the products on the markets, the present Certificate may only be used provided that the normative documents specified on Page 1 have not changed. If the harmonized or determined standards applicable to the certified products have changed or new standards have been issued, the usability of the Certificate must be reviewed. The Certificate may only be used as a certificate for products specified on Page 1 and 2. This holds true also for the use in advertising, promotional and commercial materials. Unauthorised or deceitful use of the Certificate may be sanctioned (Article 19 of Act 22/1997 Coll., concerning technical requirements for products and amendment to certain acts, as amended). It is forbidden to change, amend or overwrite the data contained in the Certificate. The Certificate may not be used for products changed without the consent of the Engineering Test Institute, public enterprise in such a way that conformity with the technical requirements specified on Page 1 is affected. 8-30-00593-05, page 2 (2)

St'tní IIsk',ns.snln, s.p.

Strojírenský zkušební ústav, s.p., Brno, Èeská republika Engineering Test Institute, Brno, Czech Republic ~II I podle smìrnice 89/336/EHS (elektromagnetická kompatibilita) according to Directive 89/336/EEC (e/ectromagnetic compatibi/ity) I Èíslo Number E-30-00S9S-0S I~, I~ Držitel certifikátu - výrobce Owner of certificate - manufacturer Výrobky Products Typové oznaèení Type designation Podklad pro vydání certifikátu Basis of certificate JANKA Radotín a.s. Vrážská 143, 15301 Praha 5 - Radotín Èeská republika - Czech Republic Klimatizaèní jednotky Air-hand/ing units KLM 02, KLM 04, KLM 06, KLM 08, KLM 10, KLM 12, KLM 16, KLM 20, KLM 25, KLM 31, KLM 40, KLM 63, KLM 80; KLMD 02, KLMD 05; KLME 02, KLME 03, KLME 04, KLME 05, KLME 06, KLME 07; KLMH 02, KLMH 04, KLMH 06, KLMH 08, KLMH 10, KLMH 12, KLMH 16, KLMH 20, KLMH 25, KLMH 31, KLMH 40, KLMH 63, KLMH 80; 02, 04, 06, 08, 10, 12, 16, 20, 25, 31, 40, 50, 63, 80 Závìreèný protokol è. 30-5120/2 ze dne 2005-11-30 Fina/ Report no. 30-5120/2 dated 2005-11-30 Strojírenský zkušební ústav, s.p. potvrzuje, že výše uvedené výrobky splòují základní požadavky smìrnice 89/336/EHS (naøízení vlády è. 18/2003 Sb.). (~II The Engineering Test /nstitute approves that the above-mentioned products are up to the essentia/ requirements of Directive 89/336/EEC (Government Regu/ation no. 18/2003 Co//.). ~II Brno 2005-11-30 ~?"'::: ~~~~~ lng. Jiø! Rozs!val zástupce øeditele Deputy Dírector ~II I Strojírenský zkušební ústav, s.p. Hudcova 56b, 621 00 Brno, CZ tel.:+420541120111 fax: +420 541 211 225 E-mail: szu@szutest.cz http://www.szutest.cz ~ - - ~,., ---,- --