Chicago Plumber Licensure Examination Information



Similar documents
Chicago Stationary Engineer Licensure Examination Information

Connecticut Technical High School System Connecticut State Department of Education PLUMBING APPRENTICESHIP INFORMATION PACKET

Assessment Blueprint PHCC Educational Foundation Plumbing Year 2

PLUMBING ROUGH IN INSPECTION

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

What to Expect From the Examination. How to Study the Plumbing Codes

Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved.

When Should Examination Preparation Begin?

PlumbingCode06_ch00_fm 5/29/06 8:08 AM Page i 2006 INTERNATIONAL PLUMBING CODES HANDBOOK

Plumbing Apprenticeship Program Curriculum

Chapter 7 Plumbing Connections

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Sanitary Sewer Service Guide Information you need to know about sanitary sewer service and how to prevent sewer backups

2. What building projects are exempted? (permit not required)

Oregon Administrative Rules, Chapter Compilation- Building Codes Division DIVISION 695

Why Do I Have Sewer Smells In My Home or Business?

Candidate Information Bulletin State of Maine

Licensing & Certification

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

Top 10+ Mistakes of DWV plumbing design

WHEN IS A PERMIT REQUIRED?

Los Angeles Trade Technical College Student Employment Center PLUMBING. Part Time

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Village of St. Louis Sewer Back-up Policy

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

MASTERS PLUMBING & GAS SCHOOL Mastering the Art of Our Trade. Course Catalog

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

PLUMBING II COURSE DESCRIPTION

Does Wall Township require an inspection by the building department on resale of a home?

To many people, a home s plumbing system is perceived as being extremely

Oregon Plumbing Rule and Law RV

Understanding and Designing Plumbing Systems

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

Module 7. Plumber: Sink Installation

CITY OF PINOLE SEWER LATERAL ADMINISTRATIVE GUIDELINES

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

How To Get A Building Permit In Florida

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

Amendments to the 2012 International Plumbing Code

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

CITY OF SURREY BY-LAW NO. 6569

Plumbing Code Statutes and Regulations February 2011 Labor Standards and Safety Division Mechanical Inspection

One of the fundamental design elements that every

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards

CHAPTER 11 STORM DRAINAGE

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

PERMITS REQUIRED & PERMIT EXEMPTIONS

WESLEY BRIAN HUTTON KNOXVILLE, TENNESSEE LICENSED MASTER PLUMBER. Dear: Human Resources

Crawford Inspection Services C.C.B. #

Septic System Owner s Manual

PLUMBING PERMIT REQUIREMENTS AND CHECKLIST

October 5, 2015 Dear Client,

SAN JACINTO RIVER AUTHORITY GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS, INTERCEPTORS AND SEPERATORS

SANITARY SEWER SPECIFICATIONS

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Federal Wage System Job Grading Standards For Plumbing, Table of Contents

PRIVATE ALARM CONTRACTOR LICENSURE EXAMINATION INFORMATION

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

PVC Pipe Restriction Law and Legislation 1) NYS PVC Pipe Restriction Law (Repealed)

UTILITIES DEPARTMENT

SECTION 5 - COMMERCIAL CONSTRUCTION MECHANICAL, ELECTRICAL, PLUMBING AND SOLAR OTHER TECHNICAL CODES

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

Frequently Asked Questions

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

Town House Center Highway North Huntingdon, PA 15642

CHAPTER 11 STORM DRAINAGE

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

BUILDING SEWER CONNECTION REQUIREMENTS

2006 IPC INTERNATIONAL PLUMBING CODE AMENDMENTS PLANNING & DEVELOPMENT SERVICES DEPARTMENT

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Jay R. Smith Mfg. Co.

STATE OF SOUTH CAROLINA RESIDENTIAL PROPERTY CONDITION DISCLOSURE STATEMENT

The Town of Lakeshore Basement Flooding Information to Residents

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

Flood Checklist ACTION TO BE TAKEN BEFORE THE FLOOD SEASON

City of Elk River BASEMENT Office Use Only

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

2006 Codes. Please verify the following before calling for inspection

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

PMA ONLINE TRAINING Venting for Plumbing Systems

Beacon Hill Sewer District Standard Specifications

Sanitary Sewer Smoke Testing

Element D Services Plumbing

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Transcription:

Chicago Plumber Licensure Examination Information This candidate guide should help you prepare for the Chicago plumber licensure examination. Part I contains general information about testing procedures. Part II outlines the content of the examination and recommends study materials. Part III includes sample questions to help you prepare for the test. Part I General Information PURPOSE OF THE EXAMINATIONS This examination is required for professional licensure of plumbers in the City of Chicago. You must pass this test to be licensed. TEST VALIDITY & TEST LENGTH The test is timed to be three hours in length. All test questions have been subjected to strict psychometric controls and reflect standards and practices validated by plumbers who are licensed in the City of Chicago. STUDY MATERIALS REFERENCES & CALCULATORS MISSING AN EXAMINATION SUCCESS/ LICENSURE FAILURE Study materials for this examination are described in Part II of this candidate guide. These sources may be purchased directly from the publishers, from Internet bookstores such as Amazon.com or Barnes and Noble (bn.com). References that may be required to answer questions on the test will be provided with the examination. No calculators or printed materials other than those provided at the test site may be used during the test. There are no "make-up" examinations. You may re-register for the next examination date. THERE ARE NO REFUNDS. Candidates who score 70 or higher will receive a PASS notice and an application for licensure. Candidates who score below 70 will receive a FAILURE notice and an application for re-examination. Candidates are encouraged to retake the examination; many candidates who initially fail such an exam pass on subsequent attempts. 2009, Continental Testing Services, Inc. Printed 1/2009

Page 2 Part II Test Content and Recommended Study Materials Plumbers must demonstrate that they are familiar with safe practices and procedures in their profession. Content areas and their relative importance in this test are outlined below. Relevant sections of the 2003 Chicago Plumbing Code are noted. Current editions of the Chicago Building Code also provide this information. I. Plumbing Theory, Practices & Job safety 20% of Examination Public health, Plumbing Math & Principles, Planning, Safety & OSHA Requirements, Tools & Equipment, Basic Electricity II. Code Requirements for Plumbers & Contractors 2% of Examination Chapter 4-332 III. Plumbing Systems 44% of Examination Chapter 18-29 Article I Administration Article II Definitions Article III General Regulations Article IV Fixtures, Faucets & Fixture Fittings Article V Water Heaters Article VI Water Supply & Distribution Article VII Sanitary Drainage Article VIII Indirect/Special Waste Article IX Vents Article X Traps, Separators and Interceptors Article XI Storm Drainage Article XII Swimming Pools IV. Rehabilitation Requirements 5% of Examination Chapter 13-200 420 Provisions for Buildings being Remodeled 460 Plumbing Requirements V. Drawings, Charts & Plans 8% of Examination Reading Blueprints, Locating Fixtures, Completing Building Plans to Code VI. Cutting & Assembling Plumbing System Components 12% of Examination Water Flow & Connection Requirements Materials, Sizing & Drainage Requirements Using Copper, Steel, Cast Iron, Plastic & Acid-Resistant Materials VII. Troubleshooting, Maintenance & Repairs 10% of Examination Repairing Fixtures & Appliances, Waste-Water Systems, Water Distribution Systems, Drainage & Vent systems

Page 3 Recommended Study Materials All questions in this examination are based on information provided in the following sources. Therefore, all candidates should become as familiar as possible with each of these references in preparation for this examination. Some information from these references that may be required to answer questions on the test will be provided with the examination. However, no calculators or printed materials other than those provided at the test site may be used during the test. Most publishers will accept telephone orders to be charged to a VISA, Mastercard or American Express account. These references also may be available from Internet bookstores such as Amazon.com or Barnes and Noble (bn.com). 1. 2006 Chicago Plumbing Code (Also available in current edition of Chicago Building Code; see content outline to identify relevant sections) Publisher Index Publishing Company Phone: (312) 644-7800 415 North State Street, Chicago, IL 60610 Website http://www.lawbulletin.com 2. Blankenbaker, E. Keith. Modern Plumbing, 6 th Edition (2005). Publisher Goodheart-Willcox Company, Inc. Phone: (708) 687-5000 18604 West Creek Drive, Tinley Park, IL 60477-6243 Website http://www.goodheartwillcox.com 3. Ripka, L.V., Plumbing Design and Installation, 3 rd Ed. (2006). Publisher: American Technical Publishers Phone: (708) 957-1100 1155 West 175th Street, Homewood, IL 60430 Website http://www.americantech.org 4. Smith, Lee, Guest, J. Russell, D Arcangelo, Bartholomew, & D Arcangelo, Benedict, Mathematics for Plumbers and Pipefitters, 7 th Ed., (2008) or 6 th Edition, (2004). Publisher: Delmar Publishing Company Phone: (800) 347-7707 Website: http://www.delmar.com 5. Guest, J. Russell, D Arcangelo, Bartholomew, & D Arcangelo, Benedict, Blueprint Reading and Drafting for Plumbers, 2 nd Ed, (2009) Available July 2008. Publisher: Delmar Publishing Company Phone: (800) 347-7707 Website: http://www.delmar.com 6. McConnell, Charles N., Audel Plumbers Pocket Manual, 10 th Edition ( 2004) Publisher: Macmillan Publishing Company Phone: (800) 755-7672 273 Polly Drummond Road, Newark, DE 19711

Page 4 Part III Sample Test All questions on these examinations are multiple choice with one correct answer and three incorrect choices. For this sample test only, correct answers and references are provided at the end of this section to help you prepare for is examination. 1. Which term refers to the point at which material removed from a trench will stay without sliding back into the trench? A. Excavation B. Trench shield C. Angle of repose D. Trench shoring 2. How many gallons of water are required to fill 2500 feet of a 6-inch water main? A. 306 B. 2447 C. 2255 D. 3670 3. Which of these is appropriate for use on fires involving flammable liquids such as gasoline, grease and oil? A. Class A fire extinguishers marked with a green triangle B. Class B fire extinguishers marked with a red square C. Class C fire extinguishers marked with a blue circle D. Class D fire extinguishers marked with a yellow star 4. What does the Chicago Plumbing Code specify prior to a service pipe inspection? A. The entire service pipe must be left accessible until after the inspection. B. The service pipe must be left exposed only within five feet of each end. C. The service pipe trench should be filled with stand and compacted with water. D. The service pipe must be supported by compacted sand prior to the inspection.

Page 5 5. What does the Chicago Plumbing Code specify for underground piping with solder joints? A. Silver brazing alloys B. 95/5 tin-antimony solder C. Any solder with less than 8% lead content D. Any solder with lead content equal to or less than 0.2% 6. Which of these does the Chicago Plumbing Code define as a minor repair? A. Replacing a broken house drain B. Removing obstructions from soil and sewer pipes C. Reinstallation of fixtures during a remodeling project D. Installation of new fixtures during a remodeling project 7. What does the Chicago Plumbing Code specify as the depth of a sump or receiving tank? A. A minimum of 30 inches B. A maximum of 30 inches C. A minimum of 36 inches D. A maximum of 42 inches 8. What does the Chicago Plumbing Code specify as the maximum horizontal length between a trap and its vent? A. 18 B. 24 C. 30 D. 60 9. What do Chicago Plumbing Code specifications require for the grease retention capacity of a grease interceptor or a grease trap? A. Capacity in pounds of grease retained must be twice the flow rate in gpm for the sink or receptor served. B. Capacity in pounds of grease retained must equal the flow rate in gpm from the sink or receptor served. C. At least 75% of the grease received must be retained. D. At least 98% of the grease received must be retained.

Page 6 10. What does the Chicago Plumbing Code specify for handicapped accessibility when doors are being replaced in a remodeled residential building that must meet the Rehabilitation Code? A. Any door that is replaced must be at least 32" wide. B. Any door that is replaced must be at least 30" wide. C. Doors to toilet rooms must be at least 32" wide. D. Doors to toilet rooms must be at least 30" wide. 11. Who determines what information is in rough-in sheets? A. The architect B. The building contractor C. The plumbing contractor D. The fixture manufacturer 12. Which of these is the architectural symbol for a soldered sanitary T? 13. What is the total pitch on a 75' long drain line that is installed at a grade of 3 / 4 " per 10'? A. 4 7 / 8 " B. 5 5 / 8 " C. 6 3 / 8 " D. 7 1 / 2 " 14. What is the pressure on test plug at the base of a 32' high stack when it is filled with water? A. 10.42 psi B. 13.89 psi C. 18.23 psi D. 62.50 psi

Page 7 15. Which of these accurately describes the drinking fountain in the above diagram? A. It is individually vented. B. It is crown vented. C. It is stack vented. D. It is not vented. 16. What should happen after a combination thermostat and EOC opens in an electric water heater? A. The thermostat should reset itself automatically. B. The heating elements must be recalibrated. C. The combined unit must be reset manually. D. The EOC must be replaced immediately. 17. Which of these is LEAST likely to cause a submersible pump to deliver little or no water while it operates? A. Worn pump parts B. A loose motor shaft C. Defective motor wiring or cable D. A pump intake screen blocked by mud or sand

Question 18 refers to the following diagram. Page 8 18. What is the end to end length of pipe W if H 1 measures 4'-7 1 / 2 ", H 2 is 3'-4", the vertical measure is 5'-11 1 / 2 ", and each offset is 10" for an assembly using 2" threaded pipe? A. 4'-7 1 / 2 " B. 4'-6 1 / 2 " C. 4'-8 3 / 4 " D. 4'-9 3 / 4 " Correct Answers and References Correct Question Answer References (See list on page 3 of this study guide) 1 C Blankenbaker page 37, Ripka (1994) page 19 2 D Blankenbaker pages 48-49, Smith pages 9, 168, 172 2500' = 30,000"; Vol = (30,000" x 3 2 x Π)/231 cu in/gal=3670 gallons 3 B Blankenbaker pages 34-35 4 A 2002 Chicago Building Code 18-29-601.2 & 601.3 5 D 2002 Chicago Building Code 18-29-605.14.3 6 B 2002 Chicago Building Code 18-29-202 7 A 2002 Chicago Building Code 18-29-1111.3 8 D 2002 Chicago Building Code 18-29-906.1 9 A 2002 Chicago Building Code 18-29-1003.3.6 & 1003.3.3 10 C 2002 Chicago Building Code 13-200-420 11 D Ripka (1994) pages 264-80, Guest pages 137-151 12 B Blankenbaker pages 108-109 13 B Smith pages 118-120;.75" x 75'/10' =.75" x 7.5 = 5.625" = 5 5 / 8 " 14 B Smith page 178; 32 x 0.434 psi = 13.89 psi 15 A Blankenbaker pages 123-127; Ripka (1994) pages 138-142 16 C McConnell page 18 17 C McConnell pages 147-150 18 D Smith pages 79-85, 218, 223, 234; W: c-c = 71 1 / 2 " 10" = 61 1 / 2 " e-e = 61 1 / 2 " [( 1 11 / 16 + 3 1 / 16 ) 2 ( 1 / 2 )]= 61 1 / 2 " 3 3 / 4 " = 57 3 / 4 " = 4' 9 3 / 4 "