PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY



Similar documents
Building Integrated Combined Solar Thermal and Electric Generation Demonstration Project at Concordia University

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

Solar Air Heating. Objectives. Review basics of Solar Air Heating (SAH) systems. Illustrate key considerations for SAH project analysis

Sustainable Schools Renewable Energy Technologies. Andrew Lyle RD Energy Solutions

Solar energy is available as long as the sun shines, but its intensity depends on weather conditions and geographic

Solar Energy Systems. Matt Aldeman Senior Energy Analyst Center for Renewable Energy Illinois State University

Solar systems provide a range of flexible heating

Solar and Wind Energy for Greenhouses. A.J. Both 1 and Tom Manning 2

MORE POWER. A BETTER INVESTMENT.

Achieving Net Zero. Bradley Berneche, President Alouette Homes. National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008

Enough Solar Energy falls on New York in ONE DAY to power the state for ONE YEAR

Solar Power at Vernier Software & Technology

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Integrated Solar Radiant Systems

New technical solutions for energy efficient buildings. State of the Art Report Photovoltaic/Thermal Systems (PV/T)

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

ANALYSIS 2: Photovoltaic Glass Replacement

SOLAR TECHNOLOGY CHRIS PRICE TECHNICAL SERVICES OFFICER BIMOSE TRIBAL COUNCIL

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Technology Fact Sheet for Mitigation

Effect of Ambient Conditions on Thermal Properties of Photovoltaic Cells: Crystalline and Amorphous Silicon

Harvesting Solar Energy

SAN DIEGO COMMUNITY COLLEGE DISTRICT CITY COLLEGE ASSOCIATE DEGREE COURSE OUTLINE

Sustainable water heating solutions through solar systems

SAP 2012 IN A NUTSHELL

ENERGY PRODUCING SYSTEMS

Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.

Solar power Availability of solar energy

Measurement Report Test of PV/T-module SolarWall PVT A Report of IEA SHC Task 35 PV/Thermal Solar Systems Report DC4-2 June, 2007

Directorate for the Built Environment Building Standards Division

Using the sun to generate electricity

Solar energy and power

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

ENERGY EFFICIENCY EXPERTS. MCW's. Environmental Record. Green Design REDUCING OUR CLIENTS' ENVIRONMENTAL FOOTPRINT

SOLAR WATER HEATING TOOL KIT For Single-family Residences

Solar Photovoltaic Frequently Asked Questions

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

This presentation is posted for public use. ACEEE does not endorse any product or service.

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

The days of cheap abundant electricity are over! This article forms part

Activity 1: 2 butter cartons, scissors, cling film, thermometer, water, a sunny spot and a shady spot.

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Electricity from PV systems how does it work?

Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Solar Energy Discovery Lab

RESEARCH HIGHLIGHT. Solar Energy Potential for the Northern Sustainable Houses

A Roof Integrated Solar Heating System Without Storage

Wind and Solar Renewable Energy Applications

Passive Solar Design and Concepts

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

Remodelling of the heating systems of a sports centre based on life cycle assessment. Part II: Solar hybrid system.

MECHANICAL PROJECT PROPOSAL

GUIDE TO NET ENERGY METERING.

HBOX SOLAR 3A SOLAR POWERED ELECTROLYSER CASE STUDY 03

Photo Kirklees IS SOLAR ENERGY FOR ME? A guide to going solar

Rainwater Harvesting

Solar Thermal TECHNOLOGY. Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center Wcroc.cfans.umn.edu

How to Earn the LEED Green Power Credit

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Energy audit in Finland

Energizing Florida s Cities with Solar. Florida Redevelopment Association Annual Conference

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

ODTÜ Makina Mühendisliği Öğretim Üysesi. ODTÜ Mezunları Derneği, Vişnelik Tesisi

Solar Power HourSM. Solar educa on for your community.

Making Your Home Ready For Solar Water Heating

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE

Creating Efficient HVAC Systems

Photovoltaic System Technology

Solar Energy Utilisation in Buildings

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Volther Hybrid PV-T Panels

Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014

Regulation by the Feed-in Tariff: Experiences from Germany

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

MICRO HYDRO FOR THE FARM AND HOME

By: Crystal Warren IMPLEMENTATION OF SOLAR PANELS ON COMMERCIAL PROPERTIES AND THE COST-BASED INCENTIVES

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

Adaptive strategies for office spaces in the UK climate

New technical solutions for energy efficient buildings

Solar Technology and the Future

RENEWABLE ENERGY. in Canadian Colleges and Institutes. Association of Canadian Community Colleges

Why is it renewable? Well, the sun will always be there for us, and we can use as much of the sun s energy as we want and it will never run out.

Lab 10. Solar and Wind Power

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Marketing Methodology of Solar PV Power Packs

Residential/Small Commercial Monitoring of Solar Thermal- Geothermal Integrated Systems

Energy Conservation Audits for Six Performing Arts Facilities A Toronto s Green Theatres Project

SA Power Networks Planning for Solar PV? Customer information guide to network connected solar PV inverter systems

Solar Power Frequently Asked Questions

Solar Cooling. Methods and Applications. Sargon Ishaya, PE, LEED AP

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

Transcription:

PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY John Hollick Conserval Engineering Inc. 200 Wildcat Road Toronto Ontario jhollick@solarwall.com ABSTRACT PV modules generate electricity, but the electrical output is only one component of the total energy produced by a photovoltaic array. A typical photovoltaic (PV) module has an ideal conversion efficiency in the range of 15. The remaining energy produced is heat, which is neither captured nor utilized. This heat increases the operating temperature of the PV modules, which actually decreases their overall performance. Recent scientific testing done in conjunction with the International Energy Agency Task 35 Project at Canada s National Solar Test Facility has shown that it is possible to capture almost two to three times more thermal energy than electricity from a PV array. Panels from various manufacturers were tested under NOCT conditions, and the results showed that when PV modules were mounted on top of SolarWall transpired collector panels, the total solar efficiency increased to over 50, compared to the typical 10 to 15 for PV modules alone. By removing the excess heat generated by the PV modules, the electrical output is increased. Modules can commonly operate at temperatures over 50 degrees C above ambient temperature, resulting in a performance reduction of more than 25. By dissipating the heat from the module and lowering the operating temperature, significant gains can be made in system performance and the heat can be utilized for practical heating purposes. As a result of these effects, the testing showed that the payback on a PV system that incorporates a thermal component could be reduced by between one third and one half. This paper will present the test results, and the practical and scientific implications of using a transpired solar collector with conventional PV to create a solar co-generation system. 1. INTRODUCTION The trend with photovoltaic (PV) installations is towards building integrated systems, and while this is advantageous in many regards, there are problems associated with conventional methods of integrating PV directly into a building. The main problem with building integrated photovoltaic (BIPV) systems is heat buildup under the PV modules. The heat produced can be as much as 50 C (90 F) over ambient temperature resulting in two concerns. The first is the possible structural damage from heat if panels are not vented or if heat is not recovered. The second is the lower efficiency of most PV modules with increasing temperature. Crystalline cells are affected by temperature and the performance drops as cell temperature rises. It has been shown that for each C increase in temperature, the power production drops by ~0.5. This means that a BIPV 100 W crystalline module at 65 C is only delivering 80 W of power compared with the 25 C name plate rating. A PV module can have a stagnation temperature of 50 C above ambient if the heat is not removed. If ambient temperature is 30 C, the actual module temperature can be 80 C, or even higher, on some tiled roofs. Another issue facing installers and customers is competition for roof space and deciding on which solar technology should have priority. Covering a roof with PV modules only uses 10 to 15 of available solar energy and eliminates the possibility for future solar thermal systems with much higher solar conversion efficiencies. A client may not be able to install solar panels to heat water, a pool or the building when the roof is already covered with a solar electric technology. Grid tied PV systems have a high initial cost and are generally sold only with generous incentive programs. A possible solution to the long payback situation is to see

whether the "waste" solar heat can be recovered and used to lower heating costs. 2. PV THERMAL PROGRAM The International Energy Agency (IEA) initiated Task 35 "PV/Thermal Solar Systems", a three year research program, on January 1, 2005, as part of the IEA Solar Heating and Cooling (SHC) Program. The objectives of this Task are to catalyze the development and market introduction of high quality and commercial competitive PV/Thermal Solar Systems, to increase general understanding of PV/T and contribute to internationally accepted standards on performance, testing, monitoring and commercial characteristics of PV/Thermal Solar Systems in the building sector. systems being installed, the most popular models from each manufacturer were chosen for the testing at NSTF. Arrangements were made with three manufacturers, BP Solar, Evergreen Solar and UniSolar to test their panels on the 10 square metre (108 ft2) test panel previously used for certification tests of the SolarWall system. The definition of PV/Thermal solar system is a combination of photovoltaic (PV) and solar thermal components which produce both electricity and heat from one integrated system from the same surface area exposed to the sun. PV and solar thermal panels which operate side by side and not together are excluded from this definition. The European members of the Task were focused on liquid collectors as the solar thermal component of the PV Thermal system. Canada decided to investigate air as the transfer medium to remove heat from PV arrays, represented by Conserval s SolarWall transpired solar collector. Rather than develop a new PV Thermal panel, Conserval took the approach of combining commercially available PV modules on top of the transpired collector and utilizing the unique air balancing features of the transpired collector to remove heat from the back of the PV array. In essence, the PV panel becomes a back pass solar air collector with the PV cells acting as the solar heat absorber with ambient air passing around and behind each PV module, removing heat and then the heated air enters the perforations in the transpired panel. This concept allows for heat removal from most PV modules currently available on the market and avoids the lengthy delays associated with developing a new PV panel and obtaining the associated electrical approvals. It is realized that the thermal performance may not be optimized but some heat should be recovered. The purpose of the Canadian test program was to quantify the amount of heat that could be readily recoverable from commercially available PV modules. 2.1 Testing Program The trend in PV installations has been to use larger PV modules. To obtain data that is representative of the Fig. 1 Schematic of PV modules mounted on perforated metal panels Special mounting clips were made to mount the BP and Evergreen PV modules approximately 10 mm above the transpired collector to allow air to flow behind the PV panels. Fig. 2 PV panels on SolarWall test panel Evergreen supplied six of their new 170 Watt panels. Two rows of three panels covered 90 of the 10 m2 test panel.

BP Solar supplied six of their 160 Watt panels which when placed onto the test panel covered approximately 76 of the test panel surface leaving 24 of the transpired panel exposed to the sun. m3/h.m2) of gross collector surface which represent low and medium air flows typical for heating ventilation air. Fig. 4 PV/T testing with six BP 160 Watt panels Fig. 3 PV Thermal testing with six Evergreen 170 Watt panels at NSTF UniSolar supplied eight of their peel and stick 68 Watt modules which fit nicely onto the test panel in a horizontal configuration and covered 90 of the test panel. The tests were conducted indoors at Canada s National Solar Test Facility (NSTF). One problem identified by the IEA Task 35 working group is which standard test condition should be used to test a PV Thermal system. PV panels are tested with a flash test at 1000 Watts/m2 and 25 C. NOCT tests use 800 Watts/m2, 1 m/s wind and an open back. Thermal panels are generally tested at 900 Watts/m2 and at 3 m/s wind. In addition, the transpired collector can accommodate a wide range of air flows through the panel. It was decided to perform two sets of tests at two flow rates for each panel, one set at NOCT conditions and the other at the solar thermal conditions. The air flow heat removal rates selected were 2 cfm/ft2 (36 m3/h.m2) and 6 cfm/ft2 (108 Fig. 5 PV/T testing with eight UniSolar 68 Watt modules

3. TEST RESULTS The tests were performed over a two week period in October 2006 and the results are summarized in the following tables. Table 1 lists the two primary test conditions. The heat was drawn off at two rates, 2 and 6 cfm/ft2 of collector surface and results are shown separately for each flow rate. Tables 2 & 3 indicate the difference in air temperature between ambient and the air leaving the transpired solar panel. Irradiance, wind speed and flow rates are shown to all have an effect on the thermal gain. TABLE 1: TEST CONDITIONS Designated # Test Type Irradiance [W/m 2 ] Wind Speed [m/s] PV 1 NOCT 810 1 2 Thermal 910 3 TABLE 2: AIR TEMPERATURE RISE @ 6 CFM/FT2 Collector Type [ C] [ C] BP PV/T 9 7 Evergreen PV/T 9 6 UniSolar PV/T 11 9 TABLE 3: AIR TEMPERATURE RISE @ 2 CFM/FT2 Collector Type [ C] [ C] BP PV/T 15 9 Evergreen PV/T 14 10 UniSolar PV/T 20 15 The Evergreen panels and UniSolar panels have similar coverage area of 90 but are significantly different in shape. The Evergreen and BP panels are similar type and shape with the main difference being the coverage area, BP panels only cover 76 of the surface of the transpired panel compared with 90 for the Evergreen ones. TABLE 4: THERMAL EFFICIENCY @ 6 CFM/FT2 Collector Type Eff. Ideal Eff. Ideal BP PV/T 44 63 28 62 Evergreen PV/T 40 57 27 60 UniSolar PV/T 50 71 39 87 Bare transpired panel 70 100 45 100 TABLE 5: THERMAL EFFICIENCY @ 2 CFM/FT2 Collector Type Eff. Ideal Eff. Ideal BP PV/T 24.1 54 13.4 45 Evergreen PV/T 23.2 52 14 47 UniSolar PV/T 31.4 70 21.5 72 Bare transpired panel 45 100 30 100 The thermal results are interesting in that they clearly show a reasonable heat gain and reasonable solar efficiencies. For comparison purposes, the thermal efficiencies of the bare transpired panel are shown, which have been taken from the previous certification test data on the same 10 m2 test panel. Transpired collectors are installed for heating or preheating the ventilation air required in buildings. Most applications are designed to preheat air with a temperature rise in the 5 C to 20 C range. The test data shows that the temperature gain from the PV modules is between 6 C to 20 C or well within the typical range for transpired collectors. It was expected that the bare transpired collector would perform better than with PV modules mounted above it (PV/T). What is surprising is that by resizing the transpired collector or adjusting the air flow rate, the same thermal design target with PV/T is possible as is currently produced in many transpired collector installations. The NOCT tests are conducted with an open back and PV suppliers typically list a PV panel temperature in the 47 C range. The PV/T tests, (with a closed back) as listed in Table 6, which is typical of a BIPV configuration, show temperatures similar to or lower than the NOCT data.

TABLE 6: ELECTRIAL AND THERMAL EFFICIENCIES Test Air Flow PV Power PV η rated PV η Actual T avg Thermal Power Thermal η T rise Total η Watts C Watts C EG 746 11.4 10.3 1878 23.2 14.41 32.4 EG 2 2 858 11.4 10.5 1276 14 9.74 23.4 BP 2 2 720 11.9 10.5 1220 13.4 9.36 21.3 BP 637 11.9 10.4 1954 24.1 15.12 31.9 US 477 6.1 6.6 2542 31.4 19.68 37.3 US 2 2 1962 21.5 15.06 N/A US 2 6 557 6.1 6.8 41 3573 39.3 9.46 45.4 US 1 6 487 6.1 6.7 48 4076 50.4 10.8 56.4 BP 1 6 627 11.9 10.3 46 3545 43.8 9.42 51.6 BP 2 6 726 11.9 10.5 37 2534 27.8 6.72 35.8 EG 1 6 753 11.4 10.3 47 3229 39.6 8.56 48.8 EG 2 6 866 11.4 10.6 4443 26.7 6.43 36.2 The efficiency data for the PV portion of PV/T in Table 6 is based on the dimensions of the PV modules. The thermal efficiency data is based on the transpired collector area of 10 m2. Since the PV modules do not cover 100 of the transpired collector, the column showing Total η (efficiency) is not a straight addition of the PV and thermal numbers but is based on the gross test panel area of 10 m2. 3.1 Practical and Scientific Implications The test data clearly indicates that all of the PV modules tested produce more thermal energy than electrical energy under all test conditions. These off the shelf panels have not been optimized for thermal gain. In fact, the BP and Evergreen modules, due to their more square shape compared with the UniSolar modules, can be considered the worst case for thermal efficiency. These poor thermal collectors still delivered from 150 to 400 more thermal energy than electricity. The UniSolar panels delivered from 400 to 800 more thermal energy than electricity. The long rectangular shape of the UniSolar panels appears to be better suited for heat collection. These tests were meant to quantify the thermal energy that is possible from conventional PV modules and provide data to allow designers to assess the merits of considering a PV/T system. Using readily available PV modules eliminates the lengthy delays and costs that would be required for approvals if new PV modules were developed to improve the thermal performance. It is realized that the thermal energy may not be as useful as electricity or be required year round, however, the heat can be used during the heating season to heat and ventilate buildings. During the summer months, the heat can be used to heat swimming pools in residential applications, preheat domestic hot water, dry clothes or crop drying, and for drying desiccants if desiccant cooling is utilized. When heat is not required, it can be vented. When space on the roof or wall is limited or when the available solar surface becomes a contest for which solar technology will win, PV Thermal offers the designers and customers a solution to solve the dilemma. The generous incentives available in many jurisdictions for PV systems could create long term concerns, especially when additional fossil fuel usage needs to be curtailed and clients have already covered the entire roof with PV, leaving no more space to displace further CO2 emissions by increasing the renewable energy usage for that building. The transpired collector costs approximately 25 of a PV system on a per unit area basis. On an economic basis, it makes sense to evaluate the benefits of recovering heat from PV. Lowering the PV cell temperature also increases the electrical output for the modules tested and will undoubtedly do the same for most PV modules currently being installed. The illustration in Figure 6 shows a simple solution for the integration of PV cooling and thermal recovery on flat roof mounted systems.

for the crystalline PV panels and as much as 800 higher for the amorphous panels. For example, a 160 Watt PV panel actually produced over 700 Watts of total energy with 540 Watts of thermal energy making up the difference. The solar heat is normally used during the heating season whereas the electrical output is useable over twelve months. Heating air with the transpired collector is cost effective with only 5-9 months of utilization and should also be cost effective with PV/T. When space heating is not required, the solar thermal energy can be easily vented. If however, the summer solar heat can also be used for clothes drying, water heating, pool heating or process heating, then the economics improve even more. Fig. 6 Concept for typical roof mounted PV/T system connected to rooftop HVAC units The tests showed a temperature rise of 6 to 20 C above ambient. If a higher temperature is desired, a two stage solar heating system can be designed with the first stage as PV/T panel system and the second stage a glazed solar panel to receive solar preheated air from the first stage. It is desirable, however, to develop other uses for the heat in the summer months to make a PV thermal system even more cost effective, such as a desiccant cooling system. Utilizing the summer heat will improve the economics of a project and at the same time, recover heat that would otherwise be rejected to the atmosphere. These test results warrant investigating the application of PV/T systems in various geographical areas and climate zones, with and without the various incentives for PV installations. Fig. 7 Photo of PV/T on a residence in California The economic potential of a PV/T installation could be the subject of a separate study in itself due to the wide range of costs for electricity and heating fuels, weather data, uses for the thermal energy and ease of connecting to existing HVAC equipment. 4. CONCLUSIONS Test results from the National Solar Test Facility indicate that mounting the PV panels above SolarWall thermal panels will lower the PV panel temperature to an acceptable level. Lowering the cell temperature also increases the power output. The power output for the panels from BP and Evergreen increased at a rate of between 0.4 to 0.5/ per degree C of lower module temperature. All building integrated PV installations should evaluate the benefits of utilizing the rejected heat. 5. ACKNOWLEDGMENTS The authors are indebted to Doug McClenahan and Yves Poissant of Natural Resources Canada for providing funding for the IEA Task and solar simulator time, as well as to Alfred Brunger of the National Solar Test Facility for performing the tests. 6. REFERENCES 1. IEA Task 35 website: www.pv-t.org 2. Supplier panel specifications from Evergreen Solar, BP Solar, UniSolar and SolarWall. The tests confirmed that the thermal energy was much larger than the electrical energy, between 150 to 400 higher