This presentation premiered at WaterSmart Innovations. watersmartinnovations.com

Similar documents
Green Plumbing and Mechanical Code Supplement

Green Plumbing and Mechanical Code Supplement

Research of Grey Water for Use in Residential Applications Original date of publication: Updated:

Fiberglass Storage Tanks for Green Building Applications

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

DRAFT ONLY ORDINANCE NO.

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

Fiberglass Tanks for Green Building Applications. a subsidiary of ZCL Composites Inc.

Water Distress in Growing Cities Issues & Challenges. Presented by: Neeta Sharma Managing Director IAPMO India

AB 715 COVERS: Toilets and Urinals CHAPTERED AS: Health and Safety Code

WaterSense or Energy Star. Tank type toilets: WaterSense = 1.28 gpf (4.8L) with at least 350 gram waste. 1.5 gpm maximum & 0.8 gpm minimum at 20 psi

Monitoring Water Use

7.1 Conservation Programs for Industrial, Commercial, and Institutional Accounts

Water Use Reduction Additional Guidance

COOLING WATER MANAGEMENT

Green Globes for New Construction Pre-Assessment Checklist for Project Managers

Oregon Plumbing Rule and Law RV

Commercial Rainwater and

The New Realities of Water Recycling in San Francisco

Water Management Plan Revision 2

Green Codes & IGCC Update

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

WATER. Water Management Protect your building from water damage. Intent. Information & Tips

Proposed Revision to International Residential Code 2012 (as proposed to the ICC for IRC 2015)

100 Ways to Save Water

City of Elk River BASEMENT Office Use Only

Water LA. capture conserve reuse. California Adaptation Forum 2014 From Watershed to Coast: Adapting to Rising Seas & Prolonged Drought

Codes and Standards Research Report. California s Residential Indoor Water Use. 2 nd Edition (Revised May 8, 2015)

When it rains, it stores! Rainwater Harvesting in Australia

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Water Conservation and the State s New Green Building Code for Residential Construction

Sustainable Energy and Resource Saving Concepts for HVAC/Process/Water/Wastewater. Thomas H. (Tom) Durkin, PE Dr. Glenn Krueger, EdD Bob Jacobi

San Francisco s Non-potable Water Programs

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Georgia State Amendments to the International Plumbing Code

CHAPTER 26 PLUMBING CODE

Residential Water-Use Survey

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Common Causes of High Water Bills

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

Water Efficiency Self-Assessment Guide from

AIR-CONDITIONERS CONDENSATE RECOVERY SYSTEM FOR BUILDINGS

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Codes and Standards Research Report. California s Residential Indoor Water Use

ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS

RANCHO MURIETA COMMUNITY SERVICES DISTRICT WATER SHORTAGE CONTINGENCY PLAN

Energy Savings Performance Contracting. Guidelines for State Agencies. Part 2

Condensate Free Water

Water Pressure Reducing Valves

Eco-Schools USA Water Audit

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot

MECHANICAL ADMINISTRATOR LICENSE APPLICATION

Augmenting Rainwater Harvesting to Offset Potable Water for Irrigation and Indoor Use within the Tampa Bay Region A Best Management Practice

Water Conservation in Tucson Past, Present and Future. Fernando Molina Public Information /Conservation Officer Tucson Water

Yuba County Building Department Operation and Maintenance Manual

LIVING VICTORIA WATER REBATE PROGRAM 1 JULY 2012 TO 30 JUNE 2015 FOR UP TO 50 EMPLOYEES. Small Business

Berkeley s. guide. Best builders. to Conserving Water through Rainwater Harvesting & Graywater Reuse for Outdoor Use

PLUMBING PERMIT REQUIREMENTS AND CHECKLIST

Plumbing Code. City of San Diego 2013 Plumbing Regulations - Proposed Code Changes (revised 5/15/15)

Proposals for Water Conservation Programs in Yavapai County Water Advisory Committee April, 2007

On-site Non-potable Water Use

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

What to Expect From the Examination. How to Study the Plumbing Codes

Getting More Out of the Water We Have

REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

City of Hillsboro Inflow and Infiltration Elimination Program

RESIDENTIAL WATER SURVEY

San Diego County Parks and Recreation Water Conservation Plan

Plumbing Apprenticeship Program Curriculum

A Do-It-Yourself Home Water Audit

Plumbing Code Sections For Commercial Food Facilities

Backflow Bulletin #1

2012 British Columbia Plumbing Code Update

Water Shortage Contingency Plan

We ve got you covered.

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

Plumbing Code Statutes and Regulations February 2011 Labor Standards and Safety Division Mechanical Inspection

Plumbers Guide Pitt Town Water Plumbers Guide, December 21, 2012

UNIFORM PLUMBING CODE and UNIFORM PLUMBING CODE STANDARDS Edition

Sierra Nevada Brewing Co. Water Conservation Efforts. Fred Strachan

Introduction. Kitchens

Utility Service Application

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

MSHDA Affordable Green Enterprise Green Communities USGBC LEED

Plumbing Fixture Replacement (SB 407) for Existing Single-Family Residential, Multifamily Residential and Commercial Buildings

PLUMBING CODE REQUIREMENTS AND SIZING GUIDE FOR RESIDENTIAL WATER SOFTENERS. Second Edition. Prepared by

Transcription:

This presentation premiered at WaterSmart Innovations watersmartinnovations.com

Green Plumbing and Mechanical Code Supplement David Viola IAPMO Director of Special Services 1

IAPMO Group Association of the plumbing & mechanical industry One Goal: Public Health, Safety and welfare Develop Uniform Codes Test and certify plumbing, mechanical, and electrical products 2

IAPMO Green Uniform Codes - developed with critical eye on sustainability 2007- IAPMO Board calls for a reduction in energy and water consumption in the Uniform Plumbing and Mechanical Codes. Created Green Technical Committee (GTC) to accomplish goal. 3

GTC Diverse Group of Experts 25 experts in Green plumbing and mechanical fields Inspectors, contractors, plumbers and mechanics, engineers, manufacturers, trade associations, energy and water and energy conservation authorities. 4

GTC Task Groups 14 task groups (150+ people in total) Largest concentration of P&M sustainability experts ever assembled No other process comes close in sustainable P&M contact hours 2 to 3 meetings per year 20 + conference calls per year 100 + contact hours on P&M issues 5

GTC Task Groups Plumbing Fixtures and Fittings HVACR Hot Water Systems Water Pipe Sizing Alternate Water Sources Potable Rainwater Catchment Systems Life Cycle Assessment Irrigation Food Services Pools, Spas and Hot Tubs Natural Gas Hydronics Commissioning and Verification General/Administration 6

GTC Objectives Develop Green Plumbing and Mechanical Code Supplement Identify opportunities to make Uniform Codes more sustainable 7

GPMCS Overview FIRST green code Published in February, 2010 Turnkey document Residential and commercial sustainable plumbing and mechanical systems Covers all aspects of sustainability Water and energy efficiency Hot water system design Alternate water source use Indoor environmental quality 8

GPMCS Overview Bridge between codes and green building schemes Overlays ANY adopted plumbing code Baseline for sustainability No tiers of compliance or rating system Repository for future code provisions 9

GPMCS Development and Maintenance Consensus Continuous Nimble process to address emerging technologies Changes can be submitted at any time by anyone Submittal form posted on IAPMO website Next edition February 2012 10

GPMCS Development and Maintenance Currently out for public comment until November 7, 2011 For more information visit: www.iapmogreen.org/publicc omment Comments serve as agenda for December 8-9, 2011 GTC meeting 11

Broad Support 12

Adoptions Los Angeles water conservation ordinance Georgia Senate Bill 370, water conservation law Chicago Metropolitan Agency for Planning Model Water Conservation Ordinance City of Houston Plumbing Code South Dakota India Kuwait National Standard Plumbing Code- Appendix G Oregon Reach California AB 275 awaiting Governor s signature 13

What does it Cover? 14

Water Efficiency and Conservation 20% + more efficient than UPC Coverage areas: High efficiency plumbing fittings, fixtures and appliances. Occupancy specific provision in restaurants and medical facilities Water softening equipment Submeters HVAC systems 15

Alternate Water Source Systems (AWSS) Comprehensive provisions addressing Gray water Rainwater harvesting (nonpotable and potable) Reclaimed (recycled) water On-site treated nonpotable water systems. Design, installation and maintenance provision 16

Gray Water Untreated waste from: bathtub shower lavatory clothes washer laundry tub Irrigation only Commercial and residential use 17

Reclaimed (Recycled) Water Non-potable water provided by water wastewater utility Municipally treated High quality and reliability Based on UPC, Chapter 16 Irrigation and toilet and urinal flushing 18

Nonpotable Rainwater Catchment System Provisions Developed in tandem with ASPE/ARCSA Design Standard Applications: Flushing toilets and urinals Trap priming Irrigation Water features Cooling tower makeup water 19

Potable Rainwater Catchment System Provisions Based on ASPE/ARCSA Design Standard Provisions included in Appendix 20

On-Site Treated Nonpotable Water System 21

On-Site Treated Nonpotable Water System Gray water emphasized Condensate, rainwater, storm water can be used Fixture flushing, trap priming and irrigation System and components must be 3 rd party certified Installed in accordance with listing Required treatment: Chlorination UV sterilization Ozone 22

Water Heating System Design, Equipment and Installation Comprehensive provisions addressing water heating system efficiency. Equipment efficiency Insulation Recirculation Maximum volume of hot water System controls 23

What s New in 2012 24

Clarify scope of on-site treated nonpotable water sources 2010 emphasized gray water 2012 specifically includes: Gray water Black water Rainwater Stormwater Condensate Dry weather run off Keeps RWH section separate and simple 25

Clarify Who is Able to Design AWSS Systems 2010 required design by person registered or licensed to perform plumbing design work 2012 will also allow a person who demonstrates competency to design AWSS 26

Water Quality Req ts for AWSS 2010 required AHJ to determine minimum water quality No standards or broadly accepted guidelines were available 2012 will contain the following: Gray water treatment systems must be tested and certified to IAMPO IGC 207 or NSF 350. Effluent of RWH systems must meet minimum water quality parameters and testing 27

Efficient HW Systems Simplified maximum hot water volume calculations No recirculation or heat trace- 32 oz (1/4 gal) max from WH to fixture fitting Recirculation or heat trace 16 oz (1/8 gal) max for run out 28

Efficient HW Systems Recirculation pump control options: On demand Time clocks with temperature sensing 15 minute max operation time Sensors stop circulation when set temperature reached 29

Landscape Irrigation New comprehensive section addressing landscape irrigation systems Does not establish limits on landscape area or plant material Req rs irrigation controls to respond to climate or soil conditions Sensor to shut off system during rain event 30

Landscape Irrigation System performance requirements: Designed to prevent run off No supply line drainage Irrigation water is not permitted to be applied to non-target areas such as: Adjacent property Impervious surfaces Buildings Sprinkler head performance requirements Designers, installers and contractors must demonstrate competency 31

Plumbing Water Efficiency Performance Path 2010 established consumption limits on plumbing fixtures and fixture fittings 2012 Performance path being considered aggregate reduction in consumption of at least 20% to be calculated Baseline is EPACT and ASME A112.18.1 32

New Fixture Fitting Flow Rate Limits Kitchen sink faucet 1.8 gpm maximum May temporarily increase the flow to a maximum of 2.2 gpm Must default to a maximum flow rate of 1.8 gpm Still debating default trigger 33

New Fixture Fitting Consumption Limits Prerinse spray valve Reduced from 1.6 gpm to 1.3 gpm Dipper well faucets Metered flow not to exceed 2.2 gpm Continuous flow- not to exceed capacity of well in 1 minute 34

Automated Vehicle Wash Facilities 40 gallons max for automatic in-bay car washing 35 gallons max for conveyor car washing Recycle spot free rinse 3.0 gpm for spray wands and foamers 35

Evaporative Cooler Water Use (Swamp Cooler) 36

Evaporative Cooler Water Use (Swamp Cooler) 3.5 gal max per ton of cooling Consumption shall be indicated on equipment Overflow alarm Auto pump shut off Continuous discharge prohibited Discharge reuse in AWSS, where available 37

2012 UPC IAPMO philosophy - turnkey document Greenest plumbing code ever published New Chapter 17 addressing RWH Chapter 16 completely updated to incorporate the AWSS from GPMCS Expanded use of gray water Addition of on-site treated nonpotable water sources New appendix including GPMCS provisions 38

2012 UMC Greenest mechanical code ever published New section on geothermal systems New appendix including GPMCS provisions 39

Thank You Visit web page at: www.iapmogreen.org Contact: Dave Viola, Director of Special Services Email: dave.viola@iapmo.org Phone: (708) 995-3004 40