Nirvana. Cycling Refrigerated Dryers



Similar documents
Desiccant Air Dryers Heatless, Heated and Heated Blower

REFRIGERATED COMPRESSED AIR DRYERS

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Ingersoll Rand. Heat-Of-Compression Air Dryers

ThermoStar Refrigeration Air Dryers

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

ThermoSorb Desiccant Dryers

Refrigerated Compressed Air Dryers

Owners Manual 2009 PRICE LIST DRYMAXTM. Compressed Air Treatment Products. Refrigerated Air Dryers

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Rotary Screw Compressors UP-Series 4 & 5.5 kw

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

MAC-120HE-01 Air-Cooled Chiller

How To Clean Water From An Ammonia Refrigeration System

CRAC Precision climate control units for data centres

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Medical Air Systems: Scroll

Owners Manual. Refrigerated Air Dryer. HX75 thru HX2400

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Refrigerated Air Dryers. Catalogue

Refrigeration Compressed Air Dryer Buran Ultrapulse

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Refrigeration Air Dryers. Catalogue

Element D Services Heating, Ventilating, and Air Conditioning

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Defining Quality. Building Comfort. Heating and Cooling Coils

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Ultra Coolant. The Best Performance. The Best Cost. The Best Coolant.

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

DRYPOINT RA REFRIGERATION DRYER RANGE

LUBRICATED ROTARY SCREW AIR COMPRESSORS. 25 to 40 HP Sullair LS-10 Series Air Compressors. They re bulletproof.

Series IDU/IDF. Refrigerated Air Dryer

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

ECOCIAT. Domestic hot water heat recovery unit

How To Understand Evaporator

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Centrifugal Water Chillers. Scott Meyerkord

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

DESIGN STANDARDS SECTION

SMM. Installation Operation Maintenance

Cool Design for Homes and Offices

Laboratory & Scientific Line. Horizontal Steam Sterilizers

Lesson 36 Selection Of Air Conditioning Systems

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

ALL IN ONE. Heat Pump Water Heater

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Chilled Water HVAC Systems

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

PC1131 Electric Air Compressor

Rotary Screw Air Compressors SSR 55-75kW

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

ASME Packaged Indirect Fired Water Heater

Compressed Air Filters

LG Electronics AE Company, Commercial Air Conditioning

AIRROLLAIR COMPRESSORS E

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

AIR CONDITIONING TECHNOLOGY

Low GWP Replacements for R404A in Commercial Refrigeration Applications

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

PC1130 Electric Air Compressor

Distributed by: 2009 Ingersoll-Rand Company IRITS A

Rules for Classification and Construction Ship Technology

3/29/2012 INTRODUCTION HVAC BASICS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

FLASH TANK ECONOMIZER PRODUCT GUIDE

MUELLER FALLING FILM CHILLERS

NITROX // safer diving

Kompressoren. Adsorption Dryer AD

IV. Rear Mount System

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Using Portable Spot Air Conditioners in Industrial Applications

Ceiling Mount Air Handler Manual

EnviroAire Series. 15kW 110kW Oil-Less Rotary Screw Compressors ILLESS

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Compressed Air Systems

Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Creating Efficient HVAC Systems

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

Reducing the Cost of Keeping Office Data Centers Cool

Blade Server & Data Room Cooling Specialists

Kompressoren. Oil Water Separators OWS

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Packaged Glycol Chiller Systems Operation Manual

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Transcription:

Nirvana Cycling Refrigerated Dryers

Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class: reliability that you can count on to protect your air system day in and day out; reliability built in by design. High Heat Transfer at Work The superior performance of the Nirvana dryer can be attributed to the effective heat transfer capabilities of the exchanger design, utilized throughout the package for each stage of heat removal. The dryer design includes a pre-cooling system with stainless steel heat exchangers to properly condition the air for drying. A re-heater section of the dryer's air side also uses these high performance heat exchangers to prepare the dried compressed air for re-entry into the air system. This prevents pipe sweating and readies the compressed air for use in process applications. An innovative corrugated and folded stainless steel panel is stacked inside two stainless steel shells, then welded together to form a unitized heat exchanger. This design ensures reliability through the elimination of dissimilar metals or tube in tube chaffing, which is a common cause for heat exchanger leaks and failures. The Nirvana is a genuine cycling dryer, incorporating innovative features that make it not only the most reliable, but the most energy efficient, dryer in its class. The key element central to the Nirvana's reliability and energy efficiency is its distinct, patented heat exchanger design. Providing high heat transfer with low pressure drop because of uniquely short flow length, the Nirvana heat exchanger presents a flow area three to five times that of an equivalent copper tubing exchanger, and it is self-cleaning, which greatly reduces the potential for fouling. Corrosion-resistant 304L stainless steel is used in all the Nirvana dryer's heat exchangers, providing durability in environments unsuitable for copper or other metals. 100% stainless steel construction permits optimal heat transfer, resulting in a consistent pressure dew point. Nirvana dryer's heat exchangers combine a high heat transfer coefficient with unmatched low pressure drop. 2 Nirvana Refrigerated Dryer Nirvana Refrigerated Dryer 3

Energy-Efficient Design SYSTEM ENERGIZED DRYER ON DEGREE F DEGREE C HIGH TEMP. ALARM LOW TEMP. ALARM Nirvana An advanced cycling dryer, the Nirvana provides significant savings because it does not waste energy costs through continuous operation of its refrigeration system, as do traditional non-cycling dryers. Each component of the Nirvana has been designed to provide not only durability, but maximum energy efficiency. This combination of system design and individual component design adds up to the most energy efficient cycling refrigerated dryer available. Factors contributing to the Nirvana's energy efficiency: Design includes a refrigeration system combined with a thermal mass that efficiently stores cold energy. Refrigeration compressor cycles off during periods of reduced load, while dryer continues to remove moisture and contaminants from the compressed air. Unique centrifugal separator design provides effective moisture separation maintaining consistent dew point, regardless of partial load operation. Electronic No Air Loss (ENL) Drain Nirvana cycling dryers up to 2,400 SCFM are equipped with ENL condensate drains, which eliminate venting of compressed air to the atmosphere and are more reliable than traditional float- or solenoid-type drains. ENL Drain Best in Class Design The Nirvana cycling dryer uses centrifugal separation to remove moisture from the chilled air. Separation occurs at the coldest point in the system by means of centrifugal acceleration, then expands into an area of low velocity containing a sump, and change of air flow direction. The result is highly-efficient moisture removal, providing exceptionally dry, clean air under all operating conditions. Energy Consumed 100 90 80 60 40 20 0 Energy Use 0% 50% 100% Load Non-Cycling Dryer Nirvana Cycling Dryer Nirvana cycling dryers are highly efficient, providing dry, clean air under any operating conditions. REFRIGERATION COMPRESSOR ON ON OFF EXCH. SET ALARM RESET % SAVINGS F / C Microprocessor LED Controller up to NVC800 features a NEMA 1 package protection standard with an optional NEMA 4 rating. Microprocessor Controller The easy-to-use controller automatically manages dryer operation for optimum air treatment and for maximum energy efficiency. Simple and easily read interface with LED indication Digital display of chiller temperature available at a glance to ensure optimal dryer performance Percent of energy savings available at the touch of a button Automatic dryer restart in the event of a sudden loss of power Adjustable chiller temperature set point to further reduce energy expense Microprocessor control constantly monitors dryer functions including thermal mass temperature and provide alarms to minimize dryer downtime + _ 4 Nirvana Refrigerated Dryer

Large Capacity from 3,200 to 8,000 SCFM Modular design for exceptional reliability and energy efficiency Nirvana large capacity cycling refrigerated The moisture and contaminants are then compressed air dryers consist of multiple, automatically discharged from the system independent air treatment modules, each through pneumatic no air loss condensate with its own controls and refrigeration drains to eliminate wasting valuable system, sharing a central thermal mass cold compressed air. storage medium. Compressed air is cooled as it passes through the large capacity Nirvana Clean, dry compressed air is warmed as it exits dryer, causing moisture and contaminants the dryer to prevent pipe sweating and to to condense so they can be removed from condition it for application. The refrigeration the air in multiple high-efficiency centrifugal system in each module automatically cycles as separators. needed to maintain cold stored energy, while active circulation of the thermal mass cold storage media contributes to the dryer's overall efficiency. Redundant Design for Reliability The multiple air treatment modules of each Nirvana large capacity dryer are integrated to make a single dryer with air treatment capacities from 3,250 to 8,000 SCFM. (Larger dryer sizes upon request.) Modules share a single inlet header and a single outlet header, each with dual connection capability for installation versatility. Each module includes 304L stainless steel heat exchangers and a high-efficiency centrifugal separator. Because Nirvana large capacity dryers employ a shared, continuously-circulating thermal mass cold storage medium and integrated drying modules with individual electrical disconnects, the dryer can continue to operate and provide compressed air treatment even if a module must be isolated for maintenance or repair. Controller for NVC1000 and larger Microprocessor Controller Backlit LCD with integrated keypad allows viewing of dryer parameters regardless of environmental lighting MODBUS compatible via RS232/485-remote communication - ready connection port Expandable Large Capacity Dryers feature a modular design and individual controllers that provide redundancy for models starting at 3,250 SCFM. Dryer operation is coordinated through digital controls, fully adjustable to meet application requirements. The operation of individual modules can also be adjusted to make optimum use of the benefits associated with cycling refrigeration systems. Remote alarm contact available and remote start/stop ready Advanced diagnostic memory with failure code storage Percentage of energy savings available at the touch of a button Large Capacity Nirvana Cycling Refrigerated Dryers are also available in an air-cooled design. Water-cooled Large Capacity Dryer 6 Nirvana Refrigerated Dryer

How They Work Submerged Evaporator Thermal Mass Storage Tank is fully insulated to maintain a consistently cold propylene glycol-water mixture for continuous pressure dew point control. The thermal tank temperature is monitored by the controller permitting the refrigerant compressor to cycle off during low heat loads resulting in energy savings. Stainless Steel Pre-cooler/Re-heater assures that compressed air is properly conditioned for cooling while simultaneously reducing the energy costs of removing the initial heat load. Clean, dry air leaving the dryer is reheated to maintain low relative humidity in the process air, further protecting the compressed air system. Centrifugal Air/Moisture Separator efficiently and effectively removes moisture for all applications even under partial load conditions. Compressor Air Chiller uses stainless steel corrugated heat exchangers to provide efficient heat transfer between the compressed air and the dryer's cooling thermal mass, assuring a consistent and continuous 38ºF/3ºC pressure dew point. Moist Air Enters System Dry Air Exits System Condenser Filter Dryer Thermal Expansion Valve Pump Refrigeration System employs a reliable, time-proven hermetic reciprocating compressor. Thermal Mass Cooling System circulates the thermal mass fluid to provide a continuous cold medium for heat transfer. Compressed Air Side System pre-cools the inlet air, chills the air to 38 F/3ºC, removes moisture through the centrifugal separator and is re-heated for process use. 8 Nirvana Refrigerated Dryer Nirvana Refrigerated Dryer 9

Global Reach Unsurpassed Local Customer Support Ingersoll Rand provides its products and services directly or through distributors to customers in close to 200 countries. We focus on providing innovation to increase your productivity and profitability. Expect more with Ingersoll Rand. We are your total solutions provider. Specifications Air Capacity Operating kw Dimensions (in/mm) Model (SCFM 38ºF/ Pressure Drop Air Water W D H Approx. Ship Wt. Air In/Out 3ºC m3/min) (psig/barg) Cooled Cooled (lbs /kg) (in) NVC200 200/5.7 1.6/0.11 1.66 1.06 28/711 33/838 58/1473 620/282 1.5 NPT NVC300 300/8.5 2.1/0.14 2.54 1.65 28/711 33/838 58/1473 735/334 2 NPT NVC400 400/11.3 2.9/0.20 3.24 2.19 28/711 33/838 58/1473 745/339 2 NPT NVC500 500/14.1 2.9/0.20 4.65 4.28 42/1067 40/1016 62/1575 1250/570 3 NPT NVC600 600/17.0 3.0/0.21 4.82 3.14 42/1067 40/1016 62/1575 1275/580 3 NPT NVC700 700/19.8 2.7/0.19 5.79 3.58 42/1067 40/1016 62/1575 1320/600 3 NPT NVC800 800/22.7 2.9/0.20 6.50 4.16 42/1067 40/1016 62/1575 1415/643 3 NPT NVC1000 1000/28.3 2.4/0.17 7.03 4.48 32/813 76/1930 69/1753 2315/1052 4 FLG Long-term Value There is more to value than simply price. The commitment of many thousands of dedicated compressed air specialists, either directly employed or members of a select market channel partnership, mean that friendly Ingersoll Rand support is close at hand. In addition to parts availability, qualified on-site service is available globally. Preventative Maintenance and Warranty Factory training and certified Ingersoll Rand technicians can protect your investment by providing high-quality preventative maintenance. In addition, we can offer a comprehensive seven-year parts and labor warranty. Replacement Parts Made Easy Ensure that you have all the right parts on hand with our simplified ordering. Ingersoll Rand s reputation for dryer parts availability is second to none. The best overall value is getting the most out of your investment. Ingersoll Rand customer support teams will help you protect your investment. NVC1200 1200/34.0 3.1/0.21 8.72 5.48 32/813 76/1930 69/1753 2435/1107 4 FLG NVC1600 1600/45.3 3.3/0.23 11.48 7.34 32/813 76/1930 69/1753 2785/1266 4 FLG NVC2000 2000/56.7 3.5/0.24 13.18 9.09 34/864 91/2311 91/2311 4070/1850 6 FLG NVC2400 2400/68.0 3.5/0.24 14.29 9.59 34/864 91/2311 91/2311 4150/1886 6 FLG NVC3250 3250/92.1 3.0/0.21 18.03 14.77 75/1905 96/2438 100/2540 6330/2877 8 FLG NVC4000 4000/113.3 3.0/0.21 21.77 15.26 75/1905 100/2540 96/2438 7060/3029 8 FLG NVC4800 4800/136.0 3.0/0.21 28.72 19.32 75/1905 100/2540 96/2438 7200/3273 8 FLG NVC6000 6000/170.0 3.0/0.21 32.65 22.89 110/2794 98/2489 101/2565 9870/4486 10 FLG NVC8000 8000/226.6 3.0/0.21 43.54 30.52 143/3632 99/2515 102/2591 12575/5716 12 FLG Performance data presented in accordance with CAGI standard ADF 100 under 100 F inlet temperature, 100 F ambient temperature and 100 psig conditions. Maximum working pressure: NVC200-800, 230 psig; NVC1000-8000 SCFM, 220 psig. Weights and dimension shown for NVC200-2400 air-cooled, NVC3250 and larger in water-cooled. Average kilowatts per hour of dryer operation at full rated capacity. Standard NVC200-800 SCFM models ETL-certified, 1000-2400 models UL 508 panels. Available voltages 460-3-60, 575-3-60, 380-3-50. NVC200-400 available in 230-3-60 and 220-3-50. NVC200 available in 230-1-60. Pressure drop ± 0.5 psig. Correction Factors Dryer Selection Example: 500 SCFM 110ºF inlet 125 psig 100ºF ambient Calculation: Inlet Air Temperature Correction Factor 80ºF 1.64 90ºF 1.27 100ºF 1.00 110ºF 0.81 120ºF 0.66 Inlet Air Pressure Correction Factor 75 psig 0.91 100 psig 1.00 125 psig 1.08 150 psig 1.16 225 psig 1.22 Dryer Size = 500/(0.81 x 1.08 x 1.00) = 572 SCFM = NVC600 Ambient Air Temperature Correction Factor 80ºF 1.25 90ºF 1.12 100ºF 1.00 110ºF 0.86 120ºF 0.77 10 Nirvana Refrigerated Dryer Nirvana Refrigerated Dryer 11

Ingersoll Rand Industrial Technologies provides products, services and solutions that enhance our customers' energy efficiency, productivity and operations. Our diverse and innovative products range from complete compressed air systems, tools and pumps to material and fluid handling systems and environmentally friendly microturbines. We also enhance productivity through solutions created by Club Car, the global leader in golf and utility vehicles for businesses and individuals. www.ingersollrand.com Industrial Technologies P.O. Box 1840 800-D Beaty Street Davidson, NC 28036 (704) 655-5000 (704) 655-4039 Fax Ingersoll Rand compressors are not designed, intended or approved for breathing air applications. Ingersoll Rand does not approve specialized equipment for breathing air applications and assumes no responsibility or liability for compressors used for breathing air service. Nothing contained on these pages is intended to extend any warranty or representation, expressed or implied, regarding the product described herein. Any such warranties or other terms and conditions of sale of products shall be in accordance with Ingersoll Rand s standard terms and conditions of sale for such products, which are available upon request. Product improvement is a continuing goal at Ingersoll Rand. Designs and specifications are subject to change without notice or obligation. 2008 Ingersoll-Rand Company IRITS-0208-003