Greening The Data Center



Similar documents
Greener Pastures for Your Data Center

ECO-FRIENDLY COMPUTING: GREEN COMPUTING

Contact: Environment and Green Technologies Department Phone:

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Energy Savings in the Data Center Starts with Power Monitoring

Harmonizing Global Metrics for Data Center Energy Efficiency

Potpourri Track Green IT. Colin Martin Solutions Architect, Cisco Systems Inc.

3. Operational Highlights

Office of the Government Chief Information Officer. Green Data Centre Practices

EU Code of Conduct for Data Centre Efficiency

ENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

THE ACS BACKGROUND GENERAL COMMENTS

REDUCING ENERGY CONSUMPTION IN SCHOOLS: 12 Tips for Tackling an Energy Management Program K-12 WHITE PAPER

Operating Sustainable Facilities

BARRIERS AND SOLUTIONS TO CORPORATE ENERGY EFFICIENCY

SUSTAINABILITY CHARTER. May R&CA Sustainability Charter V1

KWE Basic Philosophy. As of March 2010, KWE is ISO14001 certified at 6 locations in Japan and 8 locations overseas

Increasing Energ y Efficiency In Data Centers

THE GREEN DATA CENTER

Enhancing Competitiveness through Sustainable Supply Chain. Clearstream Solutions. Greener Business

Environmental Benefits of Thin Computing A comparison of the environmental impacts of conventional desktop and thin computing

Data Centers: Definitions, Concepts and Concerns

Checklist: 12 Steps to a Greener Datacenter

IV. SHIFT TO THE CLOUD: ACHIEVING EFFICIENCY THROUGH CLOUD COMPUTING AND DATA CENTER CONSOLIDATION *

CASE STUDY: IIS GIVES A GLOBAL BEAUTY AND FASHION COMPANY AN IT MAKE-OVER MISSION ACCOMPLISHED

Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.0.0

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

ICT and the Green Data Centre

ALLIED PRINTING SERVICES, INC. CORPORATE SUSTAINABILITY AND ENVIRONMENTAL MANAGEMENT PROGRAM REPORT

GLOBALWORKPLACESOLUTIONS-ENERGY SERVICES. Reduce energy costs and greenhouse gas emissions across your portfolio

As a growing number of small- and medium-sized organizations (SMOs),

Guidance for the financial sector: Scope 3 accounting and reporting of greenhouse gas emissions. Summary of Scoping Workshop

Empowering Sustainability in Logistics

San Francisco Chapter. Deborah Grove, Principal Grove-Associates

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

The Power to Take Control of Software Assets

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Datacenter Efficiency

Energy management White paper. Greening the data center with IBM Tivoli software: an integrated approach to managing energy.

The business value of improved backup and recovery

Re Engineering to a "Green" Data Center, with Measurable ROI

Green IT Solutions From Desktop to Datacenter. Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.

ABB Australia Pty Limited. SF 6 gas management solutions Managing SF6 in switchgear installations

InfraStruxure Data Centre Management Software. Holistic open standards integrated data centre management solution.

Energy Management Solutions for a Better and Greener Government

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Fujitsu Group s Environmental Management: Outline of Environmental Protection Program (Stage IV)

AV Live Event Professionals: Sustainability Best Practices

Advantages on Green Cloud Computing

Environmental Policy. JRI Orthopaedics Limited

An Introduction to Data Center Infrastructure Management

Climate Change and Waste The Missing Link December 2010 Written by Jacob Gregory

Health, Safety and Environment Policy

Green Entrepreneurship. Oliver Ortis, Green Jobs Specialist, Green Jobs in Asia Project, ILO Indonesia Office Jakarta

Virtualization and the Green Data Center

NetVision. NetVision: Smart Energy Smart Grids and Smart Meters - Towards Smarter Energy Management. Solution Datasheet

Data Center Infrastructure Management (DCIM) Demystified

The Green Data Center

Measuring Energy Efficiency in a Data Center

EMC, VNX and ENERGY EFFICIENCY

Department of Veterans Affairs VA Directive VA Environmental Management Program

Green IT Promotion Council, Japan

Call to Action on Smart Sustainable Cities

How Microsoft Designs its Cloud-Scale Servers

BC43: Virtualization and the Green Factor. Ed Harnish

Sustainability: 5 Simple Ways Businesses Can Save at Work Tips from the Logistics Experts at UPS

Business Plan: Energy Conservation

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Transcription:

Greening The Data Center A Five Step Method for CIO s and Data Center Managers Professionals who manage Data Centers know what is expected from them for performance and uptime. What many are only just beginning to realize is that they will also be expected to address the environmental issues associated with Data Centers. Why?.. From 2000 to 2005 consumption of electricity by servers in Data Centers doubled. During those same years The price of oil went from $25 to $60 a barrel. The Governor of California ordered the State Government to reduce electricity use 20% (or more) below the amount used in 2003. 144 nations signed and began implementing the Kyoto Accords, committing to reduce Greenhouse Gas (GHG) emissions by 29%. The European Union (EU) approved the RoHS and WEEE directives that ban the use of Hazardous Substances in electronics and mandates recycling of all electronic equipment. California and 23 other U.S. states enacted or proposed restrictions on the disposal of e waste. In 2006 the U.S. Congress directed the EPA to study how much power is consumed by corporate and federal Data Centers, and what to do about it; Gartner Group said that half of the world s Data Centers will experience power shortages in the next two years. In the near future many U.S states will have mandatory GHG reduction programs, the EU will implement its Electricity Using Products (EuP) directive, governments and industry will launch major energy efficiency programs, and e waste restrictions will be tightened while Data Centers will continue to get bigger and see ever higher expectations for performance. It s clear that the future will bring increasing pressure for Data Center managers to use less electricity, buy greener equipment, take increased responsibility for the responsible management of e waste, and participate in meeting GHG emission reduction goals. The real question for Data Center managers is not Why but How? 1

How to Green Your Data Center in Five Not So Easy Steps Step 1 Know Your Stuff The first step in greening your Data Center is understanding, in detail, what you have, what you use, and why. This is the tedious, but essential, initial step that everyone wants to skip over. Who wants to waste time and money gathering data and analyzing it when you could be doing something to make things better? But, you can t manage what you can t measure. You can t measure progress unless you know where you started. You can t respond to data requests from management, regulators, or colleagues unless you have data good data on what you are doing and why. You can t make informed decisions about how to spend scarce dollars for the biggest impact, or ask for more money, unless you can show on paper what you have, what you use, and what it costs. In this first step you need to address Power Consumption, in total and broken down to the lowest equipment level possible. Power tracking products are available that enable accurate measurement over time. Consumption data needs to be translated into Power Costs associated with every element of Data Center operations. To make sense of power use and costs, a complete and accurate Hardware Inventory for equipment and an Application Inventory of the software and services is required. Once accurate data has been collected, new Performance Metrics need to be set, or old ones updated, for all of the equipment and applications. Another essential element of Step 1 is Benchmarking your performance against other Data Centers and other types of Facilities. Studies and data are available from internal resources, personal contacts, and private external organizations. In the near future, public benchmarking resources will likely be developed by government agencies to provide a forum for anonymous information sharing and standards of comparison. Step 2 Clean Up, Power Down, and Get Smaller Step 2 is about good housekeeping, management attention, and readily available technology solutions. The first task is to eliminate unnecessary equipment. Most people are familiar with the three R s of environmental responsibility: Reduce, Reuse, Recycle. GreenIT has developed the ER 3 Principle: first Eliminate, then go after the other three R s. The quickest way to lower electrical load, minimize space needs, and reduce cooling requirements is to get rid of equipment you don t need, including abandoned data cable, unused servers, and other equipment that accumulates over time. Once clean up is complete, develop Power Management Procedures for minimizing power consumption by all of the systems in the Data Center. The Cooling and Power Supply Efficiency for the Data Center facility should be evaluated, and investments made in tune ups, re design, or replacement for inefficient infrastructure. 2

Racks can be re stacked with more Energy Efficient Equipment. Based on the data collected in Step 1, Data Center managers can identify equipment consuming the most power and evaluate options for replacement or modification. In some parts of the U.S., utility companies offer cash rebates for the purchase of more energy efficient servers. Beyond simply shutting down old boxes, Virtualization of servers and storage is a technology being widely deployed to reduce the quantity of equipment needed in the Data Center. Reducing power bills by cutting heat load and power consumption through consolidation can produce savings to off set investment costs for more efficient technologies (even though the savings may go to someone else s budget!). Step 3 Make New Friends In the average Data Center today the biggest power draw is for cooling, and demands for additional space are constantly growing. Design and management of cooling systems, building power supply, back up power systems, and management of building space is assigned to Facilities Management in most organizations. They are also usually the people whose budget pays the rent, the utility bills, the waste management bills, operating permits, and fines. Many Facilities Managers (FM s) don t know much about IT and Data Center operations. But, they are learning fast. FM s are under increasing pressure to reduce costs and increase financial returns on those big ticket Balance Sheet assets. They have mandates to reign in energy consumption growth and reduce carbon emissions to meet corporate and government climate protection goals. They face new limits and restrictions on solid and hazardous waste management. And, IT systems or IT system infrastructure (power, wiring, wireless networks) are increasingly an integrated part of the building environment they must manage. Data Centers are a highly visible source of problems in all of these areas. Data Center managers should engage with colleagues in Facilities Management to develop protocols for Coordinated Operations and Integrated Planning. Architects, Engineers, Consultants, and Researchers who help design and construct Data Centers are others that Data Center managers should connect with to understand their disciplines and ideas, and to explain the realities of Data Center operations. Data Center Managers should also get involved with planning On Site Power Production, particularly from renewable, low carbon sources. Another part of the typical Enterprise that Data Center managers need to engage with is the Purchasing Department. Creating Green Specifications for equipment, material, and service purchases is not something Purchasing can do properly without assistance from IT professionals. 3

Step 4 Think Green, Be Green Reducing the environmental impacts of Data Center operations requires integrating green thinking into everything you do measurement and data collection, budgeting design and engineering, operations, and purchasing. Integrating all of these elements into a Design for the Environment program is something a few IT product manufacturers have been doing for some time. Data Center managers need to create their own ongoing programs for continual improvement. The cycle of continuous improvement starts with financial planning and budgeting. In a time where the purchase cost of a low end server may be less than the cost of the electricity that device uses in its lifetime, organizations need to develop methodologies for assessing Total Cost of Ownership for equipment, even though those costs appear in different budgets in different parts of the organization. Energy costs for operations, (and the associated GHG emissions) and end of life management costs for equipment need to be factored into financial analysis and forecasts before designs and specifications are set. Many organizations are beginning to develop methodologies for Life Cycle Assessments across the Enterprise that include financial, environmental, and operational factors. Many organizations, particularly in government, have Environmentally Preferable Purchasing policies that specify requirements and guidelines for all procurement decisions, including IT equipment. The specifications and guidelines frequently reference public certification standards such as Energy Star and EPEAT, which don t yet apply to Data Center equipment. However, those standards are in the process of being extended to servers. Truly committed purchasers can apply the same criteria to products without certifications and seek out products that exceed current standards. Going Beyond Compliance can only happen if IT professionals seek out the best solutions, drive the purchasing requirements, and incorporate environmental issues into all decision making processes. Data Center Managers also must work with Purchasing and Facilities on Product Life Cycle Management, E Waste Waste Management, and the reduction of solid waste streams. Many product manufacturers now offer Product Takeback services. Takeback clauses need to be written into purchase contracts and procedures developed to ensure implementation at the end of product life. Some manufacturers also offer green or reduced packaging waste options for new equipment, another requirement buyers should include in purchase specs. Buyers should also inquire about suppliers Environmental Management Systems (EMS) and ISO14001 Certification for their operations and product supply chain. 4

Step 5 Imagine a Greener Future Data Center design practices haven t changed much in decades. Today new, more energy efficient, greener technologies are available or in development. However, taking advantage of these new developments challenges many existing concepts and practices in the construction and management of Data Centers. Blade Servers are available now, but can lead to densities for power and heat that existing facilities infrastructure can t handle. Virtual PC s and other Thin Client Architectures are also available, and can have significant environmental advantages in system power consumption, reduced quantities of desktop equipment, and extended product lives. But, deployment requires a re thinking of overall IT system architecture for most Enterprises. Virtualization and new Multi Core Processors may also significantly effect the type and quantity of equipment to be installed in a Data Center. For facilities design, new technologies for Liquid Cooling at the rack level have been developed to address the heat removal requirements for high power, high density computing environments. Adoption of these designs can run counter to the practice of Data Centers as raised floor environments, creating a need for new cabling design and management practices. The use of Industrial Cooling Technologies adapted from other industries is another area of innovation being offered for energy efficient cooling at the facility level. For power efficiency, more efficient server power supplies are available today, as are new engineering approaches to eliminating inefficiencies in traditional systems with multiple AC/DC power conversions. Innovative designs for DC Powered Data Centers that could radically increase power efficiency are being researched and tested. Ultimately, the evolution of IT network technologies and management systems, changing ideas of how to provide for reliability and redundancy in networks, and the need to be environmentally responsible will challenge existing paradigms of what a Data Center is. Electrical utility companies are already planning for a future that includes far more distributed power generation, with a variety of renewable, nonpolluting power sources located close to the loads they serve. Pre fab Data Centers on wheels are available today, as are mobile, liquid cooled enclosures that can go most anywhere there is space, a power source, and a robust network connection. In the future, for many Enterprises, the Data Center may be more of a concept than a place. Greening your Data Center and building an environmentally sustainable future for IT will require imagination, new skills, and new thinking. It s a challenge but, it can be done. just start with Step 1. The difficult I ll do right now The impossible will take a little while. Billie Holliday Crazy He Calls Me 5