DUDERSTADT FOUNDATION & CONSTRUCTION, LLC.



Similar documents
Elevating Your House. Introduction CHAPTER 5

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

Lighthouse Engineering, L.L.C.

Metropolitan Builders Association Masonry & Concrete Standard

FY08 SEWER POINT REPAIRS BID TABULATION

Designed and Engineered to Perform

The unit costs are based on the trend line of the 3 low bids for the average quantity.

Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area

Texas Building Pros Foundation Repair Services

symptoms of a faulty foundation

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

Chapter 3 Pre-Installation, Foundations and Piers

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

Seattle Public Schools Building Excellence IV Projects Under Construction

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Page & Turnbull imagining change in historic environments through design, research, and technology

Chapter 9 Remedial Measures

Basement & Foundation Damage

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

IH-635 MANAGED LANES PROJECT, SEG. 3.2

DESIGNING STRUCTURES IN EXPANSIVE CLAY

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

School Construction Authority Architecture & Engineering

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012

GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER

SECTION EARTH MOVING

TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

SECTION 1 GENERAL REQUIREMENTS

Introduction to Minimal Excavation Foundations

Lighthouse Engineering, L.L.C.

Helitech Waterproofing & foundation repair. Heal your home with. Helitech. HELITECH Waterproofing & Foundation Repair helitechonline.

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Building Foundation and Structure

EAST LYME HIGH SCHOOL

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

SECTION INLETS INLET LOCATIONS

Hunter College school of Social Work Thesis Proposal

The minimum reinforcement for the stem wall is the placement of:

SECTION STORM DRAINAGE SYSTEM

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Rehabilitation of the Red Bank Road Bridge over Hoover Reservoir. Presented By: Doug Stachler, P.E.

High Strain Dynamic Load Testing of Drilled Shafts

Residential Foundations and Basements

SEWER BACKUP PREVENTION PROGRAM

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

TD AMERITRADE Park Omaha

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

RAM JACK INTRODUCTION

Geotechnical Building Works (GBW) Submission Requirements

Structural Foundation System

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

DAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

High Capacity Helical Piles Limited Access Projects

Safe & Sound Bridge Terminology

Meeting the Challenge of Pipeline Emergency Repair

How to Estimate the Cost of Support of Excavation for Foundation Installation. CPE Candidate No May 15, 2013

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils

How To Install An Overhead Sewer

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION STORM DRAINAGE TABLE OF CONTENTS

Section 402. STORM SEWERS

ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE

How To Repair A House

The International Workshop on Micropiles, 2007

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Section 2100-Trenching and Tunneling

Wastewater Capital Projects Management Standard Construction Specification

Lighthouse Engineering, L.L.C.

Basement Moisture Problems

Construction Technologies Career Field Pathways and Course Structure

Residential Building Permits Information

Plumbing & Foundation Repair Methods Tunneling Under a House vs Cutting Concrete Slabs 7 Myths Dispelled By Fred Marshall

Engineered Wood Foundations

GOOD NEWS BUT NOT ALWAYS

City of Shelbyville Site Inspection Checklist

REQUEST FOR QUALIFICATIONS FROM FOUNDATION REPAIR CONTRACTORS BROOMFIELD DEPOT FOUNDATION REHABILITATION PROJECT

C I T Y O F P E A R S A L L

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

Settlement of Foundations on Expansive Clays Due to Moisture Demand of Trees CIGMAT 2008

Architectural Inspection Site Structures

BMP #: Dry Wells / French Drains

COMMONLY USED RESIDENTIAL BUILDING CODES

CHAPTER 2 QUANTITY TAKE-OFF

SECTION STORM DRAIN SYSTEM

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

REQUEST FOR BOARD ACTION HENDERSON COUNTY BOARD OF COMMISSIONERS. ATTACHMENTS: 1. Construction Management Update

Architectural Processing and Inspections for Home Mortgage Insurance

Transcription:

DUDERSTADT FOUNDATION & CONSTRUCTION, LLC. Drilling since 1916 2215 Belknap Place Phone (210) 824-3800 San Antonio, TX 78212-1904 Fax (210) 824-9525 www.duderstadtfoundation.com

ABOUT THE COVER: Drilled piers were installed for an addition to the Robert B. Green Hospital in San Antonio, TX. Using a mule powered water well rig. The machine was converted for foundation drilling in 1923. This picture was taken prior to WWII.

DUDERSTADT FOUNDATION & CONSTRUCTION, LLC. DFC is a specialty contractor acting as prime contractor or subcontractor depending upon the scope of the project. DFC performs a large range of services using in-house personnel. Some of the services provided are: Tight quarter and low headroom foundation drilling Underpinning of commercial buildings Leveling of existing structures, including heavy, multi-story buildings Leveling and underpinning of historical structures Excavation under existing structures Foundation investigations Underfloor excavations French drains and waterproofing Surface drainage Concrete flatwork Concrete retaining walls Suspended cast-in-place concrete foundations Structural repairs General construction Tight quarter and low headroom foundation drilling capabilities include: Using the Backhoe with hydraulic drill Operating weight 15,000 lbs. Access required Width - 7' 6" Entrance height - 8' 0" Drilling height - 14' 0" Drilling capabilities Pier diameter - 12" to 48" Pier depth - 70' Bell diameter - 72" Rock capabilities yes The 480 Case tractor was used to drill piers inside an existing building at Lackland AFB. The suspended concrete floor was shored. Piers were 18 diameter, 52 deep with 54 diameter bells. Holes were cased to 20 with 13 headroom. Using the Bobcat with hydraulic drill Operating weight 10,000 lbs. Access required Width - 6' 6" Entrance height - 6' 7" Drilling height - 12' 0" Drilling capabilities Pier diameter - 12" to 36" Pier depth - 50' Bell diameter - 72" Rock capabilities yes The Bobcat equipped with a hydraulic drill was used to drill underpinning piers inside a school gymnasium. The 18 diameter piers were 25 deep with 42 diameter bells. The piers were used to lift the building over 8 inches.

Using the Mini Excavator Operating weight 9,500 lbs. Access required Width 6 Entrance height - 8' Drilling height 10 Drilling capabilities Pier diameter - 12" to 30" Pier depth - 40' Bell diameter - 72" Rock capabilities yes The Bobcat mini excavator was used to drill piers to underpin a building at St. Mary s University. The skid mounted hydraulic drill was used to drill the shaft for an elevator jack. The shaft was drilled in the basement of the historic Jones County Court House. The diameter of the shaft was 18, and the depth 42. Using the Mini Skid Steer Operating weight 2,000 lbs. Access required Width 3 Entrance height - 4' Drilling height 6 Drilling capabilities Pier diameter - 10" to 18" Pier depth - 25' Bell diameter - 36" Rock capabilities limited Using the DFC 53B hydraulic drill with separate hydraulic power source Operating weight 2,000 lbs. Access required Width - 3' 0" Entrance height - 6' 8" Drilling height - 8' 0" Drilling capabilities Pier diameter - 12" to 36" Pier depth - 70' Bell diameter - 60" Rock capabilities yes The mini skid steer was used in the Karnes County Court House to drill new piers for a suspended floor. DFC underpins commercial buildings using our specialized drilling equipment. The equipment allows for the placement of piers around landscaping, under roof overhangs, beneath canopies, and inside structures. The underpinning piers are usually installed as part of foundation leveling operations. The piers can also be used to shore damaged structural elements of a building or for stabilizing a building foundation.

DFC underpins historic buildings such as the historic Gift Chapel at Fort Sam Houston, the Hops House at the old Lone Star Brewery, the Boiler House at the Pearl Brewery, Comal County Courthouse and Mission San Juan de Capistrano. DFC has been leveling multi-story and heavy structures since 1966. Years of experience paired with the proper equipment has allowed us to successfully complete many challenging projects. Foundation types have included slab-on-grade, suspended concrete slabs supported on piers or spread footings, and stone foundations usually found on historic buildings. We have leveled churches, gymnasiums, schools, tower cranes, and office buildings. Investigation of existing piers and under-reams indicated that the piers were not installed according to specifications. All piers were replaced and the loads transferred to the new piers. The three story structure was leveled with a maximum lift of 6. The jacks shown are 150 ton capacity, lock ring hydraulic jacks. Fifty ton journal jacks were used where lighter loads permitted. Loads were transferred to the steel beams supported by new piers. The beams were encased in concrete after the leveling operation. A three story San Antonio office building was built using a mixed system of drilled piers and an interior slab-on-grade. The slab heaved and the piers settled. The interior slab was removed and the sub-grade excavated to accommodate the installation of a new suspended concrete floor system. Steel beams used to transfer the loads were encased in concrete after the leveling operation.

DFC is a certified installer of Chance Helical Products. Helical piers can be installed as an alternative to drilled piers. Helical piers are installed to underpin existing structures, as additional support for new construction and as tie backs for earth retaining structures. The installation time is faster than drilled piers and the helical piers can be installed in limited access situations. DFC installs helical piers when specified by the design professional. loaders. All of our excavation equipment is equipped with catalytic converters to maintain a healthy environment for workers and building occupants. Foundation problems can be caused by subsurface water. DFC has over fifty years experience installing french drains. French drains are often installed outside the building line to intercept subsurface water. We have installed french drains under existing buildings as part of water collection systems. Sump pumps are sometimes required to complete the drainage system. The installation of sump pumps is also within the scope of our operations. We install french drains as part of waterproofing systems to prevent leakage into basements. We also install waterproofing materials on basement walls. Installing a Chance Helical to level an elevator pit. DFC is often involved in the investigation of foundation failures. We aid the owners and their representatives in determining the cause and extent of foundation failures. We are often asked by engineers and architects for our advice in choosing the appropriate method of repairs, as well as estimates for the cost of repair. For over forty years, DFC has been involved in the excavation of soils from beneath existing structures. Soil can be removed to restore voids under structural elements or plumbing. The removal of soil is often required to access structural elements for foundation leveling. Soil removal can be accomplished by hand or using skid steer Protection board was installed over the waterproofing membrane before backfill was placed around the new structure. Proper surface drainage is essential to the performance of foundations built over expansive soils. DFC recommends surface drainage improvements as part of any plan to improve foundation performance. Years of experience enable us to provide the owner with practical solutions to surface drainage problems.

A grass covered swale was constructed parallel to an existing retaining wall to divert water collected from roof drains away from the below grade classroom. Retaining walls 8 6 tall were erected over the new suspended floor. Forms and shoring were still in place for the suspended floor system. Surface drainage around structures can often be improved by adding properly installed concrete or asphalt paving. Concrete walks and drives, when properly installed, are attractive and efficient means of redirecting surface water. DFC has years of experience in installing concrete flat work as part of surface drainage improvements. The installation of suspended concrete foundations also became part of our operation fifteen years ago. We limit our operation to smaller projects such as additions and mechanical rooms. Because of our excavation and pier drilling capabilities, DFC is able to handle the project from site excavation to the placement of concrete for the suspended slab. A reinforced concrete swale was installed between the existing retaining wall and the below grade classroom. The installation of concrete retaining walls has been included in our scope of work for the last twenty years. DFC uses Symons forms for cast-in-place concrete walls. We have constructed walls with cantilever foundations, drilled pier foundations, and a combination of both. We have experience constructing retaining walls using precast concrete wall panels inserted into wide flange columns supported by piers. Chemicals leaking onto this mechanical room floor deteriorated the concrete and reinforcing steel. The floor was removed and replaced with a new cast-in-place suspended concrete slab with ribs. For over forty years, DFC has been involved in repairing the structural members of concrete frame, steel frame, and precast concrete structures. Repairs have involved the total replacement of structural elements, epoxy injection of distressed concrete, and reinforcement of welded connections. Our

foundation leveling equipment and experience gives us the capabilities to shore damaged areas so that repairs can be made safely. We are often called upon to make emergency repairs to structures. Emergency shoring operations and emergency structural repairs have been completed at schools, shopping malls, and parking garages. This T-leg in a bank parking garage had been hit twice by oversized delivery trucks. The second accident damaged it beyond repair. It was necessary to shore the leg and repair it temporarily before it could safely be removed. Notice the patch on the adjoining T-leg. This concrete pier cap split and the intersecting precast beam was in danger of falling. The intersecting beam was shored for safety. A steel saddle was installed to support the beam and the pier cap was repaired. The damaged double T was removed to make way for its replacement. The temporary brace was removed after it was placed on the truck. DFC has performed many projects as prime contractor. Many of our contracts are obtained by competitive bidding. Other contracts are negotiated with the owners. We perform fixed price contracts as well as time and materials contracts. Structural repairs and foundation leveling were completed on this 1930 vintage 2-story concrete frame elementary school. Several beam supports failed and were repaired. The building was jacked 13 at one corner during the leveling operation. DFC is often involved in general construction projects. We choose projects that utilize as many of our areas of expertise as possible. Projects that include excavation, drilled piers, concrete forming, and placement allow us to utilize many of our skills. DFC usually acts as prime contractor on projects of this type.

The installation of a mechanical tunnel at the Northeast Baptist Hospital in San Antonio involved many areas of expertise, all performed by DFC personnel. Soldier piers were installed between buildings. The trench was excavated and the footing for the precast tunnel sections was installed. Precast tunnel sections were placed between structures. Cast-in-place concrete was used at both ends of the tunnel. As a subcontractor, DFC obtains work both by competitive bidding and by negotiating contracts. We pride ourselves in our ability to start and complete projects in a timely fashion. We are always willing to work with the prime contractor and other subcontractors to see that work progresses smoothly. Soldier piers were installed beneath the existing structure prior to final excavation. Skin friction had to be maintained on adjoining piers supporting the structure. The soldier piers were drilled with a 480 Case tractor and hydraulic drill. The final excavation was made beneath the structure using skid steer loaders. DFC was founded by Ed Duderstadt in 1916 and has been in constant operation since that time. Ed Duderstadt, working with W. E. Simpson Sr., P. E., installed the first drilled shaft foundations in the United States. Ed Duderstadt s son, Frank F. Duderstadt, took over the operation of the company in 1940. Frank F. Duderstadt s son, Frank J. Duderstadt joined the firm in 1978 after completing B. S. and M. S. degrees in Civil Engineering from Texas A & M University. Frank J. Duderstadt specialized in Geotechnical Engineering while studying for the M. S. degree. The firm is now owned by James Duderstadt, Frank J. Duderstadt s son. James has a degree in Construction Management from Sam Houston State University. Frank F. Duderstadt has retired and Frank J. Duderstadt has assumed the title of Sr. Project Manager. The father and son team has a combined experience of 55yrs.

DUDERSTADT FOUNDATION & CONSTRUTION, LLC. 2215 Belknap Place San Antonio, Texas 78212-1904 Phone (210) 824-3800 Fax (210) 824-9525 www.duderstadtfoundation.com