Intel RAID SSD Cache Controller RCS25ZB040



Similar documents
Accelerating Server Storage Performance on Lenovo ThinkServer

Performance Brief: MegaRAID SAS 9265/9285 Series

Intel Solid-State Drives Increase Productivity of Product Design and Simulation

Big Fast Data Hadoop acceleration with Flash. June 2013

MS Exchange Server Acceleration

EMC XtremSF: Delivering Next Generation Performance for Oracle Database

EMC VFCACHE ACCELERATES ORACLE

Intel RAID RS25 Series Performance

Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card

Optimizing SQL Server Storage Performance with the PowerEdge R720

Data Center Storage Solutions

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

Configuring RAID for Optimal Performance

Express5800 Scalable Enterprise Server Reference Architecture. For NEC PCIe SSD Appliance for Microsoft SQL Server

The Revival of Direct Attached Storage for Oracle Databases

Virtualization of the MS Exchange Server Environment

HP Smart Array Controllers and basic RAID performance factors

Benefits of Intel Matrix Storage Technology

High Performance SQL Server with Storage Center 6.4 All Flash Array

Improving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200

Answering the Requirements of Flash-Based SSDs in the Virtualized Data Center

Accomplish Optimal I/O Performance on SAS 9.3 with

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

Identity Theft. Credit Card Fraud. Hackers. Terrorists. It s scary out there.

Supreme Court of Italy Improves Oracle Database Performance and I/O Access to Court Proceedings with OCZ s PCIe-based Virtualized Solution

PrimaryIO Application Performance Acceleration Date: July 2015 Author: Tony Palmer, Senior Lab Analyst

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

LSI MegaRAID CacheCade Performance Evaluation in a Web Server Environment

Intel RAID. INTEL raid

All-Flash Storage Solution for SAP HANA:

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance

Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III

EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server

The MAX5 Advantage: Clients Benefit running Microsoft SQL Server Data Warehouse (Workloads) on IBM BladeCenter HX5 with IBM MAX5.

Intel RAID Performance 12Gb/s SAS RAID Controllers

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

Taking Virtualization

INCREASING EFFICIENCY WITH EASY AND COMPREHENSIVE STORAGE MANAGEMENT

Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments

Increase Database Performance by Implementing Cirrus Data Solutions DCS SAN Caching Appliance With the Seagate Nytro Flash Accelerator Card

Remote/Branch Office IT Consolidation with Lenovo S2200 SAN and Microsoft Hyper-V

Reduce Latency and Increase Application Performance Up to 44x with Adaptec maxcache 3.0 SSD Read and Write Caching Solutions

Microsoft SQL Server 2014 Fast Track

Driving Big Data with OCZ Enterprise SSDs

How To Build A Cisco Ukcsob420 M3 Blade Server

SLIDE 1 Previous Next Exit

THE SUMMARY. ARKSERIES - pg. 3. ULTRASERIES - pg. 5. EXTREMESERIES - pg. 9

Analysis of VDI Storage Performance During Bootstorm

Redundant Array of Independent Disks (RAID)

ServeRAID H1110 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers

Flash Storage Optimizing Virtual Desktop Deployments

EMC XTREMIO EXECUTIVE OVERVIEW

SanDisk SSD Boot Storm Testing for Virtual Desktop Infrastructure (VDI)

Using Synology SSD Technology to Enhance System Performance. Based on DSM 5.2

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products

How To Scale Myroster With Flash Memory From Hgst On A Flash Flash Flash Memory On A Slave Server

Boost Database Performance with the Cisco UCS Storage Accelerator

Lab Evaluation of NetApp Hybrid Array with Flash Pool Technology

NVM Express TM Infrastructure - Exploring Data Center PCIe Topologies

io3 Enterprise Mainstream Flash Adapters Product Guide

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

Intel RAID Controllers

Accelerating MS SQL Server 2012

Maximum performance, minimal risk for data warehousing

The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage

Data Center Solutions

RAID Basics Training Guide

Enabling the Flash-Transformed Data Center

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team

Intel RAID Web Console 2 and StorCLI Command Line Tool

Software-defined Storage at the Speed of Flash

præsentation oktober 2011

New economies of storage with the Compellent Flash-optimized solutions. Flash at the price of disk for I/O-intensive applications

Scaling from Datacenter to Client

Using Synology SSD Technology to Enhance System Performance Synology Inc.

Benefits of Solid-State Storage

Xserve Transition Guide. November 2010

The 8Gb Fibre Channel Adapter of Choice in Oracle Environments

Running Highly Available, High Performance Databases in a SAN-Free Environment

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

SUN ORACLE EXADATA STORAGE SERVER

Minimize cost and risk for data warehousing

white paper A CASE FOR VIRTUAL RAID ADAPTERS Beyond Software RAID

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

Accelerating Data Compression with Intel Multi-Core Processors

Managing the Data Deluge

Evaluation Report: Supporting Microsoft Exchange on the Lenovo S3200 Hybrid Array

Make A Right Choice -NAND Flash As Cache And Beyond

Upgrading Data Center Network Architecture to 10 Gigabit Ethernet

HP reference configuration for entry-level SAS Grid Manager solutions

IBM System Storage DS5020 Express

Hardware RAID vs. Software RAID: Which Implementation is Best for my Application?

Solid State Drive vs. Hard Disk Drive Price and Performance Study

Dell PowerEdge RAID Controller Cards H700 and H800 Technical Guide

SQL Server 2014 Optimization with Intel SSDs

Intel RAID Software User s Guide:

HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture

Transcription:

SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash

Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters. As the volume of data continues to increase in size and complexity, today s data centers need a cost-effective way to increase the performance of existing applications and processes. This is especially true for data centers who work with Big Data/Hadoop, Gluster and Virtual Desktop Infrastructure (VDI) environments that can include Web 2.0, HyperScale, cloud, OLTP, virtualization, data warehousing and data analytics. Now with the Intel SSD Cache Controller RCS25ZB040, powered by LSI NytroTM Technology*, organizations get smarter and faster storage that reduces total cost of ownership. It s the industry s only all-in-one solution integrating hardware RAID protection with onboard PCIe flash for data storage and/or intelligent read/write caching. The free integrated intelligent caching software removes I/O bottlenecks and increases performance in many applications including databases, indexing, Big Data/Hadoop, Gluster and VDI. It identifies frequently accessed data, or hot spots, and promotes them to the fast on-board flash. Also, since it allows the CPU to be highly efficient and focus on the application, rather than flash management, it provides the most dollar per IOPS and dollar per gigabyte of existing drive investment. The flexibility of the onboard flash allows data storage, including the boot volume, to free up server drive bays for increased server capacity and density. Overall it delivers up to 1TB of onboard flash-based cache and two 800MHz RAID-on-Chip processor cores to help accelerate business applications. With integrated boot, the Intel RCS25ZB040 frees up two drive slots to generate higher system efficiencies, with reboots that take seconds rather than hours. Plus, it significantly reduces degraded RAID array rebuild time during degraded states for these applications by fulfilling I/O requests from flash, allowing hard drive resources to focus on rebuild operations. The high level of data protection and availability makes storage solutions much safer. It replaces a RAID card or HBA in an existing configuration, delivering flash performance in all environments without adding server components. It s a simple option to add flash performance without investing in or qualifying SSDs. Since all Intel RAID solutions are validated across multiple platforms with Intel boards, chassis, and systems, when working together they provide a significant boost in performance and efficiency. Customized training, as well as service and support, make Intel the one source for customers seeking data protection, increased productivity, and simplified IT. Did you know that SSD Caching RAID acceleration can be more cost-effective than direct attach solid-state drive (SSD)-only arrays or short stroked hard disk drive (HDD) environments? Why Intel RAID SSD Cache Solutions? Integrated boot frees up two server drive slots with mirrored boot segments on the integrated NAND. RAID array rebuilds are accelerated with the possibility of time to optimal reduced from hours to minutes. Accelerate applications by up to 10X with caching hardware and software. Allows for highest performance without the need for write back cache (use of the DDR3 on the RAID card), which offers a significant TCO savings as cache backup units are not necessary. Near Plug and Play configuration with auto optimizing

How it Works The Intel RCS25ZB040 uses intelligent caching algorithms to identify frequently accessed data, or hot spots, and promote them to the fast on-board flash. It frees up the CPU and allows it to be highly efficient and focus on the application, rather than flash management. Exceptional ROC performance augmented with high speed flash The dual core LSI SAS2208 ROC and up to 1TB of flash significantly enhances the performance of mainstream applications. Advanced capabilities that don t require you to be an expert Built-in caching algorithms manage data transfer to and from the flash pool without the need for special code, application data structure knowledge or time spent understanding configuration complexities. Outstanding data protection and availability Supports data redundancy using SAS or SATA hard disk drives through mirroring, parity, and double parity (RAID levels 1, 5, and 6). Plus, it offers striping capability for spans (RAID levels 10, 50, and 60). Optimized flash use for both Reads and Writes Many competing flash caching technologies only feature Read use and do not allow Write capabilities. Writes can be mirrored to protect against data loss prior to the date being written to the designated RAID array. Faster rebuild during degraded states In a degraded array scenario, the time to optimal performance can be reduced by up to 75 percent. By partitioning space on the embedded NAND of Intel RCS25ZB040 for an OS (mirroring optional), 4 x 3.5 disk drives can be dedicated to storing data.

Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters. For organizations that work with Hadoop, VDI, SQL Server, MySQL and Oracle Databases, the Intel RCS25ZB040 PCIe, powered by LSI Nytro TM Technology*, provides substantial value. It offers significant performance increases, removes I/O bottlenecks, identifies frequently accessed data and promotes them to the fast on-board flash, improves latency and more. The following graph shows that when supporting more than 54 desktop sessions, the response time for the system with Nytro MegaRAID technology is significantly faster. 1 Using SQL Server with a Intel RCS25ZB040 card lowers SQL Server wait times, improves latency, and transaction throughput. 1 Sample chart regarding test results from baseline MySQL sysbench benchmark testing. 1 VDI The Intel RCS25ZB04 is designed to expedite data across a virtual desktop infrastructure (VDI) while decreasing the cost per desktop. It accelerates VDI performance through intelligent caching technology, which monitors frequently accessed data and retains it on its enterprisegrade flash for faster access. Plus, it moves data faster across a VDI and reduces the cost per desktop within the infrastructure. SQL Server By combining on-board flash technology with RAID-on-Chip (ROC) technology, Intel RCS25ZB04 accelerates key business applications in SQL server databases. It delivers low latency responses from flash storage and economy by using direct-attached HDD storage. Through intelligent caching algorithms the controller identifies application hot spots and stores this data onto its on-card emlc NAND flash. In a lab test designed to simulate a real world SQL Server, a latency reduction of 80% was observed for online transaction processing. 1 MySQL The Intel RCS25ZB04 can significantly reduce Capex and Opex expenses while delivering scalable I/O to critical B2B applications. When a major online Internet retailer tested the impact of the Intel RCS25ZB04 on server performance, specifically transactions per second, it found it improved server performance by nearly four times. Also, the controller is anticipated to contribute to a savings of nearly $3.7 million in CAPEX and OPEX over three years attributable to lower total hardware costs and reduced power consumption.

Oracle Database The Intel RCS25ZB04 significantly accelerates applications in an Oracle database by caching frequently accessed data and significantly reducing the latency required to access it. The benchmark results showed substantial performance gains in the average response times by utilizing the Intel RCS25ZB040 card to cache DAS-based HDD data.1 Through testing of a specific Oracle database simulating a real-world online transaction application, the latency of the DAS-based HDD array was nine times higher than the same array with Intel RCS25ZB040 installed. On the basis of this test, it is believed that the transaction response time for most Oracle databases with HDD array-based installations can be dramatically improved by adding an Intel RCS25ZB040. Since this add-in card has a low profile, MD2 profile form factor, it can be easily integrated into an existing DAS storage system. Furthermore, near Plug and Play set-up means that it can be installed without involvement from the database or application administrator. Apache Hadoop The Intel RCS25ZB04 can cut Hadoop execution times significantly and help IT teams reduce or redeploy up to a third of their servers in Hadoop environments. TeraSort was run on eight servers to measure the time required to complete the benchmark. This shows the same TeraSort job executed 33% faster. With Nytro technology.1 When the embedded flash and intelligent caching software of the Intel RCS25ZB04 drives Hadoop-based datasets, they can cut execution times by as much as 33 percent.1 Plus, these cards can spread Hadoop jobs over fewer machines, which results in lower capital costs and decreased data center cooling and power costs. In a typical data center installation of 1,000 servers, an estimated savings of nearly $7.4 million over three years, may be possible.

Intel RAID SSD Cache Controller RCS25ZB040 Faster, Smarter, and More Efficient Storage Acceleration Intel RCS25ZB040, powered by LSI Nytro TM Technology*, provides smarter and faster flash-based storage that can be used in numerous ways to help improve performance and server storage density. See real world examples of how the MegaRAID data protection and flexible onboard flash technology of LSI Nytro TM Technology* has helped improve storage infrastructures. Performance Benefits and More Data requests served from flash can significantly reduce application latency, which leads to improved user response times and quality-ofservice. The graph below compares the performance of a SQL Server database used in an online transaction processing (OLTP) workload with a hardware configuration with only HDDs, against an Intel RCS25ZB040- based configuration. A test found that the Nytro TM MegaRAID Technology* with intelligent caching and integrated flash storage yielded an 80 times faster response. Applications that benefit from caching can also benefit from reduced rebuild time for degraded RAID arrays, even when using high-capacity HDDs. With the Intel RCS25ZB040 servicing I/O from the onboard flash, the backend HDDs are less burdened and can dedicate more resources to the rebuild operation. Use Case: Leading Computer Solutions Company A leading provider of innovative computer solutions wanted to create a fast, robust, easily evaluated, installed and managed VDI solution designed to give its customers the performance they expected with a lower TCO. The Challenge: Typical VDI use cases can call for read/write ratios of 1:1, placing a strain on the I/O subsystem. To achieve densities of 50-100 virtual desktops per server appliance, the company needed to solve the disk I/O problem. The Solution: The company developed a server appliance with flash-based application acceleration powered by Intel RCS25ZB040. This enabled them to have better control over performance, component quality and a higher level of integration to make VDI functionality a drop-in for most IT departments. Use Case: University A major university wanted to find out if it should upgrade its Gluster configuration, an open source distributed file system, with the high-performance parallel file system FraunhoferFS (FhGFS). The Challenge: Since the university had already implemented Gluster, FhGFS would have to provide a number of compelling benefits to consider a move to the new architecture. The Solution: A newer FhGFS hardware configuration produced a 5 to 10 times performance increase compared to the older system used by the university. It achieved the upper range of improvement with 10 times the I/O when handling the large volumes of tested data. The RAID combination with embedded NAND and LSI Nytro TM MegaRAID Technology* helped to decrease the query time from a half to a third compared to the previous RAID solution.

Intel RAID SSD Cache Controller RCS25ZB040 Powered by LSI MegaRAID Technology* Intel RAID SSD Cache Controller RCS25ZB040 Technical Specifications Order Codes RAID Card with 256GB SSD Cache 2 : RCS25ZB040 RAID Card with 1TB SSD Cache 2 : RCS25ZB040LX Maintenance Free Backup Unit: AXXRMFBU3 Cable Kit: AXXCBL650MSMS or AXXCBL740MS7P RAID Levels and Spans RAID Levels 0, 1, 5, 10, 50, 60 Data Protection Online Capacity Expansion Feature Highlights Hot-Spare Support Global & Dedicated Single Controller Multipathing (Failover) Enclosure Management Background Consistency Checking Patrol Read for Media Functionality S.M.A.R.T. Support Intel RAID Software Intel RAID Web Console 2 Intel RAID Command Line Tool Intel RAID Flash Utilities I/O Processor LSI SAS2208 ROC running at 800 MHz Drive Types Maximum Drives Connectors Cache Memory SAS 6Gb/s or SATA 6Gb/s, SAS 3Gb/s or SATA 3Gb/s Up to 128 physical devices supported One SAS SFF8087 x4 SAS internal connectors Embedded 1GB at 800MHz PCI Interface x8 PCI Express* 2.0 Cache Backup Optional Intel RAID Maintenance Free Backup Unit AXXRMFBU3 Form Factor Low profile, MD2 (6.6 X 2.536 ) Data Transfer Rates Operating Temperature Operating Voltage Operating Systems Up to 6Gb/s per port Maximum ambient: 65 C (55 C with optional MFBU) +3.3 V Extensive support includes Microsoft* Windows* Vista/2008/Server, 2003/2000/XP, Linux*, Solaris*(x86), Netware*, FreeBSD*, VMware* and more. * Visit intel.com for the most complete list of supported operating systems For more information on the Intel RAID Cache Controller RCS25ZB040, visit: www.intel.com/go/raid For more information on how to make the Intel RAID Cache Controller RCS25ZB040 part of your server environment, please contact an Intel Channel Partner Program participant.

1 - Performance tests and ratings are measured using specific computer systems and/or components and reflect the approximate performance of Intel products as measured by those tests. Any difference in system hardware or software design or configuration may affect actual performance. Buyers should consult other sources of information to evaluate the performance of systems or components they are considering purchasing. 2 - The amount of NAND available for storage use is approximately 200GB for the card with 256GB of total NAND and 800GB for the card with 1TB of total NAND. INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR. Intel, the Intel logo, Intel Inside, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright 2013 Intel Corporation. All rights reserved. 0613/SJ/EM/PDF Please Recycle 328353-001US