Proactive Network Maintenance for EPoC



Similar documents
E P o C. IEEE P802.3bn Tutorial. Part 1. EPON Protocol Over Coax EPoC. Monday, 3 November 2014

DOCSIS 3.1: WHAT IS IT, HOW DOES IT WORK, AND HOW CAN YOU PREPARE FOR IT? Daniel Howard, SCTE CTO July 16, 2013

Technical Training Seminar on Practical Field Testing DOCSIS 3.0 for CCTA Member Companies August 24, 25 and 26, 2010 San Juan, Puerto Rico

DOCSIS 3.1. High Level Overview at NANOG 59. Karthik Sundaresan, Lead Architect. Oct 09, Cable Television Laboratories, Inc.

CX380X Advanced Spectrum and Burst QAM Analyzer

Cable Network Overview. Presented by: Ma1 Schmi1 (CableLabs)

Example: Multiple OFDM Downstream Channels and Examining Backwards Compatibility. Mark Laubach, Avi Kliger Broadcom

Channel Bandwidth, MHz. Symbol Rate, Msym/sec

Digital Signals and Testing

Technical Training Seminar on Troubleshooting the Triple Play Services for CCTA Member Companies August 24, 25, 26, 2010 San Juan, Puerto Rico

DSAM Digital Quality Index (DQI) A New Technique for Assessing Downstream Digital Services

DS2800. Broadband. Spectrum Analyzer. Key Benefits CUSTOMER PREMISE HFC DS

DVB-C2 a new Transmission System for Hybrid Fibre Coax Networks

1550 Video Overlay for FTTH

Broadband 101: Installation and Testing

Making Room for DOCSIS 3.1 and EPoC Is your cable plant ready for an OFDM world? Author - Phil Miguelez ARRIS

istock.com / alengo Broadcast and media Focus

Cisco Cable Radio Frequency (RF) FAQs

DOCSIS 3.1. Application Note. Products: R&S CLGD R&S FSW

Advanced Network Monitoring ANM

Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel

RADIO FREQUENCY INTERFERENCE AND CAPACITY REDUCTION IN DSL

VSE The all-new digital spectrum/video analyzer and noise troubleshooter

Characterizing Signal Leakage from an All-Digital Cable Network

Cable Modems. Definition. Overview. Topics. 1. How Cable Modems Work

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Deviser DS2800 Handheld Digital TV Spectrum Analyser

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Configuring Load Balancing and Dynamic Channel Change (DCC) on the Cisco CMTS

Ajay Gummalla-July 2001

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Channel Bonding in DOCSIS 3.0. Greg White Lead Architect Broadband Access CableLabs

AC3200 INTELLIGENT BROADBAND AMPLIFIER

ADSL part 2, Cable Internet, Cellular

Configuring Load Balancing and Dynamic Channel Change (DCC) on the Cisco CMTS

Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption

Public Switched Telephone System

E-Option Multi-taps Conditioning at the Tap

: Instructor

TROUBLESHOOTING VOICE-OVER-IP (VOIP) IMPAIRMENTS IN A DOCSIS NETWORK

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Module: Digital Communications. Experiment 784. DSL Transmission. Institut für Nachrichtentechnik E-8 Technische Universität Hamburg-Harburg

RF Measurements Using a Modular Digitizer

DSAM Digital Services Activation Meter

Optimizing IP3 and ACPR Measurements

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

BENEFITS OF USING MULTIPLE PLP IN DVB-T2

CS263: Wireless Communications and Sensor Networks

Pathtrak Return Path Monitoring System

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

How To Define Hfc Technology

MIMO detector algorithms and their implementations for LTE/LTE-A

Maximizing Receiver Dynamic Range for Spectrum Monitoring

Time and Frequency Domain Equalization

FCC CABLE RULES Technical Standards

LTE UE RF measurements An introduction and overview

Digital Transmission: Carrier-to-Noise Ratio, Signalto-Noise Ratio, and Modulation Error Ratio. January 2012

4 Digital Video Signal According to ITU-BT.R.601 (CCIR 601) 43

Evolution in Mobile Radio Networks

DOCSIS 3.0. The road to 100 Mbps. Greg White Principal Architect CableLabs

Performance Management and Fault Management. 1 Dept. of ECE, SRM University

VDSL2 A feasible Solution for Last Mile

Lezione 6 Communications Blockset

What s The Difference Between Bit Rate And Baud Rate?

OFDM, Mobile Software Development Framework

Adaptive Spectrum and Signal Alignment, Incorporated THE RE-PROFILER DSM CLOSES THE CASE ON DIAGNOSING DSL/VDSL TROUBLES

MoCA 1.1 Specification for Device RF Characteristics

Next Steps in the Evolution of the Broadband Network

SC-FDMA for 3GPP LTE uplink. Hong-Jik Kim, Ph. D.

Lecture 17: Wireless Networking"

Introduction to Digital Subscriber s Line (DSL)

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

The Analysis of DVB-C signal in the Digital Television Cable Networks

Implementing Digital Wireless Systems. And an FCC update

MODULATION Systems (part 1)

AIR DRM. DRM+ Showcase

Next Generation of High Speed. Modems8

Digital Services Activation Meter (DSAM)

DVB-T and DVB-T2 Transmitter Test Challenges

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

MATRIX TECHNICAL NOTES

Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)

Implementation of Digital Signal Processing: Some Background on GFSK Modulation

Testing Gateway LTE Performance

Understanding Dynamic Range in Acceleration Measurement Systems. February 2013 By: Bruce Lent

FPGAs in Next Generation Wireless Networks

Study on the Network Termination Point of Internet access and Telephony over Cable Networks (HFC)

Delaware Valley SCTE Comparing RF-over-Glass to HFC. Bill Dawson VP Business Development ARRIS Access & Transport bill.dawson@arrisi.

MoCA Testing for triple play and Whole Home DVR. Jim Carvajal Applications Specialist, Cable MSO Caribbean & Latin America

Digital Modulation. David Tipper. Department of Information Science and Telecommunications University of Pittsburgh. Typical Communication System

Evaluation Criteria for ADSL AFE1302

Hot Issues in Wireless Broadband Networking

Evolution from Voiceband to Broadband Internet Access

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP

1. (Ungraded) A noiseless 2-kHz channel is sampled every 5 ms. What is the maximum data rate?

How To Understand And Understand The Power Of A Powerline Microscope

Introduction to Wireless LAN Measurements

Transcription:

Proactive Network Maintenance for EPoC Contributors: Bruce Currivan, Richard Prodan, Thomas Kolze, Hesham ElBakoury, Bernard Arambepola, Belal Hamzeh, Mark Laubach www.broadcom.com

SUMMARY Cable operators require remote visibility into operation of cable plant and equipment Insert test points into CLT and CNU to enable characterization and troubleshooting of HFC plant Provide characterization of cable plant response, linear and nonlinear, and noise/interference evaluation Suport remote proactive troubleshooting of plant faults Goal is improved reliability and maximum throughput from well-maintained plant 2

EPOC SYSTEM DIAGRAM ONU & CLT ONU & CLT Source: EPoC Architecture Specification 3

TEST POINTS FOR HFC PLANT Each test point will be described at end of slide deck 4

CABLELABS PROACTIVE NETWORK MAINTENANCE (PNM) WORKING GROUP Approach Collect equalization coefficients and other metrics Measure wideband spectrum Analyze to locate impairments in cable plant Track record Reliably finds impairments in cable plant -- often before outage occurs High-resolution spectrum Strong reception by MSOs InGeNeOs = Intelligent Generation-Next Operational Systems Working Group at CableLabs, fka Proactive Network Maintenance (PNM) 5

PNM HISTORICAL TIMELINE Upstream adaptive equalization DOCSIS 1.1, circa 1999 CableLabs Proactive Network Maintenance WG 2007 Comcast Scout Flux Tool November 2009 Spectrum Analysis MIB definition Late 2012 Comcast Flux / Spectra Tool March 2013 6

PNM TOOL IMPLEMENTATIONS ACROSS CABLE INDUSTRY CableLabs Pre-EQ / SA Reference Charter DRUM / Node Slayer Comcast Scout Flux / Spectra Cox Edge Health Motorola Pre-EQ Response Tool Rogers F-Finder Time Warner Cable - ROI / Unified 7

UPSTREAM PRE-EQUALIZATION STEPS 1) Adapt Headend Equalizer to Channel CLT Adaptive Equalizer Cable Plant Ranging Signal CLT Pre- Equalizer 2) Copy Coeffs Into Pre-Equalizer (Update Periodically) CLT Adaptive Equalizer Equalizer Coefficients Cable Plant CLT Pre- Equalizer 3) Send Data Traffic Upstream CLT Adaptive Equalizer Cable Plant Data Packets CLT Pre- Equalizer 8

PRE- AND POST-EQUALIZERS CNU pre-equalizer does most of correction Pre-Equalized Frequency Response CLT post-equalizer cleans up residual Post-Equalized Frequency Response Equalizer Source: Comcast (Larry Wolcott) 9

PLANT FAULT LOCALIZATION USING PRE-EQUALIZER TAPS Source: PNM Best Practices Document 10

MAINTENANCE RESPONSE VS. ECHO LEVEL Source: PNM Best Practices Document MR = micro-reflection 11

SIGNATURES AND GROUPING Use signature clustering to locate common plant faults Source: Comcast (Larry Wolcott) 12

CALCULATING DISTANCE TO FAULT Equalizer response provides precise echo measurements so distances can be calculated Time-Domain Reflectometer (TDR) functionality Frequency Reflected Energy (Microreflection) Amplitude Source: Comcast (Larry Wolcott) 13

TDR FAULT LOCATION EXAMPLE Cable fault is one of the reflectors in a cavity consisting of at least 2 reflectors Measure TDR distance from one end of cavity: line amplifier, etc. Source: Comcast (Larry Wolcott) 14

FIXING BROKEN BURIED CABLE BEFORE AFTER Source: Comcast (Larry Wolcott) 15

SPECTRUM BEFORE AND AFTER CABLE REPAIR BEFORE AFTER Level (db) Frequency (MHz) 16

FAULTS DETECTABLE WITH FULL-BAND SPECTRUM ANALYZER IN EVERY CPE (CNU) Reflections Resonant Peaking 4G LTE Ingress FM Radio Ingress RF Notches Roll-off Filters Adjacency Source: Comcast (Larry Wolcott) 17

DESCRIPTION OF PROPOSED PNM TEST POINTS 18

PNM DOWNSTREAM TEST POINTS Symbol Capture: Capture wideband OFDM symbol at input and output of cable plant, solve for plant response Requires Trigger Message to synchronize capture at CLT and CNU, using PHY Link Channel (PLC) as a timing reference Alternatively, can define downstream probe and quiet symbol analogous to upstream CPE Spectrum Analyzer: Power spectrum of full downstream band Noise Power Ratio (NPR) Measurement: Examine spectrum of notch to see intermods and ingress Channel Estimate: Linear response of channel at CNU receiver Constellation Display: Shows impairments to QAM constellation Receive Modulation Error Ratio (RxMER) Per Subcarrier: Profile of SNR at receiver slicer vs frequency FEC Statistics: Codeword error ratio for each profile in use by CNU; CRC-40 error statistics Histogram: Shows nonlinear channel effects 19

PNM UPSTREAM TEST POINTS Capture for Probe Symbol: Send wideband probe symbol through cable plant, solve for plant response Capture for Quiet Period : View underlying noise floor when no desired signal is being transmitted Triggered Upstream Spectrum Analyzer: Power spectrum of full upstream band Impulse Noise Statistics: Power and duration of impulse events exceeding programmable threshold Equalizer Coefficients: Pre- and post-equalizer, giving linear response of cable plant FEC Statistics: Codeword error ratio for selected user; CRC-40 error statistics Histogram: Shows nonlinear channel effects 20

FEC STATISTICS PROVIDED Uncorrectables: Number of codewords that failed CRC-40 checksum, and number of total codewords Codeword error ratio vs time (seconds): CER in 1-second intervals for rolling 10-minute period Codeword error ratio vs time (minutes): CER in 1-minute intervals for rolling 24-hour period Short-term statistics: Report results when M errors have occurred or N codewords have been processed, whichever comes first RED/YELLOW/GREEN summary CNU status: Colors to be defined based on thresholds Upstream statistics are per-user; downstream are per-profile 21

RxMER MEASUREMENT Receive modulation error ratio (RxMER) is a measure of the average size of the noise ball surrounding each QAM constellation point (cluster variance). It is reported in db for each subcarrier frequency. RxMER is measured using the scattered pilots, which visit all subcarriers. Pilots are not subject to symbol errors as data subcarriers would be. This gives an accurate MER measurement over a wide dynamic range. RxMER is defined as the ratio of the average power of the equalized QAM constellation to the average error-vector power. The error vector is the difference between the equalized received pilot value and the known correct pilot value. The noise power of zero-valued subcarriers is also measured, and is expressed as an equivalent unequalized RxMER value. 22

EXAMPLE: WIDEBAND PROBE/CAPTURE Wideband probe at input to cable plant Spectrum of OFDM probe signal after channel Wideband probe at output of cable plant Spectrum of OFDM probe signal after channel 0 0-10 -10-20 -20 db -30 db -30-40 -40-50 -50-60 -60 550 600 650 700 750 800 850 Frequency (MHz) 550 600 650 700 750 800 850 Frequency (MHz) With known input and output samples, channel can be characterized including linear and nonlinear effects (compression, laser clipping, intermods(cso, CTB), common path distortion, ingress, group delay, plant leakage, ) Probe may be special probe symbol (upstream) or captured normal OFDM data symbol (downstream) 23

EXAMPLE: NOISE POWER RATIO (NPR) NPR probe through clean plant NPR probe after 3 rd order nonlinearity Spectrum of OFDM probe signal after channel Spectrum of OFDM probe signal after channel 0 0-10 -10-20 -20 db -30 db -30-40 -40-50 -50-60 -60 550 600 650 700 750 800 850 Frequency (MHz) 550 600 650 700 750 800 850 Frequency (MHz) Notch fills in with intermod products 24

POSSIBLE OFDM DS SPECTRUM REPORTING TRANSACTION CNU ODS-REQ CLT CNU Measures the SNR for each of its subcarriers. CLT does not need to run a timer; if no response from CNU, CLT will retry when convenient ODS-RSP (subcarrier ID = 0, SNR vector) ODS-RSP (subcarrier ID = 1920, SNR vecor) CLT remembers SNR vectors for later processing CNU CLT Source: Hesham ElBakoury 25

PNM OVERVIEW SUMMARY Cable operators require visibility into plant and equipment performance PNM has been adopted as the approach Provide characterization of cable plant response, linear and nonlinear distortions, and analysis of noise/interference Support remote proactive troubleshooting of HFC plant Goal is improved reliability, throughput and user experience Recommendation: Need to design-in test points in CLT and CNU that support PNM needs 26

IMPACT ON P802.3BN EPOC To support PNM, P802.3bn EPoC would need to provide the following: RxMER measurement support in the CNU Per sub-carrier, ratio of the average power of the equalized QAM constellation to the average error-vector power. For pilots, the error vector is the difference between the equalized received pilot value and the known correct pilot value. Straightforward, specifics are T.B.D. Performance monitoring, counters, measurements in CLT and CNU Rx Upstream and Downstream FEC performance and other counters Overview on next pages. Additional consideration Add Trigger message in the downstream PLC and measurement support in CNU Outside of the P802.3bn Specification OAM/eOAM messages for managing/gathering PNM statistics Suggestion: CableLabs address this activity 27

IMPACT ON CNU RX - DOWNSTREAM Overview Specifics are T.B.D.: The CNU would need to be capable of providing the following downstream performance metrics: Uncorrectable codewords: Number of data codewords that fail CRC-40 check Correctable codewords: Number of data codewords that failed pre-decoding LDPC syndrome check and passed CRC-40 check Unreliable PLC Codewords: Number of PLC codewords that failed LDPC post-decoding syndrome check Total number of data FEC codewords Total number of PLC codewords Total number of MAC packets Start and stop time of analysis period. The CNU would need to be capable of providing the following downstream FEC summaries on each OFDM channel being received by the CNU: Codeword error ratio versus time (seconds): Ratio of number of uncorrectable codewords to total number of codewords in each one-second interval for a rolling 10-minute period (600 values). Codeword error ratio versus. time (minutes): Ratio of number of uncorrectable codewords to total number of codewords in each one-minute interval for a rolling 24-hour period (1440 values). Ending time of rolling period. 28

IMPACT ON CLT RX - UPSTREAM Overview Specifics are T.B.D.: The CLT will need to be capable of providing the following FEC statistics for any single upstream user: Error-Free Codewords: Number of codewords that passed CRC-40 check Uncorrectable Codewords: Number of codewords that failed CRC-40 check Corrected Codewords: Number of codewords that failed pre-decoding syndrome check, but passed CRC-40 check Total number of FEC codewords Total number of MAC packets Start and stop time of analysis period The CLT MUST be capable of providing the following FEC summaries over a period of up to 10 minutes for any single upstream user: Total number of seconds Number of errored seconds (seconds during which at least one unreliable codeword occurred) Count of codeword errors (uncorrectable codewords) in each 1-second interval Start and stop time of summary 29

IMPACT ON PLC - DOWNSTREAM Overview Specifics and adoption are T.B.D.: Add a trigger message to the downstream PLC For synchronizing a measurement event between the CLT and group of CNUs Perform a capture at a specific time aligned with the PLC frame OFDM symbol time-domain data points equal to the FFT length in use Can likely adapt D3.1 PLC Trigger for use in P802.3bn EPoC 30

CONCLUSIONS FOR IMPACT ON P802.3BN PNM is a requirement in the cable industry P802.3bn EPoC will need to participate in PNM Further proposal work should include Support for required downstream and upstream Rx measurements Evaluation and consideration for use of the PLC trigger facility 31

SOME REFERENCES Scout Flux / Spectra: Empowering Operations With Equalization and CPE Spectrum Analysis, Presentation by Comcast Larry Wolcott, and Broadcom Bruce Currivan (excerpts in this package) CableLabs DOCSIS Best Practices and Guidelines (excerpts used in this package) http://www.cablelabs.com/specifications/cm-gl-pnmp-v02-110623.pdf 32

Thank You 33