ACE3600 HIGH PERFORMANCE MONITORING & CONTROL REMOTE TERMINAL UNIT



Similar documents
SECURE AND FUTURE-READY SCADA CONTROL SYSTEMS PREPARE YOUR CRITICAL INFRASTRUCTURE FOR WHAT HAPPENS NEXT

THE INDUSTRIAL INTERNET OF THINGS NEXT GENERATION TECHNOLOGY ENHANCING PRODUCTIVITY AND SAFETY

SOLUTION BRIEF Astro 25 conventional systems. ASTRO 25 conventional SYSTEMS. conventional systems

HMS Industrial Networks. Putting industrial applications on the cloud

the amount of data will grow. It is projected by the industry that utilities will go from moving and managing 7 terabytes of data to 800 terabytes.

SOLUTION BRIEF. Motorola FSA4000. How to Achieve Near 100% Fire Station Alerting Reliability

The data can be transmitted through a variety of different communications platforms such as:

Fire Station Alerting and Automation

WHITE PAPER. SCADA Systems

HMS Industrial Networks

Introduction To SCADA and Telemetry

Power network telecommunication

Efficient remote access to machines and plants with SIMATIC

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Network Management System (NMS) FAQ

Considerations for Hybrid Communications Network Technology for Pipeline Monitoring

Complete SCADA solution for Remote Monitoring and Control

Intelligent Device Management with DCS, PLC, and RTU

IP Sensing Water & Wastewater AMR/SCADA System

AutoLog ControlMan. Remote Monitoring & Controlling Service

Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications

QUICK REFERENCE GUIDE MOBILE HUMAN MACHINE INTERFACE (HMI): INNOVATION THAT EMPOWERS THE MOBILE OPERATOR

Security Issues with Integrated Smart Buildings

Integrated Communications Platform

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Remote Management White Paper 27th June, 2012

Deterrent and detection of smart grid meter tampering and theft of electricity, water, or gas

MOTOBRIDGE IP INTEROPERABILITY SOLUTION

WHITE PAPER. 4G: The Distributed Intelligence Revolution

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

Making the Case for Satellite: Ensuring Business Continuity and Beyond. July 2008

SCADA System Security. ECE 478 Network Security Oregon State University March 7, 2005

Motorola AirDefense Network Assurance Solution. Improve WLAN reliability and reduce management cost

Remote Communications Base Site Monitoring, Control and Management Automation System

ASTRO 25 SYSTEM FOR MISSION CRITICAL DATA LEVERAGE YOUR ASTRO 25 SYSTEM INVESTMENT FOR MISSION CRITICAL DATA

MSRC Best Practices. Communications Infrastructure Security, Access & Restoration Working Group

Telemetry, Monitoring & Asset Tracking: M2M Terminal Application Dynamics for Oil & Gas

Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist

Cyber Security Management for Utility Operations by Dennis K. Holstein (Opus Publishing) and Jose Diaz (Thales esecurity)

Improving SCADA Operations Using Wireless Instrumentation

Remote Monitoring and Satellite Communications

October Field Area Communication Networks for Digital Oil and Gas Fields

SECURITY SOLUTIONS BANKING AND FINANCE

Raven Electronics Corporation Specialized Communication Solutions Since 1968

Kepware Whitepaper. Enabling Big Data Benefits in Upstream Systems. Steve Sponseller, Business Director, Oil & Gas. Introduction

SCADA Systems Automate Electrical Distribution

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

Out-of-Band Networking

Smart Solutions for Network IP Migration

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

Professional Mobile radio. NEXIUM Wireless Mission-Critical LTE

A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems

Montgomery County Bus Rapid Transit System Information Technology Needs

This document describes how the Meraki Cloud Controller system enables the construction of large-scale, cost-effective wireless networks.

SCADA and Security Are they Mutually Exclusive? Terry M. Draper, PE, PMP

WHITE PAPER. Improving Operational Readiness for P25 Systems through Advanced Network Monitoring

Internet-Accessible Power Monitoring & Control Systems

FIRE STATION ALERTING HELPS MEET YOUR RESPONSE GOALS

Potential Targets - Field Devices

Advanced Transportation Management Systems

Communication Networks. We are securing the past in a fast moving future. FOX605 multiservice platform.

Endless possibilities

SCADA. The Heart of an Energy Management System. Presented by: Doug Van Slyke SCADA Specialist

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

LEASED-LINE REPLACEMENT

CG Automation Solutions USA

Network Communications System. Redefining Intelligent Utility Communications

Smart Anytime, Safe Anywhere. Home Passport Gateway-G Series. The Epitome of Smart Living

Manage Utility IEDs Remotely while Complying with NERC CIP

Network and Facility Management: Needs, Challenges and Solutions

SECURITY. SITUATIONAL AWARENESS. INTERAGENCY CONNECTIVITY.

AIRDEFENSE SOLUTIONS PROTECT YOUR WIRELESS NETWORK AND YOUR CRITICAL DATA SECURITY AND COMPLIANCE

Semaphore T BOX Applications in Data Center Facilities

Wireless LANs vs. Wireless WANs

How To Use Inmarsat M2M On A Sim Card

Failsafe Protection for Utility Critical Infrastructure

A NIMS Smart Practice

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

ENVIRONMENTAL MONITORING SYSTEM WITH WORLD-WIDE COVERAGE AND BIDIRECTIONAL COMMUNICATION VIA INMARSAT SATELLITE NETWORK

Automated Wireless Monitoring of Water Distribution Systems. A Telog White Paper

Wireless Technologies in Industrial Markets

Transporting Legacy Switched Digital Circuits Using a Packet Network

SCADA Systems. Make the most of your energy. March 2012 / White paper. by Schneider Electric Telemetry & Remote SCADA Solutions

MOTOBRIDGE IP INTEROPERABILITY SOLUTION

DIGITAL CONTROL SYSTEM PRODUCT SOLUTIONS

REMOTE MONITORING AND CONTROL SYSTEM

Power network telecommunication

Homeland Security Solutions


Remote monitoring & control solutions for cathodic protection rectifier

PLCs and SCADA Systems

Transcription:

HIGH PERFORMANCE MONITORING & CONTROL REMOTE TERMINAL UNIT PAGE 1

EMPOWER YOUR SCADA NETWORK Utilities, now more than ever, are facing newer and greater hurdles. Multiple wired and wireless communication technologies are challenges to seamless networking. Heightened security concerns amplify the need for secure connections. Operating flaws, system breakdowns and security failures are unacceptable. Versatile network interoperability, powerful data management and an intuitive user interface are mandatory. As the lead component in a SCADA system s remote monitoring and control capabilities. REMOTE TERMINAL UNITS (RTU) MUST FACE THESE CHALLENGES HEAD ON Operating within a wide variety of SCADA infrastructures and protocol requirements, RTU s must: Be versatile enough to support different communication media Adapt to existing and changing system requirements and platforms Encrypt information to protect against cyberattacks and false signals Be cost-efficient to maintain and operate for future growth Possess the robust processing to manage large amounts of data accuratelya SCADA network equipped to meet these demands requires the next generation of RTU from a communications leader, Motorola. PAGE 2

THE COMBINATION OF ACE3600 S FLEXIBILITY AND STRAIGHT FORWARD OPERATION MAKES IT THE PERFECT UPGRADE WITH MINIMAL COST AND EFFORT.

WIRELESS COMMUNICATION VERSATILITY ACE3600 is an all-in-one package that includes the RTU, radio and software for quick installation. The ACE3600 features a graphical user interface (GUI) that minimizes training time by allowing system conḁgurations and network operations to be managed through simple, user-friendly applications. The GUI includes program and system selfmaintenance software tools. ACE3600 operates with multiple industry protocols and across a wide band of communication media, including: Fiber-optic links Telephone and leased lines VHF/UHF/800/900 MHz conventional systems UHF/800/900 MHz analog or digital trunked systems Multiple Address Systems (MAS) Broadband data over Internet Protocol (IP) Spread Spectrum communication Microwave Satellite Narrowband and broadband at speeds from 1200 bps to 100 MB This flexible communications capability enables the ACE3600 to connect with several local devices, analyze the data and send that information via different media to various other locations. ACE3600 also accommodates a host of devices, sensors and display elements and has hot-swappable input/output (I/O) modules with Sequence of Event Recording (SER). Available on-board ports can feature up to: Three 10/100Base-T ports Four serial ports Two radio modem ports PAGE 4

ACE3600 ROBUST TRANSMISSION PROCESSING The ACE3600 s processing power provides accurate data analysis for the most critical, real-time monitoring and control applications. A CE3600 s Optimized Wireless Protocol works in concert with its flexible communication capabilities to gather and analyze data from multiple sensors or other intelligent electronic devices (IED), at any number of remote sites. T ransmissions from sensors and IED s can be sent accurately and dependably to any number of locations or any computer that has access to an Internet/Intranet connection and a standard Web browser. T he RTU acts as a communication node or Storeand-Forward repeater, allowing for coverage extension or data transfer between RTU s in the event of a disruption in service. This enables redundant data transfer for an even higher level of security, dead-spot elimination and additional reliability. T he ACE3600 eliminates the need to make a choice between an RTU and PLC, by incorporating the best features of mid-sized PLC functions to provide local programming for control with intelligent RTUs protocol and communication capability. PAGE 5

THE LATEST IN SECURITY Maintaining the integrity of SCADA systems requires an RTU network that sends and receives data securely. Providing security through reliable operation and automated disruption protection, the ACE3600 provides increased data security through multiple layers of encryption and time-based data authentication. FEATURES AT-A-GLANCE ACE3600 can be used as a secure router with data sent to the RTU from various non-secure sources and held for secure forwarding. ACE3600 s ability to diagnose, calibrate, program and update other RTU s alleviates technicians spending time canvassing remote sites, provides immediate assessment of a failure, and reduces service downtime. Over-the-air uploads and downloads of data and programs are performed between RTU s or the control center for diagnostics in the event of an accidental or malicious disruption. ACE3600 allows for the remote download of new firmware. Rigid password security protects the system from unauthorized access. Motorola s secure SCADA and Motorola Data Link Communication (MDLC) protocol is the trusted solution used by numerous Federal agencies and military bases across the globe. PAGE 6

VERSATILE PLATFORM FOR MULTIPLE APPLICATIONS WASTEWATER CONTROL Implement pump sequencing to minimize power costs and equalize runtime. Support one or more variable speed pumps. Flexible to handle the smallest lift station tasks or the most complicated treatment plant process. Makes an ideal intelligent data logger for mandated combined sewer overflow (CSO). POTABLE WATER Monitors well parameters for sophisticated pump sequencing control and alerts. Maintains water levels at the reservoir/water tower, and optimize flow and pressure in the distribution grid. Provides critical response system fault detection for leaks or unauthorized water use. PUBLIC WARNING SYSTEMS Provides secure communication between the sirens and the control center. Provides back-up communications, silent test and download of recorded public warning messages, and siren activation. Expands communication capabilities through a select combination of tones and pre-recorded voice messages. OIL AND GAS SAFETY Continuously monitors, measures and controls different aspects of the production, refining, transportation, storage and distribution of oil and gas. Measures oil and gasflow rates per American Gas Association (AGA) standards, accumulated flows, line and wellhead pressures. Analyzes, coordinates and controls with enhanced system monitoring to manage oil spills, leakage and fire detection and emergency shut down procedures. FIRE STATION ALERTING SOLUTION Alerts specific bunkroom(s), waking only the appropriate response team(s) reducing work, stress and fatigue. Protects the fire station from theft by closing the doors after the engines have left. Guards against a fire in the fire station by shutting down designated high-risk areas within the station, such as the kitchen, which are quickly left unattended during an emergency. ELECTRICAL DISTRIBUTION Monitors and controls transformers, substation protection relays and circuit-breaker reclosers utilizing detection technology to register which feeder sections experience a fault current. Uses advanced communication capabilities for fault isolation and system restoration to remotely isolate a damaged MV power grid section and restore power to customers. Regulates voltage and the power factor through remote control of capacitor banks along the grid providing more accurate billing and a reduction in energy losses along the network. Helps power generation stations to effectively meet the growing demand for electricity through power quality monitoring. PAGE 7

RELIABLE CONTROL SYSTEMS FROM A VENDOR WHO UNDERSTANDS WIRELESS COMMUNICATIONS. Only Motorola s 75 years of experience designing and manufacturing secure, mission critical communications systems can provide the most versatile, secure and accurate SCADA operating system for your business. For 35 years, over 120,000 Motorola RTUs have been installed all over the world in a variety of applications. For more information about ACE3600 and Motorola s commitment to the SCADA industry, please visit us on the web at www.motorola.com/caribbean/twowayradiosystems MOTOROLA, MOTO, MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC and are used under license. All other trademarks are the property of their respective owners. 2011 Motorola, Inc. All rights reserved.