STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts



Similar documents
DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

How To Use A Cat Diesel Engine

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

C18 Diesel Oilfield Generator Set

DIESEL GENERATOR SETS

C18 ACERT Fire Pump Tier bkw/ rpm

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

3516 Industrial Engine

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Spark-ignited generator set

Diesel Engine Driven Generators Page 1 of 6

Diesel Generating Set

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

How To Control A Power Command Powerplant

Diesel Generator Set Model DGDK 60 Hz

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFMB 60 Hz

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

3516B Offshore Generator Set

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

INDUSTRIAL ENGINE RATINGS GUIDE

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Annex-A TECHNICAL SPECIFICATION

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

3516B Offshore Emergency Generator Set

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

X G R E N T A L

Magnum Mobile Generator MMG55 Specifications

CAT CG132. Series Gas Generator Sets

APS100 Rental Generator Set Specification

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Atlas Copco Generators

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

The kva RAnge

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED

LOAD BANK TESTING PROCEDURE

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Technical Specification. Generating Set with Waukesha engine burning natural gas

IGSA POWER GENERATION SYSTEMS

Integrated Power Systems for Data Centers

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

PM734F - Technical Data Sheet Winding 28

Marine Generating Sets 3.7 to 50 kva

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Process Alarm Solutions

POWER YOUR TELECOM SITE WITH OLYMPIAN Hybrid Power for Telecom Applications Solar Photovoltaic Wind Diesel Battery

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Power Your Telecom site with olympian Hybrid Power for Telecom Applications Solar Photovoltaic Wind Diesel Battery

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

POWER GENERATION.

SG035. Industrial Gaseous Generator Set. SG035 35kW. primary codes and standards. Standby Power Rating 44kVA 35kW 60Hz

EMERGENCY AND STANDBY POWER SYSTEMS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Fire Pump Plan Review March 2010

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Digital generator set 1302 control kit

EGSTON Standard E2xFxWx 12W

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Power Generation generator sets kva to 15 MW

HEAVY-DUTY, REDEFINED. REDEFINED.

May, ArACBMENT I. Review of. Diesel Generator Alan and Control Circuitry. Indian Point Units No. 2 and 3. Docket Nos.

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

The reliability of the grid

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Bill of Materials Re: 2250KW. Item Description Qty

SWITCHGEAR. EGP Switchgear

A Single Source for all Power System Solutions

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Oil and Coolant Circulating Heating System. Model - OCSM

Power Generation. Power Control PCL System Generator Set Control

Transcription:

DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES FUEL/EMISSIONS STRATEGY EPA for Stationary Emergency Application (EPA Tier 2 emissions levels) DESIGN CRITERIA The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. UL 2200/ CSA - Optional UL 2200 listed packages CSA Certain restrictions may apply. Consult with your Cat Dealer. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost installation SINGLE-SOURCE SUPPLIER Fully prototype tested with torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries The Cat SM program cost detects internal engine component condition, even the presence of unwanted and combustion by-products CAT C27 ATAAC DIESEL ENGINE Utilizes ACERT Technology Reliable, rugged, durable design Four-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Electronic engine control CAT GENERATOR Designed to match the performance and output characteristics of Cat diesel engines Single point access to accessory connections UL 1446 recognized Class H insulation CAT EMCP 4 CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway SEISMIC CERTIFICATION Seismic available Anchoring details are site and are dependent on many factors such as generator set size, weight, and concrete strength. IBC requires that the anchoring system used is reviewed and approved by a Professional Engineer Seismic per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 Pre-approved by OSHPD and carries an OSP-0084-10 for use in healthcare projects in California

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Air cleaner Cooling Package mounted radiator Exhaust Exhaust flange outlet [ ] Exhaust mufflers Fuel Primary fuel filter with integral water separator Secondary fuel filters Fuel priming pump Generator Matchedto the performance and output characteristics of Cat engines [ ] Oversize and premium generators [ ] Permanent magnet excitation (PMG) [ ] Internal excited (IE) [ ] Anti-condensation space heaters Power Termination Bus bar [ ] Circuit breakers, UL listed [ ] Circuit breakers, IEC compliant Control Panel EMCP 4 Genset Controller [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4 [ ] Generator temperature monitoring and protection [ ] Load share module [ ] Digital I/O module [ ] Remote monitoring software Mounting [ ] Rubber vibration isolators Starting/Charging [ ] Battery chargers [ ] Oversize batteries [ ] Jacket water heater [ ] Heavy duty starting system [ ] Charging alternator General Paint - Caterpillar Yellow except rails and radiators gloss black The following options are based on regional and product configuration: [ ] Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 [ ] EU Certificate of Conformance (CE) [ ] UL 2200 package [ ] CSA Certification [ ] EEC Declaration of Conformity [ ] Enclosures- sound attenuated, weather protective [ ] Automatic transfer switches (ATS) [ ] Integral & sub-base fuel tanks [ ] Integral & sub-base UL listed dual wall fuel tanks 2

SPECIFICATIONS CAT GENERATOR Frame size... 1268 Excitation... Permanent Magnet Pitch... 0.6667 Number of poles...4 Number of bearings... Single bearing Number of Leads... 012 Insulation... UL 1446 Recognized Class H with tropicalization and antiabrasion - Consult your Caterpillar dealer for available voltages IP Rating...Drip Proof IP23 Alignment... Pilot Shaft Overspeed capability...150 Wave form Deviation (Line to Line)... Less than 5% deviation Voltage regulator...... 3 Phase sensing with selectible volts/hz Voltage regulation...less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) CAT DIESEL ENGINE C27 TA, V-12, 4-Stroke Water-cooled Diesel Bore... 137.20 mm (5.4 in) Stroke... 152.40 mm (6.0 in) Displacement...27.03 L (1649.47 in 3 ) Compression Ratio... 16.5:1 Aspiration... TA Fuel System... MEUI Governor Type... ADEM A4 CAT EMCP 4 SERIES CONTROLS EMCP 4 controls including: - Run / Auto / Stop Control - Speed and Voltage Adjust - Engine Cycle Crank - 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions Digital indication for: - RPM - DC volts - Operating hours - Oil pressure (psi, kpa or bar) - Coolant temperature - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - ekw, kva, kvar, kw-hr, %kw, PF Warning/shutdown with common LED indication of: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Programmable protective relaying functions: - Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kw) (32) - Reverse reactive power (kvar) (32RV) - Overcurrent (50/51) Communications: - Six digital inputs (4.2 only) - Four relay outputs (Form A) - Two relay outputs (Form C) - Two digital outputs - Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Emergency stop pushbutton Compatible with the following: - Digital I/O module - Local Annunciator - Remote CAN annunciator - Remote serial annunciator 3

TECHNICAL DATA Open Generator Set - - 1800rpm/60 Hz/480 Volts EPA Certified for Stationary Emergency Application (EPA Tier 2 emissions levels) DM7696 Generator Set Package Performance Genset Power rating @ 0.8 pf 1000 kva Genset Power rating with fan 800 ekw Fuel Consumption 100% load with fan 216.9 L/hr 57.3 Gal/hr 75% load with fan 171.7 L/hr 45.4 Gal/hr 50% load with fan 122.3 L/hr 32.3 Gal/hr Cooling System 1 Air restriction (system) 0.12 kpa 0.48 in. water Engine coolant capacity 55.0 L 14.5 gal Inlet Air Combustion air inlet rate 62.8 m³/min 2217.8 cfm Exhaust System Exhaust stack gas temperature 511.4 º C 952.5 º F Exhaust gas rate 170.3 m³/min 6014.1 cfm Exhaust size (internal diameter) 203 mm 8 in Exhaust system backpressure (maximum allowable) 10.0 kpa 40.2 in. water Heat Rejection Heat rejection to coolant (total) 330 kw 18767 Btu/min Heat rejection to exhaust (total) 796 kw 45268 Btu/min Heat rejection to aftercooler 162 kw 9213 Btu/min Heat rejection to atmosphere from engine 110 kw 6256 Btu/min Heat rejection to atmosphere from generator 40.3 kw 2293.9 Btu/min Alternator 2 Motor starting capability @ 30% voltage dip 3641 skva Frame 1268 Temperature Rise 125 º C 225 º F Lube System Sump with 68.0 L 18.0 gal Emissions (Nominal) 3 NOx g/hp-hr CO g/hp-hr HC g/hp-hr PM g/hp-hr 5.18 g/hp-hr.23 g/hp-hr.03 g/hp-hr.024 g/hp-hr 1 For ambient and altitude capabilities consult your Cat dealer. Air restriction (system) is added to existing restriction from factory. 2 Generator temperature rise is based on a 40ºC ambient per NEMA MG1-32. UL 2200 Listed packages may have oversized generators with a temperature rise and motor starting characteristics. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77ºF, 28.42 in HG and number 2 diesel fuel with 35º API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. 4

RATING DEFINITIONS AND CONDITIONS Applicable Codes and Standards: AS1359, CSA C22.2 No 100-04, UL142, UL489, UL601, UL869, UL2200, NFPA 37, NFPA 70, NFPA 99, NFPA 110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, 72/23/EEC, 98/37/EC, 2004/108/EC Standby - Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel Rates are based on fuel oil of 35º API (16º C or 60º F) gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional Ratings may be available for specific customer requirements. Consult your Cat representative for details. 5

DIMENSIONS Length Width Height Package Dimensions 4141.6 mm 163.05 in 1823.3 mm 71.78 in 2210.5 mm 87.03 in NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. www.cat-electricpower.com Feature Code: C27DR70 Gen. Arr. Number: 385-0624 Source: U.S. Sourced 2013 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. 6