Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical



Similar documents
The Intelligent AX1 Switchgear for Medium Voltage

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Unified requirements for systems with voltages above 1 kv up to 15 kv

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

2008 Eaton Corporation. All rights reserved.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Extend the Life of Existing Switchgear

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Metal-enclosed single busbar, Solid and Air-Insulated switchgear

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Nothing s BetterThan the Original MODAN Power Distribution Systems

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Advantages of Fixed Circuit Breaker Switchgear

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

Medium Voltage Motor Control Assemblies

Part 1 System Modeling & Studies for Existing Systems

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

UFES Active protection for switchgear

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

The following components are common to most cubicles; this example is an ABB HK cubicle.

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

Electrical Distribution Services for Mining and Metals Industries

Safe and secure distribution of medium voltage with AX1

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

MNS is Switchgear System Technical Overview

Addendum #2 Contract UK-11-13

Increasing safety, reliability and efficiency for today s data centers

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Diesel Engine Driven Generators Page 1 of 6

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Siemens tiastar TM Motor Control Center (MCC) Siemens All rights reserved.

Arc Terminator Active Arc-Resistant Switchgear

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

How To Choose A Transformer

Switchgear and Metal-Enclosed Bus

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

GE Power Controls. MiniFORM Switchboards

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

Metal-enclosed single busbar, Solid and Air-Insulated switchgear

How to reduce exposure to arc flash hazards

Low Voltage Switchboards The Best Technical Solution for Your Ship

What will MV switchgear look like in the future? by Jean-Marc Biasse

know-how Giant in distributing electricity for industry Prisma GK

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

SENTRON Switching and Protection Devices Air Circuit Breakers

Low voltage systems for all applications

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

How To Build A Germany Power Plant

Bypass transfer switch mechanisms

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Sample - No Commercial Use

Chapter 1. Network Structures

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

Communicate and view data from meters with one simple device

Permissible ambient temperature Operation Storage, transport

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

INDOOR MEDIUM VOLTAGE SWITCHGEAR - UP TO 24kV. A division of ACTOM Pty Ltd

Arc Flash Energy Mitigation Techniques

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

MCC Ratings. Voltage Rating

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Primary and Secondary Electrical Distribution Systems

Utility generation line card

Enhancing Personnel Safety with Arc Resistant Equipment

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

IEC & 2 standard. The reference for safe and reliable LV switchboards

Engineering Specification

FAQs-Main switchboard design criteria

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

Safety By Design. Strategies for Electrical Contractors

Eaton s Electrical Services & Systems. Technical Training Safety Training

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Transcription:

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Victor Lee Commercial Marketing Manager SEA Eaton Oil & Gas Solution Tech Day 2013 Eaton. All Rights Reserved.

Eaton is a leading diversified power management company We help the world use electrical, fluid and mechanical power more reliably, efficiently, safely and sustainably.

Electrical Sector overview Solutions for the entire power system IT and data centers Oil & gas, mining, industrial Electric utility Commercial Institutional Government Alternative energy Residential Machinery OEMs Power distribution & circuit protection Backup power protection Lighting & security Control & automation Structural & wiring devices Solutions for harsh & hazardous environments Engineering Services

Safety, Sustainability and Availability: Arc free design SF 6 free Solid insulation Vacuum interrupters System integration Creating Value: Arc flash and network studies Power quality and monitoring solutions Network and application knowledge Total Cost of Ownership

Features & benefits Safe Reliable Maintenance free > 30,000 mechanical operations > 100 short-circuit switching operations x I sc Compact Experience Pioneers in vacuum technology for over 80 years First vacuum interrupter in 1967 * Eaton estimates based on current industry trends

Features & benefits High Mechanical Strength Protects Against Harsh Climatic Conditions Protects Against Mechanical Impact Shock and Vibration High Thermal Conductivity High Electrical Resistivity and Creepage Environmentally Friendly Environment friendly Experience Developments through solid insulation technology in the 1950 s Full encapsulation capability in the 1990 s

Switchgear..with sustainability built Low-environmental impact Fully Air and epoxy-resin insulated Vacuum switching Low end of life disposal costs Fully recyclable SF 6 Free: No use of SF 6 gas in production or operation No leakage of this harmful greenhouse gas No toxic by-products produced No SF6 gas service checks

RELIABILITY, EFFICIENCY, SAFETY and SUSTAINABILITY. Integration into Eaton s Switchgear Solutions Meet requirements for: Improved energy efficiency, Life extendibility, Optimized space, Minimized capital expenditure, Speed of installation, Sustainability Uptime Safety

MV Solutions - Overview Xiria Xiria-E Power Xpert FMX Power Xpert UX MVA AmpGard

LV Solutions - Overview Capitole 40 Power Xpert CX Freedom 2100 MCC Flashgard MCC

Efficiency Solutions Fully-Automated Xiria Voltage & Current Direction Current IEC 60870-5-104 IEC 61850 Eaton RTU 3G/GPRS Modem Functionalities with RTU: Control and status monitoring up to 5 panels Alarming, event recording and data logging Programmable logic according to IEC 61131-3 Communication (Ethernet and Wireless) IEC 61850 compliance Web interface (monitoring) Protection Positioning Types: RTU RTU M Batteries Remote Terminal Unit without modem Remote Terminal Unit with modem

Efficiency Solutions Power Xpert TM FMX Remote operation/earthing VT disconnects Integrated cable test facility Simple cable testing via front panel Eliminates need to remove plug cover Prevents disturbed cable connections Additionally flexibility.. exchange of circuit-breakers

Efficiency Solutions Integrated arc absorber reduces output impact Facilitates switchroom design and simplifies installation Power Xpert TM FMX Xiria-E

Efficiency Solutions Front access MV withdrawable and fixed mounted switchgear solutions Optimised Footprint Power Xpert TM UX Power Xpert TM FMX

Efficiency Solutions Capitole 40 System flexibility Changing of compartment size under live conditions E.g. from a 18.5 kw to a 45 kw motor starter simple removal of the compartment separation plate On-site modification of drawout units and insertion of the 45 kw motor-starter on the already present main isolating scissor contacts.

Reliability Solutions Modern MV Breaker Technology Epoxy encapsulation Greater than 20,000 mechanical endurance Lubrication free mechanism Single tool accessory replacement Time tested SL vacuum contactors insure long life with low maintenance 400A Contactor 1M Electrical Operations 2.5M Mechanical Operations 800A Contactor 250K Electrical Operations 1M Mechanical Operations

Reliability Solutions Eaton is a fully integrated manufacturer World Leading Vacuum Interrupters Protection & Control Epoxy Encapsulation Technology W-VACi Vacuum Circuit Breaker + Universal Mechanism Assembly

Reliability Solutions Power Xpert TM FMX Reliable circuit-breaker with Innovative Electromagnetic Mechanism The features Permanent magnetic actuator Mono-stable principle Low tripping energy Force-stroke characteristics as required by vacuum switch as offered by a conventional spring operated mechanism as offered by an electromagnetic mechanism

Reliability Solutions MVA Metal Clad Switchgear Corona-free by design Corona emissions have been eliminated by special fabrication and assembly techniques, such as rounding of all sharp copper edges, employing star washers for bolting metal barriers and utilising specially crafted standoff insulators for primary bus supports. Insulated Bus All primary bus conductors are insulated with track-resistant fluidized bed epoxy coating.

Reliability Solutions Capitole 40 Main isolating contacts Patented scissor-shaped contact design At insertion of tray, main contact pins create extra contact force at both busbar and tray sides Construction of contact jaws prevents possible welding at busbars Increasing through-going (short-circuit) currents cause increased contact pressure on the vertical busbars and on the tray's contact pins, consequently preventing contact repulsion under short-circuit conditions (Force of attraction on parallel conductors at high through-going currents)

Reliability Solutions On-Line Partial Discharge Monitoring InsulGard the Predictive Monitor Detection of Insulation Degradation before FAILURE!! Easy to use diagnostic system and software. Ability to incorporate Reliability Centered Maintenance System versus Time/Interval Based Maintenance. Elimination of system outages, lost production, safety incidents. 15 channel partial discharge monitor Sensors include: coupling capacitors, radio frequency CT s and motor RTDs Web access through Ethernet port (FTP data file transfer, email on alarm) USB, Modbus, Modbus TCP Predictive Diagnostics for majority of electrical equipment: Rotating Equipment Motors/Generators Switchgear Cables and Bus Duct

Reliability Solutions Life Extension & Reduced Maintenance E-ESS Offerings Aftermarket PCB Class 1 Reconditioning Power System Studies & Audits Arc Flash Studies & Solutions Field Services Offshore Certified Start-Up & Commissioning 24/7 Response Turnkey Projects & PM

Reliability/Safety Solutions Capitole 40 Fault Free Zone Fully insulated main busbar system Insulated branch bars Epoxy resin coated busbars Easy extendable on site Individually insulated busbar sections

Reliability/Safety Solutions Capitole 40 Fault Free Zone Phase-to-phase Segregation (Arc Proof): At cable and busbar side of incoming feeders At left and right of bus couplers

Reliability/Safety Solutions Capitole 40 Fault Free Zone Silver plated vertical busbars Epoxy coated connection bars between main and vertical busbars. Each set of parallel busbars is located in a partitioned section of the glass-fibre reinforced busbar duct. Fault Free: phase to phase and phase to earth faults excluded

Reliability/Safety Solutions Capitole 40 Fault Free Zone Full phase-to-phase segregation at both motor tray and vertical busbar sides. Double sided phase segregation is accomplished before the main contact pins enter the contact cassettes.

Safety Solutions Safe isolation Xiria / Xiria-E Visible Isolation/earthing Changeover switch Vacuum Interrupter position

Safety Solutions Safe isolation Through the door or motorised racking UX/W-VACi FMX MVA Motorised 2-position disconnector

Safety Solutions Safe isolation Remote racking device Accessory to perform RotoTract (FlashGard) racking safely behind NFPA 70E Arc Flash boundaries Remote Power Racking system RPR-2

Safety Solutions Safe isolation Capitole 40 MTP Moving from Disconnected to Test to Connected behind a closed door Meeting IEC TR 61641 criteria 1-7 also when inserting / withdrawing functional unit Physical separation in disconnected position Connected: Main and Auxiliary contacts are connected Test: Auxiliary contacts are connected and Main contacts are disconnected Disconnected: Main and Auxiliary contacts are disconnected Padlock facility Lever can only be moved when door is closed (locked) and isolator is in the OFF-position.

Safety Solutions Arc Fault Mitigation MV Epoxy Insulation SVS W-VACi FMX

Safety Solutions Arc Fault Mitigation Insulated Bus Both the horizontal and vertical buses are insulated Prevents phase to phase fault propagation FlashGard MCC Capitole 40 Fault Free Zone Per previous Labyrinth Vertical Bus

Safety Solutions Personnel Safety Personal safety - Capitole 40 Internal segregation Form 4a in Capitole 40 All connection terminals for external conductors integrated in each separate compartment Incoming and outgoing functional units Terminals for external conductors Safe cable connection Access to cable termination only possible with removed draw-out unit Safe connection of outgoing cables feasible under live conditions

Safety Solutions Shield the Operator Internal Arc Classification (Arc Resistant) Power Xpert FMX Xiria Xiria-E Power Xpert UX Capitole 40

Safety Solutions Shield the Operator Internal Arc Classification (Arc Resistant) Arc Resistant MVA Arc resistant Ampgard

Safety Solutions Reduce Severity Benefits of optional Arcflash Reduction Maintenance System (ARMS) are: Increased personnel safety by limiting the available arc flash energy. Simple to operate. Enabled with the circuit breaker door closed by a door mounted lockable switch Enabled only for the time required to perform the (maintenance) work. Preserves overcurrent coordination under normal conditions. Equipment downstream of a circuit breaker equipped with an ARMS can have a significantly lower incident energy level.

Questions?