SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Similar documents
HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Contents. Document information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Digital input modules

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

CompactLogix Power Supplies Specifications

Cross-beam scanning system to detect slim objects. 100 mm in

Product and functional description

Rosemount 333 HART Tri-Loop

IO-RM3 3-Stage Relay Module

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

DLP-PU/E Instruction Manual

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Rosemount 333 HART Tri-Loop

TX OPEN RS232/485 module

Electronic overload relay EF19 and EF45

Adjustment functions for both span and shift have been incorporated

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ATL Fuel Level Sender Probes

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Power Supplies 3. SDN-P DIN Rail Series

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Electronic overload relay EF65, EF96 and EF146

Model: DC-A2IO Advanced HVAC Controller

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

MINI MCR-SL-R-UI(-SP)

Problem / Solution. The problem:

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

3-phase, bidirectional energy meter

NX safety stand-alone

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Solid-State Timer H3G

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Vario-Series Accessories

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

38 Series - Relay interface modules A

Energy Management Energy Meter Type EM23 DIN

WD-AMX Water Detection Controllers

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MCR1900 Media Converter 19-Slot Chassis

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

R.C.C.B. s two-pole LEXIC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

E-STOP relays, safety gate monitors

J TB/TW Temperature limiter, temperature monitor

Analog signal converters CC-E I/I Current / current isolators

DS 600. A contact free flux gate based current measurement sensor 600A rms

SYSTEM 4C. C R H Electronics Design

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Duct Humidity Transmitter

Three-phase monitoring relay CM-PFE

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Contact expansion modules

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Power Meter Series 700

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Contact expander modules

Safety technique. Emergency stop module BO 5988 safemaster

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

49 Series - Relay interface modules A. Features

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Fast, reliable, ultra-precise. My-Com precision switches.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Digital Pressure Measuring Instrument MDR480

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Redundancy Module QUINT-DIODE/40

Laserlyte-Flex Alignment System

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

DCP Fan Controller. Version 01/2009. The engineer s choice

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

RM4TG20 three-phase network control relay RM4-T - range V

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Transcription:

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting from errors or omissions, and reserve the right of amendment without notice. This document may not be reproduced in any way without the prior written permission of the company. March 2007 IIG-070501 Page 1

CONTENTS 1. INTRODUCTION 3 1.1 Hardware Features 3 1.2 Isolation Details 3 2. UNPACKING 3 3. QUICK START GUIDE 4 4. CONNECTIONS 5 5. CONFIGURING THE SLIMCON 6 5.1 Input and Output Selection 7 6. CALIBRATING THE SLIMCON 8 7. INSTALLATION 9 7.1 Troubleshooting 9 8. SPECIFICATIONS (@ 25 C) 10 IMO Precision Controls Ltd Page 2 IIG-070501

1. INTRODUCTION 1.1 Hardware Features The SLIMCON-6 family of Isolating Signal Converters can accept a range of inputs including 4-20mA and voltage signals. The unit produces high level DC output of either voltage or current. The input and output of the unit can be reconfigured using the built in switches together with the zero and span adjustment potentiometers. The unit can be powered by any DC voltage between 18 and 30Vdc (22V at least required to drive into 500 ohms). The instrument is packaged in an ultra slim 7.5mm wide enclosure which can be mounted on standard TS35 DIN-rail. 1.2 Isolation Details The SLIMCON has full 3 port isolation of 1000V between the Input Stage, Output Stage and Power Supply for functional reasons. 2. UNPACKING The instrument should be carefully inspected for signs of damage which may have occurred in transit. In the unlikely case that damage has been sustained, DO NOT use the instrument, but please retain all packaging for our inspection and contact your supplier immediately. The instrument comes with the following items as standard: 1 SLIMCON-6 Isolating Signal Converter 1 SLIMCON-6 User Guide If the instrument has been factory configured the input and output details will be listed on the Serial number label on the side of the unit. If re-configuration is required please refer to section 5 of this manual. IIG-070501 Page 3

3. QUICK START GUIDE This example shows how easy it is to configure a SLIMCON-6 with 4-20mA Input, 0-10V Output!! WARNING! DO NOT ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Set up the switches to the required type and range (see page 7) using the blade edge of a small flat screwdriver (or similar small pointy implement). E.G. For 4-20mA Input, 0-10V Output, S1: 1,2,3 are on S2: 2,3,4,6 are on Connect up the inputs, output and power supply and switch on (page 5) Apply full scale input value (20mA) Adjust span pot to required output value 10V Apply zero scale input (4mA) Adjust zero pot to required output value 0V Repeat the 4 previous steps until the output is correctly calibrated. Page 4 IIG-070501

4. CONNECTIONS The SLIMCON-6 is housed in a compact DIN rail mounting enclosure, with 8 terminals, 4 on top and 4 underneath. The diagram below shows how to connect the different input, output and power supply types. NC 8 10 12 OUTPUT 8 Current Sink -ve 12 +ve 0-10V 0(4)-20mA 10 - ve Voltage Source Current Source Current Sink 4-20mA Sink + 24V Supply Span Adjust Zero Adjust 5 4 INPUT 5 +ve Input: ma, Volts 4 - ve 2 1 POWER 2 18-30Vdc 1 0V IIG-070501 Page 5

5. CONFIGURING THE SLIMCON!! WARNING! DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED The SLIMCON can support Voltage and ma inputs. The unit is configured by turning the power off, selecting the switch settings required on the side of the unit and turning the power back on. The switches are accessed through two cut-outs in the side of the enclosure. There are 2 switch banks, S1 and S2: ON 4 5 6 OFF Switch S2 1 6 Switch 4 is OFF Switch 5 is ON Switch 6 is OFF Switch S1 1 4 Switch S1 configures the input type and range and switch S2 configures the output type and range. The switch settings are explained on the next page. Page 6 IIG-070501

5.1 Input and Output Selection Select the input and output ranges from the table below and set Switches S1 and S2 to the required values. S1 SWITCH S2 SWITCH IN OUT 1 2 3 4 1 2 3 4 5 6 4-20mA 4-20mA 1 1 1 1 4-20mA 0-20mA 1 1 1 1 1 1 4-20mA 0-10V 1 1 1 1 1 1 1 4-20mA 0-5V 1 1 1 1 1 1 1 1 0-20mA 4-20mA 1 1 1 1 0-20mA 0-20mA 1 1 1 1 0-20mA 0-10V 1 1 1 1 1 0-20mA 0-5V 1 1 1 1 1 1 0-10V 4-20mA 1 1 0-10V 0-20mA 1 1 0-10V 0-10V 1 1 1 0-10V 0-5V 1 1 1 1 0-5V 4-20mA 1 0-5V 0-20mA 1 0-5V 0-10V 1 1 0-5V 0-5V 1 1 1 0-10mA 4-20mA 1 1 1 0-10mA 0-20mA 1 1 1 0-10mA 0-10V 1 1 1 1 0-10mA 0-5V 1 1 1 1 1 1 = SWITCH ON!! WARNING! DO NOT ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED IIG-070501 Page 7

6. CALIBRATING THE SLIMCON When the unit is shipped the SLIMCON will be calibrated for the input and output types and ranges noted on the side label. If this label is blank then the unit will be calibrated for 4-20mA input and 4-20mA source output. The span and zero points are adjusted using the potentiometers accessible on the front panel. Apply full scale input value Adjust span pot to required output value Apply zero scale input Adjust zero pot to required output value Repeat the four previous steps until the output is correctly calibrated. Page 8 IIG-070501

7. INSTALLATION The SLIMCON s input and output circuits are classed as Separated Extra Low Voltage (SELV). This means that they must not be externally connected to voltages exceeding 30V ac or 60V dc, nor do they generate voltages above these limits internally. Where a higher voltage input is required a specially designed DIVIDER unit can be used to condition the input signal prior to connection to the process input terminals. The SLIMCON unit clips directly onto Top Hat (TS35) symmetrical DIN rail. Ideally, mounting orientation should be vertical. Good airflow around the unit will maximise reliability of the instrument. The use of bootlace ferrules is recommended on wiring terminations. Do not exceed terminal torque rating of 0.4 Nm use an appropriate screwdriver. The unit can be removed from the DIN rail by sliding a small screwdriver into the slot at the rear of the enclosure on the lower face and gently levering the metal clip, whilst lifting the unit from the rail. 7.1 Troubleshooting Check that the switch settings are correct. Check that sensor wiring is correct. Check that applied voltage is not out of range. Check that applied current is not out of range. IIG-070501 Page 9

8. SPECIFICATIONS (@ 25 C) Operating Temperature 0 to 55 C Power Requirements DC Supply 18 to 30Vdc (22Vdc required to drive 500Ω) Current Consumption 25mA @ 24Vdc into 500Ω Volt Drop (ma input) 0.1V (max 0.15V at 20mA input) Calibration accuracy ±0.05% full scale Output Linearity ±0.03% full scale (max 0.1%) Temperature Stability ±100ppm / C Load Resistance Error ±5ppm/ohm (load between 0 and 500Ω) Time Constant (10-90%) Input Impedance: Current Input Typical Current Input Max Voltage Input 25mS (max 30mS) 5 Ω (typical 20mA range) 10 Ω (max on 0-10mA range) 500k Operating Altitude Humidity Sea Level to 2000m 0-90% RH Unit has full 3 port Isolation to 1kV between Power Supply, Input and Output. The unit can also withstand transients of 2.5kV for 50 µsecs. Dimensions 93.1mm x 102.5mm x 6.2mm (H x D x W) Mounting DIN Rail TS35 Connections Screw Clamp with pressure plate Conductor Size 0.5 to 4.0 mm Insulation Stripping 12 mm Maximum Terminal Torque 0.4 Nm Weight Approx. 140g EMC BS EN61326 LVD Standards EN61010-1 Installation Category (IEC 664) II Pollution Degree (EN61010-1) 2 Equipment Class (IEC 536) II Page 10 IIG-070501