Digital Thermometer Instruction manual

Similar documents
Thermistor Thermometer MODEL NO

Hygro-Thermometer + InfraRed Thermometer Model RH101

Instruction Manual Temp 4/5/6 Temperature Meter Series

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Milwaukee USER MANUAL

Thermocouple Thermometer Models

Manual Ranging MultiMeter

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

Mold Alert... Operation Manual P0270

OPERATING INSTRUCTIONS

COLOR VIDEO DOOR PHONE CDV-71BE/D

Owner s Manual

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

digital fever alert ear thermometer suitable from birth instruction manual

User Manual. Video Doorphone CDV-1020AQ

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

How To Use A Meter

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

FT-100 Fire Training Fog Machine User Manual English

UT202A Operating Manual. Contents

Microwave Meter. Instruction Manual

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

AutoRanging Digital MultiMeter

24 Wide Screen LED Monitor with HDMI

Ground Resistance Clamp On Tester

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

February Xerox 8265/8290 Color Wide Format Printer User Maintenance and Cleaning Guide

High Temperature InfraRed Thermometer with Laser Pointer

7-SEGMENT DIGITAL CLOCK

TABLE OF CONTENTS 11.0 WARRANTY

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

Use and Care Manual. Model CPA12KH AIR CONDITIONER

User Guide. 4 wire Earth Resistance Tester Model GRT300

User Guide Reflow Toaster Oven Controller

LCD BacPac. User Manual + Warranty Info

NFC Communication Tray Model: HHX-IT3-Z

Light Meter (Foot Candles)

How To Use A Power Supply From A Powerstation

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Model UT713 OPERATING MANUAL

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

USER S MANUAL HSC-24A

Digital Photo Picture Frame. Operation Manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Model UT33A: OPERATING MANUAL Table of Contents (1)

7 FUNCTION DIGITAL MULTIMETER

Ground Resistance Clamp-On Tester

Dual Laser InfraRed (IR) Thermometer with Color Alert

RS DIGITAL THERMOMETER

CELO5. User & Installation Manual.

Dual Laser InfraRed (IR) Thermometer

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

SINGLE RANGE DS METERS Operation Instructions

Spec. No. ICR C Version No. 0.0

Mini InfraRed Thermometer with Laser Pointer

ExStik TM ph Waterproof Meters

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

el-720 Carbon Dioxide Gas Leak Detector User s Guide

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

INSTRUCTIONS FOR ANALOGUE QUARTZ AND MECHANICAL WATCHES

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

QUICK REFERENCE. Wired remote controller BRC2E52C7 BRC3E52C7

Instant Ear Thermometer

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Model: Manual DC: WIRELESS COLOR FORECAST STATION

3mm Photodiode,T-1 PD204-6C/L3

User Manual Color video door phone

Dehumidifier Users manual. For Models: DH45S DH65S

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

DSM155 Digital LED Light Meter User s Manual DSM155

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Phoenix Body Fat Scale Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Quick Reference Guide

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

IN-OUT Thermometer with Cable Free Sensor and Clock

Instruction Manual HI Refractometer for Sucrose Measurements

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

Global Water Instrumentation, Inc.

User's Guide. Pinless Moisture Meter. Model MO257

HVAC Clamp Meter. Users Manual

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

Wi-Fi Remote. User Manual

12 Volt 30 Amp Digital Solar Charge Controller

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Model UT201/202: OPERATING MANUAL. Table of Contents

DUAL ELECTRONIC DICE K3400

BUNK BED. Model No.: DA3797E - Espresso DA3797P- Pine. UPC CODE: (Espresso) (Pine) NOTE: Lot number: Date of purchase:

=============================== WARNING

Specification Approval Sheet

Transcription:

MCA-900Ⅱ Digital Thermometer Instruction manual Preparation in September 2006 The 1 st edition JAPAN BONKOTE CO., LTD. R

Contents 1. Preface 2 2. Notes for safety 2 3. Specification of MCA-900II 3 (A) Name and Function of each part (B) General Specification (C) Explanation of Display and Indication 4. How to use MCA-900II 4 (A)-1 How to use iron tip sensor unit (SAT-1) (A)-2 Replacement of iron tip sensor (SC-006) (A)-3 How to measure iron tip temperature (B) How to use sensor for Dipping (SC-007) (C) How to use sensor for Surface (SC-008) 5. Explanation of the function and the operation of MCA-900II 6 (A) Data hold function (B) MAX hold function (C) Selecting resolution function (D) Selecting unit of temperature indication function 6. Replacement of battery 7 7. Calibration of MCA-900II 7 8. Guarantee and After Sales Service 7 (A) Guarantee (B) After sales service 1

1. Preface Thank you very much for purchasing Digital thermometer MCA-900II. For using this machine properly, please read through this instruction manual before use. Also, safekeeping this instruction manual after read. 2. Notes for safety Notes for safety should be followed completely for using this machine safely. Caution To avoid electrical shock, do not use this thermometer to measure temperature of the parts on a circuit, and etc.,. To avoid damage or fire, do not use this thermometer for measurement in microwave ovens, or microwave hearth. -------------------------- Notes -------------------------- Using this machine near heating equipments, battery consumption will be faster than using it with normal temperature, also it will have cause of damage and plastic melting of the body part. Refrain from the place where would be direct sunshine for Display. Considering condensation, be careful to use this machine in environment that has rapid temperature change. Working environment for this machine is 0~40, and under 80%RH. -------------------- Sensor -------------------- Important Optional thermo couple sensor (K type) is necessity for measurement. ------------------- Maintenance ------------------- Warning For removing stain on the body, use dries soften cloth or the cloth which is squeezed completely after soaked in neutral detergent. Do not use cloth that has much moisture. Using volatile solvent like alcohol, thinner and benzine is prohibited. 2

3. Specifications of MCA-900II (A) Name and Function of each part 1 Display 2 POWER button: Turning Power supply ON/OFF 3 HOLD button: Holding measured value 4 MAX button: Holding highest measured value 5 0.1 /1 button: Selecting a resolution of indication 6 button: Selecting indication unit ( ) 7 F button: Selecting indication unit ( F) 8 Soft case (B) General Specification Resolution 0.1 (0~199.9 )/1 (Whole measurement range) Measurement range 0~1000 Sensor Thermo couple K Measurement accuracy ±(0.3%rdg+2 )(23 ±5 Body only) Display 3.5 Digit LCD Display Power DC9V (Battery 006P 1Pcs) Battery life 250hrs (At continuous use of Brand new alkaline battery) Working environment 0~40 Under 80%RH Dimension 80W X 48D X 156H mm (including Soft case) Weight 305g (Including battery) (C) Explanation of Display indication 3 Temperature Display Indication in Celsius( ) Indication in Fahrenheit( F) Holding measured value Holding highest measured value Indication of battery replacement necessity Un-indicatable

4. How to use MCA-900II (A)-1 How to use iron tip sensor unit (SAT-1) 1Connect the iron tip sensor Unit SAT-1 to MCA-900II after confirmation of the polarity. 2Turn on power switch, temperature is indicated at Display. It is ON mode. (Display indicates near room temperature.) 3Preparation is done. Measurement mode is ready. (A)-2 Replacement of iron tip sensor (SC-006) Impurities of solder dust and flux will be stained to iron tip sensor (SC-006). Keep SC-006 clean, otherwise temperature will be indicated lower than real temperature due to worse condition of SC-006. Replacement standard is about 300 times measurement. (It is depends on each condition.) Replacement method is Pull it out and Insert it in. Please make sure to put into correct pole. Red color paint is + pole. 5pcs in a set for purchase (A)-3 How to measure iron tip temperature 1 Put small amount of solder onto iron tip to measure. Amount of solder should be regular, not a lot, not a bit. 2Put iron tip onto center of sensor. Make sure that the place-attaching sensor and iron tip is fixed. 3For Re-measurement, follow the above order after the indication became near room temperature. Otherwise, sensor is continuously heated, and then temperature is not stable. 4Attaching time is about 3 seconds that it needs time for conduction of heat thru solder. It the time is too long, it does not show correct temperature as sensor is keep-absorbing heat. 4

(B) How to use Sensor for dipping (SC-007) Measurement range Room temperature~+800 1 Connect sensor for dipping to MCA-900II. (Make sure correct electrode pole.) 2 Turn on power switch, temperature is indicated at display, It is ON mode. (Display indicates near room temperature.) 3 Preparation is done, Measurement mode in ready. (C) How to use Sensor for surface Measurement range Room temperature~+800 1 Connect sensor for surface to MCA-900II. (Make sure correct electrode pole.) 2 Turn on power switch, temperature is indicated at display, It is ON mode. (Display indicates near room temperature.) 3 Preparation is done, Measurement mode in ready. 5

5. Explanation of the function and the operation of MCA-900II (A) DATA HOLD function 1 Push HOLD key, 2 Push HOLD key again, is turned on and indicated value is hold. is turned off and release the hold. (B) MAX HOLD function 1 Push MAX key, undated and hold. 2 Push MAX key, is turned on and highest measured value is is turned off and release the hold. (C) Selecting resolution function 1 Push 0.1 /1 key to select resolution at display 0.1 /1. Indication range of 0.1 resolution is 0~199.9, the value other than it indicates. For soldering work, refrain from 0.1 resolution use. (D) Selecting unit of temperature indication function 1 Push key, indication will be in (Celsius). 2 Push F key, indication will be in F(Fahrenheit). 6

6. Replacement of battery When battery is consumed, will be indicated at display. Please replace to a new battery (006P:9V) with following direction. With less battery, measurement accuracy will be lower. 1 Take main body out from soft case. 2 Raise the stand for lengthwise. 3 Remove screws (3pcs) for assembly by a cross-head screwdriver. 4 Take out operation part from bottom case. Make sure not to touch other parts. 5 Replace to new battery (Make sure correct electrode pole) 6 Assemble with opposite order. 7. Calibration Optional calibration service with consideration is available, and it is recommendable to implement calibration one a year. Calibration certification, Calibration test reports, Traceability sheet will be issued for the calibration. If you have Calibration requests service, please contact your dealer or us. 8. Guarantee and After service (A) Guarantee Our products are shipped after several factory tests & inspections. But if you find malfunction or defects due to problems in workmanship or transportation, please contact with your dealer or us. The guarantee period of your system is one year after your purchase, except for replacement parts. (B) After service When you think your system does not work properly, read this manual again to check. If still troubles are not solved, please contact your dealer or us. JAPAN BONKOTE CO., LTD. 600-14 Kasahara-Cho, Mito-City, Ibaraki-Pref, JAPAN Postal code: 310-0852 TEL +81 29-241-2725 FAX +81 29-241-2726 URL http://bonkote.co.jp E-mail:info@bonkote.co.jp 7