SimplyBlue SafeStain. For fast, sensitive, and safe Coomassie G-250 staining of proteins USER GUIDE. Catalog numbers LC6060, LC6065

Similar documents
Path-ID Multiplex One-Step RT-PCR Kit

NIH Mammalian Gene Collection (MGC)

One Shot TOP10 Competent Cells

Pure-IP Western Blot Detection Kit

Fluorescein Isothiocyanate (FITC)- conjugated Antibodies

UltraClean PCR Clean-Up Kit

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Applied Biosystems 7500/7500 Fast Real-Time PCR Systems. SUBJECT: Memory Upgrade Requirements for 7500 Software v2.0

UltraClean Soil DNA Isolation Kit

NuPAGE Technical Guide

SDS-PAGE. (June 23, 2005)

Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western).

2. Cut 6 sheets of Whatman 3MM paper and 1 sheet of blotting membrane to the size of the gel, or slightly smaller.

Western Blotting: Mini-gels

WESTERN BLOT DETECTION KIT Buffers and detection reagents for up to ten 10 x 10 cm 2 blots. Fluorescent detection via: Goat anti-mouse SureLight P3

CytoSelect 48-Well Cell Adhesion Assay (ECM Array, Fluorometric Format)

An In-Gel Digestion Protocol

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

ProteoMiner Protein Enrichment Kits

TIANquick Mini Purification Kit

Security, Audit, and e-signature Administrator Console v1.2.x

Western Blotting. Prepare samples:

Material Safety Data Sheet Precast Agarose Gel Cassettes for the SageELF TM DNA Fractionation Instrument

OpenArray Sample Tracker Software

EZ-Run Protein Gel Solution. EZ-Run Protein Standards. EZ-Run Gel Staining Solution. Traditional SDS-Page Reagents. Protein Electrophoresis

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

Laboratory Hazardous Waste Disposal Guidelines

Product name Company Cat # PowerPac Basic Power supply Bio Rad Mini Protean electrophoresis system Mini trans blot cell Bio Rad

EZ-PAGE Electrophoresis System USER MANUAL

Annexin V Conjugates for Apoptosis Detection

Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus

Goat Anti Mouse IgG Antibodies

SYBR Safe DNA Gel Stain

NimbleGen DNA Methylation Microarrays and Services

Taq98 Hot Start 2X Master Mix

Goat Anti Rabbit IgG Antibodies

Western Blot Protocol (updated on 05/20/14)

CompleteⅡ 1st strand cdna Synthesis Kit

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

PowerFecal DNA Isolation Kit

Compromise Elsewhere Protocols. Western Blotting Methods ROCK 1 of 11

Applied Biosystems 3500/3500xL Genetic Analyzer

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

PicoMaxx High Fidelity PCR System

Running protein gels and detection of proteins

WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE

CORE TECHNOLOGIES CONSULTING, LLC SOFTWARE UNLIMITED ENTERPRISE LICENSE AGREEMENT

Section XIII: Protein Separation in Agarose Gels

LITHIUM CARBONATE, 1% AQUEOUS

Rapid GST Inclusion Body Solubilization and Renaturation Kit

Accelerated Electrophoresis with Faster Run Times and Increased Sample Throughput

Thermo Fisher Cloud HELP. Catalog Number A Publication Number MAN Revision C.0

ELECTRONIC ARTS SOFTWARE END USER LICENSE AGREEMENT

Malachite Green Phosphate Assay Kit

Agarose Gel Electrophoresis with Food Color- Teacher Guide

Western Blot Analysis

Troubleshooting Guide for DNA Electrophoresis

Electrophoresis Guide

PerfectFOCUS. For Preparing Low Conductivity Samples for IEF/2D-Gel Electrophoresis. (Cat. # , T)

Technical Manual No Update date

Protein expression in the life cycle of bean beetles (Callosobruchus maculatus)

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Western Blotting. USA: UK & Europe: europe@ptglab.com China: service@ptglab.com.

Mayfair EULA for Journal Office

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE

SDS-PAGE Protocol Mutated from the SDS-PAGE protocol written by the Lord of the Flies

Plant Genomic DNA Extraction using CTAB

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

METHOD USED TO EXTRACT TOTAL MUSCLE PROTEIN FOR WESTERN BLOT USING TRIS-EDTA BUFFER*

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

SenTix 950 SenTix 980

Two-Dimensional Gel Electrophoresis (2-DGE)

PrepTip. Reverse Phase PrepTip User Guide

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

Southern Blot Analysis (from Baker lab, university of Florida)

ECL Western Blotting Substrate INSTRUCTIONS FOR USE OF PRODUCTS W1001 AND W1015.

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

CITRIX SYSTEMS, INC. SOFTWARE LICENSE AGREEMENT

XANGATI END USER SOFTWARE LICENSE TERMS AND CONDITIONS

EmoeHost agrees to provide to Client the Services agreed upon between EmoeHost and Client as selected by Client at

THERMA-KOOL REUSABLE COLD/HOT GEL THERAPY PACK 07/30/14

2D gel Protocol. 2. Determining Protein Concentration of cell lysates

BioResearch. RAFT 3D Cell Culture Kit Protocol

Procedure for RNA isolation from human muscle or fat

Material Safety Data Sheet

Detailed protocol: Combined method for RNA isolation. from cartilage

SDS-PAGE and Western Blotting with the Odyssey Infrared Imaging System Entered by Kevin Janes Janes Lab Protocols 12/9/14

TERMS AND CONDITIONS

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Fast Semi-Dry Transfer System with Yrdimes

Electrophoresis and Electroblotting of Proteins

Radius 24-Well Cell Migration Assay (Laminin Coated)

AGREEMENT BETWEEN USER AND International Network of Spinal Cord Injury Nurses

Methionine Sulfoxide Immunoblotting Kit

STANDARD OPERATING PROCEDURE

Hazardous Waste Generator Training

Agilent High Sensitivity DNA Kit Guide

EdU Flow Cytometry Kit. User Manual

Transcription:

USER GUIDE SimplyBlue SafeStain For fast, sensitive, and safe Coomassie G-250 staining of proteins Catalog numbers LC6060, LC6065 Revision date 13 February 2012 Publication Part number IM-6050 MAN0000735 For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use.

Contents Kit Contents and Storage... 4 Introduction... 5 Overview... 5 Methods... 6 Using SimplyBlue SafeStain... 6 Appendix... 10 Technical Support... 10 Purchaser Notification... 11 Safety Information... 12 3

Kit Contents and Storage Contents and Storage SimplyBlue SafeStain is available in 2 sizes: 1 L (Cat. no. LC6060) Sufficient stain is provided in 1 L to stain 50 mini-gels 3.5 L with a pump dispenser (Cat. no. LC6065) Upon receipt, store SimplyBlue SafeStain at room temperature, 15 C to 30 C. Be sure to keep the bottle capped when not in use. The stain is stable for 6 months when stored at room temperature. Product Use For research use only. Not intended for any animal or human therapeutic or diagnostic use. 4

Introduction Overview Product Description SimplyBlue SafeStain is a ready-to-use, proprietary Coomassie G-250 stain that is specially formulated for fast, sensitive detection and safe, non-hazardous disposal. This stain does not require the use of methanol or acetic acid which must be disposed of as hazardous waste. SimplyBlue SafeStain has been tested for environmental hazards (see page 12). Proteins stained using the SimplyBlue SafeStain are compatible with mass spectrometry (MS) analysis. 5

Methods Using SimplyBlue SafeStain Important An alcohol/acetic acid fixing step prior to staining with SimplyBlue SafeStain is NOT required or recommended. Basic Protocol For general use with 1.0-mm and 1.5-mm Tris-Glycine gels, 1.0-mm NuPAGE Novex Gels, and 1.0 mm Tricine mini-gels (8 8 cm). To achieve maximum sensitivity, refer to the protocol on page 7. After electrophoresis follow the instructions below. Be sure the gel moves freely in water or stain to facilitate diffusion during all steps. Note: For large format gels, see page 4 for recommended volumes of water and stain. 1. Rinse the mini-gel 3 times for 5 minutes with 100 ml deionized water to remove SDS and buffer salts, which interfere with binding of the dye to the protein. Discard each rinse. 2. Stain the mini-gel with enough SimplyBlue SafeStain (~20 ml) to cover the gel. Stain for 1 hour at room temperature with gentle shaking. Bands begin to develop within minutes. After incubation, discard the stain. The stain cannot be re-used. Note: The gel can be stained for up to 3 hours, but after 3 hours, sensitivity decreases. If you need to leave the gel overnight in the stain, add 2 ml of 20% NaCl (w/v) in water for every 20 ml of stain. This procedure will not affect sensitivity. 3. Wash the mini-gel with 100 ml of water for 1 3 hours. The gel can be left in the water for several days without loss of sensitivity. There is a small amount of dye in the water that is in equilibrium with the dye bound to the protein, so proteins remain blue. 4. To obtain the clearest background for photography, perform a second 1 hour wash with 100 ml water. Note: Sensitivity will now decrease if the gel is allowed to stay in the water for more than 1 day. Decrease in the amount of free dye in water favors dissociation of the dye from the protein. If you need to store the gel in water for a few days, add 20 ml of 20% NaCl. Continued on next page 6

Using SimplyBlue SafeStain, Continued Maximum Sensitivity To achieve maximum sensitivity, follow the procedure below. Adding salt results in significant improvement in sensitivity. Values are given for 1.0 mm gels. For 1.5 mm mini-gels, use the value in parentheses. Important: Sensitivity is primarily a function of the dyeprotein interaction, which is unique for each protein. 1. Prepare a 20% NaCl (w/v) solution in deionized water. You need 20 (30) ml per gel. 2. Perform steps 1 and 2, page 6. 3. After staining the gel, wash the gel with 100 (150) ml of water for 1 hour. 4. Add 20 (30) ml 20% NaCl to the water in step 3 of this procedure and continue to wash for an additional 2 hours or overnight (if desired). Large Format Gels For large format gels, increase the volume of water for each rinse and wash step, and the volume of stain to achieve optimal results. Refer to the following table to determine the volume of water or stain required and follow the Basic Protocol for staining. Gel Size Water Stain 15 15 cm, 1 mm 300 ml 60 ml 15 15 cm, 1.5 mm 500 ml 100 ml 20 20 cm, 1 mm 600 ml 120 ml Continued on next page 7

Using SimplyBlue SafeStain, Continued Other Applications Information for staining IEF Gels, 1.5 mm NuPAGE Novex Gels, and polyvinylidine difluoride (PVDF) membranes is provided in the following table. Follow the Basic Protocol (page 2) using the indicated changes. Note: Staining nitrocellulose and wet PVDF membranes results in high background and is not recommended. Stain the Zymogram gel with SimplyBlue SafeStain after renaturing and developing the gel for enzyme activity. Gel or Membrane IEF Gels 1.5 mm NuPAGE Gels Dry PVDF Membrane Zymogram Gels Fix Rinse Stain Wash 100 ml 12% TCA for 15 minutes N/A Basic Protocol, step 1 150 ml water 2 5 minutes 1 10 minutes 100 ml stain for 1 hour Basic Protocol, step 2 N/A N/A 10 20 ml stain for 1 2 minutes* N/A Basic Protocol, step 1 100 ml stain for 1 hour Basic Protocol, step 3 Basic Protocol, step 3 10 20 ml water 3 1 minute Basic Protocol, step 3 *Incubating dry PVDF membranes in stain for >2 minutes results in high background. Continued on next page 8

Using SimplyBlue SafeStain, Continued Microwave Procedure The microwave procedure is fast, takes just 12 minutes, and yields results with sensitivity as low as 5 ng with an additional incubation with a salt solution. The procedure is for 1.0 mm mini-gels. For 1.5 mm mini-gels, use the values in parentheses. Caution: Use caution while using the stain in a microwave oven. Do not overheat the staining solutions. 1. After electrophoresis, place the gel in 100 ml of ultrapure water in a loosely covered container and microwave on High (950 to 1,100 watts) for 1 minute until the solution almost boils. 2. Shake the gel on an orbital shaker for 1 minute (2 minutes). Discard the water. 3. Repeat steps 1 and 2 of this procedure 2 more times. 4. After the last wash, add 20 ml (30 ml) of SimplyBlue SafeStain and microwave on High for 45 seconds to 1 minute (1.5 minutes) until the solution almost boils. 5. Shake the gel on an orbital shaker for 5 minutes (10 minutes). Detection limit: 20 ng BSA. 6. Wash the gel in 100 ml of ultrapure water for 10 minutes on a shaker. Detection limit: 10 ng BSA. 7. Add 20 ml of 20% NaCl for at least 5 minutes. Detection limit: 5 ng BSA. The gel can be stored for several weeks in the salt solution. Dry the Gel Incubating any Coomassie-stained gel in an alcohol solution will eventually result in destaining of the bands. If you use the Gel-Dry Drying Solution from Life Technologies, incubate the gel in the solution for 5 minutes or less. Destain Protein Bands for MS Analysis Use the following general guidelines for destaining the protein bands prior to MS analysis. Contact your MS facility or the protein core facility for detailed protocols. Excise the protein band of interest from the gel using a clean scalpel and destain with 10 30% ethanol or 20 30% acetonitrile for 10 15 minutes or until clear. Rinse the gel piece in ultrapure water and proceed for MS analysis. 9

Technical Support Appendix Obtaining support For the latest services and support information for all locations, go to www.lifetechnologies.com/support. At the website, you can: Access worldwide telephone and fax numbers to contact Technical Support and Sales facilities Search through frequently asked questions (FAQs) Submit a question directly to Technical Support (techsupport@lifetech.com) Search for user documents, Safety Data Sheets (SDSs), vector maps and sequences, application notes, formulations, handbooks, certificates of analysis, citations, and other product support documents Obtain information about customer training Download software updates and patches Safety Data Sheets (SDS) Safety Data Sheets (SDSs) are available at www.lifetechnologies.com/support. Certificate of Analysis The Certificate of Analysis provides detailed quality control and product qualification information for each product. Certificates of Analysis are available on our website. Go to www.lifetechnologies.com/support and search for the Certificate of Analysis by product lot number, which is printed on the box. Limited Product Warranty Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life Technologies General Terms and Conditions of Sale found on Life Technologies website at www.lifetechnologies.com/termsandconditions. If you have any questions, please contact Life Technologies at www.lifetechnologies.com/support. 10

Purchaser Notification Limited Use Label License: Research Use Only The purchase of this product conveys to the purchaser the limited, non-transferable right to use the purchased amount of the product only to perform internal research for the sole benefit of the purchaser. No right to resell this product or any of its components is conveyed expressly, by implication, or by estoppel. This product is for internal research purposes only and is not for use in commercial services of any kind, including, without limitation, reporting the results of purchaser s activities for a fee or other form of consideration. For information on obtaining additional rights, please contact outlicensing@lifetech.com or Out Licensing, Life Technologies, 5791 Van Allen Way, Carlsbad, California 92008. 11

Safety Information Environmental Testing SimplyBlue SafeStain has been tested by an independent and certified laboratory for environmental hazards. The results are summarized in the following table: Analysis Method Results Ignitability EPA 1010 Non-flammable (>144 F) Corrosivity EPA 150.1 Non-corrosive (ph >2.1) Corrosivity (by Corrositex ) DOT-E 10904 Non-corrosive Reactivity (Cyanide and Sulfide) EPA 9010B/9014 No Reactivity Detected EPA 9030A Aquatic Toxicity (fathead minnow; definitive, CAC, Title 22) CA Fish and Game Non-toxic Disposal Information For disposal requirements in your area, consult your local environmental safety officer or regional waste water authority to determine ph levels that can be discharged into the sink. SDS Requests Safety Data Sheets are available at www.lifetechnologies.com/support. 2012 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. Corrositex is a registered trademark of InVitro International. LIFE TECHNOLOGIES CORPORATION AND/OR ITS AFFILIATE(S) DISCLAIM ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON- INFRINGEMENT. TO THE EXTENT ALLOWED BY LAW, IN NO EVENT SHALL LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF. 12

Notes 13

Notes 14

Headquarters 5791 Van Allen Way Carlsbad, CA 92008 USA Phone +1 760 603 7200 Toll Free in USA 800 955 6288 For support visit www.invitrogen.com/support or email techsupport@invitrogen.com www.lifetechnologies.com