Medical Gas Data Sheet (MGDS) Medical air



Similar documents
Medical Gas Data Sheet (MGDS) 5% carbon dioxide/air medical gas mixture

Summary of Product Characteristics Medical Air

Medical Gas Data Sheet (MGDS) 9% helium/35% oxygen/nitrogen medical gas mixture

Medical Gas Data Sheet (MGDS) 9% helium/35% oxygen/ nitrogen medical gas mixture

Summary of Product Characteristics Medical Helium

Compressed medical oxygen.

Medical Gas Data Sheet (MGDS) ENTONOX. Essential safety information.

This leaflet provides information on

* * * EMERGENCY OVERVIEW * * * High pressure gas. Can cause rapid suffocation. Can increase respiration and heart rate.

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Take care with oxygen Fire and explosion hazards in the use of oxygen

MATERIAL SAFETY DATA SHEET

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

Material Safety Data Sheet

Material Safety Data Sheet

COMMITTEE ON HERBAL MEDICINAL PRODUCTS (HMPC) FINAL COMMUNITY HERBAL MONOGRAPH ON AVENA SATIVA L., FRUCTUS

MATERIAL SAFETY DATA SHEET - Air-Compressed

Technical Data Sheet

Medical gas cylinder data chart. BOC: Living healthcare

Hypromellose Eye Drops BP 0.3% w/v PL 23097/0006

Certain specific properties of compressed gases make them highly useful in various research activities.

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET Argon, compressed. SECTION 1: Identification of the substance/mixture and of the company/undertaking

MATERIAL SAFETY DATA SHEET

Compressed Gas Cylinder Safety

Compressed Gas Cylinder Program

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Methane in Air % to 2.5%

Product Bulletin INTEROX HYDROGEN PEROXIDE

Storage and Handling of Gas Cylinders Guidelines

CARRIAGE OF GAS CYLINDERS BY ROAD IN CARS, VANS AND OTHER VEHICLES GUIDANCE FOR DRIVERS AT WORK

Compressed Gas Cylinder Safety

Compressed Gas Cylinder Storage and Handling Guide

Quebec Quebec Tel : Fax : MSDS: P10 (10% Methane in Argon) PRODUCT INFORMATION

COMMITTEE ON HERBAL MEDICINAL PRODUCTS (HMPC) FINAL COMMUNITY HERBAL MONOGRAPH ON HYPERICUM PERFORATUM L., HERBA (TRADITIONAL USE)

SAFETY DATA SHEET Perfluoro-2-methylpentane

Material Safety Data Sheet

BOC Supply Solutions

Guidance for Those Who Use and Store Gas Cylinders

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING SULPHURIC ACID DRAIN CLEANER

Questar Safety Data Sheet

BOC Healthcare Consultancy Services

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Compressed Gases The Dangers

Creation Date: Revision Date: Page: 1 of 7

PBX Series Quick Fit Connector Bimetallic Steam Traps

NEUROTONE THR 00904/0005 UKPAR

PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

M«: GHS04 : Warning : H280 - Contains gas under pressure; may explode if heated. : Asphyxiant in high concentrations.

SAFETY DATA SHEET NITROGEN, COMPRESSED

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION

MATERIAL SAFETY DATA SHEET NATURAL GAS (PIPELINE QUALITY - MSDS #526)

The Home Oxygen Handbook.

Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH) Printed revision Compressed-Air Spray (GB)

Oxygen Policy and Procedure

Safety Data Sheet Avesta Neutralization Agent 502

MATERIAL SAFETY DATA SHEET Revised edition no : 4. MœM« : Air Liquide Australia Limited. Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia

Safety Data Sheet. Product #: Aspira Scientific 521 Cottonwood Dr. Milpitas, CA

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

If you have any questions about how to safely undertake a task or project, ask your supervisor before you begin.

NITROUS TRANSFER PUMP INSTRUCTIONS

Assembly and Installation Procedures

Ingredient % content Hazard data Cross linked Sodium Polyacrylite CAS No: Non chemical fillers Zeolite 1-10

SAFETY DATA SHEET 安 全 数 据 单

SAFETY DATA SHEET. Section 1: Identification of the substance/mixture and of the company/undertaking. KaVo Everest ZS-Blanks und Ronden

WINDEX ORIGINAL GLASS CLEANER

Material Safety Data Sheet

PRODUCT ID: LIDOCAINE HYDROCHLORIDE AND EPINEPHRINE INJECTION

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

SAFETY DATA SHEET according to Regulation (EC) No. 453/2010 Dental Use

RISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL

PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31 CYTOFIXX (CYTOLOGICAL FIXATIVE)

Date: 22 June 2005 Version: 2 Revision: Identification of the substance/preparation and company/undertaking

Manufacturer/supplier information. Street/postbox: P.O. Box 15408

1. Product and Company Identification

INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES

UCLA - Compressed Gas Cylinder Storage and Handling

MATERIAL SAFETY DATA SHEET. PRODUCT NAME: BOSTON AEROSOL ENAMEL PAINT PRODUCT CODE: BT dependant on colour

Issue Date Supersedes. XR40 Absorbent Granule

: MR MUSCLE Window & Glass Cleaner

MATERIAL SAFETY DATA SHEET

What is Dry Ice? Dry Ice Company Safety Rules: DRY ICE: SAFETY DATA SHEET & RISK ASSESSMENT

Material Safety Data Sheet

Safety data sheet. 1.2 Relevant identified uses of the substance or mixture and uses advised against Use of the mixture Printing industry

TEMPORARY EMPLOYEES SAFETY PROCEDURES

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Transcription:

Medical Gas Data Sheet (MGDS) Medical air Essential safety information Summary of Product Characteristics (SPC) pages 2-6 Additional Safety Information pages 7-8 BOC: Living healthcare

2 Medical air SPC 1. Name of the medicinal product Medical air. 2. Qualitative and quantitative composition Medical air specification. Medical air cylinders are supplied to the following specification: oxygen content 20.9% O2 ± 0.5% nitrogen balance. The medical air cylinder specification complies with the European Pharmacopoeia monograph (1238). 3. Pharmaceutical form Medicinal gas, compressed. 4. Clinical particulars 4.1 Therapeutic indications Medical air is used: as a replacement for atmospheric air when the atmosphere is contaminated by noxious fumes, vapours or gases in anaesthesia as a carrier gas for volatile anaesthetic agents as a power source for pneumatic equipment in ventilators and incubators to provide uncontaminated and controlled air flows. 4.2 Posology and method of administration For breathing purposes medical air is administered by various means, commonly by self contained or compressed air line breathing apparatus. In anaesthesia, medical air is administered via a cylinder and valve assembly through a face mask or endotracheal tube. 4.3 Contraindications Medical air is contraindicated where oxygen or other gaseous combinations would be indicated (airways obstruction, pneumonia, and a myriad of cardio-respiratory conditions). 4.4 Special warnings and precautions for use Medical air should never be administered to a patient if, when it is mixed with other gases, the oxygen content is less than 21%. Care is needed in the handling and use of medical air cylinders. 4.5 Interaction with other medicinal products and other forms of interaction None applicable. 4.6 Pregnancy and lactation Medical air does not adversely affect pregnancy and lactation. 4.7 Effects on ability to drive and use machines The use of medical air does not affect the ability to drive or use machinery. 4.8 Undesirable effects None applicable.

3 5. Pharmacological properties 4.9 Overdose None applicable. 5.1 Pharmacodynamic properties The characteristics of medical air are: odourless, colourless gas molecular weight 29.00 boiling point -194 C (at 1bar(g)) density 1.225kg/m 3 (at 15 C). Atmospheric air contains approximately 21% oxygen, 78% nitrogen and 1% Argon with trace contents of other inert gases (xenon, neon, krypton). The nitrogen is absolutely inert, but the oxygen in air is an absolute necessity for life for its cellular respiratory function. 5.2 Pharmacokinetic properties Under conditions of normal atmospheric pressure, the pharmacokinetic data on medical air are essentially those of respiration, oxygen carriage and cellular metabolism and are inapplicable. 5.3 Preclinical safety data None stated. 6. Pharmaceutical particulars 6.1 List of excipients None. 6.2 Incompatibilities Medical air is non-flammable but supports combustion. 6.3 Shelf life 36 months. 6.4 Special precautions for storage Medical air cylinders should be: 6.5 Nature and contents of container stored under cover, preferably inside, kept dry and clean, and not subjected to extremes of heat or cold and away from stocks of combustible material stored separately from industrial and other non-medical cylinders stored to maintain separation between full and empty cylinders used in strict rotation so that cylinders with the earliest filling date are used first stored separately from other medical cylinders within the store F size cylinders and larger should be stored vertically. E size cylinders and smaller should be stored horizontally. Warning notices prohibiting smoking and naked lights must be posted clearly in the cylinder storage area and the emergency services should be advised of the location of the cylinder store. Care is needed when handling and using medical air cylinders. Medical air cylinder and valve details Medical air is supplied as a compressed medical gas in high pressure gas cylinders. All cylinders used for the storage of medical air are manufactured from high tensile steel. The E, F, G and J size cylinders are designed with working pressure of at least 137bar(g) and the T4 and T7 size cylinders are designed for a maximum working pressure of 230bar(g). Medical air cylinders are supplied with two main types of cylinder valves, dependant upon the cylinder filling pressure and the type of application. Conventional cylinder valves are fitted to all cylinders which are designed to be used with a pressure regulator. All of these cylinders are fitted with valves with outlet connections that conform to either IS0 407 (pin index) or BS 341. (5/8" BSP F) and are filled to 137bar(g).

4 Other high pressure cylinders are fitted with valves that have an integral pressure regulator, with an outlet pressure of 4bar(g) or 7bar(g) dependant on their intended use. These regulated valves are fitted with an IS0 5145 product specific filling connection and a product specific BS 5682 Schrader outlet connection. A summary of medical air cylinders, their size and construction, type of valve fitted and valve outlet pressure is detailed below: Cylinder Gas content Cylinder Valve type Nominal size (litres) construction outlet valve outlet connections pressure bar (g) AZ 170 Aluminium Pin Index 137 E 680 Steel Pin Index 137 F 1360 Steel Thumbwheel valve 137 BS 341 No.3 G 3400 Steel Top outlet MPR valve 137 BS 341 No.3 Top J 6400 Steel Outlet MPR valve 137 Side spindle pin T4 4600 Steel Index valve 4 Variable demand (0-300 litres/min) Integral regulated Valve with ISO 5145 product specific filling port and BS Schrader outlet (air 4bar(g)) T7 4600 Steel Variable demand 7 (0-300 litres/min) Integral regulated valve with ISO 5145 product specific filling port and BS Schrader outlet (air 7bar(g)) The basic specification for the cylinder valves used in medical air cylinders are: Valve body High tensile brass Spindle Steel Spindle tip Nylon 6.6 Valve outlet 5/8 BSP (F) side outlet Valve operation Handwheel O rings (T4/T7 only) Sintered bronze 6.6 Special precautions for disposal and other handling All personnel handling medical air cylinders should have adequate knowledge of: properties of the gas correct operating procedures for the cylinder precautions and actions to be taken in the event of an emergency. Preperation for use: Cylinders used with a pressure regulator. Sizes E, F, G, J. To prepare the cylinder for use: remove the tamper evident seal and the valve outlet protection cap. Ensure the cap is retained so that it can be refitted after use do not remove and discard any batch labels fitted to the cylinder ensure that an appropriate medical air regulator is selected for connection to the cylinder

5 ensure the connecting face on the regulator is clean and the sealing washer fitted is in good condition connect the regulator, using moderate force only and connect the tubing to the regulator/flowmeter outlet. Only the appropriate regulator should be used for the particular gas concerned open the cylinder valve slowly and check for any leaks The cylinder valves and any associated equipment is not lubricated and kept free from oil and grease. Cylinders with an integral regulated valve. Sizes T4 and T7. To prepare the cylinder for use: check the cylinder contents gauge on the cylinder valve to ensure that there is sufficient gas contents in the cylinder remove the tamper evident seal and cover fitted over the valve outlets ensure that the correct equipment is selected for connection to the cylinder connect the air Schrader probe to the Schrader outlet open the cylinder valve slowly and check for any leaks the cylinder valves and any associated equipment is not lubricated and kept free from oil and grease. Leaks Cylinders used with a pressure regulator. Sizes E, F, G, J. Having connected the regulator or manifold yoke to the cylinder check the connections for leaks using the following procedure: should leaks occur this will usually be evident by a hissing noise should a leak occur between the valve outlet and the regulator or manifold yoke, depressurise and remove the fitting and fit an approved sealing washer. Reconnect the fitting to the valve with moderate force only, fitting a replacement regulator or manifold tailpipe as required sealing or jointing compounds must never be used to cure a leak if leak persists, label cylinder and return to BOC. Cylinders with an integral regulated valve. Sizes T4 and T7. check the connection for leaks using the following procedure: should leaks occur this will usually be evident by a hissing noise close valve, remove connection, check and refit never use excessive force when connecting equipment to cylinders if leak persists, label cylinder and return to BOC. Use of cylinders After use When medical air cylinders are in use ensure that they are: only used for medicinal purposes turned off, when not in use, using only moderate force to close the valve only moved with the appropriate size and type of trolley or handling device handled with care and not knocked violently or allowed to fall firmly secured to a suitable cylinder support when in use not allowed to have any markings, labels or batch labels obscured or removed not used in the vicinity of persons smoking or near naked lights. When the medical air cylinders are empty ensure that the: cylinder valves is closed using moderate force only and the pressure in the regulator or tailpipe released valve outlet cap, where fitted, is replaced empty cylinders are immediately returned to an empty cylinder storage area for return to BOC.

6 7. Marketing authorisation holder BOC Ltd The Priestley Centre 10 Priestley Road The Surrey Research Park Guildford Surrey GU2 7XY 8. Marketing authorisation number(s) PL 0735/5002R 9. Date of first authorisation/ renewal of the authorisation Date first granted: 01/09/1972 Date of renewal: 21/07/1992 10. Date of revision of the text 24/04/1998 11. Dosimetry (if applicable) Not applicable. 12. Instructions for preparation of radiopharmaceuticals (if applicable) Not applicable.

7 Medical air Additional Safety Information 1. Contact information BOC telephone number to be used in the event of an emergency: UK 0800 111 333 2. Hazards Classification labelling and packaging regulations Warning. Contains gas under pressure; may explode if heated (H280). Protect from sunlight: store in a well-ventilated place. (P410 + P403). Dangerous Preperations Directive Keep out of the reach of children (S2). Additional safety statements No smoking or naked flames near medical gas cylinders. Use no oil or grease. Keep away from extremes of heat and combustible material. Store cylinders under cover in a clean, dry and well ventilated area. Medical air is supplied as a compressed gas in a high pressure cylinder. Cylinders may explode if subjected to extremely high temperatures (if involved in a fire). 3. Fire fighting measures If medical air cylinders are involved in a fire: if it is safe to move the cylinders, - close cylinder valve to stop flow of product - move cylinders away from source of heat if it is not safe to move the cylinders - cool with water from a protected position. All types of fire extinguishers may be used when dealing with a fire involving medical air cylinders. No special protective equipment for fire fighters is required. There are no hazardous combustion products released from the gas. 4. Accidental release measures If a large volume of medical air is released, if it is safe to do so, you should close the cylinder valve. 5. Exposure controls None. 6. Disposal considerations It is recommended that medical air cylinders should not be vented after use - they should be returned to BOC with any residual gas where they will be vented before refilling in a safe environment. If, for safety reasons, a cylinder is required to be vented after use, the gas should be vented to atmosphere in a well ventilated area. Contact BOC if further guidance on venting cylinders is required.

7 7. Transport of cylinders When medical air cylinders are required to be transported, ensure that the cylinders are: located in a compartment separated from the driver adequately restrained not leaking and have their valves closed. The vehicle must be adequately ventilated. Ensure the driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. It is advisable to provide the driver with written instructions that detail the actions to be taken in the event of an accident or emergency. Cylinders should be removed from the vehicle as soon as possible. 8. Transport information UN Number UN1002 Proper Shipping Name Air, compressed Material Class 2 Labels: 2.2. Hazard Identification Number 20 Emergency Action Code: 2T Tunnel Restriction code E Transport Category 3 BOC Healthcare Customer Service Centre, Priestley Road, Worsley, Manchester M28 2UT Tel: 0800 111 333, Fax: 0800 111 555, Email: bochealthcare-uk@boc.com, www.bochealthcare.co.uk The stripe symbol and the letters BOC are registered trade marks of The BOC Group Limited. Both BOC Limited and The BOC Group Limited are members of The Linde Group, the parent company of which is Linde AG. Reproduction without permission is strictly prohibited. Copyright 2009 HLC/405205/JIG/APUK/0410/3M