R&D Access Touch 4.0 User Manual Version 1.01 Public 1 (17) User Manual. Access Touch 4.0. Author: Hal File: C00717E Date:

Similar documents
R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Ensto Chago Master EVM300 and EVM500 Operational description

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Features Rich Expansion. Specifications Dimensions Optional Kit. Packing List Ordering Information Optional Modules

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Light Industrial Panel PC

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

Silvertel. Ag9800M. 1. Features. 2. Description. Miniature PoE Module. Small SMT package. IEEE802.3af compliant. Low cost

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

TX OPEN RS232/485 module

PCS0100en Persy Control Services B.V. Netherlands

GV- RK1352 Card Reader

ACR880 GPRS Portable Smart Card Terminal

2M IR Mini Dome Quick Installation Guide

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

PROXIMITY CARD READERS C-10, C-20, C60, C70

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

IOVU-571N ARM-based Panel PC

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

IntesisBox Modbus Server Fidelio IP

A-317. Mobile Data Terminal. Android Platform Datasheet

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox KNX Modbus TCP master

HMI display Installation Guide

Controller board and power supply for vivimat III systems

Power over Ethernet (PoE)

DK40 Datasheet & Hardware manual Version 2

Communication Unit 560CMU05 Data sheet

IntesisBox KNX Modbus RTU master

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200

ACR120 Technical Specifications version 2.9 November 2005

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

KNX Panasonic Air Conditioners

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

EMBEDDED ACCESS CONTROL Hardware Installation Guide

VTO6xxx. IP door stations. User manual

RFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink

VIA Eden 1GHz ULV Processor AFL-07A-CX2. HDD Drive Bay Optional HSDPA Module (support GSM 850,EGSM 900,DCS 1800 & PCS 1900) Mounting

FLYPORT Wi-Fi G

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

NC-12 Modbus Application

Lab Experiment 1: The LPC 2148 Education Board

Specifications. Product Description 18.5" Fanless, Intel ATOM D GHz Processor, Multi Function Panel PC

RC2200DK Demonstration Kit User Manual

Troubleshooting and Diagnostics

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

IntesisBox KNX LG Air Conditioning

II Intelligent PC/CAN Interface. Manual

Series. Laser air Leddura Lexinus Mensa. 70 inch. Smart innovation! When function matters.

IntesisBox KNX - LON

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

RFID MODULE Mifare Reader / Writer SL031 User Manual Version 2.7 Nov 2012 StrongLink

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

T3 Mux M13 Multiplexer

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Modbus Server SAMSUNG Air Conditioners

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

INSTALLATION MANUAL XM3 Reader

Technical Information Jumpers, Connectors and Memory JXM7031 (7031-xxx) MicroATX Motherboard Dual Jasper Forest Processors

HD Megapixel Indoor Network Camera Quick Start Guide

OC810 Outdoor Camera Setup Guide

Waveguide Access Point WGA631. Product Guide

MultiViu Flex 7 Data Sheet

HARTING econ 3000 Introduction and features

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

How to read this guide

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Matrix 510/520 User Guide

LBNP RS-232/485/422 serial device server. User manual

USB Plus+ RFID Reader Setup Guide

IFS SP-PoE Splitter User Manual

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Multifunction devices

Manual Serial PCI Cards

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

HARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC Lark Ave., Suite 200 Los Gatos, CA

Field Service Application

8-Port PoE Network Switch

Transcription:

Public 1 (17) User Manual Access Touch 4.0 Version Date Author Description 1.00 21.9.2015 Hal First version 1.01 15.12.2015 Hal Added connector 2

Public 2 (17) 1. Purpose of this user manual... 3 2. Other available documents... 3 3. Description of Access Touch 4.0... 3 4. Package content... 5 5. Notes... 5 6. Installation... 6 6.1. Installation, mechanics... 6 6.1.1. Exploded view... 6 6.1.2. Installation plate... 7 6.1.3. Back cover... 7 6.2. Installation, electronics... 8 6.2.1. Power supply... 8 6.2.2. Connector 1... 9 6.2.3. Connector 2... 10 6.2.4. Connector 3... 11 6.2.5. Connector 4... 12 6.2.6. Ethernet Connection... 13 6.2.7. PoE... 13 6.2.8. SD card connector... 14 6.2.9. USB Ports... 14 6.2.10. Reset button... 14 6.2.11. Boot... 14 6.2.12. Mic... 14 6.2.13. Line... 14 6.3. Mounting... 15 6.4. Booting... 15 7. System shutdown... 15 8. Dimensions... 15 8.1. Front panel measures... 15 8.2. Side measures... 16 9. Technical data... 17

Public 3 (17) 1. Purpose of this user manual The purpose of this manual is to give you information about Access Touch 4.0 screen terminal and help you install it. 2. Other available documents Please also see following documents for more information: -Access Touch 4.0 Protocol Description Description of communication between on board microcontroller and Computer on Module. Sensors (temperature sensor, external voltage, I/O-state..), LED control etc also described in this document -Access Touch 4.0 Open Embedded Build System -Access Touch 4.0 Embedded Linux OS Description 3. Description of Access Touch 4.0 Access Touch 4.0 is a touch screen terminal that: Enables you to manage a wireless identification system Can be used as an independent control unit Access Touch 4.0 consists of an integrated computer module and an RFID reader. It can be used for management of a wireless system or as an independent unit, for e.g. time and attendance, payment applications, alarm control, as an info screen etc. Access Touch 4.0 operates on Embedded Linux or Windows EC7 operating system. Access Touch 4.0 includes a fully operating integrated computer on module with great performance offering a variety of options for different types of customised solutions. Access Touch 4.0 has an integrated RFID reader unit, available with a variety of RFID technologies working on 125 khz and 13.56 MHz frequencies.

Public 4 (17) The front panel is fully customisable to your needs. The device consists primarily of a screen module with embedded electronics and a back plate for installation. Contact Idesco for special needs. E.g. display vertical orientation.

Public 5 (17) 4. Package content Access Touch 4.0 including RFID reader unit, one of following: 1. 7C 2.0: MIFARE DESFire: UID, MIFARE Classic: UID, MIFARE Ultralight UID, MIFARE Plus UID, MIFARE SmartMX (MIFARE Classic emulation mode) UID, NFC (UID), Mifare Classic 7 Byte UID 2. 8CD 2.0: MIFARE DESFire: UID + Application files, MIFARE Classic: UID + Sectors, MIFARE Ultralight UID + pages, MIFARE Plus UID security levels 1 and 3, MIFARE SmartMX (MIFARE Classic emulation mode), NFC (UID), Mifare Classic 7 Byte UID + sectors. 3. 7AH: UID-number of Sokymat Unique, EM 4102, HID Proximity 26, 34, 35, 37 and 40 bits 4. IR6090B2: Supporting Idesco Microlog technology 5. Other RFID reader modules available optionally Other optional equipment depending on specific order requirements: 1. WLAN USB module 2. Additional SSD memory 3. NOTE! Two additional USB ports available with default HW-configuration 5. Notes Handle the unit, especially the front cover, with care. Handle the electronics with care to avoid any electrostatic discharges Use a soft towel when cleaning the front panel It is recommended to deploy a power back up (UPS) for power interruptions.

Public 6 (17) 6. Installation NOTE! Power must be turned off when making connections! 6.1. Installation, mechanics 6.1.1. Exploded view Picture 1 Exploded view

Public 7 (17) 6.1.2. Installation plate Attach installation plate to wall/desk using four screws. See picture 2. Optionally installation plate can be installed on VESA-connector. Install four M3x12 screws loosely to installation plate as in picture 2. Picture 2 Installation plate 6.1.3. Back cover Install the back cover to the installation plate by hanging it on the loosely installed screws. See picture 3. Tighten the screws. Feed all necessary wires through seal on the back cover.

Public 8 (17) Picture 3 Back cover installation 6.2. Installation, electronics Connect all necessary wires to the Access Touch 4.0 PCB (e.g +Vin, GND, Relay control ) Use picture 4 to locate different connectors. Each connector s functions are described separately in the following chapters. Picture 4 Connections 6.2.1. Power supply Input voltage: 15...30 VDC Power requirements / average current consumptions:

Public 9 (17) 500 ma @ 15 VDC, (max 650mA) 350 ma @ 24 VDC, (max 400mA) Choose a power supply that meets the above power requirements. Connect wires to power supply connector. See picture 5. Picture 5 Power connection 6.2.2. Connector 1 Connector 1 is for external RFID-reader connection and includes following signals:

Public 10 (17) -WA0, wiegand port A signal 0 -WA1, wiegand port A signal 1 -WB0, wiegand port B signal 0 -WB1, wiegand port B signal 1 -INA, input port A -INB, input port B -+12V -GND Picture 6 Connector 1 Data from wiegand hubs is routed through the Access Touch 4.0 application controller. Consult the separate Access Touch 4.0 Protocol Description for wiegand output / input controls. Port data is read through the /dev/ttys0 port in Embedded Linux operating system. Consult the Access Touch 4.0 Embedded Linux OS Description for further information. Win EC7 default port settings: COM3 is connected to carrier board embedded software and baud rate is 9600 by default. 6.2.3. Connector 2 Connector 2 includes following signals:

Public 11 (17) -+12V -GND -TXD, RS232 -RXD, RS232 -RX-, RS422 -RX+, RS422 -B/T-, RS422/RS485 -A/T+, RS422/RS485 Picture 7 Connector 2 Communication signals are connected to Computer on Module. 6.2.4. Connector 3 Connector 3 includes following signals: -NC1, relay normally connected 1 -NO1, relay normally open 1 -CO1, relay change over 1 -SPKG, speaker ground -SPKR, speaker right -SPKL, speaker left -OUTD, FET output port D (see picture 8 for circuit diagram) -GND An output command can be sent to the application controller to drive the relay and FET output. See Access Touch 4.0 Protocol Description for control commands. Picture 8 Connector 3

Public 12 (17) Picture 9 OUT_D circuit 6.2.5. Connector 4 This connector is for debugging the Computer on Module. It has serial line signals with RS232 voltage levels. It has following signals: -RX, receive data -TX, send data -G, ground Picture 10 Debug connector See document Access Touch 4.0 Open Embedded Build System for entering Access Touch debug interface.

Public 13 (17) 6.2.6. Ethernet Connection Access Touch 4.0 is equipped with one Ethernet connection. This device supports the 10 / 100 Mbit Ethernet protocol. 6.2.7. PoE PoE (Power over Ethernet) of this device is designed to extract power from a conventional twisted pair Category 5 Ethernet cable, conforming to the IEEE 802.3af standard. 6.2.7.1. Input/Power sourcing This device s PoE input is compatible with equipment that uses different power options, see picture 10: System Diagram. However to fully power all functions of this device it is recommended to provide IEEE 802.3af compliant power to input. See Access Touch 4.0 Protocol Description for backlight LED commands. It is specified that the PSE does not apply power to both outputs at the same time (Refer to IEEE802.3af for more information). Picture 11 System diagram 6.2.7.2. PD Signature When the device is connected to the Cat 5e cable, it will automatically present a Powered Device (PD) signature to the Power Sourcing Equipment (PSE) or Midspan Equipment, when requested. This device provides a Class 0 signature. The equipment will then recognize that a powered device is connected to that line and supply power.

Public 14 (17) 6.2.7.3. Isolation To meet the safety isolation requirements of IEEE802.3af section 33.4.1 a Powered Device (PD) must pass the electrical strength test of IEC 60950 sub clause 6.2. This calls for either a) 1500Vac test or b) 1500V impulse test. This device is specified to meet the 1500Vdc impulse test. NOTE! For safety reasons, don t install any cables on top of POE-module! 6.2.7.4. Power Classification This device is fixed for Class 0 (0.44 Watts to 12.95 Watts) operation. 6.2.8. SD card connector Access Touch 4.0 has on SD card connector. Card type is micro SD. It can be used to read and write data from Computer on Module. See document Access Touch 4.0 Open Embedded Build System for booting OS from micro SD card or for updating Computer on Module from micro SD card. 6.2.9. USB Ports Access Touch 4.0 has two USB ports for external USB device connections. These ports are fully compliant with the USB 2.0 Specification. See picture 4 to locate the USB connectors. 6.2.10. Reset button Access Touch 4.0 has one reset button. It can be used for power-off. Device will automatically then restart. Before you do that, make sure the device is not performing any read/write operations. This isn t a preferable way to turn power off. 6.2.11. Boot To boot from SD-card, use Debug-connector and command prompt. See See Access Touch 4.0 Protocol Description for more information. 6.2.12. Mic Microphone can be connected via the MIC connection. Contact Idesco for more information. 6.2.13. Line This connector is for audio input. Contact Idesco for more information.

Public 15 (17) 6.3. Mounting After all connections have been completed, mount electronics and front plate on the back cover. Use four nuts in the corners. See picture 1. 6.4. Booting After all mechanical and electronic installations have been completed switch the power supply on. The computer will automatically initiate its boot routine. Note that the power-up routine may differ depending upon whatever features may have been configured in the device. The device will initiate booting of the installed operating system if no such configurations have been made. After the power-up routine completes your Access Touch 4.0 is ready for use. 7. System shutdown Do not suddenly remove power from the device! On Linux device use shell command halt. After halt procedure is finished (screen is black and device is not drawing any current) you can unplug your power source from the device. On Windows device select shutdown from Start menu. 8. Dimensions 8.1. Front panel measures Picture 12 Front panel

Public 16 (17) 8.2. Side measures Picture 13 Side measures

Public 17 (17) 9. Technical data Operating frequency for RFID / Wireless Power supply Current consumption CPU Memory Display and Touch Panel Dimensions Material of housing Installation method Protection class Operational temperature range Storage temperature range Interfaces Inputs Outputs Standards used for CE conformity LED (for the RFID reader) Backlighting 125 KHz or 13.56 MHz. 15... 30 VDC. Internal back- up capacitors for short power breaks and safe power down 500 ma @ 15 VDC, (max 880mA) 350 ma @ 24 VDC, (max 550mA) Freescale Vybrid ARM Cortex -A5, Cortex -M4 Integrated on- board flash drive 512MB NAND (8 Bit) Memory RAM 256MB DDR3 (16 Bit) Optional SSD memory can be used for data storage 7 display and capacitive touch panel Vertical orientation on request! 257 x 152 x 96 mm Plastic with glass front plate Screws with separate installation plate or with VESA connector IP20-0... +45 C -10... +50 C 2 x USB 2.0, 2 x Wiegand, Ethernet 10/100 Mbit LAN, RS232, RS485 Optional additionally: 1 x RS232, 1 x RS485 2 general purpose inputs One software controlled output (open collector) One software controlled relay Optional: Two additional software controlled outputs Directive 1999/5/EC for R&TTE Harmonised standard for safety: EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011+ A2:2013 Harmonised standard for RF: EN300330-1 V1.7.1 EN300330-1 V1.5.1 Directive 2004/108/EC for EMC Harmonised standard for EMC: EN301489-1 V1.9.2 EN301489-3 V1.6.1 Harmonised standard for RF and EMC in alarm systems: EN50130-4:2011 Directive 2011/65/EU for RoHS EN50581:2012 Red / Yellow LED. LEDs with colors green, blue and red. Can be turned on separately Ethernet PoE (Power over Ethernet) 10 / 100 Mbit LAN IEEE 802.3af compliant (12 Watt)