Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

Similar documents
STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

OraQuick HCV Rapid Antibody Test Customer Letter

Uni-Gold Recombigen HIV-1/2

ABORhCard. ABORhCard Package Insert ABO and Rh Blood Grouping Device

Use and Disposal of Sharps

Quality Assurance Guidelines for Testing Using Rapid HIV Antibody Tests Waived Under the Clinical Laboratory Improvement Amendments of 1988

Quality Assurance Guidelines for Testing Using the OraQuick Rapid HIV-1 Antibody Test

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

VENOUS BLOOD COLLECTION

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

STANDARD OPERATING PROCEDURE

Syringe. Product Usage Information: Precautions:

Caring for Your PleurX Pleural Catheter

Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions Definitions...

Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate of Waiver

POC.PC.17 Point of Care Testing AMNISURE PROCEDURE FOR RUPTURED FETAL MEMBRANES TABLE OF CONTENTS. 1.0 Principle of Procedure.. 2

Human Peripheral Blood Mononuclear Cell (PBMC) Manual

Infectious Waste Management Plan

OneStep Fecal Occult Blood RapiDip InstaTest. Cat #

How Does a Doctor Test for AIDS?

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

I-140 Venipuncture for Blood Specimen Collection

VACUETTE RNAgard Blood Tubes BioMaxi Blood RNA Purification Kit. For the collection, preservation and purification of RNA from whole blood

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

Annual Biomedical Waste Code Training

(800) Cryo-Cell.com

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

Central Line Blood Draw

Overview of CLIA-Waived Rapid HIV Tests and the HIV Rapid

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

LIAISON XL HCV Ab Accurate diagnosis of the early stage of HCV infection

Blood Sampling in Sheep AS-557-W

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use.

INTRODUCTION TO CLINICAL PRACTICE AND CLINICAL SKILLS 2nd Year MEDICAL YEAR 2009/2010

Gravity Bag Cord Blood Collection Method Training Manual

Sterile Dressing Change with Tegaderm CHG for Central Venous Catheter (CVC)

Parent & Healthcare Professional Instructions for the collection of Maternal & Umbilical Cord Blood

OSHA s Bloodborne Pathogens Standard

Administration of Meropenem For Child

Giving safe injections

RealLine HCV PCR Qualitative - Uni-Format

Leader s Guide E4017. Bloodborne Pathogens: Always Protect Yourself

Hemoglobin Testing using the Data Management HemoCue Analyzer

6.0 Infectious Diseases Policy: Student Exposure Control Plan

Coding and Billing. Commonly Asked Questions. Physician Office Reimbursement Guideline Q1. A1. Q2. A2.

9.Pediatric Procedures

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

Aptima Specimen Transfer Kit

POLICY 08:18:00 BLOODBORNE PATHOGENS CONTROL PLAN

LIAISON XL HBsAg Quant

& OSHA STANDARDS TARGET GROUP: Core Campus Nursing Students SECTION: Academic

HUMULIN 70/30 KwikPen

Objectives At the completion of this module, unlicensed assistive personnel (UAP) should be able to:

Bloodborne Pathogens

EXPOSURE CONTROL PLAN (sample) 1 Child Care Directors and Employers

Hepatitis and Retrovirus. LIAISON XL Accurate detection of HIV infection. HIV Ab/Ag FOR OUTSIDE THE US AND CANADA ONLY

CDC-Lipid Standardization Program. Laboratory Data Collection System (LDCS) Instruction Manual

Roger Williams University. Bloodborne Pathogens Exposure Control Plan

Hazardous Precautions. Prepared By: Hazardous Precautions Working Group Updated: March 2014

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

Aseptic Technique. A GMP/GTP Training Module

Dengue IgM ELISA. For the quantitative determination of IgM-class antibodies to Dengue Virus in serum.

PICC & Midline Catheters Patient Information Guide

Corporate Safety Infection Prevention Employee Health

BLOOD CULTURE COLLECTION GUIDELINES FOR PHLEBOTOMISTS (WITHIN REGION 6)

Biohazardous Waste and Sharps Disposal

CoaguChek System. User Manual. This is a CLIA waived system.

ClikSTAR - Important facts about your new insulin delivery device.

Human CD4+T Cell Care Manual

A P P E N D I X SAMPLE FORMS

UNIVERSITY OF NORTH FLORIDA BIOMEDICAL WASTE MANAGEMENT PLAN DEVELOPED BY: ENVIRONMENTAL HEALTH, SAFETY, INSURANCE & RISK MANAGEMENT

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)

Bloodborne Pathogens (BBPs) Louisiana Delta Community College

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

The Golden Rule of Specimen Collection: The Patient Test Result is Only as Good as the Sample We Get

Title: Fingerstick Glucose by Accu-Chek Inform

Utah Division of Solid and Hazardous Waste Solid Waste Management Program

Training on Standard Operating Procedures for Health Care Waste Management Swaziland 12 May, 2011

Please note: Contact Coppe Laboratories at if archival plasma samples need to be tested.

Recommendations for the Safe Use of Handling of Cytotoxic Drugs

Biohazardous, Medical & Biological Waste Guidance Chart

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Attachment D Infection Control Policy METHODS OF IMPLEMENTATION AND CONTROL

Bloodborne Pathogens. Updated

Achieving Independence

BLOOD COLLECTION. How much blood is donated each year and how much is used?

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Diagnosis of HIV-1 Infection. Estelle Piwowar-Manning HPTN Central Laboratory The Johns Hopkins University

Kean University BS Degree Program in Athletic Training BLOOD BORN PATHOGENS POLICY

MEDICAL WASTE MANAGEMENT

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Information for patients and nurses

INSTITUTIONAL POLICY AND PROCEDURE (IPP) Department: Manual: Section:

BLOOD BORNE PATHOGENS

AUTOCLAVE PROGRAM. SOP Bio-006 FOR THE USE OF AUTOCLAVE FOR STERILIZATION OF MATERIALS AND BIOLOGICAL WASTE SOP

REGULATED MEDICAL WASTE Q & A

Transcription:

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test Complexity: WAIVED for fingerstick whole blood and venipuncture whole blood. A Certificate of CLIA Waiver is required to perform the test in a waived setting. Additional CLIA waiver information is available at the Centers for Medicare and Medicaid website at www.cms.hhs.gov/clia or from your state health department. Failure to follow the instructions, or modifications to the Test instructions, will result in the Test no longer meeting the requirement for Waived Classification and will be subject to all applicable CLIA requirements. These instructions are only a Reference Guide. For complete information including Restrictions, Precautions, and Limitations of the Test, refer to the OraQuick HCV Rapid Antibody Test Package Insert. Read these instructions completely before using the product. Follow the instructions carefully when performing testing. Not doing so may result in inaccurate test results. Before performing testing, all operators MUST read and become familiar with Universal Precautions for Prevention of Transmission of Human Immunodeficiency Virus, Hepatitis A Virus, Hepatitis B Virus, and other Bloodborne Pathogens in Health-Care Settings. 1,2 Item#3001-1529-70 rev. 11/11 OQ HCV Step-by-Step, US Accurate Rapid Result Easy to Use

Developer Solution Vial Reusable Test Stand Result Window OraQuick HCV Test Device Flat Pad (built-in collection pad) Specimen Collection Loop Absorbent Packet INTENDED USE: The OraQuick HCV Rapid Antibody Tests is a single-use immunoassay for the qualitative detection of antibodies to hepatitis C virus (anti-hcv) in fingerstick whole blood specimens and venipuncture whole blood specimens (EDTA, sodium heparin, lithium heparin, and sodium citrate) from individuals 15 years or older. The OraQuick HCV Rapid Antibody Test results, in conjunction with other laboratory results and clinical information, may be used to provide evidence of infection with HCV (state of infection or associated disease not determined) in persons with signs or symptoms of hepatitis and in persons at risk for hepatitis C infection. WARNING: This assay has not been FDA approved for use in patient populations without signs, symptoms, or not at risk for hepatitis C infection. Not for use in screening whole blood, plasma, or tissue donors. Performance characteristics have not been established for testing a pediatric population less than 15 years of age or for pregnant women. If you are a new operator, before proceeding you MUST be able to correctly interpret the OraQuick HCV Visual Reference Panel prior to using the OraQuick HCV Rapid Antibody Test. Failure to read at low intensities can result in the inability to detect specimens near the limit of detection of the OraQuick HCV Rapid Antibody Test and may result in false negative results. NOTE: Handle all blood specimens and materials contacting specimens as if capable of transmitting infectious agents. Dispose of all test specimens and materials used in the test procedure in a biohazard container. 1 1 See Universal Precautions, CDC, MMWR, 1988; 37(24):377-388. 2 Guideline for Isolation Precautions, CDC, HICPAC, 2007; 12-93.

FOR IN VITRO DIAGNOSTIC USE THE FOLLOWING ITEMS ARE NEED TO DO THE TEST: The OraQuick HCV Rapid Antibody Test Consists of a Divided Pouch Containing the Following: Single-Use Test Device (including an absorbent packet) Developer Solution Vial (containing.750 ml) NOTE: The pouch is divided into two chambers. One chamber holds the Test Device while the other chamber holds the Developer Solution Vial. Materials Provided in the Kit: Reusable Test Stands Package Insert Specimen Collection Loops Materials Required But Not Provided: Timer or watch capable of timing 20 to 40 Minutes Materials required for venipuncture whole blood specimen collection OraQuick HCV Visual Reference Panel Biohazard waste container Sterile lancet to obtain a fingerstick whole blood specimen OraQuick HCV Rapid Antibody Test Kit Controls EXTERNAL QUALITY CONTROL OraQuick HCV Rapid Antibody Test Kit Controls are available separately for use only with OraQuick HCV Rapid Antibody Test. The Kit Controls are specifically formulated and manufactured to ensure performance of the Test, and are used to verify your ability to properly perform and test and interpret the results. Refer to the Kit Control Package Insert for complete instructions. Run the Kit Controls under the following circumstances: Each new operator prior to performing testing on patient specimens, When opening a new test kit, Whenever a new shipment of test kits is received, If the temperature of the test kit storage area falls outside of 2 30 C (36 86 F), If the temperature of the testing area falls outside of 15 37 C (59 99 F), At periodic intervals as dictated by the user facility. Test Procedure for Kit Controls 1. Open a Kit Control vial containing the control reagent. 2. Insert the rounded end of an unused Specimen Collection Loop into the vial of control reagent. Visually inspect the loop to make sure that it is completely filled with the control reagent. Use separate unused Specimen Collection Loops for each control reagent. 3. Immediately immerse the control-reagent filled Specimen Collection Loop into the Developer Vial. Use the Specimen Collection Loop to stir the specimen in the developer solution. Remove the Specimen Collection Loop from the Developer Vial and discard the used loop in a biohazard waste container. 4. Follow Step 3 Testing Procedure for additional instruction.

SET UP YOUR WORKSPACE Gather the materials you will need. Allow the test kit to come to operating temperature (15 37 C; 59 99 F) before use. Refer to the External Quality Control section above to determine when the Kit Controls should be run. Set an OraQuick HCV Reusable Test Stand ( Stand ) on your workspace. Use only the Stand provided. Disposable gloves are needed when performing the test. GENERAL TEST PREPARATION A1 Two Chambers A2 A3 If you are a new operator, you MUST be able to interpret all devices provided in the OraQuick HCV Visual Reference Panel prior to using the Oraquick HCV Rapid Antibody Test. Allow all components to come to operating temperature (15 37 C, 59 99 F). Place the resuable Test Stand on your workspace. Use only the Stand provided with the OraQuick HCV Rapid Antibody Kit. Set up your timer for 20 to 40 minutes but DO NOT start. Do not open the pouch until you are ready to perform a test. Check the pouch for damage or holes. Discard the pouch if it is damaged (see picture A1). After opening the pouch, check for an absorbent packet. If it is not present or appears damaged, discard the pouch and open a new one (see picture A2). Hold the Developer Solution Vial firmly in your hand. Remove the cap by rocking it back and forth while pulling it off. Set the cap aside. Slide the Vial into the tops of one of the slots in the Stand (see picture A3). Leave the OraQuick HCV Test Device in the pouch until testing is started. Refer to Step 3 in the Testing Procedure section. DO NOT cover the 2 holes on the back of the OraQuick HCV Test Device with labels or other materials. Blocking the holes may cause an invalid result.

SPECIMEN COLLECTION PROCEDURE FINGERSTICK WHOLE BLOOD B1 B3 B2 B4 Handle NOTE: If the Loop is dropped or comes in contact with any other surface, discard it in a biohazard waste container. Get a new Loop for the collection of the blood sample. Step 1A COLLECT Using an antiseptic wipe, clean the finger of the person being tested. Allow the finger to air dry. Using a sterile lancet, puncture the skin just off the center of the finger pad. Hold the finger downward. Apply gentle pressure beside the point of the puncture. Avoid squeezing the finger to make it bleed (see picture B1). Wipe away the first drop of blood with a sterile gauze pad. Allow a new drop of blood to form. Pick up an unused Specimen Collection Loop ( Loop ) by the thick handle end (see picture B2). Put the rounded end of the Loop on the drop of blood (see picture B3). Make sure that the Loop is completely filled with blood (see picture B4). VENIPUNCTURE WHOLE BLOOD B5 Handle B6 B7 Step 1B COLLECT Using standard venous phlebotomy procedures, collect a whole blood sample using a tube containing any of the following anticoagulants: EDTA (lavender top), sodium/lithium heparin (green top), or sodium citrate (light blue top). Other anticoagulants have not been tested and may give an incorrect result. If the specimens are not tested at the time of collection, the whole blood may be stored at 2 8 C (36 46 F) for up to 7 days or at 15 30 C (59 86 F) for up to 3 days. Prior to testing, mix the blood tube gently by inversion several times to ensure a homogeneous specimen. Pick up an unused Specimen Collection Loop ("Loop") by the thick "handle" end (see picture B5). Put the "rounded" end of the Loop into the tube of blood (see picture B6). Make sure the Loop is completely filled with blood (see picture B7). NOTE: If the Loop is dropped or comes in contact with any other surface, discard it in a biohazard waste container. Get a new Loop for the collection of the blood sample.

TESTING PROCEDURE B8 B9 Step 2 MIX Immediately insert the blood-filled end of the Loop all the way into the Vial (see picture B8). Use the Loop to stir the blood sample in the Developer Solution ( Solution ) (see picture B9). Remove the used Loop from the Solution. Throw the used Loop away in a biohazard waste container. Check the Solution to make sure that it appears pink. This means that the blood was correctly mixed into the Solution (see picture B10). If the Solution is not pink, discard all the test materials in a biohazard waste container. Start the test over. Use a new Pouch and a new blood sample. B10 B11 Flat Pad B12 B14 Absorbent Packet B13 B15 Step 3 TEST Remove the Device from the Pouch. DO NOT touch the Flat Pad (see picture B11). Check to make sure that an Absorbent Packet is included with the Device (see picture B12). If no Absorbent Packet is present, discard the Device and obtain a new Pouch for testing. Insert the Flat Pad of the Device all the way into the Vial containing the blood sample (see picture B13). Make sure that the Flat Pad touches the bottom of the Vial. The Result Window on the Device should be facing towards you (see picture B14). Start timing the test (see picture B15). DO NOT remove the Device from the Vial while the test is running. Pink fluid will appear and travel up the Result Window. The pink fluid will gradually disappear as the test develops. Wait 20 minutes.. Read the results after 20 minutes but not more than 40 minutes in a fully lighted area. Refer to the Test Result and Interpretation section in these instructions.

TEST RESULT AND INTERPRETATION Refer to the Result Window on the Test Device CAUTION: Adequate lighting required. Color blindness may affect the ability to interpret Test results. REACTIVE: Lines in C and T Zones Line in T Zone Line in T Zone Faint Line in T Zone Test is Reactive if: A line appears in the C Zone and a line appears in the T Zone. Lines may vary in intensity. Two lines must be present for a reactive result. The test is reactive regardless of how faint these lines appear. A Reactive test result means that HCV antibodies have been detected in the specimen. Patient is presumed to be infected with HCV. Follow appropriate guidelines for supplemental testing. NON-REACTIVE: Lines in C Zone Only Test is Non-Reactive if: A line appears in the C Zone and NO line appears in the T Zone. A Non-Reactive test result means that HCV antibodies were not detected in the specimen. Patient is presumed not to be infected with HCV. Line in C Zone No HCV antibodies detected. INVALID: No Lines in C Zone or Partially Developed Lines No Line in C Zone Red background obscures results Test is Invalid if: No line appears in the C Zone, or A pink background obscures the results during the 20-40 minute read time, or Any partial line appears on one side of the C or T Zones. An Invalid test result means that there was a problem running the test either related to the Specimen or to the Test Device. An Invalid result cannot be interpreted. Repeat the test with a new Pouch and a new Specimen. Contact OraSure Technologies Customer Service if you are unable to get a valid test result upon repeat testing. Partial Line on one side of C or T Zones For answers to questions or technical assistance regarding the OraQuick HCV Rapid Antibody Test, call: 1-800-ORASURE (800-672-7873) or visit our web site: www.orasure.com

GENERAL TEST CLEAN UP Dispose of the used test materials in a biohazard waste container. Change your gloves between each test to prevent contamination. Throw away the used gloves in a biohazard waste container. Use a freshly prepared 10% solution of bleach to clean up any spills. For answers to questions or technical assistance regarding the OraQuick HCV Rapid Antibody Test, call: 1-800-ORASURE (800-672-7873) or visit our web site: www.orasure.com Order Description Reimbursement CPT Code Information Box of 25 tests Information 86803 Box of 100 tests Controls OraQuick HCV Visual Reference Panel 220 East First Street Bethlehem, PA 18015 USA phone: 800.ORASURE web: www.orasure.com Made in the USA Please refer to the package insert for complete information and instructions on the proper use of the OraQuick HCV Rapid Antibody test. 2009, 2011 OraSure Technologies, Inc. U.S. Patent #7,192,555, #7,541,194 and various international and U.S. patents pending. OraQuick is a registered trademark of OraSure Technologies, Inc. Item# 3001-1529 rev. 11/11