LAGOON WATER TREATMENT. Dr. Rakesh Govind NewGen Biomedia, LLC 1776 Mentor Avenue Cincinnati, OH Cell: (513)

Similar documents
MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

WASTEWATER TREATMENT OBJECTIVES

Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.

GUIDELINES FOR LEACHATE CONTROL

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

Example Calculations Evaluation for Fine Bubble Aeration System. Red Valve Company, Inc. 700 NORTH BELL AVENUE CARNEGIE, PA

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

Bioremediation of Petroleum Contamination. Augustine Ifelebuegu GE413

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

Glossary of Wastewater Terms

CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES

OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.

Appendix 2-1. Sewage Treatment Process Options

Floating Treatment Wetland Technology: Nutrient Removal from Wastewater

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Best Practice Guide NO. BPGCS002. Wastewater Treatment Activated Sludge Process

Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008

Operation and Maintenance of Onsite Waster Systems in Maryland. A growing challenge for the industry and regulators

Sewage and Wastewater Odor Control Dr. Giancarlo Riva, Ozono Elettronica Internazionale, Muggio, Italy

Unit 1. Physical, chemical and biological Characteristics of Wastewater

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

ADVANCED LAGOON TREATMENT TECHNOLOGIES FOR WASTEWATER TREATMENT


Orange County Sanitation District

Treatment Industries. Wagga Wagga New South Wales 2650

WISCONSIN WASTEWATER OPERATORS ASSOCIATION

Aerobic Treatment Systems Guidance Document

Aeration Efficiency Guide

Total Suspended Solids Total Dissolved Solids Hardness

Combination of advanced aeration system and membrane bioreactor for winery waste water treatment

The Use of Magnesium Hydroxide Slurry as a Safe and Cost Effective Solution for H 2

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.

Biological Wastewater Treatment

SECTION 6 EXISTING WASTEWATER MANAGEMENT SYSTEMS

BALANCING REDOX EQUATIONS. Each redox equation contains two parts -- the oxidation and reduction parts. Each is balanced separately.

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Cambridge Wastewater Treatment Facility

Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries

Water Treatment and Reverse Osmosis Systems

Alberta Onsite Wastewater Management Association Installer Training Program

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Area & Volume. 1. Surface Area to Volume Ratio

Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence

Grit Removal Systems Simple, low cost, effective grit removal to enhance plant performance

Chapter 3. Table E-1. Equilibrium data for SO 2 at 1 atm and 20 o C. x y

Iowa DNR Wastewater Treatment Technology Assessment No

Chapter 6 Odor Control

SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY

ANAEROBIC/ANOXIC TANKS

1 Environmental Leverage Inc Dogwood Dr. Suite A, North Aurora, IL EnvironmentalLeverage.com

Module 17: The Activated Sludge Process Part III

Objectives. Describing Waterflooding. Infill Drilling. Reservoir Life Cycle

1.3 Wastewater and Ambient Water Quality

Advanced Wastewater Treatment and Disposal Systems. Water and Wastewater Utility Operation and

Engineers Edge, LLC PDH & Professional Training

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa

CONDENSED CATALOG

PROPAK AquaBio Complete Water Restoration Systems

Enhancing Nitrification in an Oil Refinery WWTP with IFAS

Best Practice in Boiler Water Treatment

THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL

CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810

Iron and Steel Manufacturing

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Choosing an Effluent Treatment Plant

Sewage (Wastewater) Treatment *

Wastewater Nutrient Removal

Description of the Water Conserv II Facility

CHEMISTRY STANDARDS BASED RUBRIC ATOMIC STRUCTURE AND BONDING

THE NWF WATER PURIFICATION PROCESS FRESH WATER IN A NATURAL WAY. Esko Meloni Ferroplan Oy

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

VCE CHEMISTRY UNIT 2 Environmental Chemistry SAMPLE COURSE OUTLINE

BLUE PLAINS - WASHINGTON DC NUTRIENT & ENERGY RECOVERY FACILITY

Saudi Aramco Project Development

WWTP RETROFIT. Smith & Loveless Inc. Also in this issue: Do You Have Emergency Backup? Aging Clarifiers Retrofit to Like New

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Technologies for Water Pollution Control - Wang Jianlong

National Precast Concrete Association

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Homeowner s Guide to Maintaining a Sewage Treatment System

Reactor Clarifier Solids Contact Clarifiers

5.2. Vaporizers - Types and Usage

Facility Classification Standards

Chemistry at Work. How Chemistry is used in the Water Service

Coagulation and Flocculation

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. Water & Wastewater Treatment Solutions

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Water Specialists for the Petrochemical Sector. ovivowater.com. creating value in water through innovation, creativity and expertise

Northport/Leelanau Township Wastewater Treatment Facility

Putting a chill on global warming

EXAMPLE EXERCISE 4.1 Change of Physical State

Bioremediation. Introduction

Complete Solutions for On-Site Wastewater Management

DANISH GUIDELINES FOR SMALL CONSTRUCTED WETLAND SYSTEMS Hans Brix

Transcription:

LAGOON WATER TREATMENT Dr. Rakesh Govind NewGen Biomedia, LLC 1776 Mentor Avenue Cincinnati, OH 45212 Cell: (513) 673 3583 Email: rgovind837@aol.com

WATER TREATMENT NEEDS Good mixing of liquid Dissolved Oxygen in water Active bacteria Ability to remove inorganics, such as ammoniumnitrogen, phosphorus, metals, etc.

DISSOLVED OXYGEN IN WATER

OXYGEN TRANSFER BASICS There are various wastewater characteristics that affect the amount of Oxygen that gets dissolved in wastewater: Soluble salts (TDS), particulate (TSS), surface active substances (algae, O&G), temperature, atm pressure, et. al. 4

OXYGEN TRANSFER BASICS continued Additionally, the solubility of oxygen is also impacted by other mechanical and kinetic properties: Tank geometry (circular, rectangular, square, etc.; rounded corners, conical bottom, height of tank, material of construction, in-ground, above ground, etc. Type of aeration device, Intensity of mixing (Reynolds Number) 5

OXYGEN TRANSFER BASICS The Standard Oxygen Transfer Rating (SOTR) is a unit of measurement that quantifies the oxygen transfer efficiency of a specific type of aeration device using either a Buoyancy or Kinetic oxygen transfer model. The Standard is maintained by the ASCE and all testing is done in Clear Water. continued 6

OXYGEN TRANSFER BASICS continued Because the ASCE testing is done in clear water (low TDS, TSS, etc.) there are three (3) values that are used to correct for the wastewater characteristics to develop an AOTR (Actual O2 Transfer Rating): The alpha (α) value corrects for the type of aeration device, tank geometry, intensity of mixing. 8

OXYGEN TRANSFER BASICS continued The beta (β) value corrects for soluble salts (TDS), particulate (TSS), surface active substances, etc. The theta (ϕ) value adjusts for the solubility of oxygen at specific temperatures. All aeration devices have a standard SOTE however, their values must be adjusted for the above three values for an AOTR. 9

ABSORPTION AERATOR MECHANISM Absorption Aerator Circulating Flow

VARIOUS KINETIC TRANSFER MODEL MECHANICAL AERATION DEVICES SOTE Following are various AOTR s for mechanical aeration devices: lbs. O 2 /hp/hr Absorption Aerator 2.73-3.06 Surface aerator w/draft tube 1.2-2.1 Surface high speed 1.2-2.0 Submerged turbine 1.0-2.0 Submerged turbine/sparger 1.2-1.8 Surface brush and blade 0.8-1.8 Fine Bubble Diffusers 0.5-1.5 11

ABSORPTION AERATOR The Absorption Aerator process has a high oxygen transfer efficiency because of the following factors: High Gas / Liquid ratio: 2.2 : 1.0 Intensity of mixing is internal in the device s mixing & oxidizing zone. Constant supply of an oxygen-deficient film to overcome the resistance of a partially oxygenated liquid (Two film theory). 12

ABSORPTION AERATOR continued Kinetic force of the discharge is used for mixing and equalization (2 fps). The best use of this feature is in a circular tank. Stripping substances with weak Henry s constants, e.g. CO 2 and VOCs. Oxidizing sulfur-containing molecules, e.g. hydrogen sulfide and -mercaptans for effective odor and corrosion control. 13

ABSORPTION AERATOR continued Degassing of gases imbedded in organic materials enhances settling of solids in clarifiers. Large amounts of induced DO cause fats, oils, and grease to hydrolyze and float for skimming. By stripping CO 2 ph is raised allowing for nitrification (ph >6.8) to begin. 14

INTERDEPENDENCE OF ph, ALKALINITY AND CO2 A formula for ph showing the interdependence of ph, alkalinity and carbon dioxide: ph = 6.35 + log(alkalinity/carbon dioxide)

ABSORPTION AERATOR continued BOD Reduction, the large amounts of DO immediately allow BOD reduction begin. The water nozzle has a pressure differential that causes organic materials to break apart (implosion) which increases their surface area making them more readily available for microbial digestion. 16

APPLICATIONS OF ABSORPTION AERATOR Mixing and Equalization Supernatant aeration from digesters Landfill leachate aeration prior to headworks. Oil & Grease Recovery. continued Effluent aeration to streams or wetlands. Stripping PCE, TCE, etc. from industrial wastestreams and groundwater. Lagoon aeration with two zones. 17

PHOTOGRAPHS OF MICROBUBBLES GENERATED BY THE ABSORPTION AERATOR SYSTEM Nozzle with flow from Absorption Aerator Water Intake Cloud of Microbubbles Tank full of Microbubbles

WATER INTAKE RISERS AT THE BOTOM OF LAKE Risers are off the bottom to prevent turbidity increase and sediment re-suspension

Gorman Rupp Pump Inlet Suction Pipe Absorption Aerator Discharge Pipe to nozzles

POND AERATION SYSTEM 4 inch Absorption Aerator Water Discharge Pipe Gorman Rup Pump

DESIGN CONSIDERATIONS Start with total oxygen demand required for desired reductions and sizing unit(s). Determine what features need to be factored into the design. Flooded or lift suction. Location of equipment. Use of Gorman-Rupp self-priming pumps. 22

MIXING OF THE WATER IN THE LAGOON

USE OF NOZZLES Mixing Nozzles provide dynamic mixing under pressure, which results in great mass transfer. PRD Tech, Inc. s nozzles allow the delivery of treatment gases to any depth all within a compact design, with trouble-free operation and easy installation. Various models are available for different applications.

ADVANTAGES OF USING NOZZLES Enhanced Gas/Liquid Interface Renewal Dynamic mixing under pressure yields greater mass transfer Desired back pressure to the Aerator Delivery of treatment gases to any depth Compact design for trouble free operation and ease of installation Highly durable PVDF thermoplastic construction Various models designed to match your application

ACTIVE BACTERIA IN THE LAGOON

USE OF BIOMEDIA IN LAGOON Biomedia allows active bacteria to grow on its surface and form active biofilms; Biofilms allows conversion of nitrates/nitrites to nitrogen gas (denitrification); Biofilms allows biological removal of phosphorus from the water; Biomedia increases the concentration of active biomass in the water by several fold when compared to suspended cultures, such as in activated sludge

BIOMEDIA USED IN LAGOONS NewGen Biomedia Characteristics Shape Material Dimension Value Hexagonal Plastic, Ceramic 11.5 in hexagon, 3 in thick Void fraction (vol %) 96 Density (lb/ft 3 ) 3.2 Surface Area (ft 2 /ft 3 ) 187

USE OF BIOMEDIA IN LAGOON Even in lagoons with no water flow in and out of the Lagoon, this type of treatment can treat the water in-place (in-situ) with no water being pumped in and out of the lagoon.

ADVANTAGES OF IN-SITU LAGOON WATER TREATMENT Does not require an external water treatment system, with water being pumped in and out of the lagoon; Very cost effective compared with an external water treatment system with water pump around; Removes Biological Oxygen Demand (BOD), Nitrates, Nitrites, Phosphorus, Metals, Total Suspended Solids (TSS), Organics, etc.

IN-SITU LAGOON WATER TREATMENT Water Recirculation Microbubbles Nozzle Air Pressure Tubing Blower In-Situ Water Treatment is achieved with no water pump around system. Media stack waves around in the water, but stays in place, as the water moves around it, and gets treated by the active biofilms on the surface of the biomedia The air is injected in the form of microbubbles at the bottom of the Biomedia stack, and provides dissolved oxygen in the recirculating water Several Biomedia stacks in one lagoon can effectively treat the water The air blower is kept outside the water for easy access.

SUMMARY The in-situ lagoon water treatment system is simple, easy to install and has few moving parts; The Absorption Aerator process is simple, easy to install into existing systems, has no moving parts. The mechanical energy is derived from the pump accelerating the liquid through the Absorption nozzle creating the vacuum to aspirate ambient air into process liquid. The Absorption Aerator process provides many enhancements to existing wastewater treatment systems and their performance.