Extractables and Leachables for Filters, Bags and Other Components

Similar documents
COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) COMMITTEE FOR MEDICINAL PRODUCTS FOR VETERINARY USE (CVMP)

Integration of a disposable system in a traditional manufacturing process to terminal sterilization

Elastomeric Components for Pharmaceutical Applications - Actual Quality Trends - Claudia Petersen. -Senior Manager Biotechnology-

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

EXTRACTABLES AND LEACHABLES FOR MEDICAL DEVICES: MEETING THE 510 (k) REQUIREMENTS

Lenntech Tel Fax

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

Extemporaneously Prepared Early Phase Clinical Trial Materials

How To Test For Leachables

USP Plastic Packaging General Chapters: An Overview

REACH Understanding the Risk Assessment Process

Quality Risk Management The Pharmaceutical Experience Ann O Mahony Quality Assurance Specialist Pfizer Biotech Grange Castle

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Implementing New USP Chapters for Analytical Method Validation

Regulations for Handling Samples and Laboratory Testing from R&D through Phase III Clinical Trials

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic

Preparing for the Pre-Approval Inspection What to do Before the FDA Arrives. Barry A. Friedman, Ph.D. Consultant

Cleaning Validation in Active pharmaceutical Ingredient manufacturing plants

Quality Systems Appropriate for Extemporaneously Prepared Early Phase Clinical Trial Materials. Agenda Topics for Discussion

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs

Importing pharmaceutical products to China

Terminal Sterilization. vs. Aseptic Processing

Regulatory Expectations for GMP: What s Happening. Patricia Weideman, PhD Director, Product Quality & Occupational Toxicology Genentech, Inc.

Comparative analysis between the possible regulatory approaches to GMP compliance TITOLO PRESENTAZIONE

Guidance for Industry

EUROPEAN COMMISSION HEALTH AND CONSUMERS DIRECTORATE-GENERAL. EudraLex. The Rules Governing Medicinal Products in the European Union

EudraLex. The Rules Governing Medicinal Products in the European Union Volume 4

Guideline on stability testing for applications for variations to a marketing authorisation

Journal of Chemical and Pharmaceutical Research

Global Lab Capabilities Pharma Biotech

IMPURITIES IN NEW DRUG PRODUCTS

Microbiology and Auditing. Don Singer

Guidance for Industry

ICH Topic Q 1 A Stability Testing Guidelines: Stability Testing of New Drug Substances and Products

Annex 7 Guidelines on pre-approval inspections

ANDA CHECKLIST FOR CTD or ectd FORMAT FOR COMPLETENESS and ACCEPTABILITY of an APPLICATION FOR FILING

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

Combination Products. Presented by: Karen S. Ginsbury For: IFF March PCI Pharma

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Impact Assessment in a Science & Risk Based Environment. R. Legland 11/04/11

GUIDELINE ON ACTIVE PHARMACEUTICAL INGREDIENT MASTER FILE (APIMF) PROCEDURE 1 (The APIMF procedure guideline does not apply to biological APIs.

Media fills Periodic performance qualification (Re-Validation)

Food, Medicine and Health Care Administration and Control Authority

Process Validation: Practical Aspects of the New FDA Guidance

Veterinary Compounding

State of Control Over the Lifecycle and Process Validation (New and Legacy Products)

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Assembly and Installation Procedures

Having regard to the Treaty establishing the European Economic Community, and in particular Article 100 thereof;

The purpose of this Supplier Quality Standard is to communicate the expectations and requirements of Baxter Healthcare Corporation to its suppliers.

Guideline on Process Validation

Guidance for Industry

Recent Updates on European Requirements and what QPs are expected to do

Technology Transfer of CMC Activities for MAb Manufacturing ge healthcare (

GEA Niro Pharmaceutical GMP Spray Drying facility. Spray drying process development and contract manufacturing. engineering for a better world

HOMEOPATHIC MEDICINAL PRODUCT WORKING GROUP (HMPWG) GUIDANCE ON MODULE 3 OF THE HOMEOPATHIC MEDICINAL PRODUCTS DOSSIER

Qualified Persons in the Pharmaceutical Industry Code of Practice 2009, updated August 2015

Session 6: WHO Prequalification Programme. Key Process Steps WHO: Medicines UNFPA: Condoms and IUDs

NEW CHEMICAL ENTITIES

REPORT FOR INTERNATIONAL COOPERATION ON COSMETIC REGULATION (ICCR)

Working with ICH Quality Guidelines - the Canadian Perspective

COMMITTEE FOR PROPRIETARY MEDICINAL PRODUCTS (CPMP)

GMP Pharma BV. Netherlands

Guidance for Industry: Starting Material Supplier Management

White paper: FDA Guidance for Industry Update Process Validation

Guidance for Industry

Working Party on Control of Medicines and Inspections. Final Version of Annex 16 to the EU Guide to Good Manufacturing Practice

EDQM: 50 YEARS OF LEADERSHIP IN THE QUALITY OF MEDICINES PAVING THE WAY FOR THE FUTURE

GUIDE TO GOOD MANUFACTURING PRACTICE FOR MEDICINAL PRODUCTS ANNEX 15 *

Analytical Challenges presented by leachables from sample container closure systems in drug products

General Principles for the Safety Assessment of Excipients

PROPOSED UPDATED TEXT FOR WHO GOOD MANUFACTURING PRACTICES FOR PHARMACEUTICAL PRODUCTS: MAIN PRINCIPLES (JANUARY 2013)

Sterile Cleanroom Management

WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D

Auditing as a Component of a Pharmaceutical Quality System

The Formalized Risk Assessment for Excipients A Practical Approach. Frithjof Holtz, IPEC Europe Vice-Chair, Merck

Overview of Drug Development: the Regulatory Process

Regulation and Risk Management of Combination Products

Overview of Key Obligations Under Regulation (EC) No. 1272/2008 on the Classification, Labelling and Packaging of Substances and Mixtures (CLP)

ICH guideline Q10 on pharmaceutical quality system

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

GMP Issues for Start-Ups, quality in the supply chain and role of the Qualified Person (QP)

Staying Current in Cold Chain Management

SERVICES FOR. Devices and Combination Products

PHARMACEUTICAL DEVELOPMENT

SPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT

Guidance for Industry ANDAs: Stability Testing of Drug Substances and Products

ICH guideline Q8, Q9 and Q10 - questions and answers volume 4

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY VERSION 7

Evaluating Current Practices in Shelf Life Estimation

Quality Risk Management

REACH and Safety Data Sheets

ELEMENTAL IMPURITY ANALYSIS IN REGULATED PHARMACEUTICAL LABORATORIES. A Primer

STABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS

Annex 6. Guidance on variations to a prequalified product dossier. Preface

FDA and the Compounding Pharmacy

Safety Data Sheet Avesta Neutralization Agent 502

Introduction to Enteris BioPharma

Blood, Plasma, and Cellular Blood Components INTRODUCTION

Transcription:

Technical Brief Extractables and Leachables for Filters, Bags and Other Components Used in Biopharmaceutical Manufacturing Processes OBJECTIVE This Technical Brief provides an overview on how to approach extractables and leachables evaluation for filters, bags and other components used in biopharmaceutical manufacturing processes including Single-Use applications. The Technical Brief is based on our best understanding of regulatory guidance as well as industry practice. It aims at assisting our world-wide customers in fulfilling their responsibilities with respect to extractables and leachables evaluation. The Technical Brief contains the following: Background Regulatory and industry guidance Risk assessment Millipore s approach Frequently asked questions and answers References Fluid Adsorption Contact Surfaces Leachables Extractables Gas permeation BACKGROUND Filters, bags and other components constructed of plastic and/or elastomeric materials are extensively used in the biopharmaceutical manufacturing processes. As a result of their contact with a drug product, they can potentially leach compounds into the drug product. The objective of the extractables and leachables evaluation is to demonstrate that these product-contact materials will not adversely affect the product s safety. Absorption Figure 1. Possible interactions between fluid and its contact surfaces Extractables refers to compounds that can be extracted from plastic or elastomeric materials in solvents of different physicochemical properties under aggressive conditions; while leachables refers to compounds that leach from the plastic or elastomeric materials into actual drug product under normal use conditions. Because leachables are expected to be a subset of extractables, the extractables profile should be predetermined.

REGULATORY AND INDUSTRY GUIDANCE GMP guidelines around the world require that surfaces which contact drug products shall not be reactive, additive, or absorptive so as to alter the safety or efficacy of the drug product beyond the official or other established requirements ( Ref. 1-3). Specific to the filters, in the Guidance for Industry for the Submission Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products, the US Food and Drug Administration (FDA) requires users to submit extractables information as part of an evaluation of the impact of the filter on the product (Ref. 4). European Union (EU), in GMP Annex 1, Manufacture of Sterile Medicinal Products, states that the filter should not affect the product by removal of ingredients from it or release of substances into it (Ref. 5). Parenteral Drug Association (PDA) Technical Report No. 26 provides details on how to approach the extractables and leachables validation for liquid sterilization filtration (Ref. 6). It outlines the scope of the extractables studies as quantitation of the total amount and identification of the extractables. Within the Technical Report No. 26, PDA recommends users not only obtaining the extractables information from filter suppliers, but also performing the leachables studies, whenever possible, especially if sterile filtration is the final step in the manufacturing process prior to the filling process. Currently, there are no specific regulatory standards with respect to bags and other Single-Use assembly components. However, if bags are used for final drug product storage, the FDA guidance for container closure systems (Ref. 7) and the European Medicines Evaluation Agency (EMA) guideline on plastic immediate packaging materials (Ref. 8) can be used as references. Both guidelines recommend that an extractables study be followed by a leachables study, as well as accompanied by a toxicity evaluation and risk assessment. Please refer to Figure 2 Summary of EMA requirements for plastic immediate packaging materials. In addition, U.S. Pharmacopeia (USP) Chapter <661> Containers and European Pharmacopeia (EP) Chapter 3 Materials and Containers describe the compendia test methods for containers (Ref. 9-10). Figure 2. Summary of EMA requirements for plastic immediate packaging materials Is this Plastic Material as described in European Pharmacopeia? General information(1) Specification(2) Leachables studies(3) leachables, as necessary. The BPSA recommendations focus on a risk assessment-based approach, where the degree of testing and analysis is determined by the relative risk that leachables from a Single-Use component pose to a final drug product. Please refer to Figure 3 Decision Tree for Disposable Manufacturing. Finally, Product Quality Research Institute (PQRI) has recently established safety thresholds and best practices with respect to the extractables and leachables for orally inhaled and nasal drug products (Ref. 12). Based on a statistical analysis of a large number of compounds, the PQRI Leachables and Extractables Working Group sets the safety threshold at 0.15 μg per day, below which no further safety assessment is necessary. It should be noted that this level is considered valid only for high-risk applications such as orally inhaled and nasal spray drug products, and may not General information(1) Specification(2) Leachables studies(3) Extractables studies Toxicological documentation (1) - Chemical name of the material, monomer, additives, etc. (2) - Specification of plastic material. See Validation Guides. (3) - Leachables studies can be omitted if, based on the outcome of the extractables studies, the calculated maximum amount of the individual leachables substance that may be present in the drug product leads to levels demonstrated to be toxicologically safe. be applicable to other forms of drug products such as parenterals that are of significantly lower risks. To address the lack of regulatory guidance for the Single-Use applications, Bio-Process System Alliance (BPSA) has published its recommendations for extractables and leachables testing. BPSA also suggests users obtain the extractables information from suppliers, conduct the toxicity evaluation, as well as quantify and identify the

Decision Tree for Disposable Manufacturing MATERIAL SUITABILITY Exclusively 21CFR 177-189 Cleared Materials USP, <87> and <88> cgmp As Defined by Regulatory Guidelines: What is the proximity to final product, composition of product, contact surface area, time,temperature, pre-treatment steps? Is 21 CFR cleared application in alignment with desired application? Is it a critical application? Perform extractables study to establish targets Perform risk assessment to approve material Toxicology assessment of targets: are compounds known? (Known compounds & concentrations) Do exposure levels exceed guidelines or TTC? Tox database: ICH, IRIS & others Threshold of toxicological concern (TTC) MATERIAL APPROVED Is there an opportunity to change the process? Component/assembly qualification Perform leachables study Can the risk be mitigated, e.g. the application changed QC Is risk too high? Material not acceptable for use Figure 3. Decision Tree for Disposable Manufacturing

RISK ASSESSMENT The first step in an extractables and leachables evaluation is to identify all product-contact materials based on process knowledge. The second step is to perform a risk assessment to determine critical materials that require further information on the extractables and leachables. Multiple factors should be taken into consideration, including but not limited to the following: Chemical compatibility between material and drug product Toxicity of the extractables Contact time Contact temperature Surface area-to-volume ratio (including batch vs. contiunous processing) Proximity of material to final product Dosage form Route of administration A risk factor can be categorized into varying degrees of severity (see Table 1 below), as well as characterized based on the combination of severity and frequency. A numerical value can be assigned to reflect the relative ranking that a risk poses to a drug product (Ref. 13). In applications where the risk is low, it is possible that the risk assessment combined with an evaluation of the extractables information will be sufficient and therefore no further action is required for leachables (Ref. 11). Millipore provides customer consultation in the area of risk assessment based on our extensive knowledge, but ultimately the decision of the type and level of testing rests with drug manufacturers based on their risk assessment analysis and regulatory experience. Table 1. Risk factors and their various degrees of severity in different applications DEGREE OF SEVERITY APPLICATIONS Low Intermediate High Chemical compatibility Compatible Limited Incompatible Toxicity of extractables Non-toxic Toxic at high levels Toxic at low levels Contact time Short Moderate Long Contact temperature Ambient or below Elevated High Surface area-to-volume Low Medium Large Proximity Upstream Downstream Final fill/storage Dosage form Solid Liquid Vapour Route of administration Topical, Oral Ophthalmic, Transdermal Inhalation, Injections MILLIPORE S APPROACH Given the complexity of the extractables and leachables, and the analytical challenges involved, multiple analytical techniques are often employed to yield the most comprehensive information. The intimate knowledge of our raw materials and manufacturing process, combined with our expertise in analytical instrumentation and methodology, allows us to develop and validate analytical methods most suitable for the extractables and leachables testing of our products. To assist customers in fulfilling their validation requirements, Millipore has developed a model solvent, worst-case scenario approach to evaluating extractables. In this approach, a material of interest is extracted in solvent(s) representative of the drug product, under aggressive conditions such as time and temperature. The extractables are quantified for the total amount, identified and linked to the materials that have been shown to be non-toxic per USP Class VI (Ref. 14). Recently, in response to increasing demand, Millipore has developed technical capabilities for evaluating leachables (patent pending). Depending on the test article and drug product formulation, the leachables testing can be developed in the drug product or modified drug product. Applications have been successfully developed on final filtration devices with a wide-range of drug products. Our practice is consistent with regulatory expectations and industry standards, and our laboratory is compliant with quality requirements outlined under cgmp. Please refer to Figure 4 for a summary of the regulatory and industry documentation that is applicable to a Single-Use assembly. Raw materials used by Millipore for product contact meet USP Class VI safety requirements post sterilization (autoclave, steam-in-place and/or gamma irradiation), and the results are published in Validation Guides and Certificates of Quality for the respective product.

EC & EMA GMP Chapter 3, Annex 1, Immediate Packaging ICH GMP Q7,5 FDA GMP 211.65, Filter Validation, Container Closure EP Chapter 6.4,3 USP <661>, <88> PQRI Safety Threshold & Best Practice BPSA EXT & LEA Recommendation PDA Technical Report #26 Figure 4. Overview of regulatory and industry guidelines on Single-Use assembly REFERENCES 1. FDA, Code of Federal Regulations, Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals, Part 211.65, Equipment Construction, 2005 2. European Commission, EUDRALEX Volume 4, Good Manufacturing Practices, Medicinal Products for Human and Veterinary Use, Chapter 3, Premise and Equipment, 2003 3. ICH, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients Q7, 5, Process Equipment, 2000 4. FDA, Guidance for Industry for the Submission Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products, 1994 5. European Commission, EUDRALEX Volume 4, Good Manufacturing Practices, Medicinal Products for Human and Veterinary Use, Annex 1, Manufacture of Sterile Medicinal Products, 2008 6. PDA, Technical Report No. 26, Sterilization Filtration of Liquids, 2008 7. FDA, Guidance for Industry Container Closure Systems for Packaging Human Drugs and Biologics CMC, 1999 8. EMA, Guideline on Plastic Immediate Packaging Materials, 2005 9. U.S. Pharmacopeia, 31-NF26, <661>, Containers, 2008 10. European Pharmacopeia, 6.4, 3, Materials and Containers, 2008 11. BPSA, Recommendations for Extractables and Leachables Testing, 2007-2008 12. PQRI, Safety Thresholds and Best Practices for Extractables and leachables in Orally Inhaled and Nasal Spray Products, 2006 13. The Biopharmaceutical Process Extractables Core Team, Evaluation of Extractables from Product-Contact Surfaces, Biopharm International, December 2002, Page 22 34 14. U.S. Pharmacopeia, 31-NF26, <88>, Biological Reactivity Tests, In Vivo, 2008 www.millipore.com/offices Millipore, Mobius and Advancing Life Science Together are registered trademarks of Millipore Corporation. The M mark are trademarks of Millipore Corporation. Lit No. PB10010000. UP-SBU-09-02302. 2010 Millipore Corporation, Billerica MA, 01821 USA. All rights reserved.

FAQ S When do I need to consider extractables and leachables evaluation? In Millipore s experience, extractables and leachables evaluation usually is performed at a late stage in drug product development and commercialization, when the formulation and process parameters are well established. However, during the early phases, such as pre-clinical trials, it would be prudent to select a material that is compatible with the drug product, and monitor the impact of the extractables and leachables throughout various product development testing. How are model solvents selected to represent my drug product? Model solvents are selected to exhibit similar physical and chemical characteristics to the drug ingredients. Common factors to simulate a drug product include ph, organic solvents and solutes if present at significant concentrations. Contrary to the organic solvents and solutes, inorganic solutes are not considered for modelling as they are known to increase the ionic strength of the solution and thus decrease the extraction capability. Which process condition will affect extractables levels? Extraction is a partition of an extractable compound between the solid phase (filter membrane, film, etc.) and the liquid phase (extraction solution). The extent and the rate of the partition are driven by multiple factors. For example, longer times and higher temperatures typically result in higher levels, and organic solvents yield more extractables than aqueous solutions. Additionally, any thermal, chemical and mechanical stress introduced by sterilization can produce more extractables. On the other hand, flushing prior to processing has been shown to be effective in removing the majority of the extractables. Are there any acceptable levels of extractables and leachables established? Users are expected to establish their own criteria based on the toxicological evaluation and process control. Currently, there are no official extractables and leachables levels established by any regulatory agency, as they are compound dependent. Are leachables a subset of extractables? Yes, they should be a subset of the extractables when the extractables study is well designed in terms of the model solvent(s) and worst-case extraction conditions used. Under such circumstances, the extractables study will reveal all potential leachables that might occur in the drug product, and the leachables study in return will verify the presence or absence of the extractables in the drug product. I have requested an extractables study done in the past. Shall I consider a leachables study now? It depends. Based on regulatory and industry guidance, users shall consider a leachables study if, upon risk assessment, a product-contact material may introduce leachables at levels that may alter the safety of the drug product. Specific examples that may require further leachables evaluation include final sterilization filtration, final container/closure system, high-risk applications such as inhalation and nasal spray products, etc. Who is responsible for generating leachables information if deemed necessary? You, as a user. It has been an industry practice for vendors like Millipore to provide extractables information, and users to conduct leachables testing as deemed necessary. For many years Millipore has been successful in generating the extractables information using the model solvent and worst-case scenario approach. Recently, we have also developed a leachables study capability. What information will be generated during a leachables study? While the extractables study offers information about the total quantity and identity of the extractables, the leachables study will confirm the presence/absence of those extractables in the (modified) drug product. Because the extractables study generates valuable information that is not attainable in the leachables study, and vice versa, one cannot replace the other. How does Millipore compare to the other vendors in the industry in the area of extractables and leachables validation? Our in-depth technical capabilities, combined with our extensive knowledge about customers processes and regulatory expectations, allow us to develop the most suitable analytical methods for the extractables and leachables analysis. In addition, we have intimate knowledge of raw materials and manufacturing processes of our products that assists us in extractables and leachables identification, which can be analytically challenging to a third-party. Finally, our practice matches regulatory expectations and industry standards and our laboratory complies with quality requirements outlined under cgmp.