ASYNCHRONOUS SERIAL CONVERTER RS485/USB S107USB/K107USB

Similar documents
ZC-24DO CANopen I/O Module: 24 Digital Outputs

Product EASY-USB. Description. USB - UART TTL converter. Seneca s.r.l. support@seneca.it sales@seneca.it. Series of product. Pag.

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

TX OPEN RS232/485 module

IntesisBox Modbus Server Fidelio IP

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Waveguide Access Point WGA631. Product Guide

XBee USB Adapter Board (#32400)

Digital input modules

USB to RS-422/485 Serial Adapter

By4750. USB Serial Converter (RS232 RS485)

USA MOBILITY CABLE CONNECTION AND SOFTWARE DRIVER INSTALLATION INSTRUCTIONS. For. Unication M90 Device USB To RS232 Adapter TABLE OF CONTENTS

OPT SERIAL TO FIBER OPTIC CONVERTER

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

Universal Serial Bus (USB) to DH-485 Interface Converter

User Manual Revision English

TX2123 RS485 TO ETHERNET ADAPTOR

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

IntesisBox KNX Modbus RTU master

User manual Compact Web PLC WP240 series IEC-line

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

IntesisBox KNX Modbus TCP master

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

connecdim Gateway G1 Ethernet TCP/IP to DALI

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

Z-TWS4. Multifunction Straton / LINUX Controller.

48-B-5-08-KIT 5-Wire Resistive Controller (USB) Specification Guide

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

MINI MCR-SL-R-UI(-SP)

QSE-CI-NWK-E Control Interface

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

IntesisBox ASCII Server - LON

PCS0100en Persy Control Services B.V. Netherlands

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

IntesisBox KNX LG Air Conditioning

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

USER MANUAL Z-3A0. Via Germania, Z.I. CAMIN PADOVA ITALY. Via Svizzera, Z.I. CAMIN PADOVA ITALY

IntesisBox KNX - LON

Redundancy Module QUINT-DIODE/40

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

T0118 T2118 T3118. Instruction Manual

SYSTEM DESCRIPTION Termination Boards

400 Series - Mini USB Buccaneer

USB PC Adapter V4 Configuration

Advanced Data Capture and Control Systems

User Manual (DA-70155)

=============================== WARNING

User Manual Revision English

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

Standard Buccaneer - USB

IntesisBox Modbus Server SAMSUNG Air Conditioners

1. SAFETY INFORMATION

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

RS232/DB9 An RS232 to TTL Level Converter

NC-12 Modbus Application

1-Port R422/485 Serial PCIe Card

User Manual Revision English

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Modbus Server SAMSUNG Air Conditioners

USB-RS232 Converter USB-RS422/485 Converter. User's Manual

Product and functional description

3500/93 System Display

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

ATA TO IDE INTERFACE PC CARD DRIVES

KNX Panasonic Air Conditioners

RS485 Adapters. User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 SC485 USB485B USB485 USB485-ISO

How To Use A Ds340 (Dsp)

CompactRIO crio-9052

2/4/8 Port USB to Serial Adapter Hub with COM Retention

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

Current Monitoring Kit QUICK START GUIDE

LwLVision-USB 2.0. Installation Guide

Duct Humidity Transmitter

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Current Monitoring Kit

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

User Manual Revision English

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Safety Precautions WARNINGS

Application/Connection Examples

User Manual Revision English

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Power Supply and Cabling Options. SmartTrak 100/101/140

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers

USB TO SERIAL CONVERTER

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

485USBTB-2W & 485USBTB-4W

Transcription:

ASYNCHRONOUS SERIAL CONVERTER RS485/USB S107USB/K107USB GENERAL DESCRIPTION The S107USB and K107USB instruments, represent an interface able to implement an asynchronous RS485 serial port, by using an USB port present on the PC. Thanks to the provided driver, the serial interface is considered by the operating system as a standard serial port; so the use of the product is directly allowed through any software able to communicate with the standard serial ports of the operating system (COM1, COM2, etc). The electrical insulation between the RS485 and the USB ports, allows to remove many problems of electrical noise which may occur when the connected equipment is very far from the PC. GENERAL FEATURES Usable in Windows 98, 2000 and XP Environments. Usable in Linux Environment with Kernel 2.4.20 or later, for which the direct support exists. Compatible with 1.1 and 2.0 USB standard port. Insulation between USB and RS485: 1500 V. Max Consumption: 60 ma. Power Supply provided from the USB port of the PC. Terminator of RS485 line, settable through an external bridge. Baudrate: 1200 bps)115200 bps. RS485 Serial communication through MODBUS RTU protocol, 32 nodes max. Possibility of multiple connection of more S107USB or K107USB to the same PC. Three leds to view the status of the module s activity. Accessories: CD with driver. USB connection cable: USB A and MINI USB B connectors. RS485 Connections of S107USB: removable 5-way screw terminals. RS485 Connections of K107USB: Spring terminals, Conductor Section: 0.2..2.5 mm 2, Wire stripping: 8 mm. Environmental conditions: Temperature: -20..65 C. Humidity: 10%..90% non-condensing. Installation Category: II. Pollution Degree 2. Storage Temperature: -40..85 C Protection Index: IP20 Weight, Dimensions: Standards: TECHNICAL SPECIFICATIONS S107USB: 24 g, 40 x 48 x 20,17 mm K107USB: 43 g, 6,2 x 93,1 x 102,5 mm EN61000-6-4/2002 (electromagnetic emission, industrial environment) EN61000-6-2/2005 (electromagnetic immunity, industrial environment) EN61010-1/2001 (safety). INSTALLATION RULES S107USB INSTALLATION RULES For S107USB module there are not particular warnigs, we only advise to use screened cables for the RS485 line in case of long connections or noisy environments (refer to Electrical Connections section). Pagina 17 of 22

K107USB INSTALLATION RULES This module has been designed for mounting on a DIN 46277 rail. Assembly in vertical position is recommended in order to increase the module's ventilation, and no raceways or other objects that compromise aeration must be positioned in the vicinity. Do not position the module above equipment that generates heat; we recommend positioning the module in the lower part of the control panel or container compartment. Inserting the module in the rail Removing the module from the rail 1) Attach the module in the upper part of the rail. 2) Press the module downwards. 1) Apply leverage using a screwdriver (as shown in the figure). 2) Rotate the module upwards. In case of long connections or noisy environments, it is advisable to use screened cables for the RS485 line (refer to Electrical Connections section). ELECTRICAL CONNECTIONS S107USB ELECTRICAL CONNECTIONS The following figure shows the electrical connections for S107USB module. By inserting an external bridge between T1 and T2 terminals, the terminator of the RS485 line is inserted. In case of long connections or noisy environments, it is advisable to use screened cables for the RS485 line. Pagina 18 of 22

K107USB ELECTRICAL CONNECTIONS The following figure shows the electrical connections for K107USB module. By inserting an external bridge between T1 and T2 terminals, the terminator of the RS485 line is inserted. In case of long connections or noisy environments, it is advisable to use screened cables for the RS485 line. Terminals Connections The module has been designed for spring-type terminal electrical connections. Proceed as follows to make the connections: 1 - Strip the cables by 0.8 mm 2 - Insert a screwdriver in the square hole and press it until the cable lock spring opens. 3 - Insert the cable in the round hole. 4 - Remove the screwdriver and make sure that the cable is tightly fastened in the terminal. Pagina 19 of 22

LEDS SIGNALLING Both the modules have three leds which allow to visualize the status of the module s activity. LEDS POSITION ON S107USB On S107USB module, the leds are positioned on the following way: LEDS POSITION ON K107USB On K107USB module, the leds are positioned on the following way: LEDS MEANING On both modules the leds are identified with the same name and have the following meaning: NAME COLOUR MEANING POWER Yellow If it is lighted, it indicates that the instrument is correctly supplied. Rx Red It lights when the module receives data through the RS485 port. Tx Red It lights when the module transmits data through the RS485 port. Pagina 20 of 22

PROBLEMS SOLVING For any problems with the converter, verify the following points: PROBLEM The POWER Led does not light The Rx Led is steady on The received data are not correct VERIFY Verify that the USB port of the PC provides the 5 V which are necessary to supply the module. Verify that the RS485 cables have not been swapped. Verify the communication speed. DRIVER INSTALLATION The CD containing the instrument s driver is provided to the user. In this section the installation procedure of the driver will be briefly described. It is necessary to specify that the installation in Linux (with Kernel 2.4.20 or later) environments is automatic and does not need the CD with the driver. The standard serial port of the PC which identifies the device is the following: /dev/ttyusb0. As regards Windows operating systems, it is important to underline that the procedure is divided into two phases which are both fundamental for the final use of the instrument. On the first phase, the driver of the out-and-out serial converter is installed. By the second phase instead the virtual driver will be installed: this will allow to use the peripheral as a standard serial port of the operating system. If case of use of Windows 2000, these two phases are identical and are performed step by step: the user has only to follow the guided procedure; instead in Windows 1998 the second phase is automatically managed by the operating system without any further dialogue with the user. In Windows XP the two phases are performed very quickly by the operating system if it the CD with the drivers has been inserted. For the correct installation it is important to insert the CD with the driver and connect the device to the PC already turned on, so that the operating system may automatically detect the presence of the device. At this point the the user has only to follow the guided installation. VISUALIZATION OF THE VIRTUAL COM PORT At the end of the installation, it is possibile to view the name which has been assigned to the virtual serial port associated to the used S107USB or K107USB device. For example on the following Device Manager panel, it has been identified as COM7: Pagina 21 of 22

SENECA s.r.l. Via Germania, 34-35127 Z.I. CAMIN - PADOVA - ITALY Tel. +39.049.8705355-8705359 Fax +39.049.8706287 e-mail: info@seneca.it www.seneca.it Pagina 22 of 22