Update. Rick Kutcipal, President, SCSI Trade Association Greg McSorley, Vice President, SCSI Trade Association

Similar documents
SAS: The Emerging Storage Fabric. Marty Czekalski President, SCSI Trade Association

SCSI Standards and Technology Update: SAS and SCSI Express

PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems

PCI Express IO Virtualization Overview

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

PCI Express Impact on Storage Architectures and Future Data Centers

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation

PCI Express and Storage. Ron Emerick, Sun Microsystems

SAS and SATA Combine to Change the Storage Market

Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

Storage Architectures. Ron Emerick, Oracle Corporation

BCDVideo TM offers HP's full portfolio of SAS drives meeting all these demands.

Data Center Convergence. Ahmad Zamer, Brocade

NVM Express TM Infrastructure - Exploring Data Center PCIe Topologies

UCS M-Series Modular Servers

PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering

How it can benefit your enterprise. Dejan Kocic Hitachi Data Systems (HDS)

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

Quick Reference Guide High Speed Input/Output Solutions

Solid State Storage in a Hard Disk Package. Brian McKean, LSI Corporation

Serial ATA and Serial Attached SCSI technologies

How it can benefit your enterprise. Dejan Kocic Netapp

Serial ATA technology

The Transition to PCI Express* for Client SSDs

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

Fibre Channel Disk Storage System Interface Speed Roadmap

Accelerating Applications and File Systems with Solid State Storage. Jacob Farmer, Cambridge Computer

Best Practice and Deployment of the Network for iscsi, NAS and DAS in the Data Center

Next Generation Storage Networking for Next Generation Data Centers

Storage is in Our DNA. Industry-leading 12Gb/s and 6Gb/s Storage Solutions RAID Adapters, Host Bus Adapters, and SAS Expander

How To Write On A Flash Memory Flash Memory (Mlc) On A Solid State Drive (Samsung)

The ABC of Direct Attach Cables

How To Test Nvm Express On A Microsoft I7-3770S (I7) And I7 (I5) Ios 2 (I3) (I2) (Sas) (X86) (Amd)

Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.

6Gb SAS Host Bus Adapter Product Guide

Sujee Maniyam, ElephantScale

Serial ATA in Servers and Networked Storage

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

QuickSpecs. What's New Dual Port SFF 10K and 15K SAS drives Dual Port 3.5" 15K SAS drives. HP SAS Drives (Servers) Overview

Oracle Virtual Networking Overview and Frequently Asked Questions March 26, 2013

Elasticsearch on Cisco Unified Computing System: Optimizing your UCS infrastructure for Elasticsearch s analytics software stack

Redundancy in enterprise storage networks using dual-domain SAS configurations

Intel RAID SSD Cache Controller RCS25ZB040

The Benefit of Migrating from 4Gb to 8Gb Fibre Channel

SNIA Solid State Storage Performance Test Specification. Easen Ho CTO, Calypso Systems, Inc.

An Introduction to Storage Management. Raymond A. Clarke, Oracle

SSD and Deduplication The End of Disk?

Switched SAS. Sharable, Scalable SAS Infrastructure. Terry Gibbons, Director Software Planning and Strategy, LSI Corporation.

SATA Evolves SATA Specification v3.2 FMS 2013

2 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card w/ 2 msata Slots and HyperDuo SSD Tiering

PCI Express Overview. And, by the way, they need to do it in less time.

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

The Evolution of Solid State Storage in Enterprise Servers

White Paper: M.2 SSDs: Aligned for Speed. Comparing SSD form factors, interfaces, and software support

The Why and How of SSD Performance Benchmarking. Esther Spanjer, SMART Modular Easen Ho, Calypso Systems

PCI Express Supersedes SAS and SATA in Storage

Data Center Storage... Spend Less, Deliver More. Hubbert Smith, LSI

4 Port PCI Express 2.0 SATA III 6Gbps RAID Controller Card with HyperDuo SSD Tiering

LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE. Matt Kixmoeller, Pure Storage

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide

IDE/ATA Interface. Objectives. IDE Interface. IDE Interface

Cisco SmartPlay Select. Cisco Global Data Center Promotional Program

Writing Storage RFP s in John Webster, Evaluator Group

Models 300GB SAS 15K rpm 6Gb/s 3.5" HDD HP 900GB SAS 10K SFF HDD HP 1.2TB SAS 10K SFF HDD

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

Visions for Ethernet Connected Drives. Vice President, Dell Oro Group March 25, 2015

SCSI The Protocol for all Storage Architectures

QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview

HP 8Gb PCIe FC HBAs Overview

Cloud Data Management Interface (CDMI) The Cloud Storage Standard. Mark Carlson, SNIA TC and Oracle Chair, SNIA Cloud Storage TWG

SummitStack in the Data Center

QuickSpecs. Models. HP StorageWorks Modular Smart Array 50 Enclosure. HP StorageWorks Modular Smart Array 50 Enclosure. Overview

Introduction to PCI Express Positioning Information

10GBASE T for Broad 10_Gigabit Adoption in the Data Center

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Object Storage A New Architectural Partitioning In Storage

VDI Optimization Real World Learnings. Russ Fellows, Evaluator Group

Vendor Update Intel 49 th IDC HPC User Forum. Mike Lafferty HPC Marketing Intel Americas Corp.

QuickSpecs. HP SAS Enterprise and SAS Midline Hard Drives Overview

The PCIe solution from ExaSAN

HP StorageWorks MPX200 Simplified Cost-Effective Virtualization Deployment

Extending PCIe NVMe Storage to Client. John Carroll Intel Corporation. Flash Memory Summit 2015 Santa Clara, CA 1

Six Sigma Performance Analysis for SAN. Dan Iacono, HP

Understanding PCI Bus, PCI-Express and In finiband Architecture

Data Center Transformation. Russ Fellows, Managing Partner Evaluator Group Inc.

Scale and Availability Considerations for Cluster File Systems. David Noy, Symantec Corporation

SCSI vs. Fibre Channel White Paper

Enterprise SSD Interface Comparisons

Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3

SCSI Security Nuts and Bolts. Ralph Weber, ENDL Texas

Intel Server Chassis P4304XXSHCN/P4304XXSFCN/P4000XXSFDR

Computer buses and interfaces

VTrak SATA RAID Storage System

FIBRE CHANNEL OVER ETHERNET

SATA 6G PCIe Card User Manual Model: UGT-ST622

Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s

SAN Conceptual and Design Basics

Transcription:

SCSI PRESENTATION Standards TITLE and GOES Technology HERE Update Rick Kutcipal, President, SCSI Trade Association Greg McSorley, Vice President, SCSI Trade Association

SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies and individual members may use this material in presentations and literature under the following conditions: Any slide or slides used must be reproduced in their entirety without modification The SNIA must be acknowledged as the source of any material used in the body of any document containing material from these presentations. This presentation is a project of the SNIA Education Committee. Neither the author nor the presenter is an attorney and nothing in this presentation is intended to be, or should be construed as legal advice or an opinion of counsel. If you need legal advice or a legal opinion please contact your attorney. The information presented herein represents the author's personal opinion and current understanding of the relevant issues involved. The author, the presenter, and the SNIA do not assume any responsibility or liability for damages arising out of any reliance on or use of this information. NO WARRANTIES, EXPRESS OR IMPLIED. USE AT YOUR OWN RISK. 2

Abstract SCSI continues to be the backbone of enterprise storage deployments and continues to rapidly evolve by adding new features, capabilities, and performance enhancements. This presentation includes an up-to-the-minute recap of the latest additions to the SAS standard and roadmaps, the status of 12Gb/s SAS deployment, advanced connectivity solutions, MultiLink SAS, and 24Gb/s SAS development. Presenters will also provide updates on new SCSI features such as Storage Intelligence and Zoned Block Commands (ZBC) for shingled magnetic recording. 3

12Gb/s SAS New SCSI Features Advanced Connectivity MultiLink SAS and U.2 24Gb/s SAS 4

SAS Spans the Storage Spectrum SAS Fabrics Direct Attach Storage External Storage HDD/SSD SAS Expanders SAS Switches Port Multiplexers *ROC = RAID on a Chip HBA = Host Bus Adapter Controllers/ROCs/HBAs* SDS HBAs Expanders Storage Blades NAS/SAN Heads Native SAS Connect Controllers/ROCs/HBAs* Expanders SAS/SATA Bridges SAS is the Universal Storage Interface SAS SSDs SATA SSDs SAS HDDs SATA HDDs Near-Line SAS HDDs 5

SAS Technology Roadmap First Plugfest (leading edge) 24Gb/s SAS 12Gb/s SAS 6Gb/s SAS 3Gb/s SAS First End-User Products (approximately 12 18 months later) 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 Source: SCSI Trade Association Aug 2015 6

12Gb/s SAS (Protocol Layer) 12Gb/s SAS Enabled the Intel Grantley Server Processor Launch Consists of SPL-2/3 and SAS-3 SPL-2 Published 3/2013 Transmitter Training Enhanced Power Control SPL-3 Published 11/2014 Persistent Connections Expander Forced Normal Completion of Connections Largely SSD Enhancements 7

Shingled Magnetic Recording Drive Managed Drive autonomously hides all SMR issues Workloads can affect performance Host Managed New device type Extensions to ATA and SCSI command sets (ZAC & ZBC) Sequential writes are required Host Aware Available Today Superset of Drive Managed and Host Managed Extensions to ATA and SCSI command sets (ZAC & ZBC) Sequential writes are preferred ZBC & ZAC Expected to Be Complete by the End of 2015 8

12Gb/s SAS (PHY Layer) SAS-2.1 Published 11/2011 Managed connectivity Converged high-density connectivity Mini-SAS HD SFF-8644 (external connector) SFF-8643 (internal connector) Active copper support Optical support SAS-3 Published 10/2014 12 Gb/s SAS interface Transmitter training x4 backplane connector Optical Mini-SAS HD connector 9

SAS Advanced Connectivity Objectives Simplify Cable & Connector Options 2X density improvement Provide Managed Connectivity Standards Active copper solution to 20m Optical solution to 100m Supports 6Gb/s,12Gb/s & 24 Gb/s SAS Deployments SAS-2.1 standardizes OOB for active cables Supply power here for active cabling Internal similar to external Passive, Active Copper, and Optical use same connector Cable provides active component for optical or copper Mini-SAS HD connectors courtesy: Project T10/2125-D Revision 04 17 September 2009, ANSI SAS-2.1 10

Advanced Connectivity: Managed Cables New in SAS-2.1, Fully Deployed in SAS-3 OOB (Out of Band) Method of Controlling the Interface EEPROM (or microprocessor) in the Cable End Communicates Via I 2 C to the System Enables Support For Passive Cu, Active Cu & Active Optical Cables From a Single HBA EEPROM EEPROM 11

SAS External Cabling Solutions 100+ meters (optical) SFF-8644 (Mini SAS HD) SFF-8685 (QSFP14) Intermateable Intermateable SFF-8674 (Mini SAS HD) SFF-8665 (QSFP28) SFF-8644 (Mini SAS HD) Intermateable SFF-8674 (Mini SAS HD) 20 meters (active copper) SFF-8685 (QSFP14) Intermateable SFF-8665 (QSFP28) SFF-8088 (Mini SAS) 6 meters (passive copper) SFF-8644 (Mini SAS HD) SFF-8685 (QSFP14) Intermateable Intermateable SFF-8674 (Mini SAS HD) SFF-8665 (QSFP28) SFF-8470 SFF-8088 (Mini SAS) * Unmanaged SAS Connectivity Management SAS-1 / SAS1.1 SAS-2 SAS-2.1 SAS-3 SAS-4 * SFF-8088 passive copper up to 10m Source: SCSI Trade Association Aug 2015 12

SAS Internal Cabling Solutions SFF-8621 (MiniLink) SFF-8655 (Slim SAS) SFF-8673 (Mini SAS HD) 1m (passive copper) (Provides recommended pinouts to bridge from previous connectors to SAS-4 connectors) SFF-8643 (Mini SAS HD) SFF-8087 (Mini SAS) SAS-1 / SAS1.1 SAS-2 SAS-2.1 SAS-3 SAS-4 Source: SCSI Trade Association Aug 2015 13

SAS Device to Mid-Plane Interconnects Multi-Function (4-Port I/O) SFF-8638 SFF-8639 (aka U.2) Two 2x ports at up to 48Gb/s each One 4x port at up to 96Gb/s Four 1x ports at up to 24Gb/s each Two 2x ports at up to 24Gb/s each One 4x port at up to 48Gb/s Four 1x ports at up to 12Gb/s each MultiLink SAS TM (4-Port I/O) SFF-8640 SFF-8630 Two 2x ports at up to 48Gb/s each One 4x port at up to 96Gb/s Four 1x ports at up to 24Gb/s each Two 2x ports at up to 24Gb/s each One 4x port at up to 48Gb/s Four 1x ports at up to 12Gb/s each Standard Dual-Port (2-Port I/O) SFF-8681 SFF-8680 SFF-8482 Two 1x ports at up to 3Gb/s each One 1x port at up to 3Gb/s Two 1x ports at up to 24Gb/s each One 2x port at up to 48Gb/s Two 1x ports at up to 12Gb/s each One 2x port at up to 24Gb/s Note: Data rates shown will double when full-duplexed. Source: SCSI Trade Association Aug 2015 14

U.2 Components (formerly Express Bay) 25W Power Cooling Multifunction Connector Accessibility / Serviceability Traditional Drive Form Factor 15

U.2 U.2 Up to 25 Watts For both SAS and PCIe SFF-8639 connector PCI-SIG electrical specification Objectives Preserve the enterprise storage experience for PCIe storage Meet SSD performance demands Serviceable, hot-pluggable Express Bay opens up new possibilities 16

SAS Connector Compatibility SATA 22 Pins SATA MultiLink SAS TM SFF-8630 43 Pins SATA SAS MultiLink SAS TM 2 SAS SFF-8680 29 Pins SATA SAS MultiLink SAS TM 1 1 Max two links operational 2 Four links operational 3 Two or four links operational depending on host provisioning Multifunction SFF-8639 68 Pins SATA SAS MultiLink SAS TM 3 PCIe 17

U.2 Summary Preserves the Enterprise Storage Experience for PCI Express Storage Meets SSD Performance Demands with PCIe, SAS, or SATA Serviceable, Accessible Bay Offers Configurability 18

24Gb/s SAS Objectives Double the Effective Bandwidth of 12Gb/s SAS Backwards Compatibility Support for two generations of backward compatibility Leverage existing ecosystem (tools, test equipment) Preserve the Existing SAS Value Proposition Reliability Robust Error Handling Scalability Scalable to 1,000s of Devices Flexibility SAS Infrastructure Supports SAS & SATA Devices Serviceability Surprise Add/Remove Media & Cables Manageability Storage Management Built into the Standard Align with a 2019 Platform Launch 19

24Gb/s SAS Characteristics 22.5 Gbaud Efficient Encoding 128b/130b 20 Bit Forward Error Correction Targeting a 30dB channel Protocol & Block Level Enhancements SMP priorities Storage Intelligence Zone Block commands In Flight Channel model (leveraging OIF-CEI & IEEE) SAS-4 transmitter training algorithm (continuous adaptation) Fairness enhancements 20

Summary SCSI Standards Continue to Evolve & Adapt New Features for Performance & Efficiency Being Added Proven Stable Protocol Follow T10 Activities (www.t10.org) Standards updates Meeting schedules Discussions Stay Up-To-Date with the SCSI Trade Association (http://www.scsita.org) Press releases Articles 21

Attribution & Feedback The SNIA Education Committee thanks the following Individuals for their contributions to this Tutorial. Authorship History Additional Contributors Rick Kutcipal Greg McSorley Updates: Please send any questions or comments regarding this SNIA Tutorial to tracktutorials@snia.org 22