STERILE SPINAL IMPLANT: RATIONALE AND EVIDENCE



Similar documents
Best Practices for Loaner Surgical Instruments

National Decontamination Guidance on Loan Medical Devices (Reusable): Roles & Responsibilities GUID 5002

Sterilization of Surgical Implants: Did You Know

Getting a Handle on Loaner Instrumentation

Infection Control in the Dental Practice through Proper Sterilization

By Natalia Wilson, MD, MPH

t-doc Instrument Intelligence take command of your operations Always with you

(English) NEXUS SPINE SPACER SYSTEM

BC Children s Hospital Mistake-Proofing Equipment Reprocessing. Laurence Bayzand Janice Penner Sue Fuller Blamey

RFID Survives Sterilization to Deliver Medical Device Tracking Solution

(Samuel LAW Tat Hong) (COM CSSD NTWC)

Supplier Quality Assurance

Quality Management System Manual

FINAL DOCUMENT. Global Harmonization Task Force. Title: Label and Instructions for Use for Medical Devices

Sterilization of Dental Instruments Dental Clinical Guidance

t-doc Instrument Intelligence take command of your operations

SAMBA Screw System INSTRUCTIONS FOR USE TABLE OF CONTENTS. Description. Indications. Contraindications. Warnings. Potential Adverse Events

Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR)

Clinical Guideline for: Aseptic Technique

Guidelines for the Safe Transport of Infectious Substances and Diagnostic Specimens

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Pharmaceutical Wholesaler Site Inspection Checklist

The design planning implications of HTM 01-05: decontamination in primary care dental practices

THE BASICS OF PACKAGING

USP <797> Cleanroom Design and Environmental Monitoring. Andrew King, USP <797> Specialist CETA Member RCCP-SC

FAQ: Unique Device Identification Final Rule

Good Manufacturing Practices for the Production of Packaging Inks formulated for use on the non food contact surfaces of food packaging and articles

INFECTION CONTROL SURVEYOR WORKSHEET

1/22/2012. When is it a good time to learn about sterile processing in your facility? Continuing Education Contact Hours. Learning Objectives

Improving the Quality of Surgical Trays. By: Stephen M. Kovach

INTRODUCTION TO MACHINE-VISION INSPECTION

Total Shoulder Arthroplasty

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

New Guidelines on Good Distribution Practice of Medicinal Products for Human Use (2013/C 68/01)

Health & Safety Policy and Procedure MEDICAL DEVICES IN DENTAL POLICY. Version: v1. Date approved: pending

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

Community Equipment Loan Stores Guidance on Decontamination BULLETIN

2. JOB PURPOSE To work as a team member in providing a high quality decontamination/sterilisation service for theatres, wards and departments.

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

DISINFECTION & STERILIZATION INFECTION CONTROL GUIDELINES SECTION 4 QUALITY MANAGEMENT IN STERILIZIATION

Aviation Suppliers Association Quality System Standard. ASA-100 Revision 3.5

Orthopaedic Spine Center. Anterior Cervical Discectomy and Fusion (ACDF) Normal Discs

Draft guidance for registered pharmacies preparing unlicensed medicines

Centre for Healthcare Related Infection Surveillance and Prevention & Tuberculosis Control

Supplier Quality Agreements

Standard laryngoscope blade assemblies Directions for use

Health and safety practices for health-care personnel and waste workers

Content Sheet 5-1: Overview of Sample Management

SATO Healthcare Solutions

Self-Audit Checklist

Quality Risk Management - The Medical Device Experience. Niamh Nolan Principal Design Assurance Engineer Boston Scientific

Chapter 3. OR Inventory Optimization

GUIDELINES PROCEDURES FOR THE VISUAL INSPECTION OF LOTS OF CANNED FOODS FOR UNACCEPTABLE 1 DEFECTS

Medical Device Alert. Device All metal-on-metal (MoM) hip replacements. Action by. CAS deadlines. Ref: MDA/2012/036 Issued: 25 June 2012 at 11:00

Biohazardous, Medical & Biological Waste Guidance Chart

SATO Healthcare Solutions

Vendor Requirements and Compliances

Lentur Cable System. Surgical Technique

Appendix H IBC Managing Biohazardous Waste SOP

Meet Global Food Safety Standards and Increase Productivity and Profitability

CENTRAL SERVICE REGULATIONS FOR AMBULATORY SURGERY CENTERS

Errors in the Operating Room. Patrick E. Voight RN BSN MSA CNOR President Association of perioperative Registered Nurses (AORN)

Leila Kakko Tampere University of Applied science TRADITIONAL FOOD IN COMBATING FOODBORNE PATHOGENS 2011

Technology Breakthrough in Spinal Implants (Technical Insights)

UTILIZAÇÃO DA LEAN METODOLOGIA. Desmistificando Aplicações Reais Para CME. Apresentado por John Kimsey

Hazardous Substances and New Organisms Act 1996

Company background and. portfolio overview

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE PHARMACY PROGRAM FOR UTILIZATION OF UNUSED PRESCRIPTION DRUGS

Position Paper (II) Healthcare Provider Advisory Council Implementation in hospitals hindered by bar code symbol issues

ICD-10-CM Official Guidelines for Coding and Reporting

Policy Document Control Page

ADVANTAGES OF RFID FOR WARRANTY MANAGEMENT AND/OR MAINTENANCE

Medical Software Development. International standards requirements and practice

AS9100 Quality Manual

Health Service Executive Code of Practice for Decontamination of Reusable Invasive Medical Devices

Unique Device Identification System; Final Rule

THE VALSPAR CORPORATION

MEDICAL DEVICE GUIDANCE

Bogue Machine Company, Inc. Business Instruction

A guide to the decontamination of reusable surgical instruments STATUS IN WALES APPLIES

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

Information for the Patient About Surgical

Statement BAR CODE LABEL REQUIREMENTS FOR HUMAN DRUG AND BIOLOGIC PRODUCTS

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

VENDOR EDI MANUAL SPORTSMAN S GUIDE (SG)

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Risk Assessment for Medical Devices. Linda Braddon, Ph.D. Bring your medical device to market faster 1

HAZARDOUS WASTE MANAGEMENT AT HEALTHCARE FACILITIES

Guide to the European Union

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

INSTITUTIONAL POLICY AND PROCEDURE (IPP)

Aviation Suppliers Association Quality System Standard. ASA-100 Revision 4.0

Are you protected? PharmaShield. The Evolution of Generics

First aid guidance note

Transcription:

2 STERILE SPINAL IMPLANT: RATIONALE AND EVIDENCE A safer, easier, cost effective solution for spinal implant management is possible.

IMPLANT REPROCESSING IS ASSOCIATED WITH : FDA REGULATIONS RISKS LIABILITY TRACEABILITY Sterile Spinal Implant: Rationale and Evidence 2

Summary 1. References 4 2. Executive Summary 5 3. Infections 6 4. Risks of Reprocessing 7 Transfer of Liability 8 Lack of Compliance 8 Unproven Cleaning 9 Corrosion 10 Contamination 11 Costs 12 5. A New Generation of Implants 13 No Liability 15 Full Traceability 15 Cost Effectiveness 16 Sterilization Method 16 6. Conclusion 17 3 SPINEART 2014

1. References The following articles are referenced in this document : Implant contamination during spine surgery. Jesse E. Bible, MD, MHSa, Kevin R. O Neill, MDa, Colin G. Crosby, MDa, Jonathan G. Schoenecker, MD, PhDa, Matthew J. McGirt, MDb, Clinton J. Devin, MDa. The Spine Journal 13 (2013) 637 640. Schultz, Janet. Monitoring and Load Release for Implants Sterilized by Steam Within Healthcare Facilities. Managing Infection Control. Jan 2004. MHRA (Regulating Medicines and Medical Devices). Bulletin 2006. The Pandora s Box Dilemma. Reprocessing of Implantable Screws and Plates in Orthopedic Tray Sets. Michelle J. Alfa. Horizons Spring 2012. Single-Use Screws and Plates. Joanna Ford (R&D Officer, SMTL), Graham Yarlett (HSDU Manager, Royal Glamorgan Hospital), Gill Bailey (Contracts Officer, WHS), & Pete Phillips (Director, SMTL) Epub http://www.medidex.com/ research/788-single-use-screws-and-plates.html Process-independent quantitative assessment of residual biological contamination of medical devices reprocessed in washer-disinfectors. Sigler K, Chladkova K, Vacata V, Gebel J, Gaskova D. Folia Microbiol (Praha) :50, 3 ;239-46. 2005. Corrosion of metal orthopaedic implants. Jacobs J, Gilert J, Urban R. J Bone Joint Surg Am.:80,2; 268-82. Scottish Executive. Directorate of Finance. NHS HDL (2007). Queensland Government Department of Health Centre for Healthcare Related Infection Surveillance and Prevention. Reprocessing Screw Banks & other Orthopaedic Implant Sets. September 2013. Sterile Spinal Implant: Rationale and Evidence 4

2. Executive Summary Infection rates in spinal surgery range between 1% and 15%, causing significant patient morbidity and resulting in important additional costs to the hospital 1. Working with devices that are clean and free of contamination is paramount to prevent surgical wound infections. However, a rapid look at the current practice by most implant vendors in the US calls into question the general adherence to this basic requirement. The concerns raised by the use of reprocessed implants have motivated countries such as Australia and Scotland to specifically address the problem, recommending the use of single use, presterilized implants. In Scotland, the deadline for the conversion to prepackaged sterile implants was December 31 st, 2007. «[...] Using up old stock would simply prolong what we now recognize as suboptimal clinical practice.» As the Scottish Health Department points out, most orthopedics units use ( ) small orthopedics implants which have been repeatedly reprocessed in racks or trays (...). We suspect many of these devices have been recirculating for many years. Using up old stock would simply prolong what we now recognize as suboptimal clinical practice 2. To ensure safety and compliance, Spineart, a spinal device company with its origin in Switzerland, has offered sterile single packaged barcoded implants for almost 10 years. Using sterile packaged implants is a safer, simpler and cost-effective solution to mitigate the risk of infection. Sterile implants meet compliance requirements, including unwanted transfer of liabilities. [1] Implant contamination during spine surgery. Jesse E. Bible, MD, MHSa, Kevin R. O Neill, MDa, Colin G. Crosby, MDa, Jonathan G. Schoenecker, MD, PhDa, Matthew J. McGirt, MDb, Clinton J. Devin, MDa. The Spine Journal 13 (2013) 637 640. [2] Scottish Executive. Directorate of Finance. NHS HDL (2007). 5 SPINEART 2014

3. Infections Implants are foreign bodies retained within the surgical wound, therefore representing a threat of infection. Implants require particular care in terms of sterilization practice and quality control process. Any microorganisms present on the device at the time of implantation will remain in the system, although infections associated with implants may not be evident for up to a year after procedure. In addition, the placement of an implant often means the removal of tissue, with interruption of blood supply and significant manipulation of the tissues immediately adjacent to the implant, creating an area potentially favorable for microorganisms to multiply, further increasing the risk of infection. Furthermore, because there is interrupted blood supply, antibiotics cannot easily reach the microorganisms that may cause a clinical infection. The cost and risk associated with infection can be mitigated by ensuring appropriate implant sterilization. Often, the infection is not curable with the implant in place and removal may be required, placing an additional risk of severe permanent injury for the patient 3. [3] Schultz,Janet.Monitoring and Load Release for Implants Sterilized by Steam Within Healthcare Facilities. Managing Infection Control. Jan 2004. Sterile Spinal Implant: Rationale and Evidence 6

4. Risks of reprocessing Most often, the single-use spinal implant trays are loaned and delivered as non-sterile, requiring processing to make them ready for use. The lifecycle of an implant has many steps, each of them adding potential risk factor for contamination. The lifecycle of an implant has many steps, each of them adding potential risk factor for contamination. Lifecycle of Reprocessed Implants Reprocessing of implant tray Loaner tray at Vendors Facility Implant tray transferred to hospital Size replenishment in tray Example of rack of reprocessed implants Reprocessing of implant tray Device implanted in OR Verification of sterility 7 SPINEART 2014

The practice used for re-processing (or re-sterilization) of medical implants raises several concerns. Transfer of liability There are a number of legal concerns associated with reprocessed implants. Outside of the United States, the United Kingdom s Medicines and Healthcare Products Regulatory Agency states: The reuse of single-use devices has legal implications: anyone who reprocesses a device intended by the manufacturer for use on a single occasion, bears full responsibility for its safety and effectiveness 4. «[...] anyone who reprocesses a device bears full responsibility for its safety and effectiveness.» No clear guidance is provided to define the term reuse, although the term single-use indicates that reprocess should not take place under any circumstances 5. Lack of compliance Another relevant concern related to reprocessed implants is the lack of traceability. It is not possible to trace back the history of the implants (for example: manufacture date, how many times it has been reprocessed, where and how many times it has been shipped.) If, for example, a device is subjected to a recall, it is not possible for the healthcare provider to know which patient has been implanted with the incriminated batch. Practically, this means that every implanted patient will be reached and monitored, irrespective of the lot number of the implant used on them. It is not possible to trace back how many times it has been reprocessed, where and how many times it has been shipped. [4] MHRA (Regulating Medicines and Medical Devices). Bulletin 2006. [5] Single-Use Screws and Plates. Joanna Ford (R&D Officer, SMTL), Graham Yarlett (HSDU Manager, Royal Glamorgan Hospital), Gill Bailey (Contracts Officer, WHS), & Pete Phillips (Director, SMTL) Epub http://www.medidex.com/ research/788-single-use-screws-and-plates.html Sterile Spinal Implant: Rationale and Evidence 8

Risks of reprocessing Unproven cleaning A significant concern is the ability to properly clean the implants. The racks that hold the implants are not designed to enable optimal cleaning but more to facilitate the selection of the size in the OR. Therefore, when the rack is cleaned through an automated washer, cleaning and rinsing of each individual implant becomes challenging 6. Recent studies documented that, despite sterilization, the endotoxins retain biological activities 7. Biological and chemical residues will retain their immunogenicity after sterilization. Despite sterilization, the endotoxins retain biological activities. Example of tray showing residues post-reprocessing [6] Reprocessing of Implantable Screws and Plates in Orthopedic Tray Sets Michelle J. Alfa. Horizons Spring 2012. [7] S. 9 SPINEART 2014

Risks of reprocessing Corrosion Once an implant arrives to a healthcare facility, it is not possible to know how many times it has been reprocessed. However, repeated sterilization cycles may ultimately have an impact on the surface of the implant. The reprocessing of non-sterile implants involves a certain level of mechanical (abrasion and/or fretting) and electrochemically corrosion (contact with solutions and other metals). Although little research has been published on the topic, there is the possibility that repeated cycles of sterilization already started the corrosion process prior to implantation, thus making metal fracture and subsequent implant failure more likely 8. «[...] repeated sterilization cycles may ultimately have an impact on the surface of the implant.» Figure 1 Figure 2 Figure 3 Microscopic image of a new unprocessed screw. Microscopic image of a screw that has undergone reprocessing on numerous occasions. Magnification of Figure 2. [8] Single-Use Screws and Plates. Joanna Ford (R&D Officer, SMTL), Graham Yarlett (HSDU Manager, Royal Glamorgan Hospital), Gill Bailey (Contracts Officer, WHS), & Pete Phillips (Director, SMTL) Epub http://www.medidex.com/ research/788-single-use-screws-and-plates.html Sterile Spinal Implant: Rationale and Evidence 10

Risks of reprocessing Contamination As previously mentioned, often the implant sets are provided to the healthcare facility on a loaner basis. There is no guideline available for the shipment of the implant sets and often, between surgeries, the sets travel in the car of the sales representative. The implant sets are therefore continuously exposed to hazardous contamination and ultimately the hospital is responsible for the cleanliness and sterility. A recent study based on 105 consecutive surgical cases, has shown that contamination of implants in the OR occurs after the tray is opened. The implant sets are exposed to hazardous contamination and the hospital is responsible for the sterility. Although set coverage significantly reduced the contamination, it does not completely eliminate the risk 9. Example of a cannulated pedicle screw containing bone after reprocessing [9] Implant contamination during spine surgery. Jesse E. Bible, MD, MHSa, Kevin R. O Neill, MDa, Colin G. Crosby, MDa, Jonathan G. Schoenecker, MD, PhDa, Matthew J. McGirt, MDb, Clinton J. Devin, MDa. The Spine Journal 13 (2013) 637 640 11 SPINEART 2014

Risks of reprocessing Costs The costs associated with reprocessing are often hidden and transferred by the vendor to the healthcare facility. The financial cost of the implant sets reprocessing is difficult to estimate as it varies from one center to another. However, the cost of the actual reprocessing is only a part of the financial burden ascribed to the healthcare facility. The implant trays are checked at different stages after reprocessing prior to OR use. This time consuming practice often results in trays returned from the OR for being considered non-compliant. A non-compliant implant set at the time of the surgery may result in important costs in the form of delays and cancellations. Moreover, post-operative infections are considered Never Events by Centers for Medicare & Medicaid Services (CMS) and as such might not be reimbursed by Medicare. The costs associated with reprocessing are often hidden and transferred by the vendor to the healthcare facility. Moreover, postoperative infections [ ] might not be reimbursed by Medicare. Sterile Spinal Implant: Rationale and Evidence 12

5. A new Generation of Implants : Sterile, Single Packaged, and Barcoded To prevent any concerns related to reprocessed implants, Spineart is providing since 2005 an entire range of sterile spinal implants. What are the advantages of pre-sterilized implants? NO contamination risk from reprocessing NO more transfer of liability NO risk of material corrosion FULL traceability and compliance Cost savings Spineart is providing since 2005 an entire range of sterile spinal implants. The Spineart implants are provided in individual boxes, sterile, with double packaging allowing a compliant transfer from a non-sterile to sterile area within the operating room. Along with the implant in its sterile double packaging, Instructions For Use (IFU) and stickers with reference, lot numbers and barcodes are provided inside the box. Spineart implant: packaged in double pouch; IFU and stickers labels with barcodes are inside the implant package. 13 SPINEART 2014

Sterile, Single Packaged, and Barcoded The outer box incorporates a wide label with a clear image of the implant, reference, size and quantity, lot number and expiration date. The barcodes conveniently summarize all that information in an easy to process format. The box is covered in an external wrap to provide additional evidence of any tempering with the packaging. External labeling with visual, references, size, quantity, lot number, expiration date and barcodes. Sterile Spinal Implant: Rationale and Evidence 14

Sterile, Single Packaged, and Barcoded No liability As the healthcare facility is not involved in reprocessing, there is no more transfer of liability from the vendor to the hospital with regards to implant sterility and integrity. In terms of potential claims arising from insurance companies or patients as a consequence of surgical wound infection, the use of sterile implants is also becoming critical in order to demonstrate that the healthcare provider made use of every available technology to reduce the risk for the patient. No more transfer of liability from the vendor to the hospital with regards to implant sterility and integrity. Full traceability All Spineart implants are barcoded, by part and lot number, using standard barcodes and 2D barcodes. With hospitals moving to Electronic Medical Records ( EMR ), such as Epic, Spineart is the only spine company with implants that can be scanned into any EMR system as they are implanted, removing human error. Spineart implants can be scanned into any EMR system. Image of label sticker provided with the Spineart individually packaged sterile implant. 15 SPINEART 2014

Sterile, Single Packaged, and Barcoded Cost effectiveness Sterile single packaged barcoded implants are alleviating the healthcare facility of the financial burden and time necessary for the reprocessing. Time and resources at the sterilization department are freed allowing more efficient and better quality service for the rest of the reusable instrumentation. The association of barcoding with an effective hospital tracking system ensures that only the implants used will be billed. Relieve the hospital of the financial burden related with reprocessing. Sterilization method Sterile single packaged implants are wrapped in sealed packaging and do not require washing and steam sterilization prior to use. Each implant used in procedure is taken out of its packaging only seconds before being implanted. Unlike for reprocessed spinal implants in implant racks, the risk for contamination pre, peri and post implantation is virtually non-existent. Manufacturing of sterile single packed implants by Spineart takes place in a clean room in compliance with ISO14644: 2004 Class 7, an FDA recognized standard. Implants are sterilized using Gamma rays. In a final validation step, specific tests are implemented to demonstrate implant cleanliness, cytotoxicity according to ISO 10993-5, systemic toxicity according to ISO 10993-11, pyrogen testing according to European Pharmacopeia, and various determination of residues level such as total organic carbon, total hydrocarbon and heavy metals. Sterile Spinal Implant: Rationale and Evidence 16

6. Conclusion Postoperative infections and its costly consequences call for a deeper understanding of risk prevention. Within this context, the use of reprocessed implants raises several concerns. One of the first questions is whether the supplier has validated that the implant sets can be safely reprocessed hundreds of times and if so, what are the consequences for the integrity of the surface of the implant. In addition, before and during the surgery the implants are exposed to hazardous contamination; even after the sterilization, it is well documented that endotoxins retain their biological activity. Biological and chemical residues will retain their immunogenicity after sterilization. The lack of traceability of implant batch may result in timeconsuming practices and a number of legal concerns that are associated with the responsibility for the sterilization of the implant. Working with prepackaged, sterile implants offers demonstrated advantages in terms of safety, implant integrity, traceability, liability and cost saving. 17 SPINEART 2014

spineart.com SPINEART USA 227 East 58 th St. 2 nd Floor New York, NY 10022 United States of America 9200 Irvine Center Drive, Suite 150 Irvine, CA 92618 United States of America 0714-V1 ref. SAF- FL EV 02-E Subject to modifications SPINEART SA 20 route de Pré-Bois 1215 Geneva 15 Switzerland S W I S S M A D E