Electro-Hydraulic Actuators

Similar documents
A descriptive definition of valve actuators

Example. Fluid Power. Circuits

Introduction to Process Control Actuators

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Frost & Sullivan. Publisher Sample

Electronic Flow Switches

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Hydraulic Troubleshooting PRESENTED BY

Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative

Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations

Electric Rotary Actuator - On/Off or programmable control actuator

The Secret of Hydraulic Schematics. BTPHydraulics

Hydraulic Control Solutions

V&A PROCONTROL. Rotary Valve Actuators Pneumatic & Hydraulic On-Off / Control / ESD Double Acting Spring Return All Steel SIL 3

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

ITT Control Technologies Industrial Products

In-Line Electronic Flow Switches

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Sanitary Type Electronic Flow Switches

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Fisher 377 Trip Valve

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Valve and Valve Actuator Selection Guide

How To Clean Up A Reactor Water Cleanup

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

GS-General Service Control Valves

Guidelines for operation of minimum flow control valves

Frequently Asked Questions

Unit 24: Applications of Pneumatics and Hydraulics

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Centro-Matic Automatic Lubrication Systems System Controls

Unit 24: Applications of Pneumatics and Hydraulics

Seismic Control and Infrastructure Solutions

INSTRUMENTATION & CONTROLS VALVE & AUTOMATION EXPERTS VALVE REPAIR TUBE SERVICES

Published in the Official State Gazette (BOE) number 166 of July 10th 2009 [1]

SD SEVERE DUTY CONTROL VALVES BULLETIN 1149 JULY 2002

HYDRAULIC ACCUMULATOR. Energy buffering applications APPLICATIONS OSP 035. Applications with short term high quantity oil requirements

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Electric Flow Boiler

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

Telefon (+45) Telefax (+45) Installation and operating manual

OCTOPUS SELECTION & INSTALLATION GUIDE

G-Series Pneumatic and Hydraulic Actuators. Next Generation Valve Automation Solutions

KNC Model 3666 Automatic Pressure Calibration System

Technical Specification. Generating Set with Waukesha engine burning natural gas

Pneumatic Actuators. Crafted without compromise, to make your life easier. The Leader in Actuator Technology

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Signature and ISX CM870 Fuel System

100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Hydraulic Control Technology for Wind Turbine Generators

Know-how makes the difference. Electrical Actuators

Safety Requirements Specification Guideline

Fisher 657 and 667 Diaphragm Actuators

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Unit 24: Applications of Pneumatics and Hydraulics

Diesel Engine Driven Generators Page 1 of 6

Industrial Steam System Process Control Schemes

TorqPlus TM Electric Valve Actuators and Controls

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Ventilstandarder ett urval av standarder

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

300 Series PA Pump and Cooler Assemblies

PRODUCT PROFILE FEATURES

Features and Benefits

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

In-Line Electronic Flow Switches

PNEUMATIC CONTROLS Selection and Description

ELECTROMECHANICAL ACTUATION FOR LAUNCH VECHICLES

Quiz On Information Learned From Chapter 1

Automatic control equipment for HVAC systems

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

ITT Industrial Products

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Heating Water by Direct Steam Injection

4 Posiflow Proportional Solenoid Valves

Hydraulic Flow Control Valves

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Maxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Fisher 2625, 2625SST, and 2625NS Volume Boosters

C. starting positive displacement pumps with the discharge valve closed.

RADIATION MONITORING SYSTEMS

creating progress for the future

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

Kobelco Extended Warranty Program.

COUNTERBALANCE VALVES

Boiler Preparation, Start-Up and Shutdown

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

HVAC Processes. Lecture 7

Why and How we Use Capacity Control

ZU4-Series, Portable Electric Pumps

Transcription:

IEEE Qualified for Valve and Damper Applications Electro-Hydraulic Actuators

Electro-Hydraulic Actuators Enertech, formerly Paul-Munroe Hydraulics, is a business unit of Curtiss-Wright Flow Control Company. Since 1967, Enertech has specialized in the supply of hydraulic equipment to the commercial nuclear power industry. In 1978, we recognized the need for a compact, fast acting hydraulic actuator to meet the demanding requirements of safe plant shut down and post accident cycling for valve and damper applications, both inside and outside containment. For over 30 years, Enertech has supplied valve and damper actuators that are qualified to stringent IEEE Standards for harsh environment conditions. Design Enertech s second generation electro-hydraulic operator (EHO) is fully self-contained for linear and rotary applications. The integral gas accumulator provides motive force for fail safe positioning upon loss of the electric command signal. The electric motor and hydraulic pump are IEEE qualified for post design basis event cycling following restoration of Class 1 power. Enertech s advanced EHO technology is ideally suited for large gate valves such as main steam isolation valves where high thrust, fast closing time of five seconds and sustained isolation force are mandatory. They are also designed for small torque outputs, such as damper actuators found on control room ventilation and other critical HVAC applications. In addition, Enertech s modulating EHO is industry proven in severe service control valve throttling applications including, PWR main steam atmospheric relief and main feedwater regulation. EHO on an Atmospheric Steam Dump Valve EHOs may be specified with one common hydraulic power unit containing an electric motor, pump and reservoir for fail safe control of up to four valves or dampers. Remote, skid mounted accumulators are offered for additional post accident cycling from stored energy without Class 1 power. Replacement for Legacy Electro-Hydraulic Actuators Enertech provides EHOs that are form, fit and function replacements for obsolete units found in many Generation II nuclear plants. Enertech s gas over oil design eliminates complex air pilot control sub loops found in competitors older electro-hydraulic actuator designs. Commercially available sub-components assure uninterrupted aftermarket support for the life of your plant. Environmental Qualification and Quality Assurance Enertech EHOs are used in nuclear safety and non-safety related applications around the world. Enertech EHOs have been successfully tested and qualified to IEEE 382, Case IV for inside containment design basis radiation, pressure, and temperature for safe plant shut down use. Seismic, vibration, and chemical spray conditions have also been successfully met in accordance with IEEE 344 and 323 Standards. All EHOs are manufactured under Enertech s Quality Assurance Program which complies with 10CFR50 Appendix B and NQA-1. Other nuclear quality standards for non- ASME governed plants may be specified. EHO on a Main Steam Isolation Valve 1

Enertech Second Generation EHO Features and Benefits IEEE Qualified - inside and outside containment applications Compact Design - highest available thrust or torque output to weight/mass ratio Self Contained - safe plant shut down energy; no air or Class 1 power supply required Fast Acting Response - ANSI Class 900, 36 gate valve Design Basis Event closure in less than 5 seconds. Closing time is independent of plant process condition and pressure Less than 1% Modulation Error - precise control valve positioning Partial Stroke Option - periodic testing of valve operability Dual Lock, Anti-Drift Design - prevention of position hunting Two Speed, Anti-Slam Damping Option - mitigation of water hammer Hand Pump Over Ride - manual cycling Why Enertech EHOs for Isolation and Throttling Applications? Electro-Hydraulic Pneumatic Electric Motor Fast Acting (< 5 seconds) Fail Safe w/o Class 1 Power Integral, Post Accident Cycling No Air Supply Required No Bulky Spring Packs Required Highest Thrust/Torque to Weight Ratio Less than 1% Positioning Error 2

EHO Nuclear Applications Linear Modulating Linear Two Position (On/Off) Product Description: Self-contained, modulating operator for precise control of linear gate, globe and diaphragm throttling valves. Self-contained, two-position linear operator for fast opening and closing of critical isolation valve applications. Features and Benefits: QME-1 Compliant Less than 1% Modulation Error Self-contained, No Air or Class 1 Power Required for Safe Plant Shutdown Post Accident Cycling QME-1 Compliant Fast Acting (< 5 sec.) Self-contained, No Air or Class 1 Power Required for Safe Plant Shutdown 10% Exercise Mode Typical Nuclear Applications: Recirculation Flow Control Valves Main Feedwater Regulation Atmospheric Steam Dump Valves Main Steam Isolation Valves Main Feedwater Isolation Valves Main Steam Bypass Valves Safety Injection Valves Specifications: Thrust: 5,000 to 250,000 lbs. Stroke Length: up to 18 in. Speed: up to 10.0 in./sec. Control Signal: 4/20mA; 10-50mA; 1-5 Volts Safety Mode: Post Accident Cycling Thrust: 5,000 to 250,000 lbs. Stroke Length: up to 28 in. Speed: up to 10.0 in./sec. Safety Modes: Fail Open; Fail Closed; Fail in Place 3

Rotary Two Position (On/Off) or Modulating Self-contained, rotary operator for twoposition or modulating service. Fast opening and closing and precise control of quarter turn ball, butterfly and plug valves. Distributed Power Units Distributed control of multiple valves and dampers or for applications where equipment may be inaccessible. Self Contained Rotary HVAC Damper Compact, quarter turn, rotary operator for direct mounting to louver and butterfly dampers and small valves. QME-1 Compliant Fast Acting (< 5 sec.) Self-contained, No Air or Class 1 Power Required for Safe Plant Shutdown Two-Speed Damping Control of One to Four Valves or Dampers with One Hydraulic Power Unit Additional Gas Volume Capacity for Post Accident Cycling QME-1 Compliant Compact Design for Direct Damper Mounting Weighs Less than 125.0 lbs. Self-contained, No Air or Class 1 Power Required Containment Isolation Valves Containment Purge Valves Recirculation Flow Control Valves Service Water Isolation Valves Feedwater Regulation Valves Recirculation Flow Control Valves Multiple Valves and Dampers Control Room Ventilation Dampers Tornado Dampers Containment Purge Dampers Torque: 2,000 to 300,000 in-lbs. Degree of Rotation: 0 to 180 Safety Modes: Fail Open; Fail Closed; Fail in Place Thrust: 100,000 to 400,000 lbs. Torque: 100,000 to 300,000 in-lbs. Safety Modes: Fail Open; Fail Closed; Fail in Place Torque: 100 to over 1,000 in-lbs. Degree of Rotation: 0 to 180 Response Time: < 10.0 sec. Safety Modes: Fail Open; Closed; Fail in Place 4

EHO Major Components 2 6 3 5 1 5 4 1 4 3 6 2 Rotary Hydraulic Operator Linear Hydraulic Operator 1 Reservoir Stores hydraulic fluid and feeds the pump to maintain hydraulic pressure and ensures the operator is able to function when required. 4 Solenoid Operated Valves (SOV) Provides directional control of the cylinder by diverting the flow of the hydraulic fluid. SOVs are used for both modulating and two-position functionality. 2 Pressure Switches Monitors the pressure of the nitrogen for fail safe operation. They also maintain the accumulator pressure by turning the pump on or off at specified high or low pressure settings. 5 Hydraulic Pump Maintains pressure in the accumulator. The pump receives signals from pressure switches. 3 Hydraulic Cylinder Heavy duty, equal area design delivers consistent force when performing both linear or rotary operation. 6 Accumulator Provides stored energy for fail safe operation and post accident cycling. 5

Standard Specifications Type - Self-contained electro-hydraulic or gas-hydraulic operator Power Supply - 220VAC, 3ph, 60Hz; 460VAC, 3 ph, 60Hz; 480VAC, 3ph, 50Hz Control Signal (mod.) - 4-20mA (250 ohms resistant) Output - Standard Sizes Linear - 2,000 lbs. to 250,000 lbs. (8.9-1,112 kn) Rotary - 2,000 in-lbs. to 300,000 in-lbs. (226-33,895 Nm) Stroke - Standard Sizes Linear - Up to 28.0 inches (711.2 mm) Rotary - Up to 180 Cycle Life - 5,000 (linear); 10,000 (rotary); full stroke Hysteresis - Less than 2% of input (modulating) Linearity - Less than 2% of total span (modulating) Stroking Speed - Adjustable from < 5.0 sec. to > 2.0 min. Failure Mode - User selectable on loss of signal (Fail close, fail open, fail in place) Environmental - IEEE 382-1980; IEEE 344-1975; IEEE 323-1974 Radiation - Total of 192 mega rads (100 mega rads normal/92 mega rads accident) Seismic - Seismic levels to 4.0g s OBE; 5.0g s safe shutdown Normal Conditions - 130 F (54.4 C), 100%RH Accident Cond. - 425 F (202 C), 66.0psig (4.56bar), 100%RH Hydraulic Fluid - Fyrquel EHC Additional Services Condition Monitoring Enertech can provide a continuous monitoring solution to ensure uninterrupted operation and provide the earliest indication of trouble. Enertech s diagnostic system monitors the EHO s system pressure, temperature and motor cycling to identify issues and predict when maintenance is required, minimizing downtime. Integrated Performance Testing This system allows the user to perform the same factory acceptance test performed by Enertech including stroke, deadband, linearity, hysteresis, feedback position, and frequency response. These tests can be performed remotely, minimizing risk from inaccessible locations and radiation exposure to plant personnel. Pump Skid Integration Enertech provides complete ASME Section III pump skid design and fabrication services for modularized delivery of safetyrelated units. Enertech can manufacture in accordance with ASME Section III, 10 CFR 50 Appendix B, Part 21 and NQA-1 for N Stamping of skid components and NPT Stamping of frame and connecting pipe. This includes seismic qualification of skid assemblies for critical to safety applications such as Diesel Generator Lube Oil Conditioning and Supply System. 6

Electro-Hydraulic Valve and Damper Actuators First in Customer Service to the Global Nuclear Power Industry Enertech, a business unit of Curtiss-Wright Flow Control Company, is an engineering, manufacturing, distribution and service company committed to providing solutions to meet the unique requirements of the nuclear power industry. Enertech provides advanced valves, actuators, pumps, instrumentation, heat exchangers, fluid sealing products, snubbers, diagnostic and test equipment, qualification and dedication services, maintenance, repair, and engineering services to the nuclear power industry. Enertech, located in Southern California, is a member of the Nuclear Group of companies (EMD, Nova, Scientech, Target Rock, Trentec), continuously supporting the global Nuclear Power Industry for over 50 years. Enertech 714.528.2301 http://enertech.cwfc.com enertech@curtisswright.com 2950 Birch Street Brea, CA 92821-6235 BR - 1188-12.2010R1 - ET