RAID systems within Industry



Similar documents
Application example and brief instruction 04/2015. LOGO! App V3.0. LOGO! 8 and LOGO! 7

Application on Control Technology

Configuration Instruction

Applications & Tools. Migration to TIA Portal. WinCC Basic / Comfort / Advanced STEP 7 V5.x / WinCC flexible 2008 SP3. Migration Guide September 2013

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

How To Use An American Zw.Com V20-20 (V20) V20 (Veu) V2.20 (Femalese) V1.2.2 (V2.1) V3.

Tool for Control Technology

Cover. WinCC/Server Virtualization. WinCC. Technical Information April Applications & Tools. Answers for Industry.

technology brief RAID Levels March 1997 Introduction Characteristics of RAID Levels

Cover sheet. How do you create a backup of the OS systems during operation? SIMATIC PCS 7. FAQ November Service & Support. Answers for industry.

Applications & Tools. Master Slave Communication via a CM PtP using the Modbus RTU Protocol. S CM PtP RS422/485 HF, ET 200SP CM PtP

Applications & Tools. Remote Control Concept with SCALANCE S Modules over IPsec-secured VPN Tunnel SCALANCE S. Application Description February 2010

TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS

Lecture 36: Chapter 6

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

White Paper A New RAID Configuration for Rimage Professional 5410N and Producer IV Systems November 2012

Specific Program Documentation ( License SPD )

Price/performance Modern Memory Hierarchy

Aljex Software, Inc. Business Continuity & Disaster Recovery Plan. Last Updated: June 16, 2009

GENERAL SOFTWARE LICENCE TERMS AND CONDITIONS of Fritz & Macziol GmbH Current as of March 2014

Backup and Recovery 1

RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card.

Intel RAID Controllers

RenderBooster User manual

Chapter Introduction. Storage and Other I/O Topics. p. 570( 頁 585) Fig I/O devices can be characterized by. I/O bus connections

RAID Made Easy By Jon L. Jacobi, PCWorld

RAID Technology Overview

Application about Communication

SPECIAL CONDITIONS OF PRIVATE CLOUD Version dated 08/06/2011

openqrm Enterprise Server and Client Licenses Agreement

OceanStor UDS Massive Storage System Technical White Paper Reliability

RAID 6 with HP Advanced Data Guarding technology:

Assessing RAID ADG vs. RAID 5 vs. RAID 1+0

Realize your full potential with the new version of SIMATIC PCS 7

1. Content and implementation. 2. Services of Matrix42 GENERAL TERMS AND CONDITIONS OF BUSINESS

CRM in a Day Support Services Agreement

Conditions for the Provision and Maintenance of Software

Created By: 2009 Windows Server Security Best Practices Committee. Revised By: 2014 Windows Server Security Best Practices Committee

Standard diagnostic and configuration interface for Beckhoff Industrial PCs

COLOCATION SERVICE SCHEDULE

RAID. Contents. Definition and Use of the Different RAID Levels. The different RAID levels: Definition Cost / Efficiency Reliability Performance

Jigsaw24 Support Contract Terms & Conditions

an analysis of RAID 5DP

RUGGEDCOM NMS for Linux v1.6

Terms of sale, payment and delivery. I. General Commitment

RAID HARDWARE. On board SATA RAID controller. RAID drive caddy (hot swappable) SATA RAID controller card. Anne Watson 1

Input / Ouput devices. I/O Chapter 8. Goals & Constraints. Measures of Performance. Anatomy of a Disk Drive. Introduction - 8.1

Firebird and RAID. Choosing the right RAID configuration for Firebird. Paul Reeves IBPhoenix. mail:

TestRail Cloud Terms of Service

Getting Started With RAID

WinCC Options. Redundancy. Manual C79000-G8263-C142-01

Benefits of Intel Matrix Storage Technology

RAID technology and IBM TotalStorage NAS products

Software License Agreement for Beckhoff Software Products

Application about Communication

General Terms and Conditions Advertiser

CS 6290 I/O and Storage. Milos Prvulovic

General terms of delivery. for GEUTEBRÜCK system components with GEUTEBRÜCK software

GENERAL TERMS AND CONDITIONS Siconnex Singapore PTE Ltd. ( )

Hard Disk Drives and RAID

COLOCATION SERVICE SCHEDULE

DODO WEB HOSTING TERMS OF SERVICE

Definition of RAID Levels

High Availability Server Clustering Solutions

Security+ Guide to Network Security Fundamentals, Fourth Edition. Chapter 13 Business Continuity

User Agreement. Quality. Value. Efficiency.

RAID Basics Training Guide

NETWORK SERVICES WITH SOME CREDIT UNIONS PROCESSING 800,000 TRANSACTIONS ANNUALLY AND MOVING OVER 500 MILLION, SYSTEM UPTIME IS CRITICAL.

Applications & Tools. Monitoring Machines and Plants with Network Cameras and SIMATIC HMI Comfort Panels. WinCC V11 Comfort

Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems

IBM ^ xseries ServeRAID Technology

This chapter explains how to update device drivers and apply hotfix.

Beckhoff onboard SATA-RAID

Dell Reliable Memory Technology

QuickSpecs. Models. HP Dynamic Smart Array B320i Controller. Overview

VERITAS Volume Management Technologies for Windows

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

(1) Our offers are subject to change, unless they are explicitly designated as

How to choose the right RAID for your Dedicated Server

RAID: Redundant Arrays of Independent Disks

Every organization has critical data that it can t live without. When a disaster strikes, how long can your business survive without access to its

Intel RAID Volume Recovery Procedures

MoniUPS Software and Service. with an expert

GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4

Testing, Inspection and Weight

USER GUIDE. PageScope Enterprise Suite. Backup and Recovery

BrightStor ARCserve Backup for Windows

Fault Tolerance & Reliability CDA Chapter 3 RAID & Sample Commercial FT Systems

How To Create A Multi Disk Raid

Transcription:

White Paper 01/2014 RAID systems within Industry Functioning, variants and fields of application of RAID systems. A white paper issued by: Siemens. Siemens AG 2014. All rights reserved

Warranty and liability Warranty and liability Note This document is not binding and do not claim to be complete regarding the circuits shown, equipping and any eventuality. The document does not represent customer-specific solutions. It is only intended to provide support for typical applications. You are responsible for ensuring that the described products are used correctly. This document does not relieve you of the responsibility to use safe practices in application, installation, operation and maintenance. When using this document, you recognize that we cannot be made liable for any damage/claims beyond the liability clause described. We reserve the right to make changes to this document at any time without prior notice. If there are any deviations between the recommendations provided in this document and other Siemens publications e.g. Catalogs the contents of the other documents have priority. We do not accept any liability for the information contained in this document. Any claims against us based on whatever legal reason resulting from the use of the examples, information, programs, engineering and performance data etc., described in this document shall be excluded. Such an exclusion shall not apply in the case of mandatory liability, e.g. under the German Product Liability Act ( Produkthaftungsgesetz ), in case of intent, gross negligence, or injury of life, body or health, guarantee for the quality of a product, fraudulent concealment of a deficiency or breach of a condition which goes to the root of the contract ( wesentliche Vertragspflichten ). The damages for a breach of a substantial contractual obligation are, however, limited to the foreseeable damage, typical for the type of contract, except in the event of intent or gross negligence or injury to life, body or health. The above provisions do not imply a change of the burden of proof to your detriment. Any form of duplication or distribution of this document or excerpts hereof is prohibited without the expressed consent of Siemens Industry Sector. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a productspecific newsletter. For more information, visit http://support.automation.siemens.com. 01/2014 2

Table of contents Table of contents Warranty and liability... 2 1 Motivation... 4 2 Targets... 4 3 Implementation... 5 3.1 Software RAID vs. Hardware RAID... 5 3.2 RAID levels... 5 3.2.1 RAID 0... 6 3.2.2 RAID 1... 6 3.2.3 RAID 5... 7 4 Maximizing the System Availability... 8 4.1 Recognizing impending failures in time... 8 4.2 Minimizing the system down-time via hot swap... 8 4.3 Immediate recovery of a RAID group via hot spare... 8 5 Conclusion... 9 01/2014 3

1 Motivation 1 Motivation Information processing systems are subjected to stress in the form of dust, shock/vibration, electromagnetic interference and extreme temperatures when employed in rough environments. Siemens AG 2014 All rights reserved Figure 1 Special industrial PCs have been developed which can withstand these stressful conditions and are protected especially against these influences. Apart from the protection from external influences, the data of information processing systems requires particular attention. For error-free and smooth operation these are equally important as the hardware components. If a data carrier fails, the operation is interrupted until the data carrier has been exchanged and the backed up data restored. If only a very old backup or no backup of the system exists, extensive and timeconsuming setup measures become necessary. However, the most recent data, which might be used in running production processes, will be lost despite of the backup. How can the availability of a data carrier, hence the entire information processing system be increased? 2 Targets One aim is to increase the availability of the data by means of suitable measures. Closely related to this is the demanded protection of the saved data from data loss during the failure of a data carrier. The system output must not be reduced by the measures. 01/2014 4

3 Implementation 3 Implementation Explanation of Terms The mentioned objectives can be reached by using RAID systems for data storage. Table 1 RAID Abbreviation Meaning Redundant Array of Independent Disks This refers to the combination of several physical data carriers into one logical data carrier. There are different implementations which are discussed below. 3.1 Software RAID vs. Hardware RAID Several physical data carriers can be combined into one logic data carrier using software as well as special hardware. This is implemented by means of a RAID controller. The advantages and disadvantages of both options are listed in the table below. Table 2 Pro Software RAID In the case of a HW defect, the saved data can also be read from a different system Hardware RAID Relieving the CPU and the system bus Exchange possible during runtime Contra CPU load and system bus Cache usage problematic during system failure or power cut Additional hardware/costs for the controller Defect at the controller requires identical model 3.2 RAID levels RAID levels describe the way in which several data carriers are combined and used. The various RAID levels are mainly distinguished by the following characteristics: Available total capacity for data storage Data security during failure of a data carrier Data throughput during reading Data throughput during writing Number of required hard discs RAID levels 0, 1 and 5 have been established. These are discussed in greater detail below. 01/2014 5

3 Implementation 3.2.1 RAID 0 In RAID level 0, the data to be saved are divided between the individual data carriers. This is done without redundancy. Parallel access to the individual data carriers accelerates the data throughput during reading as well as during writing. However, this type of interconnection bears the risk of data loss. If a physical data carrier works with errors, the logic connection of the data carrier is also defective. Figure 2 Table 3 Read Speed Write Data security 3.2.2 RAID 1 In RAID level 1, the data to be saved is mirrored and stored on the data carriers. This redundant type of data storage preserves the data even during the failure of one data carrier. Figure 3 Read Speed Write Data security Table 4 01/2014 6

3 Implementation 3.2.3 RAID 5 In RAID level 5, the data to be saved is stored on the data carriers. Additionally, a parity data block is generated for the saved data which in return is stored on a separate physical data carrier. Using this parity data block, the original information can be restored when the data carrier is faulty. Considered simply, the following applies for the first line in the figure: A + B = P AB This enables reconstructing the original data in the event of an error, for example: B = P AB A A = P AB A The distributed storage of the parity data blocks on all data carriers prevents an excessive load on individual data carriers. In addition the data throughput during reading can be accelerated. RAID level 5 requires at least 3 hard drives. Figure 4 Table 5 Read Speed Write Data security 01/2014 7

4 Maximizing the System Availability 4 Maximizing the System Availability 4.1 Recognizing impending failures in time Apart from the redundant storage of data in the RAID array, early detection of errors is an important aspect for increasing the availability of the system. Detecting errors especially includes the monitoring of critical system components: speed of casing fans, casing temperature, S.M.A.R.T. 1 state of the data carrier. If the failure of a component becomes apparent due to abnormal values, this should be indicated by an automatic message via e-mail or SMS text message. The required spare parts can then be procured on time and, if necessary, be exchanged without any time delays. Diagnosis should be possible locally as well as remote. 4.2 Minimizing the system down-time via hot swap Another way of reducing the down-times of an information processing system is its ability to exchange defective components especially data carriers during runtime. This ability is referred to as hot swap. In connection with redundant saving of data in a RAID system, this enables uninterruptible operation while exchanging the defective data carrier. 4.3 Immediate recovery of a RAID group via hot spare During the failure of a data carrier the risk of data loss is increased. If another data carrier fails before the defect data carrier has been replaced, the data can t be restored. To avoid that a hot spare data carrier can be installed, that immediately steps in when a defect occurs. Thereby the RAID group hence the data consistency is fully available. The defect data carrier doesn t have to be replaced immediately. The replacement can be integrated into a perfunctory service task. 1 S.M.A.R.T. = Self-Monitoring, Analysis and Reporting Technology, that means a system for monitoring hard discs and providing early detection of impending defects. 01/2014 8

5 Conclusion 5 Conclusion Depending on the used RAID level, RAID systems are suitable for reducing the risk of data loss as well as for increasing the speed at which the data is to be transferred. This, for example, can reduce the time necessary for creating reports based on many process values from archive data or databases. The interconnection of data carriers into one RAID level 5 gives the user security from data loss during the failure of a data carrier as well as improved performance when transferring the saved data. Furthermore, useful functions and capabilities, such as automatic notification in the case of an error as well as hot swapping of data carriers, help increasing the overall availability of a system. However, the application of a RAID system is no substitute for regular backups of important data; it must be considered as a useful supplementation. 01/2014 9