Guidelines how to set up an ESD Protected Area (EPA)



Similar documents
The Prevention and Control of Electrostatic Discharge (ESD) (AN )

W ant to accomplish something

The Prevention and Control of Electrostatic Discharge (ESD) (AN )

Example ESD Control Program Document Based on ANSI/ESD S

ACL 600 Stati-Check Meter

THE 7 SINS OF ESD CONTROL CERTIFICATION TEST (DVD-78C)

ACL 395 Resistivity Meter

ACL 800 MEGOHMMETER OPERATION MANUAL

FUNDAMENTALS OF ESD. A Primer on Electro-Static Discharge

Test Reports with Ameriworx Conductive Vinyl Tile ANSI ANSI ESD S7.1 ESD STM97.1 ESD STM97.2

Use ESD Control Products Correctly Or You Can Do More Harm Than Good

3mm Photodiode,T-1 PD204-6C/L3

Release: 1. ICTWOR3093A Manage spare parts

Asbestos. from the Home. Removing. Read this booklet for:

New Printhead. Properly Maintained Printhead Over 1 Million Inches

Controlling Static Electricity in Modern Buildings

Spill Kits and Incidental Spill Response

OHM-STAT CT-8700 OWNERS MANUAL & OPERATION GUIDE

APPLICATION NOTES FOR SMD LEDs

Discussion Leaders Guide Session Slips, Trips and Falls

VERIFICATION OF ESD ENVIRONMENT IN PRODUCTION PHILOSOPHY, METHODOLOGY AND TOOLS

StorTrends 3400 Hardware Guide for Onsite Support

Care and Maintenance for Wood Flooring

Replacing the Gateway M675 Keyboard

Asbestos frequently asked questions

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

I.T. CHAPTER 2. Which three computer components contain hazardous materials and require special handling for disposal? (Choose three.

LABORATORY SAFETY INSPECTION CHECKLIST

Louisiana State University Information Technology Services (ITS) Frey Computing Services Center Data Center Policy

Model 1756 Test Lead Kit

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Auditing Contract Manufacturing Processes

3M Wrist Strap and Footwear Tester 740. User s Guide

EasyNote TJ Series. Disassembly Manual

CHARLESWATER ESD AWARENESS BOOKLET

ESD/EOS ESD Electrostatic Discharge (ESD) Why Should I Care About Electrostatic Discharge?

Slips Trips & Falls. What To Avoid

New Printhead. Properly Maintained Printhead Over 1 Million Inches

Replacing the Gateway M320 Keyboard

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

... more than you expect. Shipping supplies

OVERVIEW OF CONSULTING AND AUDITING PROJECTS

Congratulations! Quality products for quality floors

Guidelines for the Management of Spillage of Cytotoxic Drugs. No changes have been made as evidence base remains current.

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Technical Resource Guide SLIP, TRIP AND FALL --- Alabama Self-Insured Worker's Compensation Fund SAFETY MANAGEMENT CONTROL PLAN.

SPILLS & SPILL KITS. Spills -General Guidelines:

Hard Disk Drive (HDD)

SAFEGUARDING YOUR EMPLOYEES AND CUSTOMERS: MITIGATING SLIP AND FALL RISKS

PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL

Care and Handling of Your VAIO Computer

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

SPECIFICATIONS FOR APPROVAL

SMD LED Product Data Sheet LTST-S310F2KT Spec No.: DS Effective Date: 10/30/2013 LITE-ON DCC RELEASE

C ampus Building Recycling Guide

MIC-WKT and MIC-WKT-IR

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Part 2. Overview. Risk management. Workplace health and safety legislation. How should asbestos exposure be managed? Identifying asbestos hazards

Operating and Installation Instructions

Waste Management Log Book

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

George master UK A06.indd 1 07/02/ :25:11

Service Guide. Gateway M275

CONTROL METHODS. There are five ways to control the release of asbestos fibers:

US Bank Tower Cincinnati Recycling

RESIDENTIAL HARDWOOD WARRANTIES


If you hire a Professional Wood Fitter. If fitting the Wood Floor yourself (DIY)

i410/i1010 AC/DC Current Clamp

School of Engineering University of Glasgow

Amtico and Spacia Commercial Maintenance Guidelines

ASBESTOS AWARENESS IN THE WORKPLACE. This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

HP SATA/SAS hard drive and Solid State Drive installation

Absolute Maximum Ratings

3 WATT LED SPOTLIGHT Model No. SLM

HealthandSafetyOntario.ca. Hazards. Introduction. Legislation

HARDWOOD WARRANTIES Limited Warranty for Prefinished Solid, Engineered, and Longstrip Floors Manufacturing Defects Finish Warranty

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

CLEAN ROOM TRAINING CLEAN ROOM AREAS

15GAL STEEL OIL DRAIN WITH 110V PUMP

Harvatek Surface Mount LED Data Sheet HT-T167 Ultra-bright Reverse Gullwing Series

CLEAN UP FOR VOMITING & DIARRHEAL EVENT IN RETAIL FOOD FACILITIES

EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts

Selecting a Moisture Barrier Bag

Harvatek Surface Mount LED Data Sheet. HT-F195 Series

Harvatek Surface Mount CHIP LED Data Sheet HT-380FCH-ZZZZ

Chemotherapy Spill Response:

Cable Discharge Event

Nokia Bluetooth Headset BH /1

SAFETY SELF-INSPECTION PROGRAM

Guidelines for Mold Remediation (Removal)

SEMME3012 Installing marine lighting, alarm, detection and monitoring equipment and systems

Standard Operating Procedure

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Samuel Shorty Bunk Bed

Guidance on preventing Slips, Trips and Falls

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

Asbestos Work Permit Procedures

Laboratory Safety and Environmental Health Assessment Program

Transcription:

ImplementingESD safe materialsandproductsshouldbeperformedaccordinga specific logical ESD strategy. Without these specific ESD procedures it has little to no sense to install ESD safe products. Therefore we recommend toperforma pre audit describedin the ESD plan of approach, on the next pages. ThisESD plan of approach, must bebasedon recent recordingsof the company, anoverview of the measurestobetaken in the field of protectionagainststaticelectricity, as well as the facilitieshave tobetaken in thiscontext. A distinctionis made betweenthe necessary, preferably directly implementing provisions and recommended facilities that can be realized on longer terms.

Commonly used terms: ESD = electro static discharge (ESD) ESDS = electro static discharge sensitive(sensitive to static discharges) EPA= ESD protectedarea (ESD-safe area) KvF= Faraday cage Pink Poly = plastic film products with a non-rechargeable(pink) coating Shielding= packagingmaterialswitha metallized(conductive) layer: These materials thus have a KvF function. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

1. Yellow ESD label (EPA entering notification) 2. Yellow ESD label (EPA whereabouts notification) 3. Yellow ESD label (EPA leaving notification) 4. Wrist straps and footwear tester 5. Footwear tester plate 6. Footwear and wrist straps testing protocol 7. ESD linoleum 8. Worktop grounding cable 9. Shelves grounding cable 10. Conductive wrist straps 11. Antistatic mat 12 Connecting plug for grounding cables 13 ESD boxes 14 SMD cabinet 15 L-shape PCB holder 16 Soldering station in ESD version 17 ESD gloves 18 Ionizer 19 ESD tools 20 ESD bags 21 ESD laboratory chair 22 ESD shoes 23 ESD garments 24 Conductive binders 25 ESD waste bin 26 Alliance series ESD workbench 27 Classic series ESD workbench 28 Movable table 29 Shelving 30 Hygrometer 31 Grounding panel 32 Floor adhesive tape with ESD marks

A. First step: Drafting your ESD procedure: First itshouldbeclearlydefinedwhichzones are EPA andwhichare not. Access tothese areascanonlybeprovidedtothosewhoare aware and comply with the preventive prescribed measures. This requirementappliestoeveryone, private operators, management, temporaryemployees, subcontract, maintenance personnel, visitors,... Of general interest: correctly adjusting the humidity. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

1. AllareaswhereESD safe workis beingperformedshouldpreferablybe markedas such; usingspecial ESD warningshieldsor stickers and/ or floor markingtape, the EPA scanclearlybemarked. Demarcationanddefiningthe EPA (ESD Protected Area) all this to keep out and end off misunderstandings and unauthorized in these critical area(s) where ESD safe should be worked. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

2. For the control of wrist strap, grounding cables, ESD shoes or heel grounders, it is necessary to provide and install a wrist-band/shoe-test station, in a prominent place, preferably at the entrance to the EPA. Also the wristbands and grounding cables of the field service kits from any field staff can be checked here. It is recommended that the staff fill in each check, with date and initials, on the checklist hanging next to the tester. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

2.a. Access control: before entering the EPA wristbands, grounding cables and footwear always should be checked. Possible access may or may not be linked to an ESD Access System. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

3. Footwear: The same principle applies to us humans. We want to enter the EPA we need to check our ESD safe shoes The range is very extensive and we make a distinction between ESD safe and ESD-safe safety shoes. When working ESD safe, consistently checking is really required, this is why you have to check your footwear and wristbands daily before entering the EPA. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

4. Wearing ESD clothing is strongly recommended so charges accumulated by motion, and therefore friction of our normal clothes, can be shielded from the sensitive components. Why ESD clothing is so important? We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

4.a. ESD clothing : Why ESD clothing is so important? (video) WhyESD clothingis soimportant? We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

5. ESD safe Workbenches provided by BASS-ESDproducts. All of these tables are to be connected via a resistor of 1 MOhmcoupled to ground/earth. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

6. Earthing/ grounding: The ESD standard IEC 61340-5-1/5-2 says that when one is performing his job sitting a wrist strap to ground always need to be worn. It is obvious that we also have to connect our workbenches and shelves to earth. We do this with grounding plugs and grounding cables (these are included in the table) We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

7. Tools: Certainly not unimportant because with this tool one comes closest to the ESD sensitive components, so it is strongly recommended to use ESD safe tools. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

8. ESD Chairs: Here you have a wide choice from our collections that give us the assurance and guarantee that the seats are really ESD safe. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

9. Trolley's: For transporting goods within the EPA, it is important they don't generate static charge caused by friction of the wheels. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

10. All ESDS components and printed circuit boards should be stored throughout the company and transported in an ESD-safe packaging with KvFfunction; this may be in the type of a static shielding bag or a container of conductive plastic. The shielding bags can be sealed with. ESD with special warning stickers. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

11. Pink poly products, such as the rose packing bags and bubble foil, are not rechargeable (antistatic). These products however have not KvFfunction and are intended primarily as a non-rechargeable or disposable packaging for temporary use only used in the EPA. The antistatic coating in the plastic evaporated namely, under the influence of UV light, after a period of time, and loses its effect (the typical pink color is in this case becomes more pale). We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

12. The first and most important step in ESD safe working is to make sure that there are NO static materials in the EPA are present. The use of static rechargeable (packaging) materials, coffee cups, plastic folders, trash bags, etc., in an EPA should be avoided whenever possible. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

13. To ensure an adequate internal control it is strongly recommended to provide the ESD coordinator within the company off a surface resistivity meter and an electrostatic field meter. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

14. Floor: This is provided and should conform to EN / IEC 61340. In case of optimization at standing work ESD anti-stress mats can be offered. The maintenance of an ESD floor should be done with appropriate detergent aims to prevent the floor to become insulation by using ordinary cleaning agents. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

15. Warehousing and stock must be stored in proper packaging and custom carrying racks or cabinets. The packaging of ESD sensitive components must be done in the right packaging Pink bags do not protect against static charges and may only be used within the EPA. Sensitive components (without housing) which will transported outside the EPA should be put in Shielding bags or Moisture barrier bags (if they are susceptible to oxidation). We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

16. ESD Cleaning & maintenance: The installation of an ESD is very important and requires expertise. Even more important, and all too often overlooked, is the maintenance of these ESD protected areas. ESD conductive (dissipative surfaces), floor as well as table, should be treated with appropriate ESD-cleaners and cleaning utilities to assure these conductive properties are preserved. The use of ESD vacuum cleaners according the ESD Standards is of utmost importance not want to cause damage to ESD sensitive components within the EPA. We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

17.In addition taking the necessary ESD measures, it is important that all personnel, directly or indirectly, in contact with ESDS products is well aware of the phenomenon of ESD. B.A.S.S. ESDproductsprovides special ESD courses and trainingwhich explains and shows the dangers of dealing with electrostatic charges, how you can recognize and protect ESDS devices getting damaged by ESD. Getting familiar with the phenomenon Electro Static Discharge (ESD) Identifying the damage that ESD can cause Learning methods to prevent ESD damage History ESD, what is... Electrostatic charges Electrostatic discharges ESD damage ESD damage models How to prevent ESD damage Why now also aggregates? Trends.

C. How far should you go? You certainly do not have to work in a cleanroom to work ESD safe. However, there are a number of measures which should be takencare of: 1) The EPA work has been done and will therefore be contaminated. It is very important to clean the ESD floor in a proper manner by using the correct cleaning products. It's better (safer) just to use only water to mop the floor or use an ESD-safe detergent. 2) Clothing: An item that is all too often neglected but is a very important part in your link of ESD safe working. This ESD clothing will ensure that electrostatic loads on your body and clothing will be shielded from your sensitive components. How far should you go in here... this will have to show your risk analysis. Here is a list of extras that you can implement over time: Overview ESD-Products: ESD-Chairs ESD-Cleaning ESD-Clearance Corner ESD-Garment ESD-Office Supplies ESD-Packing / Shipping ESD-Personal Grounding ESD-Storage ESD-Test / Meassureing Equipm. ESD-Workbenches ESD-Workstation Products

"Measuring is knowledge" "ESD standard" -"don't live by them, implement them" * IEC 61340-2-1 Measurement methods - Ability of materials and products to dissipate static electric charge. * IEC/TR 61340-2-2 Measurement methods - Measurement of chargeability. * IEC 61340-2-3 Methods of test for determining the resistance and resistivity of solid planar materials used to avoid electrostatic charge accumulation. * IEC 61340-3-1 Methods for simulation of electrostatic effects - Human body model (HBM) - Component testing. * IEC 61340-3-2 Methods for simulation of electrostatic effects - Machine model (MM) - Component testing. * IEC 61340-4-1 Standard test methods for specific applications - Electrical resistance of floor coverings and installed floors. * IEC 61340-4-3 Standard test methods for specific applications - Footwear. * IEC 61340-4-5 Standard test methods for specific applications -Methods for characterizing the electrostatic protection of footwear and flooring in combination with a person. * IEC 61340-5-1 Protection of electronic devices from electrostatic phenomena - General requirements. * IEC/TS 61340-5-2 Protection of electronic devices from electrostatic phenomena - User guide.

EPA Check List NA OK! Define responsibilities / contacts Train the managers and contacts Define the ESD sensitivity Analyze the space and surroundings Define the required materials Contact suppliers Release the new materials Order materials Install EPA Release the EPA Train the staff Integrate the EPA in the audit plan Perform corrective measures We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

MATERIALS Check List NA OK REMARKS Shoes Foot straps Clothing Wriststraps grounding cords Floor Floor Mats Workbench Table Mats Fieldkit Packaging We believe all the information in these pages including technical data to be reliable. However we make no warranties expressed or implied and assume no liability regarding any use of this information.

Contact B.A.S.S. -ESDproducts Bruno Depré ESD -ambassador- owner Barones Ludwina de Borrekenslaan 35 B-2630 Aartselaar tel +32 3 230 19 75 fax +32 3 230 19 78 Mob +32 489 312 680 Skype: bruno.depre sales@esdproducts.eu /en