USER'S INFORMATION MANUAL

Similar documents
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SL280UHV SERIES GAS FURNACE WARNING

CARING FOR YOUR WATER HEATER

/2010 US/CA

Tankless Water Heater

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

INSTALLATION INSTRUCTIONS

Service Manual Models: 502, 752, 1002, 1302,

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Service Manual Models:

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Operating Instructions & User s Information Manual VITODENS 100-W WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

User s Operation Manual - contents

PART 11: START-UP PROCEDURES FOR THE INSTALLER

Service Manual Models:

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

Operating Instructions & User s Information Manual VITODENS 100-W WARNING. IMPORTANT Read and save these instructions for future reference.

Operating instructions

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Your safety and the safety of others are very important.

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

TANKLESS WATER HEATER USE AND CARE MANUAL

Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water

Boiler Preparation, Start-Up and Shutdown

G670 Intermittent Pilot Ignition Controls

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Operator: Save these instructions for future use!

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

Luna 3 Comfort Troubleshooting Guide June 2008

Operating instructions

Fuels Safety Program FS DIRECTOR S PUBLIC SAFETY ORDER

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

37E73A-903 & 906 INTELLI-VENT

Water Heaters. Residential 30, 40 and 50 Gallon

Installation Instructions for Alarm Module Kit A043F059

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Preventing Overheated Boiler Incidents

Model Description / Applications. Intermittent Pilot Gas Ignition Control

USER S INFORMATION MANUAL

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

Owner s Manual 58HDX UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE. ama ! WARNING SAFETY CONSIDERATIONS

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

GAS SAFETY PRECAUTIONS

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

94% CONDENSING TANKLESS WATER HEATER USE AND CARE MANUAL

User's Instructions. Alpha HE CB25/33 and HE SY25


INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Residential 30, 38, 40, 50 and 60 Gallon

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Service Manual Models: ER152, ER202, ER252, ER302, and ER402

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE

Residential Gas Water Heaters. Residential 30, 38, 40 and 50 Gallon

Water Heaters. Residential 30, 40 and 50 Gallon

A Class Air Source Heat Pump User Guide

Model NC380-SV-ASME. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Service Manual. Condensing Boiler. Getting Service

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

Baxi Combi 80e & 105e

INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

n NOTICE n WARNING Read and review this entire manual with special emphasis on the Venting and Operation Sections prior to any installation work.

Installation & Operation Manual Models: SIT030 - SIT119

1 For All Non-Programmable Digital Thermostat

Electric Water Heater

Caution! Observe the safety instructions of this installation and maintenance manual before placing the boiler in operation. Danger!

INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

INSTALLATION INSTRUCTIONS

OPERATING, INSTALLATION AND SERVICE MANUAL

Installation Operation Maintenance

Heat Pump Water Heater

Use and Care Instructions Dual Gas Steam Generator & Convection Steamer

Boiler Manual. Installation Startup Maintenance Parts WARNING

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

INSTALLATION & SERVICE MANUAL

Water Heaters. Use & Care Manual. Electric Point of Use IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Instruction Manual for Residential Gas Water Heaters

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Operating Instructions. VITODENS r 200/222 Series With Vitotronic 200 HO1B Controls WARNING WARNING IMPORTANT

Oil and Coolant Circulating Heating System. Model - OCSM

Use & Care Manual. Electric Residential Heat Pump Water Heaters. With Installation Instructions for the Installer. Residential 50 Gallon - HB Series

Transcription:

USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Information and specifications outlined in this manual in effect at the time of printing of this manual. Manufacturer reserves the right to discontinue, change specifications or system design at any time without notice and without incurring any obligation, whatsoever. P/N 240008847, Rev. C [09/2011]

1 - general 1.1 General This boiler has few user serviceable parts. Maintenance and Service must be completed by qualified agency. 1.3 What To Do Should Overheating Occur Do not turn off or disconnect electrical supply to pumps. Shut off gas supply at location external to appliance. WARNING Fire, explosion, asphyxiation and electrical shock hazard. Improper maintenance and service could result in death or serious injury. Read this manual and understand all requirements, including use of qualified agency where directed. 1.4 What To Do If Boiler Or Any Part Has Been Under Water Do not use boiler if any part has been under water. Immediately call a qualified service technician to inspect boiler and to replace any part of control system and any gas control which has been under water. 1.2 Become familiar with symbols identifying potential hazards. This is the safety alert symbol. Symbol alerts you to potential personal injury hazards. Obey all safety messages following this symbol to avoid possible injury or death.!!! DANGER Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Used to address practices not related to personal injury. 2

2 - Operating instructions For your safety read before operating! WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance is equipped with an ignition device which automatically lights burner. Do NOT try to light this burner by hand. Before operating smell all around appliance area for gas. Be sure to smell next to floor because some gas is heavier than air and will settle to the floor. Use only your hand to turn the gas shutoff valve. Never use tools. If valve will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in fire or explosion. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect appliance and to replace any part of control system and any gas control which has been under water.! 2-1 Gas Shutoff Valve CAUTION WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. 2.2 TO TURN OFF GAS TO APPLIANCE Set thermostat to lowest setting. Turn "OFF" all electric power to appliance if service is to be performed. Remove front jacket panel. Turn gas shutoff valve handle clockwise to closed position. Handle should be perpendicular to gas pipe. Replace front jacket panel. 2.1 OPERATING INSTRUCTIONS Stop! Read Safety information above. Set thermostat to lowest setting. Turn " OFF" all electrical power to appliance. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light burner by hand! Remove front jacket panel. Turn gas shutoff valve clockwise to closed position. Handle should be perpendicular to gas pipe. Wait 5 minutes for any gas to clear. Smell for gas, including near floor. If you smell gas, STOP! Follow instructions on this page: What To Do If You Smell Gas. If you do not smell gas, go to next step. Turn gas shutoff valve counter clockwise to the open position. Handle should be parallel to gas pipe. Replace front jacket panel. Turn " ON" electrical power to appliance. Set thermostat to desired setting. If the appliance will not operate, follow instructions TO TURN OFF GAS TO APPLIANCE and call your service technician or gas supplier. OPEN POSITION CLOSED POSITION Gas Shutoff Valve 3

3 - Control Module 3.1 Introduction Boiler is equipped with a programmable electronic control and user interface module. Operation with LCD character display module 3.2 Operation Key Description - Manual Lockout Reset - Enter/Exit user menu - Go to previous screen - Select a menu item - Confirm new parameter value - Scroll up to next menu item - Increase value - Scroll down to next menu item - Decrease value 3.3 Status Indication The following status screens can be displayed: Boiler Status Indicator F = Flame Detected SERVICE Reminder P = Central Heating/System Pump On B = Combustion Air Blower On S = Safety Relay Check G = Gas Valve Open D = DHW Pump On Combustion Air Blower Speed Indicator Service Reminder Indicator Boiler in Standby Mode Boiler Supply Water Temperature Indicator Boiler Running in Central Heat mode Boiler Running in DHW mode Lockout Alarm Indicator Error code and short text description displayed. Press Reset key for manual reset. Blocking Error Error code and short text description displayed. Boiler automatically returns to Standby Mode when condition eliminated. 4

3 - Control Module 3.4 Sequence of Operation Operational State User Interface Display Explanation Ready for Operation Boiler operates in standby mode until demand for Central Heat (CH) or Domestic Hot Water (DHW) detected. Call for heat. Thermostat Starts Call for Heat CH/System or DHW pump turned ON based on type of heating demand. Heat Exchanger Pump also turned ON. (CH demand illustrated) Pre-Purge Combustion Air Blower energized. Combustion Air Blower speed modulates to prepurge setting for 15 seconds. Trial for Ignition Igniter energized to start sparking sequence. Gas Valve energized to deliver air/fuel to burner. Igniter de-energized. Normal Operation Thermostat Ends Call for Heat Post-Purge Ready for Operation Boiler runs provided all operational and safety devices within limits. Control Module adjusts firing rate to match heating demand. Call for heat ends. Post purge cycle for 30 seconds. Combustion Air Blower modulates to post purge setting. CH/System Pump, DHW pump, and Heat Exchanger Pump operate. Boiler returns to Standby Mode. 5

3 - Control Module 3.5 Theory of Operation User Interface Display Explanation STANDBY S t a n d b y : N o D e m a n d 7 5 F Boiler operates in standby mode until Central Heat (CH) or Domestic Hot Water (DHW) demand detected. Access User Menu by pressing Menu key on user interface. User Menu User Menu structure. Use scroll keys to move to desired menu, and press Enter. User Menu M E N U B o i l e r S t a t u s S e t t i n g s C a s c a d e S t a t u s Boiler Status submenu Settings submenu View CH, DHW supply water set point and select control language. Cascade Status submenu Boiler set to function as part of multiple boiler installation; submenu used to view runtime parameters. See Multiple Boiler Manual. B O I L E R S T A T U S C u r r e n t S u p p l y S e t p o i n t 1 6 0 F Supply Temperature set point displayed. CH set point displayed if boiler running in CH mode. Note: Value may change in proportion to outdoor temperature when running in Outdoor Reset mode. DHW supply set point displayed if boiler is running in DHW mode. Boiler Status B O I L E R S T A T U S S u p p l y 1 4 0 F R e t u r n 1 2 0 F D H W S t a t O p e n B O I L E R S T A T U S S y s t e m N. C. F l u e 1 3 2 F O u t d o o r 3 6 F Water Temperature leaving boiler. Water Temperature entering boiler. DHW Thermostat (open or closed) System Water Temperature (if used) Vent System Temperature Outdoor Temperature (if used) B O I L E R S T A T U S B o i l e r P u m p O f f C H / S y s t e m P u m p O f f D H W P u m p O f f Heat Exchanger Pump status (On or Off) CH/System Pump status (if used, On or Off) DHW Pump status (if used, On or Off) 6

3 - Control Module User Interface Display Explanation S E T T I N G S C e n t r a l H e a t i n g S e t p o i n t F Setting Range: 104 F to 195 F (40 C to 91 C) Default Value: 140 F (60 C) S E T T I N G S Adjust CH set point to hydronic system design while in Operating in CH Mode = 0 (CH with Thermostat) or 3 (Permanent Demand). In CH Mode = 1 (CH with Thermostat and Outdoor Reset) or 2 (CH with Full Outdoor Reset). Display will change to OD Reset Setpoint and cannot be changed. Control Module calculates set point based on outdoor temperature. Settings D H W S e t p o i n t F Setting Range: 104 F to 195 F (40 C to 91 C) Default Value: 180 F (82 C) DHW set point determines supply water temperature set point when operating in DHW mode. Contact qualified agency to make changes. S E T T I N G S C h a n g e T e m p e r a t u r e U n i t s F a h r e n h e i t F Select temperature unit of measure. Fahrenheit F or Celsius C. S E T T I N G S Select user interface language. C h a n g e L a n g u a g e English E n g l i s h 7

4 - Trouble Shooting 8

5 - Maintenance! WARNING Asphyxiation hazard. Contact qualified agency if condensate trap is not filled with water. FIGURE 5-1 Condensate Drain Perform general housekeeping and maintenance as specified below. 5.1 Continuous Keep boiler area free from combustible materials, gasoline and other flammable vapors and liquids. Keep combustion air and vent terminations (outside building) free from trash, vegetation and other items capable of blocking flow. FIGURE 5-2 Safety Relief Valve Discharge Piping Safety Relief Valve 5.2 Monthly Inspect combustion air, vent, and condensate drain piping for deterioration, leaks or sagging. Contact qualified agency, as necessary. Inspect condensate drain trap inside boiler. Follow instructions TO TURN OFF GAS TO APPLIANCE. See section 2. Inspect condensate drain trap for sediment or blockage. Contact qualified agency if cleaning required. Inspect system piping for leaks. Contact qualified agency, as necessary. Check air vent(s) for leakage. Follow OPERATING INSTRUCTIONS to return to normal operation. 5.3 Check According to Manufacturer's Instructions Safety Relief Valve - Refer to manufacturer's instructions.! WARNING Burn and scald hazard. Verify Safety Relief Valve discharge piping run to safe discharge location before conducting maintenance procedure. Contact qualified agency to correct improper piping. Sy s t e m Supply FLOOR Check Local Codes For Maximum Distance To Floor Sy s t e m Return 9 5.4 Annually or Beginning Each Heating Season Contact qualified agency to perform maintenance and cleaning per Installation, Operation and Maintenance manual. Inspection will include examining all flue product carrying areas, vent system, burner and heat exchanger. Will also include filling boiler with water if drained as part of End of Heating Season procedure.

5.5 End of Heating Season, if boiler not used for domestic hot water. Follow instructions to TURN OFF GAS TO APPLIANCE. See section 2. Contact qualified agency to drain heating system (if system does not use antifreeze) and condensate trap if heating system is exposed to freezing temperatures while out of service. 5 - Maintenance 10

6 - User Service Notes 11

Installer Information Name: Address: Phone: Email: