See external label 2 C-8 C Σ=96 tests Cat # 1444Z MICROWELL ELISA. HSV 1,2 IgM. Cat # 1444Z

Similar documents
Toxoplasma gondii IgM ELISA Kit Protocol

Measles (Rubeola) IgM ELISA Catalog No. CB (96 Tests)

EBV-VCA IgA Cat #

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

IgE (Human) ELISA Kit

Revised 3 Oct rm (Vers. 16.1)

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

ELISA-VIDITEST-MICROCYSTIN LR Lot: XX

Epinephrine/Norepinephrine ELISA Kit

TRIIODOTHYRONINE (T3) ELISA Kit Protocol

Dengue IgM ELISA. For the quantitative determination of IgM-class antibodies to Dengue Virus in serum.

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Rheumatoid Factor (RF)

Anti-Zona Pellucida Antibody Latex Agglutination Test

LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

ELISA-VIDITEST anti-chlamydia trachomatis IgM

Mouse krebs von den lungen 6 (KL-6) ELISA

Anti-CENP-B (IgG) ELISA

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

Human Free Testosterone(F-TESTO) ELISA Kit

AccuDiag Lyme Disease IgG ELISA

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Cancer Antigen CA125 Human ELISA Kit

How Does a Doctor Test for AIDS?

Anti-ds-DNA-A ELISA. For the quantitative and qualitative determination of IgA antibodies against double-stranded DNA (dsdna) in human serum

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Lyme Disease IgG. Cat # Z. For in vitro diagnostic use

OneStep Fecal Occult Blood RapiDip InstaTest. Cat #

HBV Quantitative Real Time PCR Kit

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit

Anti-ss-DNA Screen (IgA, IgG, IgM) ELISA

QuickTiter Hepatitis B Surface Antigen (HBsAg) ELISA Kit

Lyme disease IgG / IgM

Rat Fibronectin ELISA Kit

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Genscreen ULTRA HIV Ag-Ab Number: PQDx Abstract

ab Albumin Human ELISA Kit

Dehydroepiandrosterone Sulfate ELISA (DHEA-S)

Malondialdehyde (MDA) ELISA

ab Free Testosterone ELISA Kit

Anti-dsDNA Cat # 2553Z

ab Complement C1q Human ELISA Kit

Anti-M2 (IgG) ELISA. For the quantitative and qualitative detection of antibodies against M2 in serum.

Bovine Vitamin B12 (VB12) ELISA Kit

HUMAN FREE THYROXINE (FT4) ELISA. Product Data Sheet. Cat. No.: RCAN-FT4-4340R. For Research Use Only. Page 1 of 16 VERSION

CeliCheck (Tissue Transglutaminase IgA/IgG) ELISA

QuickTiter FeLV Core Antigen ELISA Kit (FeLV p27)

Serum Testosterone ELISA

Free Testosterone. Cat# 2924Z. Direct immunoenzymatic determination of Free Testosterone in serum or plasma. Free Testosterone ELISA Method

Tick-Borne Encephalitis (TBE/FSME) Virus IgG Human ELISA Kit

Human TNF- Product #

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

Uscn Life Science Inc. Wuhan

Testosterone (Pig) ELISA Kit

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

Cortisol (Saliva) ELISA

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.

CatCombi Research ELISA Kit

Free Testosterone Cat# 2924Z

Rat Anti-KLH Rat IgM ELISA Kit

QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company

ELISA-VIDITEST anti-cmv IgM capture

WIESLAB Complement system

QUANTA Lite TM CCP 3.1 IgG/IgA ELISA For In Vitro Diagnostic Use CLIA Complexity: High

ab Anti- Borrelia burgdorferi IgM Human ELISA Kit

竞 争 性 分 析 Epitope Mapping 实 验 方 法

Borrelia burgdorferi IgM Human ELISA Kit

Albumin ELISA Kit. Albumin ELISA Kit. Zur in vitro Bestimmung des Albumin in Urin und Stuhl

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

CA19-9. Enzyme immunoassay for the quantitative determination of CA19-9 in human serum or plasma Only for in-vitro diagnostic use

Human Parathyroid Hormone (PTH) ELISA Kit

B.burgdorferi (Lyme disease) IgG IFA Kit

Lyme (IgG and IgM) Antibody Confirmation

Free Testosterone ELISA

Lyme Disease IgM. Cat # Z. For in vitro diagnostic use

SUMMARY AND EXPLANATION OF THE TEST

Reagents Quantity Reagents Quantity. Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4. Standard 2 Standard Diluent 1 20mL

AccuDiag HCV Ab ELISA

QUANTA Lite TM RF IgM ELISA For In Vitro Diagnostic Use CLIA Complexity: High

ab Anti-Tick-borne encephalitis (TBE) virus IgM Human ELISA Kit

Qualification Study CHO 360-HCP ELISA (Type A to D)

ab Anti-Tick-borne encephalitis (TBE) virus IgG Human ELISA Kit

Thrombin Generation Assay

Content: 1) Intended use 2) Design Theory/ Brief Description of the Product 3)

Please use only the valid version of the package insert provided with the kit.

Ovarian Cancer Antigen CA125 ELISA Kit Protocol. (Cat. No.:EK )

ab Protein Sumoylation Assay Ultra Kit

BHV-1 SEROCONVERSION ELISA KIT

ab Anti-Borrelia burgdorferi IgG Dog ELISA Kit

JE Detect TM IgM ANTIBODY CAPTURE ELISA (MAC-ELISA)

Micro-Albumin ORG 5MA. 96 Tests. Enzyme Immunoassay for the quantitative determination of Albumin in urine. Instruction for use

> IGF-1 (human) Table of Contents. Catalog # Well Enzyme Immunoassay Kit For use with human serum and plasma

Mouse IFN-gamma ELISpot Kit

IP-10 ELISA KIT INTENDED USE

AccuDiag Lyme Disease IgM ELISA Kit

Transcription:

DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external label 2 C-8 C Σ=96 tests Cat # 1444Z MICROWELL ELISA HSV 1,2 IgM Cat # 1444Z NAME AND INTENDED USE The DIAGNOSTIC AUTOMATION ELISA, HSV 1,2 IgM is intended for the detection of IgM antibodies to herpes simplex virus (HSV) 1 and 2. SUMMARY AND EXPLANATION OF THE TEST Herpes Simplex Virus is a common pathogen and its primary infection is usually asymptomatic. There are two immunologically distinct types of HSV: Type 1 and Type 2. HSV 1 is generally associated with oral infection and lesions above the waist, and HSV 2 is associated with genital infections and lesions below the waist. Clinical cases primarily are 1) eczema herpeticum with eczematous skin changes with numerous lesions, 2) Gingivostomatitis and 3) Herpes sepsis, almost only found in newly born of premature infants. DIAGNOSTIC AUTOMATION ELISA HSV IgM is an accurate serologic method to detect HSV specific antibody IgM in serum sample. PRINCIPLE OF THE TEST Purified HSV antigen is coated on the surface of microwells. Diluted patient serum is added to wells, and the HSV IgM specific antibody, if present, binds to the antigen. All unbound materials are washed away. After adding enzyme conjugate, it binds to the antibody-antigen complex. Excess enzyme conjugate is washed off and TMB Chromogenic substrate is added. The enzyme conjugate catalytic reaction is stopped at a specific time. The intensity of the color generated is proportional to the amount of IgM specific antibody in the sample. The results are read by a microwell reader compared in a parallel manner with calibrator and controls. DAI Code # 11 1

MATERIALS PROVIDED 1. Microwell Strips: purified HSV 1,2 antigen coated wells. (12 x 8 wells) 2. Absorbent Solution: Black Cap. 1 vial (22 ml) 3. Washing Concentrate 10x: White Cap. 1 bottle (100 ml) 4. TMB Chromogenic Substrate: Amber bottle. 1 vial (15 ml) 5. Enzyme Conjugate: Red color solution. 1 vial (12 ml) 6. Cut-off Calibrator: Yellow Cap. HSV 1,2 M Index = 1.0 1 vial (150 µl) 7. Negative Control: Range stated on label. Natural Cap. 1 vial (150 µl) 8. Positive Control: Range stated on label. Red Cap. 1 vial (150 µl) 9. Stop Solution: 2 N HCl. 1 vial (12 ml) STORAGE AND STABILITY 1. Store the kit at 2-8 C. 2. Always keep microwells tightly sealed in pouch with desiccants. We recommend you use up all wells within 4 weeks after initial opening of the pouch. 3. The reagents are stable until expiration of the kit. 4. Do not expose test reagents to heat, sun or strong light during storage or usage. WARNINGS AND PRECAUTIONS 1. Potential biohazardous materials: The calibrator and controls contain human source components which have been tested and found nonreactive for hepatitis B surface antigen as well as HIV antibody with FDA licensed reagents. However, as there is no test method that can offer complete assurance that HIV, Hepatitis B virus or other infectious agents are absent, these reagents should be handled at the Biosafety Level 2, as recommended in the Centers for Disease Control/National Institutes of Health manual, "Biosafety in Microbiological and Biomedical Laboratories." 1984 2. Do not pipette by mouth. Do not smoke, eat, or drink in the areas in which specimens or kit reagents are handled. 3. The components in this kit are intended for use as a integral unit. The components of different lots should not be mixed. 4. This product contains components preserved with sodium azide. Sodium azide may react with lead and copper plumbing to form explosive metal azide. On disposal, flush with a large volume of water. SPECIMEN COLLECTION AND HANDLING 1. Collect blood specimens and separate the serum. 2. Specimens may be refrigerated at 2-8 C for up to seven days or frozen for up to six months. Avoid repetitive freezing and thawing of serum sample. PREPARATION FOR ASSAY 1. Prepare 1x washing buffer. Prepare washing buffer by adding distilled or deionized water to 10 x wash concentrate to a final volume of 1 liter. 2. Bring all specimens and kit reagents to room temperature (20-25 C) and gently mix. DAI Code # 11 2

ASSAY PROCEDURE 1. Place the desired number of coated strips into the well holder. 2. Prepare 1:40 dilutions by adding 5 µl of the test samples, negative control, positive control, and calibrator to 200 µl of absorbent solution. Mix well. 3. Dispense 100 µl of diluted sera, calibrator, and controls into the appropriate wells. For the reagent blank, dispense 100 µl absorbent solution in 1A well position. Tap the holder to remove air bubbles from the liquid and mix well. Incubate for 30 minutes at room temperature. 4. Remove liquid from all wells and repeat washing three times with washing buffer. 5. Dispense 100 µl of enzyme conjugate to each well and incubate for 30 minutes at room temperature. 6. Remove enzyme conjugate from all wells. Repeat washing three times with washing buffer. 7. Dispense 100 µl of TMB Chromogenic Substrate to each well and incubate for 30 minutes at room temperature. 8. Add 100 µl of 2 N HCl to stop reaction. Make sure there are no air bubbles in each well before reading 9. Read O.D. at 450 nm with a microwell reader. CALCULATION OF RESULTS 1. Calculate the mean of duplicate calibrator value x c. 2. Calculate the mean of duplicate positive control, negative control and patient samples. 3. Calculate the HSV 1,2 M Index of each determination by dividing the mean values of each sample by calibrator mean value, x c. Example of typical results: Cut-off Calibrator HSV 1,2 M Index = 1 Calibrator O.D. = 0.358, 0.365 x c = 0.362 Negative control O.D.= 0.158, 0.162 x n = 0.160 HSV 1,2 M Index = 0.160 / 0.362 = 0.44 Positive control O.D. = 1.305, 1.346 x p = 1.326 HSV 1,2 M Index = 1.326 / 0.362= 3.66 Patient sample O.D. = 1.409, 1.459 x s = 1.434 HSV 1,2 M Index = 1.434 / 0.362 = 3.96 QUALITY CONTROL The test run may be considered valid provided the following criteria are met: 1. The O.D. value of the reagent blank against air from a microwell reader should be less than 0.250. 2. If the O.D. value of the Calibrator is lower than 0.250, the test is not valid and must be repeated. 3. The HSV 1,2 M Index for Negative and Positive Control should be in the range stated on the labels. DAI Code # 11 3

INTERPRETATION Negative: HSV 1,2 M Index less than 0.90 are negative for IgM antibody to HSV 1,2. Equivocal: HSV 1,2 M Index between 0.91-0.99 is equivocal. Sample should be retested. Positive: HSV 1,2 M Index of 1.00 or greater are positive for IgM antibody to HSV 1,2. PERFORMANCE CHARACTERISTICS Precision: The precision of the assay was evaluated by testing three different sera of eight replicates over a period of one week. The intra-assay and inter-assay C.V. are summarized below: Negative Low positive Positive Intra-assay 8.2% 7.2% 6.3% Inter-assay 9.1% 8.2% 6.5% LIMITATION OF THE PROCEDURE 1. To prevent false negative and false positive IgM test results caused by the presence of specific IgM and rheumatoid factor (RF) in some specimens, reagents provided in this kit has been formulated to resolve these interferences. However, specimens with extremely high RF and high autoimmune antibodies, the possibility of these interferences cannot be ruled out entirely. 2. As with other serological assays, the results of these assays should be used in conjunction with information available from clinical evaluation and other diagnostic procedures. 3. A negative serological test does not exclude the possibility of past infection. Following primary HSV infection, antibody may fall to undetectable levels and then be boosted by later clinical infection with the same or heterologous type. Such a phenomenon may lead to incorrect interpretations of seroconversion and primary infection, or negative antibody status. In addition, samples obtained too early during primary infection may not contain detectable antibody. Some persons may fail to develop detectable antibody after Herpes infection. REFERENCES 1. Nahmias, A.J., J. Dannenbarger, C. Wickliffe and M. Muther. Clinical aspects of infection with herpes simplex viruses 1 and 2 in the human herpes viruses. An interdisciplinary Perspective (Nahmias, A.J., W.R. Dawdle and R.F. Schinazi eds) New York, Elsevier, pp 3-9, 1981. 2. Vestergaard, B.F., P.C. Grauballe and H. Spanggaard. Titration of herpes simplex virus antibodies in human sera by the enzyme-link immunosorbent assay (ELISA). Acta Pathol. Microbiol. Scand. Sect. B 85:446-448, 1977. 3. Coleman, R.M., L. Pereira, P.D. Bailey, D. Dondero, C. Wickliffe, and A.J. Nahmias. Determination of herpes simplex virus type-specific antibodies by enzyme-linked immunosorbent assay. J. Clin. Microbiol. 18(1983) 287. DAI Code # 11 4

SUMMARY OF ASSAY PROCEDURE Step (20-25 C Room temp.) Volume Incubation time 1 Sample dilution 1:40 = 5 µl / 200 µl 2 Diluted samples, controls & calibrator 100 µl 30 minutes 3 Washing buffer (3 times) 350 µl 4 Enzyme conjugate 100 µl 30 minutes 5 Washing buffer (3 times) 350 µl 6 TMB Chromogenic Substrate 100 µl 30 minutes 7 Stop solution 100 µl 8 Reading OD 450 nm Date Adopted Reference No. 2005-08-17 DA-HSV 1,2 IgM-2008 DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 ISO 13485-2003 Revision Date: 8/26/08 DAI Code # 11 5