s!nus-elektrotechnikai bt. Industrial IT & Automation



Similar documents
s!nus-elektrotechnikai bt. Industrial IT & Automation

s!nus-elektrotechnikai bt. Industrial IT & Automation

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

1-Port R422/485 Serial PCIe Card

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

M-Bus Network Installation Notes

Bluetooth HC-06 with serial port module Easy guide

Bluetooth to Serial Adapter

ScanWin Installation and Windows 7-64 bit operating system

Turbovex TX Modbus configuration guide

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

USB PC Adapter V4 Configuration

Installing the drivers for the Current Cost Data Cable

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

The technical aspects of V90 or V92 on two analogue telephone lines (both side PSTN) or a so called a point to point connections.

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

Siemens S7-200PLC Ethernet Adapter ES-ETH-PPI USER MANUAL

PMS. Energy management and monitoring software. Installation and operation instructions

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

ATS Communication Overview

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

LBNP RS-232/485/422 serial device server. User manual

PP8X Printer Driver Installation Instruction

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

USB Plus+ RFID Reader Setup Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

USB Driver Installation for Windows XP

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Using HyperTerminal with Agilent General Purpose Instruments

ADACSNET USB Control Module

Schneider OS-Loader usage via Ethernet or USB.

Professional USB to Serial Adapter Hub with COM Retention

ACR120 Technical Specifications version 2.9 November 2005

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

UDG1000 Hach PCX2200 Serial Port Input Driver configuration

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Communication with BushingGard using computer USB port

IntesisBox Modbus Server Fidelio IP

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

User Manual IC-485AI

Universal Serial Bus (USB) to DH-485 Interface Converter

Select Correct USB Driver

Table of Contents. Creating a VC1000 Network... 3

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

IP SERIAL DEVICE SERVER

DSX Master Communications

1 Serial RS232 to Ethernet Adapter Installation Guide

Connecting instruments serially to your computer

Application/Connection Examples

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Bluetooth to serial HC-06 wireless module

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Guide to Installing BBL Crystal MIND on Windows 7

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

USBSPYDER08 Discovery Kit for Freescale MC9RS08KA, MC9S08QD and MC9S08QG Microcontrollers User s Manual

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

How To Operate Loader On A Microsoft Powerbook 2.5 (Powerbook) With A Powerbee 2.2 (Powerbee) And Powerbee 3.5 Powerbee (Powerbore) (Powerboard) (Operating

POS Integration. Prepared by: Binh Nguyen

WinLIN Setup and Operation:

USB to RS-422/485 Serial Adapter

Model DFG-RSA Configurable Load Cell Adapter

Installing the Gerber P2C Plotter USB Driver

HP-1000 Powerline USB Adapter

GV- RK1352 Card Reader

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

WindO/I-NV2 Utility Pass-Through Tool

Why you need to monitor serial communication?

Centurion PLUS CPC4 Download Guide

HP-1000 Powerline Ethernet Adapter

USB TO SERIAL CONVERTER

TECHNICAL NOTE TNOI32

RS-232/422/485, Power over Ethernet

Cable Connection Procedures for Cisco 1900 Series Routers

Bluetooth UART/RS232 Module

2-Port RS232/422/485 Combo Serial PCI Card

PMS. Energy management and monitoring software. Installation and operation instructions. BMR trading Horní lán Olomouc Czech Republic

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook

Config software for D2 systems USER S MANUAL

Serial over Ethernet Device Server. User s Manual

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Transferring Scans from your Dolphin into Destiny

UCC 1 USB-CAN CONVERTER

Serial to Bluetooth Adapter

Software User Guide UG-461

HSG Engineering Tech Bulletin

Manual. Sealer Monitor Software. Version

One Port Serial Server Users Manual Model ESP901, ESP901E

DUKANE Intelligent Assembly Solutions

GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854

Installing the IF-NMEASC & SC30 Windows XP Drivers & Software

MANUAL FOR RX700 LR and NR

Transcription:

USER MANUAL s!nus-elektrotechnikai bt. USB/PPIM+ Siemens S7-200 USB/PPI Multi-Master Cable USB/RS485 Isolated For all PPI-Bus System Summary: USB / PPIM + is the PPI Multi-Master programming Cable which with USB interface, to realize the level conversion and various of PPI protocol conversion from USB to RS485.Many cheap USB / PPI cable on the market simulate USB to virtual serial (COM port) to realize the communications, it s commonly known as "pseudo-usb interface". The cable only convert the level from USB to RS485, can only support the normal PPI Protocol. But the USB / PPIM + is the real USB interface cable, without installing drivers, directly use the USB option in STEP7 Micre / WIN software, support PPI, Advanced PPI,and Multiple Master Network Protocol. The cable support the 187.5 Kbps high-speed communications, and take charge of the Multiple Master Network. This cable is 100% compatible with Siemens PPI Multi-Master USB Cable 6 ES7 901-3DB30-0XA0, and the only difference is that the work power supply from the computer's USB port through the DC / DC isolation, no longer powered by the PLC port. It s easy to extend communications distance of the RS485 without considering the power supply. The two-color LED on the converter box indicates data s transceiving status. USB/PPIM+ is designed for industrial-type photoelectric isolation cable. USB port and RS485 ports are equipped with surge protection and anti-lightning protection circuitry, which can be Hot plug. It s applicable to the entire Siemens S7-200 Series PLC It s particularly suited to the industrial scene which the communications interface is more easily damaged because of the greater interference. The protection circuit ensures the safe operation of the system.

Outline configuration: signals definition of the RS485-Block (DB9M) of the USB/PPIM+ pin signal Description 3 RxD/TxD+ Data Line B (RS485 signal positive) 8 RxD/TxD- Data Line A (RS485 signal negative) 5 GND DGND Features and technological index: support USB / PPIM + operating system: Windows2000/Windows XP support USB / PPIM + programming software version: STEP7 Micro / WIN V4.0 and above, without installing drivers, directly use the USB option in Local Connection. USB is fully compatible with USB V1.1 norms and USB V2.0 USB bus-powered, 5 VDC, the power consumption is about 100 ma, with over current protection

optical isolation voltage: 1000 VDC (up to 3000 VDC, it should be declared when making an order) USB port with anti-surge protection, RS485 port with 500 W anti-lightning protection and over current protection support PPI baud rate: 9.6 Kbps, 19.2Kbps, 187.5Kbps support the communication protocol: PPI, senior PPI, multi-master PPI. support long-distance communications, the largest communications distance is 2,000 meters (9.6 Kbps) or 1 km(187.5kbps). each PC only supports a USB cable programming temperature: -20 ~ +75 Cable length: three meters, colors: black Usage: 1, Enter STEP7 Micro / WIN programming software and click "Settings PG / PC interface", check the "PC / PPI cable (PPI)" and click "Properties " button. 2,Select "USB" option in "Local Connection". 3, Set up the Station Parameters settings in "PPI" as following: Address: 0, Timeout: 1s. Set up the Network Parameters in "PPI" in accordance with the needs of you. You can choose any of the following: Advanced PPI: check the Advanced PPI. Multiple Master Network: check Multiple Master Network. General PPI: do not check any of option, which is the default option. select a baud rate as the same with the PLC. If you do not know that the PLC baud rate can be arbitrary choice one.

Click "OK" button to return to the main menu interface. s!nus-elektrotechnikai bt. 4, click on the main menu interface of "communication" button to enter the PLC interface connection, check the "search all baud rate" box, and then double-click on the "Double-click refresh. After a while of searching,the PLC model And address and other information will display on the software, it s means that connect successfully with the PLC. Click the "confirmation" button to conduct upload, download, and other operating. PPI Multi-Master Cable of USB/PPIM+ no longer support the early version of the low CPU21X series PLC. PPI Multi-Master Cable of USB/PPIM+ do not support Freeport communication and MODEM communication. Long-distance communications: The largest communications range between the USB/PPIM+ and PLC are up to 2 kilometers (9.6K bps) or 1 km(187.5kbps),when external plus terminals 120 ohm resistance is needed to connect between the pin3 and pin8 of the RS485 ports (DB9 Male) to eliminate signal reflection. And a PFB-G Bus Isolators is needed to install at the end of PLC. 0.22 mm2 or more unshielded twisted pair lines are used for Communications. When the distance is

longer than the length of cable, a RS485 repeaters (model: E485GP), can be installed in the bus for extending the distance. Because the power of USB / PPIM + all supplied from the USB ports of the computer, you do not need to consider power supply when extended the length of cable. It s better than the similar products of Siemens. Please Note: USB interface cable cannot be extended.