STANDBY 200 ekw 250 kva

Similar documents
STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

How To Use A Cat Diesel Engine

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

C18 Diesel Oilfield Generator Set

DIESEL GENERATOR SETS

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

C18 ACERT Fire Pump Tier bkw/ rpm

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

3516 Industrial Engine

Diesel Engine Driven Generators Page 1 of 6

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Diesel Generating Set

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

Spark-ignited generator set

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFMB 60 Hz

How To Control A Power Command Powerplant

Diesel Generator Set Model DGDK 60 Hz

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

INDUSTRIAL ENGINE RATINGS GUIDE

3516B Offshore Generator Set

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Magnum Mobile Generator MMG55 Specifications

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Atlas Copco Generators

3516B Offshore Emergency Generator Set

CAT CG132. Series Gas Generator Sets

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Annex-A TECHNICAL SPECIFICATION

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

X G R E N T A L

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Technical Specification. Generating Set with Waukesha engine burning natural gas

APS100 Rental Generator Set Specification

Marine Generating Sets 3.7 to 50 kva

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

IGSA POWER GENERATION SYSTEMS

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED

Integrated Power Systems for Data Centers

Power Generation generator sets kva to 15 MW

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

LOAD BANK TESTING PROCEDURE

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Commercial Marine Generators

The kva RAnge

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

an EnPro Industries company POWERSolutions

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

HEAVY-DUTY, REDEFINED. REDEFINED.

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

PM734F - Technical Data Sheet Winding 28

Fire Pump Plan Review March 2010

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

POWER GENERATION.

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

POWER YOUR TELECOM SITE WITH OLYMPIAN Hybrid Power for Telecom Applications Solar Photovoltaic Wind Diesel Battery

Explosion-Proof Electric Unit Heaters

Power Your Telecom site with olympian Hybrid Power for Telecom Applications Solar Photovoltaic Wind Diesel Battery

EMERGENCY AND STANDBY POWER SYSTEMS

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Centro-Matic Automatic Lubrication Systems System Controls

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Top Technology for Industry, Agriculture, Business and Communities

Specifications for Volkswagen Industrial Engine

Medical Air Systems: Scroll

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

304C CR Mini Hydraulic Excavator

VM 32. Efficiency and Performance New Product Development Modular Design Cylinder

Transcription:

DIESEL GENERATOR SET STANDBY 200 ekw 250 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered reliability, and cost-effectiveness. Image shown may not FEATURES FUEL/EMISSIONS STRATEGY (Emits Equivalent U.S. EPA Tier 3 Nonroad Standards) DESIGN CRITERIA The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response Cooling system designed to operate in 50 C / 122 F restriction of 0.5 in. water UL 2200 / CSA Optional UL 2200 Listed Certain restrictions may apply. Consult with your Cat Dealer. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries The Cat SOS SM program cost effectively detects internal engine component condition, even the by-products CAT C9 ATAAC DIESEL ENGINE Utilizes ACERT Technology Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Electronic controlled governor CAT GENERATOR Matched to the performance and output characteristics of Cat engines UL 1446 Recognized Class H insulation CAT EMCP 4 CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway Integrated Voltage Regulation SEISMIC CERTIFICATION* dependent on many factors such as generator set size, weight and concrete strength. used is reviewed and approved by a Professional Engineer IBC 2000, IBC 2003, IBC 2006, IBC 2009, IBC 2012, CBC 2007, CBC 2010 *Not available with some options consult with your Cat Dealer.

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Disposable air filter [ ] Canister type, dual element [ ] Heavy duty air cleaner Cooling Package mounted radiator Exhaust Exhaust flange outlet [ ] Industrial [ ] Residential / Critical Fuel Generator Primary fuel filter with integral water separator Secondary fuel filters Fuel priming pump Matched to the performance and output characteristics of Cat engines IP23 Protection [ ] Permanent magnet excitation (PMG) [ ] Anti-condensation space heater [ ] Coastal insulation protection [ ] Internal excitation (IE) / AREP Power Termination Power terminal strips [ ] Circuit breakers 100% rated assembly, UL Listed [ ] SUSE (Suitable for use as service equipment) Control Panels EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4 [ ] Local and remote annuniciator modules [ ] Remote monitoring software Mounting Starting/Charging General Rubber vibration isolators 24 volt starting motor & charging alternator Batteries Paint Caterpillar Yellow except rails and radiators gloss black Narrow skid base [ ] Battery chargers [ ] Oversize batteries [ ] Jacket water heater The following options are based on regional and product configuration: [ ] Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, IBC 2012, CBC 2007, CBC 2010 [ ] UL 2200 Listed package [ ] CSA Certified [ ] Wide skid base [ ] Sound attenuated enclosure [ ] Weather protective enclosure [ ] Integral dual wall UL Listed 8 hr fuel tank [ ] Sub-base dual wall UL Listed 24 hr fuel tank [ ] Sub-base dual wall UL Listed 48 hr fuel tank 2

SPECIFICATIONS STANDARD CAT GENERATOR Frame size LC5014F Excitation Self Excitation Pitch 0.6667 Number of poles 4 Number of bearings Single bearing Number of leads 12 Insulation UL 1446 Recognized Class H IP Rating IP23 Alignment Pilot shaft Overspeed capability (%) 125 Wave form deviation (%) 2 Voltage regulator Three phase sensing Voltage regulation +/- 0.25% (steady state) Consult your Cat dealer for available voltages CAT DIESEL ENGINE C9 ATAAC, I-6, 4-Stroke Water-cooled Diesel Bore 112.00 mm (4.41 in) Stroke 149.00 mm (5.87 in) Displacement 8.80 L (537.01 in 3 ) Compression ratio 16.1:1 Aspiration Air-to-air aftercooled Fuel system Hydraulic electronic unit injection Governor type Caterpillar ADEM control system CAT EMCP 4 SERIES CONTROLS EMCP 4 controls including: - Run / Auto / Stop Control - Speed and Voltage Adjust - Engine Cycle Crank - 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions Digital indication for: - RPM - DC volts - Operating hours - Oil pressure (psi, kpa or bar) - Coolant temperature - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - ekw, kva, kvar, kw-hr, %kw, PF (4.2 only) Warning/shutdown with common LED indication of: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Programmable protective relaying functions: - Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kw) (32) (4.2 only) - Reverse reactive power (kvar) (32RV) - Overcurrent (50/51) Communications: - Four digital inputs (4.1) - Six digital inputs (4.2 only) - Four relay outputs (Form A) - Two relay outputs (Form C) - Two digital outputs - Customer data link (Modbus RTU) (4.2 only) - Accessory module data link (4.2 only) - Serial annunciator module data link (4.2 only) - Emergency stop pushbutton Compatible with the following: - Digital I/O module - Local Annunciator - Remote CAN annunciator - Remote serial annunciator 3

TECHNICAL DATA Open Generator Set - - 1800 rpm/60 Hz/480 Volts EM0095 EPA Certified for Stationary Emergency Application (Emits Equivalent U.S. EPA Tier 3 Nonroad Standards) Generator Set Package Performance Genset power rating @ 0.8 pf Genset power rating with fan Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System 1 Air flow restriction (system) Air flow (max @ rated speed for radiator arrangement) Engine coolant capacity with radiator/exp. tank Engine coolant capacity Radiator coolant capacity 58.2 L/hr 46.6 L/hr 34.9 L/hr 0.12 kpa 600 m³/min 46.7 L 22.0 L 24.7 L 250 kva 200 ekw 15.4 gal/hr 12.3 gal/hr 9.2 gal/hr 0.48 in. water 21189 cfm 12.3 gal 5.8 gal 6.5 gal Inlet Air Combustion air inlet flow rate 22.0 m³/min 777 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator 2 Motor starting capability @ 30% voltage dip Frame Insulation class Temperature rise 436 C 53.8 m³/min 127.0 mm 10.0 kpa 87 kw 277 kw 58 kw 14 kw 15.7 kw 454 skv LC5014F H 130 C 234 F 816 F 1900 cfm 5.0 in 40.1 in. water 4948 Btu/min 12909 Btu/min 3298 Btu/min 796 Btu/min 893 Btu/min Lubrication System Sump refill with filter 39.0 L 10.3 gal Emissions (Nominal) 3 NOx g/hp-hr CO g/hp-hr HC g/hp-hr PM g/hp-hr 2.52 g/hp-hr 0.33 g/hp-hr 0.11 g/hp-hr 0.046 g/hp-hr 1 For site specific ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2 Generator temperature rise is based on a 40º C (104º F) ambient per NEMA MG1-32. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77ºF, 28.42 in HG and number 2 diesel fuel with 35º API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. 4

RATING DEFINITIONS AND CONDITIONS Applicable Codes and Standards: AS1359, CSA C22.2 No100-04, UL142,UL489, UL869, UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG1-22,NEMA MG1-33, 72/23/EEC, 98/37/ EC, 2004/108/EC. Standby Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel Rates are based on fuel oil of 35 API (16 C or 60 F) gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29 C (85 F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional Ratings may be available for specific customer requirements. Consult your Cat representative for details. 5

DIMENSIONS Package Dimensions Length 2870 mm 113.0 in Width 1622 mm 63.9 in Height 2065 mm 81.3 in NOTE: For reference only do not use for installation design. Please contact your local dealer for exact weight and dimensions. Performance No.: EM0095 Feature Code: C09DE46 Gen. Arr. Number: 449-0597 Source: U.S. Sourced (02/14) www.cat-electricpower.com 2014 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the Power Edge trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. 6