For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.



Similar documents
Information Note Connecting a BRI - checklist

Initial configuration Vega 400 E1/T1 (H.323) Gatekeeper Mode R7

Initial configuration Vega 400 E1/T1 (SIP)

Configuring the ADTRAN ATLAS for a Rabbit-Hole Application

ISDN Troubleshooting October 11, 2012

NEC 2400 IMS --- T1 PRI

Mediatrix 4404 Step by Step Configuration Guide June 22, 2011

Troubleshooting the Cisco Unified Videoconferencing 3500 Gateway

TFM GSMRoute BRI. Quick Installation Guide

Imecom White Paper. T1/PRI Configuration for the Imecom DM Fax Server with Brooktrout TR1034 Digital Fax Board(s)

OfficeMaster SBA (Survivable Branch Appliance)

LifeSize Networker Installation Guide

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

TECH ARTICLE Date: 03/04/08

Cisco T1 Layer 1 Troubleshooting

In the following installation procedures, do not disconnect the Mediatrix 3000 Series while the LEDs are flashing.

Allo PRI Gateway and Elastix Server

PRImaGate Switch RACK 3U

Automatic Routing of Inbound Faxes With Castelle Network Fax Servers. Fractional T1, Full T1, Fractional E1, Full E1, ISDN, DID and PBX Integration

VegaStream Information Note T.38 protocol interactions

SIP Trunking using Optimum Business SIP Trunk Adaptor and ShoreTel IP PBX Phone System

Quick Installation Guide

VegaStream PSTN Gateways and pbxnsip

Alti-Mobile Extensions

Information Note Syslog

Atlas Event Logging Explanation

Automatic Routing of Inbound Faxes with Open Text Network Fax Servers

Application Note - IP Trunking

AudioCodes Mediant 1000 Configuration Guide

OmniAccess 5320 BG. Business Gateway. User s Guide

GSM GATEWAY PRI / E1 RACK 3U

Voice Dial Plans, Configuring Voice Interfaces and Dial Peers

Inbound Routing with NetSatisFAXTion

P-2602HWNLI. Quick Start Guide g Wireless ADSL2+ 4-port VoIP IAD. Version /2007 Edition 2

Troubleshoot your ADSL Router/Modem Setup

Link Gate SIP. (Firmware version 1.20)

Should still mention E1 since it is mentioned above maybe something like E1 lines can be supported under special arrangement.

Grandstream Networks, Inc. How to Configure T1 Trunk on UCM6510

Channelized E1 and Channelized T1 Setup Commands

How to Config MTG1000B With T1 and Elastix

Digital Trunks. Objectives. When you finish this module, you will: Understand the different types of digital trunks.

Table of Contents. Cisco Mapping Outbound VoIP Calls to Specific Digital Voice Ports

Integrating Citrix EasyCall Gateway with SwyxWare

Vega 100G and Vega 200G Gamma Config Guide

Release Notes for NeoGate TE X

Application Notes for Configuring QuesCom 400 IP/GSM Gateway with Avaya IP Office using H.323 trunks Issue 1.0

SIP Trunking with Elastix. Configuration Guide for Matrix SETU VTEP

Mediatrix Gateway 440x Series Quick Configuration Guide

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

cpci cfxo3120 FXO/FXS VoIP Gateway

Installation and setup guide V 1.0

Model PBX 308 Plus System Administration Guide

Extend the Life of Your Legacy PBX while Benefiting from SIP Trunks. December 5, 2013

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Connecting Sipura ATAs to a legacy PBX System.

Configuring Analog and Digital Voice Interfaces

Telephone User Guide

How To. Configure E1 links. Introduction. What information will you find in this document?

Digital Phone Installation & User Guide

Feature Description: Situation: Feature: Redirecting Number Information Element (RNIE)

Configuring Network Side ISDN PRI Signaling, Trunking, and Switching

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Allworx 6x IP PBX

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

MAXCS Release 7.0. Application Note: Remote MultiVoIP Gateway Configuration. Intended audience: AltiGen Authorized Partners

Model PBX 308 Plus System Administration Guide

How To Configure An African Atlas

2N NetStar. 2N NetStar as a PBX Booster. Quick guide. Version 1.00

System Administration Guide. Model KS 832. Expandable up to 1664

2100 Series VoIP Phone

Application Notes for Configuring Cablevision Optimum Voice SIP Trunking with Avaya IP Office - Issue 1.1

VegaStream Information Note Considerations for a VoIP installation

DPH-50U VoIP USB Phone Adapter Quick User Guide

White Paper Integration of TTY Calls into a Call Center Using the Placeholder Call Technique Updated: February 2007

Quick Configuration Guide L1-42.1B January 2009

Getting Started KX-TDA5480

1. Overview. 2. F-bit Utilization

Welcome. Unleash Your Phone

MyPBX U510 Installation Guide

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490

Vertex VoIP Caller ID (Version 1.5)

Model PBX 206 System User Guide

EZLoop IP-PBX Enterprise SIP Server

Avaya IP Office 8.1 Configuration Guide

Application Notes Rev. 1.0 Last Updated: February 3, 2015

Configuring SIP Trunking and Networking for the NetVanta 7000 Series

Integrating VoIP Phones and IP PBX s with VidyoGateway

P-2602HWNLI. Quick Start Guide g Wireless ADSL2+ 4-port VoIP IAD. Version /2006 Edition 1

General Guidelines for SIP Trunking Installations

ISDN Diagnostic Codes

Model PBX 416 Plus System Administration Guide

General Guidelines for SIP Trunking Installations

Troubleshooting Tools to Diagnose or Report a Problem February 23, 2012

BRI to PRI Connection Using Data Over Voice

User Manual for the OPERA E1/T1 Option OPR-002-E1T-P

1) How do I setup my SIP trunk for inbound/outbound calling? We authenticate IP-PBX SIP Trunking traffic by:

Application Notes Rev. 1.0 Last Updated: January 9, 2015

intelligence at the edge of the network EdgeBOX V 4.5 VoIP How To

Application Notes for Configuring Microsoft Office Communications Server 2007 R2 and Avaya IP Office PSTN Call Routing - Issue 1.0

Your Technical Point of Contact s Role

IP PBX. SD Card Slot. FXO Ports. PBX WAN port. FXO Ports LED, RED means online

Transcription:

Information Note Connecting a T1 / E1 - checklist When connecting a Vega to a T1 or E1 connection there are a number of steps that need to be followed in order to ensure that the link will come up and the system will operate correctly. Trunk interface (DSL) configuration For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE. For example the PSTN/ISDN will be NT NeTwork and the trunk interfaces of a PBX will be TE Terminal Equipment. PSTN / ISDN NT TE pbx For a Vega to operate correctly, it must have its trunks configured NT / TE appropriately; NT if it is to connect to a TE device and TE if it is to connect to an NT device. By default Vega gateways are configured with alternate trunks configured TE and NT, IF:01 = TE, IF:02 = NT, etc. so often it is possible to use default Vega configuration. (If you need to change the configuration, see the appropriate step-by-step initial configuration guide) Version 1.0 5 July 2006 Page 1 of 8

Framing E1: Ensure that on the web browser DSL page that the choice of CRC4 / PCM30 (no CRC4) is made. This is a per-unit value and so only needs to be made once. Typically CRC4 should be selected as per the Q.931 specification. In France and Sweden (and occasionally elsewhere, e.g. on Alcatel PBXs) CRC4 is not used, and PCM30 should be selected. T1: Ensure that on the web browser DSL page that the choice of ESF / SF is made. This is a per-unit value and so only needs to be made once. ESF is the more modern and more commonly used framing. This is typically used with B8ZS line encoding. Network type and other parameters See a relevant step-by-step initial configuration guide Hardware connectivity Use the diagrams in Annex 1 to correctly wire in your Vega 400 or Vega 100. Note Vega 100 uses different cables depending on whether a trunk is being connected to an NT or a TE device. Vega 400 however carries out the pinout switching internally and so only 1 type of cable is required. N.B. Do Not use Vega BRI cables the pinout is completely different to PRI cables. The L2 LEDs on the Vega 400 and the channel LEDs on the Vega 100 indicate the connectivity status of the line. If the LED is off there is either no cable connection, or the cable is wrongly wired. If the LED is flashing, layer 1 (the physical layer) has connected OK, but signalling layer 2 has not connected properly. If the LED is solidly on then the signalling layer 3 has connected correctly. Bus master In order to keep synchronised the Vega should synchronise itself with a master clock typically the PSTN clock. Generally TE trunks receive the clock and NT trunks are clock masters. If a Vega trunk is not synchronised, then there will be SLIPs to check for SLIPs, use show ports. One or 2 slips often occur at start up this is acceptable; if the slip count keeps increasing, there is a problem that needs to be resolved. See Information Note IN03 ISDN clocks for details about how to configure clocking and Bus Master. Version 1.0 5 July 2006 Page 2 of 8

Layer 1 codec T1: By default the layer 1 codec is set to g711alaw64k (for E1), ensure that this is configured for g711ulaw64k. Channel allocation In an E1 or T1 trunk there are multiple (30, 24, 23) channels. When a call is placed a channel is selected to be used to pass the audio. If a call is being placed by the Vega at the same time that a call is being received by the Vega, ideally the calls should choose different channels to use for their audio. Details of configuration can be found in the step-by-step guide insert Vega between PSTN and PBX Fractional E1 / Fractional T1 In some installations, not all channels of a trunk are enabled for use. If this is the case the Vega should be configured with this information so that it does not try to use channels that are not active. Details of configuration can be found in the step-by-step guide insert Vega between PSTN and PBX T1 CAS: Info, RX Dial Format String and TX Dial Format String These three parameters allow the format of the incoming tones and outgoing tones that specify dialled number and optionally ANI (calling party number) to be configured. Info may be configured as dtmf or mf. This defines the tones to be used (frequencies etc). This must match the tone style being used by the device to which the Vega is being attached. RX Dial Format String and TX Dial Format String represent the sequence of tones to be used. Vega gateways have built in default settings, and these are indicated by the RX / TX Dial Format String being set to. Details of configuration of RX / TX Dial Format Sting can be found in the Vega Primer Only Signal mode = fgd (which is e & m signalling with the feature group D extension) supports ANI as well as dialled number the other schemes only support dialled number. If it is not clear what digits and delimiters are being sent to the Vega, once Info has been set correctly, the following debug can be used: debug enable _CAS i debug on See Annex 3 for an example output. Note: The RX Dial String format and the TX Dial String Format may not be the same Version 1.0 5 July 2006 Page 3 of 8

Long haul / short haul and equalization settings Vega gateways have the capability to adjust the line drive parameters (T1) and receive sensitivity (E1). These seldom need to be altered, but for full details on how and when to configure them, see the Vega Primer: For T1, look at the section titled: Guidelines for configuring t1_tx_equalization For E1, look for the section titled E1 line matching Note: the T1 parameter does not affect E1 operation and the E1 parameter does not affect T1 operation. License key On Vega 400 gateways ensure that the license key indicates that E1 is enabled for E1 connectivity and that T1 is enabled for T1 connectivity. Also check that the required codecs are enabled. Further configuration To configure your Vega for use, see the appropriate step-by-step initial configuration guide and / or the step-by-step guide insert Vega between PSTN and PBX Trouble-shooting RAI Remote Alarm Indication on PBX If the PBX shows a Remote Alarm Indication and layer 1 doesn t come up, try changing the CRC4 / PCM30 setting. No physical connection (LED off) - check that NT is connected to TE and TE is connected to NT - check whether a crossover is needed - check exact cabling pinouts Rx+ connects to TX+ Rx- connects to TX- Tx+ connects to Rx+ Tx- connects to Rx- - on E1 systems, check that CRC4 framing is selected if CRC4 is required and PCM30 if CRC4 is not required - check a LOG display on for errors like the Vega detecting both ends NT or both ends TE - if still problems take an ISDN trace (see Annex 2) especially look for SABMEs see also Incorrect socket wiring section (below) No layer 2 (LED flashing) - take an ISDN trace (see Annex 2) especially look for SABMEs Layer 2 up (LED on), call disconnects with error code 38 - check that the call is being routed to a trunk that is up Version 1.0 5 July 2006 Page 4 of 8

Layer 2 up (LED on), outgoing call to ISDN is rejected by the network - check that the caller ID being presented in the outgoing ISDN call is a valid caller ID for that trunk. Some network operators check the caller ID on outgoing calls and reject calls if an invalid caller ID is being presented (other network operators just over-stamp caller ID with the Trunk caller ID). Layer 2 up (LED on), some calls work, others don t - take an ISDN trace (see Annex 2) especially look for differences in the SETUP (and other) messages between working and non-working calls. - for instance Channel ID preferred / exclusive choice sometimes matters (see _advanced.isdn.chanid_excl) Type of Number, Numbering Plan, and screening information can be important generally these should be configured as supplied so that they are passed through from inbound call to outbound call. They can be overriden on a per trunk basis (advanced > setup_mapping > called party number / calling party number) or on a per call basis (planner.post_profile) Bearer capability generally this should be passed through but it can be overriden on a per trunk basis (advanced > setup_mapping > bearer capability). Incorrect socket wiring A socket can be diagnosed as being incorrectly wired / requiring a different crossover cable between the Vega and the socket if the following symptoms are observed: Device to connect to is NT: - with the cable plugged into a TE port on the Vega, Layer 1 does not come up (LED remains off) (Physically Tx is connected to Tx and Rx to Rx) - with the cable plugged into an NT port (instead of TE), Layer 1 comes up (LED flashes) (Physically Tx is correctly connected to Rx and Rx to Tx, but both ends are NT) Vega may display error log DSL port x: SABM/SABME/DISC Frame error; check the NT/TE setting ACTION: swap Tx and Rx in the cable or on the wall socket and connect to the TE port of the Vega Device to connect to is TE: - with the cable plugged into an NT port on the Vega, Layer 1 does not come up (LED remains off) (Physically Tx is connected to Tx and Rx to Rx) - with the cable is plugged into a TE port (instead of NT), Layer 1 comes up (LED flashes) (Physically Tx is correctly connected to Rx and Rx to Tx, but both ends are TE) Vega may display error log DSL port x: SABM/SABME/DISC Frame error; check the NT/TE setting ACTION: swap Tx and Rx in the cable or on the wall socket and connect to the NT port of the Vega Version 1.0 5 July 2006 Page 5 of 8

Annex 1 Physical connectivity of a Vega 400 PSTN (NT) TE 1 Rx+ 2 Rx- 4 Tx+ 5 Tx- NT 1 Tx+ 2 Tx- 4 Rx+ 5 Rx- 1 Tx+ 2 Tx- 4 Rx+ 5 Rx- Wall connector 1 Rx+ 2 Rx- 4 Tx+ 5 Tx- PBX (TE) Cable pinouts Cables with RJ48 plugs are used to connect to the Vega 400's ISDN ports. The pinout of each Vega 400 interface automatically changes from NT to TE depending on the configuration setting in the Vega. A (RED) straight through cable is used to connect an NT Vega DSL to a TE far end device, and the same (RED) straight through cable is used to connect a TE Vega DSL to an NT far end device. Vega 400 PRI Far end device Far end device NT (physical) TE TE 1 (Tx+) 1 (Rx+) 4 (Rx+) 2 (Tx-) 2 (Rx-) 5 (Rx-) 4 (Rx+) 4 (Tx+) 3 (Tx+) 5 (Rx-) 5 (Tx-) 6 (Tx-) VegaStream provided cables (ISO 10173) ISO 8877 Vega 400 PRI Far end device Far end device TE (physical) NT NT 1 (Rx+) 1 (Tx+) 4 (Tx+) 2 (Rx-) 2 (Tx-) 5 (Tx-) 4 (Tx+) 4 (Rx+) 3 (Rx+) 5 (Tx-) 5 (Rx-) 6 (Rx-) VegaStream provided cables (ISO 10173) ISO 8877 For Loopback between a Vega NT port and a Vega TE port, use the RED cable Version 1.0 5 July 2006 Page 6 of 8

Annex 2 ISDN trace Follow the guidelines in the Information Note IN 04 - Low level ISDN trace to take the trace. If there are link start up problems, look for SABMEs Both NT and TE devices should send SABMEs, though typically NT devices will send the SABME earlier than the TE device. Within the SABME there is a command_response bit. For a SABME sent NT to TE, the command_response bit =1 For a SABME sent TE to NT, the command_response bit =0 A SABME should be responded to with a UNNUMBERED ACK. Once the link is up, layer 2 RECEIVER READY messages should be seen. These can be initiated by both NT and TE devices. They should be responded to immediately by a RECEIVER READY message from the other device. For a RECEIVER READY command sent NT to TE, the command_response = 1 For a RECEIVER READY command sent TE to NT, the command_response = 0 For a RECEIVER READY response sent NT to TE, the command_response = 0 For a RECEIVER READY response sent TE to NT, the command_response = 1 Version 1.0 5 July 2006 Page 7 of 8

Annex 3 CAS trace Example output showing caller ID 0104, dialled number 1234 and *delimiting the numbers. This requires an RX Dial Format String value *o*n* ; turn off any old debug admin >debug disable all 0xff admin >debug disable _all 0xff ; re-enable errors and fatals admin >debug enable all ef admin >debug enable _all ef ; enable CAS debug admin >debug enable _CAS i admin >debug on debug to this console = enabled _CAS :Info : 4152114: 1258262:TN :DSL 1, CAS signal change :(vspli.c;1772) _CAS :Info : 4152434: 00320:ISDN :CAS_ProcessToneEvent(): DSL(0) Ch(01) Ready BACKWARD_TONE :(api_cas.c;394) _CAS :Info : 4152434: 00000:ISDN :CAS_ProcessEvent(): SEIZE :(api_cas.c;137) _CAS :Info : 4152434: 00000:ISDN :CAS_ProcessEvent(): SETUP :(api_cas.c;143) _CAS :Info : 4152439: 00005:ISDN :CAS_SendCallProceeding(00000001) :(api_cas.c;666) _CAS :Info : 4152934: 00495:ISDN :Received DTMF '*' (04) :(is_cassm.c;287) _CAS :Info : 4153084: 00150:ISDN :Received DTMF '0' (04) :(is_cassm.c;287) _CAS :Info : 4153084: 00000:ISDN :CAS_IncomingTone :cb 80f45668 ANI 0 :(api_cas.c;1170) _CAS :Info : 4153234: 00150:ISDN :Received DTMF '1' (04) :(is_cassm.c;287) _CAS :Info : 4153234: 00000:ISDN :CAS_IncomingTone :cb 80f45668 ANI 01 :(api_cas.c;1170) _CAS :Info : 4153384: 00150:ISDN :Received DTMF '0' (04) :(is_cassm.c;287) _CAS :Info : 4153384: 00000:ISDN :CAS_IncomingTone :cb 80f45668 ANI 010 :(api_cas.c;1170) _CAS :Info : 4153534: 00150:ISDN :Received DTMF '4' (04) :(is_cassm.c;287) _CAS :Info : 4153534: 00000:ISDN :CAS_IncomingTone :cb 80f45668 ANI 0104 :(api_cas.c;1170) _CAS :Info : 4153684: 00150:ISDN :Received DTMF '*' (04) :(is_cassm.c;287) _CAS :Info : 4153834: 00150:ISDN :Received DTMF '1' (04) :(is_cassm.c;287) _CAS :Info : 4153834: 00000:ISDN :CAS_IncomingTone :cb 80f45668 DNIS 1 :(api_cas.c;1185) _CAS :Info : 4153984: 00150:ISDN :Received DTMF '2' (04) :(is_cassm.c;287) _CAS :Info : 4153984: 00000:ISDN :CAS_IncomingTone :cb 80f45668 DNIS 12 :(api_cas.c;1185) _CAS :Info : 4154134: 00150:ISDN :Received DTMF '3' (04) :(is_cassm.c;287) _CAS :Info : 4154134: 00000:ISDN :CAS_IncomingTone :cb 80f45668 DNIS 123 :(api_cas.c;1185) _CAS :Info : 4154284: 00150:ISDN :Received DTMF '4' (04) :(is_cassm.c;287) _CAS :Info : 4154284: 00000:ISDN :CAS_IncomingTone :cb 80f45668 DNIS 1234 :(api_cas.c;1185) _CAS :Info : 4154434: 00150:ISDN :Received DTMF '*' (04) :(is_cassm.c;287) _CAS :Info : 4154437: 00003:ISDN :CAS_ToneAddrDone(00000001) :(api_cas.c;699) Contact Details Email: support@vegastream.com Web: www.vegastream.com www.vegaassist.com EMEA Office VegaStream Limited The Western Centre Western Road Bracknell Berks RG12 1RW UK +44 (0) 1344 784900 USA Office VegaStream Inc. 6200 Stoneridge Mall Road 3rd Floor Pleasanton California 94588 USA +1 925 399 6428 Version 1.0 5 July 2006 Page 8 of 8