*ATTENTION* ACAC12. Double Windpipe Portable Air Conditioner

Similar documents
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

PORTABLE AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner

Instruction manual for Firstline FCS12000CH

REMOTE CONTROL MANUAL

FTXS. Wall Mount Heat Pump or Cooling Only

USER S MANUAL HSC-24A

Use and Care Manual. Model CPA12KH AIR CONDITIONER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

york air-conditioning products Residential & VRF News 2015

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Installation, operation and maintenance manual TX 35A

Air Conditioning System

Pioneer in sustainability

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Operating Instructions Air Conditioner

HEATER, AIR CONDITIONING AND VENTILATION

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

ECO-AIR AIR CONDITIONING

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

How to choose a heat pump and use it wisely

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Glossary of Heating, Ventilation and Air Conditioning Terms

LG Wireless Remote Controller

DUCTED AIR CONDITIONING SOLUTIONS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Lesson 36 Selection Of Air Conditioning Systems

AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

PORTABLE AIR CONDITIONER

FOXAIR 60/50 ALL MODELS

FHQ. Ceiling Suspended Heat Pump or Cooling Only

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

Operating Instructions Air Conditioner

Dehumidifier D 850E. - Instruction manual version 02

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Single Zone LCD Thermostat Operating Instructions

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Failure code manual. content

air conditioners how to choose a cooling system

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Unico Inverter. Unique and efficient.

Operating Instructions Split System Air Conditioner

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Portable Air Conditioner

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

14. Troubleshooting Guide

FBQ. DC Duct Heat Pump or Cooling Only

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Condensing unit type EPSILON-ECHOS LE Technical information manual

3-2. Using the air conditioning system and defogger Automatic air conditioning system

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

FULL DC INVERTER SYSTEMS

Room Air Conditioners

FTQ. Daikin Inverter Ducted Heat Pump

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Split Type Room Air Conditioner. KSWM units

Cooking at the Speed of light!

Samsung Room Air Conditioning

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

APC APPLICATION NOTE #112

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

How Ground/Water Source Heat Pumps Work

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

ChapterⅠ Introduction to Products

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

PORTABLE AIR CONDITIONER

CRAC Precision climate control units for data centres

USER S INFORMATION MANUAL

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Transcription:

ACAC12 Double Windpipe Portable Air Conditioner *ATTENTION* THIS AIR CONDITIONER UNIT IS RECOMMENDED FOR GARDENING APPLICATIONS NOT EXCEEDING A 10 X 10 X 8 ROOM AND (2) AIR COOLED 1000 WATT HID LIGHTING SYSTEMS THE COMPRESSOR INSIDE THIS UNIT IS NOT SEALED, SO A SMALL AMOUNT OF AIR FROM THE ROOM IN WHICH IT SITS MAY BE EXCHANGED THROUGH THE INTERIOR AIR INLET FOUND ON THE BACK OF THE UNIT.

INTRODUCTION: This mobile air conditioner is a new generation air conditioner which is ideal for using in a bedroom, lobby, office, attic, sports hall, or other entertainment area. Its flexible characteristic enables easy adjustments to desirable room temperature and humidity levels. The built in filter can also remove floating dust and purify air to create a healthier environment. It is designed under novelty, practicality and convenience principles to satisfy the needs for convenient, efficient and mobile small sized air conditioning. It features easy using, minimal installation, and convenient maintenance. The double control system (remote control/manual control) and LCD display ease operation. The unit is highly competitive to other air conditioning capable products. With tidy structure, multiple functions and reasonable ventilation design, the unit minimizes noise and power consumption. Thank you for choosing our mobile air conditioner. This instruction manual is for reference only and does not constitute a contract. We reserve the right to make technical changes without prior notices. WORKING PRINCIPLE: Cooling: Refrigerant with low temperature and low pressure is compressed by the internal compressor to high temperature and high pressure gas. The gas then cools in the condenser to become low temperature, high pressure liquid. The liquid flows through the capillary tube to lower its pressure and becomes low temperature, low pressure liquid. The low temperature lowpressure liquid is evaporated in the evaporator. After absorbing the heat of air in the surface of the evaporator, the refrigerant becomes gas and flows back to the compressor. The refrigerant gas repeats the compression process, thus the room temperature is lowered by circulating this operation. The compressor activates when the unit s room temperature sensor records a temperature higher than the set room temperature on the LCD window. When the room temperature sensor records a lower temperature than the set room temperature on the LCD window the compressor stops and the fan operates at the original set speed. Dehumidifying: If the unit is ONLY used a dehumidifier, please always remember to remove the air exhaust duct from the main unit; when the unit is used as a air conditioner, mount the air exhaust duct to the air outlet (terminal) of the main unit. In dehumidify mode the compressor is on and the internal fan motor operates in a LOW speed.

TECHNICAL SPECIFICATIONS: Model: ACAC12 Cooling Capacity (BTU/H): 12,000 Dehumidifying Capacity (L/Day): 40 Power (Watts): Cooling 1100 Dehumidifying 950 Circulation Volume (m/h): 370 Power source (Single Phase): AC110 120V/60Hz Noise Pressure Level db(a): <52 Net Weight (KG): 47 Dimensions: 34.9 x 17.8 x 19.7 Refrigerant: R22 (550g) Applying Space (m) 15 20 Note: 1. The above cooling capacity is measured at ambient temperature Db 86 degrees Fahrenheit, WB 77.9 degrees Fahrenheit (Indoor and outdoor, the same). 2. Noise level is measured at the distance of 1.0 meter away from the front of the machine, in cooling mode when the compressor is active. 3. Fan power consumption is measured when the fan runs at the highest speed. 4. Specification listed above is for reference only. Please see actual data printed on the label. OPERATION: ON/OFF Button: Press the ON/OFF button once to turn the power on, this will run the unit at AUTO mode and the LCD window will display AUTO.

Press the ON/OFF button while the unit is running and this stops the operation, therefore cancelling the timer, but retaining mode, set temperature, fan speed and air flow mode. Press the ON/OFF button while the unit is ready, this restarts the unit operation with the settings that were last set, aside from the previous timer settings. MODE Button: Pressing the MODE button will change the sequence of operation between AUTO, COOL, FAN, DEHUMIDIFY, and HEATING. The mode will display in the LCD window correspondingly. SPEED Button: Pressing the SPEED button will adjust the fan speed between LOW, MEDIUM, HIGH, and display in the LCD window correspondingly. TEMP Button: Pressing the various UP & DOWN TEMP buttons will adjust the temperature set point higher or lower. The selected temperature will display in the LCD window between the ranges of 15 31 degrees Celsius. When the unit is set at AUTO, the default cooling temperature is 23 degrees Celsius. TIMER Button: AUTO OFF TIME SETTING When the unit is running, pressing the TIMER button will set the desired OFF time. The range is from a ½ hour to 12 hours, which will display in the LCD window. AUTO ON TIME SETTING When the unit is ready, but not operating, pressing the TIMER button will set the desired ON time. The range is from a ½ hour to 12 hours, which will display in the LCD window. Wind Direction Adjustment: Horizontal: Pressing the wind adjustment button on the control panel or remote control will promote left and right oscillation of the air vent automatically. Vertical: Adjust the air vent manually to dictate up and down direction of air flow.

An internal microprocessor controls the compressor and fan ON/OFF operation according to the room temperature. To protect the compressor from damage, when the unit restarts it will take approximately 3 minutes before it starts to run again. Fan Mode: The compressor and outer fan motor stop, however the inner fan motor will run at the set speed. At this point the TEMP button is void as temperature is not a dictation of operation. AIR EXHAUST AND INTAKE DUCTS: The unit has casters that allow for mobility of the unit. You may use the following methods to engulf outer air to feed the unit and exhaust heated air from the unit. 1. Engulf outer air and exhaust heat through a nearby window. Opening a window enough to fit the plastic intake and exhaust ducts outside the area will provide proper air exchange. 2. The same practice can be accomplished through a nearby door. Open the door slightly so that the ducts fit outside the opening. 3. For larger areas, the ducts may be placed on the ground directly 4. To properly store the unit, remove the intake and exhaust ducts and store them carefully. Special Notes: The ducts may be extended from 20 to 79, however the unit will operate more efficiently when the air exhaust duct is maintained at a shorter distance. This will allow heat to be transferred out of the system at a faster rate with less radiant heat to dissipate from the duct itself. Make sure the exhaust duct is not distorted or it may obstruct the effectiveness of the heat exhaust process, thus causing heat to flow back through the unit combating the cooling efficiency. As a safety the unit will automatically stop running if this occurs. To ensure that the air intake duct is operating correctly, do not place any objects around the opening of the duct. Failure to do so will prevent hot air from properly exhausting from the unit and cooling the condenser. The compressor will automatically stop if this occurs. Make sure not to extend the ducts or use them with other specifications. This may decrease the working efficiency of the unit.