Evaluation copy. Investigating Indicators. Computer OBJECTIVES CHOOSING A METHOD

Similar documents
Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

Neutralization Reactions. Evaluation copy

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

18 Conductometric Titration

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Household Acids and Bases

The Determination of an Equilibrium Constant

Endothermic and Exothermic Reactions. Evaluation copy. Mg(s) + 2 HCl(aq) H 2 (g) + MgCl 2 (aq)

Evaluation copy. Energy Content of Foods. computer OBJECTIVES MATERIALS

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Experiment 17: Potentiometric Titration

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

Pressure -Temperature Relationship in Gases. Evaluation copy. Figure ml Erlenmeyer flask. Vernier computer interface

Acid Base Titrations

Drop Counter Sensor Product Number: ENDRP-AD100

Experiment 6 Titration II Acid Dissociation Constant

EXPERIMENT INTRODUCTION TO INDICATORS AND ACID-BASE TITRATIONS

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Acid-Base Titrations Using ph Measurements

1. To perform a potentiometric titration of a sample of Liquid Drano with hydrochloric acid.

ph: Measurement and Uses

Phosphates (ortho- and total)

Acid Dissociation Constants and the Titration of a Weak Acid

Evaluation copy. Case File 9. A Killer Cup of Coffee? GlobalTech manager dies

Acid Base Titration: ph Titration Curve

Neutralizing an Acid and a Base

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

EXPERIMENT 10: TITRATION AND STANDARDIZATION

Osmosis. Evaluation copy

Evaluation copy. Enzyme Action: Testing Catalase Activity (Method 1 O 2 Gas Sensor) Computer 2

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Maximum value. resistance. 1. Connect the Current Probe to Channel 1 and the Differential Voltage Probe to Channel 2 of the interface.

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

Properties of Acids and Bases

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

Lab #10 How much Acetic Acid (%) is in Vinegar?

Juice Titration. Background. Acid/Base Titration

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

COMMON LABORATORY APPARATUS

CHM1 Review for Exam 12

Experiment 4 (Future - Lab needs an unknown)

Acid-Base Titrations. Setup for a Typical Titration. Titration 1

EXPERIMENT 2 THE HYDROLYSIS OF t-butyl CHLORIDE. PURPOSE: To verify a proposed mechanism for the hydrolysis of t-butyl Chloride.

GA/7 Potentiometric Titration

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

Solar Homes and Heat Sinks. Evaluation copy. empty bottle with screw-on cap

Analyzing the Acid in Vinegar

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

The Determination of Acid Content in Vinegar

TITRATION OF AN ACID; USING A ph METER. The ph meter is an instrument that measures the ph of a solution and affords a

Electrical Conductivity of Aqueous Solutions

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

Extraction: Separation of Acidic Substances

Water Hardness. Evaluation copy

Household Acids and Bases

POTENTIOMETRIC TITRATION OF A WEAK ACID

Experiment 7: Titration of an Antacid

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

TITRATION OF VITAMIN C

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

ph and Acidity in Wine and Fruit Juice

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

The Determination of an Equilibrium Constant

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

Experiment 8 - Double Displacement Reactions

Determining the Identity of an Unknown Weak Acid

Color, True and Apparent

EXPERIMENT 12 A SOLUBILITY PRODUCT CONSTANT

Introduction. Depolymerization of Poly(lactic acid) Cups to Lactic Acid. Experiment

Calcium Analysis by EDTA Titration

Determination of Citric Acid in Powdered Drink Mixes

Lift the Load! Make a lever. Measure the amount of force needed to lift up a book when applying a force at different positions on the lever.

Color, True and Apparent

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory.

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

CHM 130LL: ph, Buffers, and Indicators

Recovery of Elemental Copper from Copper (II) Nitrate

Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.

Experiment 6 Coffee-cup Calorimetry

Lab #13: Qualitative Analysis of Cations and Anions

ph and Acidity in Tomato Sauce

IODINE CLOCK. A Study of Reaction Rates.

1. Qualitative Analysis of Chromium, Iron, and Copper

AP CHEMISTRY 2010 SCORING GUIDELINES (Form B)

Properties of Acids and Bases

Designing An Experiment Using Baking Soda and Vinegar

ANALYSIS OF VITAMIN C

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

EXPERIMENT 4 Acid Strength

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Partner: Jack 17 November Determination of the Molar Mass of Volatile Liquids

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Transcription:

Investigating Indicators Computer 11 An indicator solution does what its name suggests it indicates. In chemistry, a common use of an indicator is to signal the equivalence point of a reaction between an acid and a base. Generally, an indicator is itself a weak organic acid or a blend of weak organic acids. The indicator establishes equilibrium in aqueous solution, which is shifted according to LeChatelier s principle as the solution changes in ph. The indicator is one color in the presence of a range of concentrations of H + or OH ions, and another color when the acidity changes. Knowing when an indicator will change color helps you determine the precise equivalence point of an acid-base reaction. This knowledge is also important as you select the proper indicator for a given reaction. OBJECTIVES In this experiment, you will Conduct strong acid-strong base titrations using solutions of hydrochloric acid and sodium hydroxide, and three different indicator solutions. Select the proper indicator to use with a titration involving a weak acid or a weak base, based on your observations and measurements. CHOOSING A METHOD Figure 1 Evaluation copy If you choose Method 1, you will conduct the titration in a conventional manner. You will deliver volumes of NaOH titrant from a buret. You will enter the buret readings manually to store and graph each ph-volume data pair. If you choose Method 2, you will use a Vernier Drop Counter to conduct the titration. NaOH titrant is delivered drop by drop from the reagent reservoir through the Drop Counter slot. After the drop reacts with the reagent in the beaker, the volume of the drop is calculated and a ph-volume data pair is stored. Advanced Chemistry with Vernier 11-1

Computer 11 MATERIALS Materials for both Method 1 (buret) and Method 2 (Drop Counter) Vernier computer interface magnetic stirrer computer stirring bar or Microstirrer Vernier ph Sensor wash bottle 0.10 M sodium hydroxide, NaOH, solution ring stand 0.10 M hydrochloric acid, HCl, solution utility clamp 0.10 M acetic acid, HC 2 H 3 O 2, solution phenolphthalein indicator solution 0.10 M ammonia, NH 3, solution bromthymol blue indicator solution 250 ml beaker methyl orange indicator solutions 50 ml graduated cylinder distilled water pipet bulb or pump Materials required only for Method 1 (buret) 50 ml buret buret clamp 10 ml pipet Materials required only for Method 2 (Drop Counter) Vernier Drop Counter 100 ml beaker reagent reservoir 10 ml graduated cylinder 5 ml pipet a second 250 ml beaker METHOD 1: Measuring Volume Using a Buret 1. Obtain and wear goggles. Part I Strong Acid Strong Base Titrations 2. Use a graduated cylinder to measure out 20 ml of 0.10 M HCl solution into a 250 ml beaker. Add exactly two drops of methyl orange indicator solution to the beaker of HCl solution. CAUTION: Handle the hydrochloric acid with care. It can cause painful burns if it comes in contact with the skin. 3. Place the beaker on a magnetic stirrer and add a stirring bar. If no magnetic stirrer is available, stir the reaction mixture with a stirring rod during the titration. 4. Connect a ph Sensor to Channel 1 of the Vernier computer interface. 5. Use a utility clamp to suspend the ph Sensor on a ring stand as shown in Figure 1. Position the ph Sensor in the HCl solution and adjust its position so that it is not struck by the stirring bar. 6. Rinse and fill the buret with 0.10 M NaOH solution. CAUTION: Sodium hydroxide solution is caustic. Avoid spilling it on your skin or clothing. 7. Start the Logger Pro program on your computer. Open the file 11a Indicators from the Advanced Chemistry with Vernier folder. 11-2 Advanced Chemistry with Vernier

Investigating Indicators 8. You are now ready to begin the titration. Conduct the titration carefully, as described below. Watch carefully to see if the indicator changes color before, at the same time, or after the rapid change in ph at the equivalence point. If this is a suitable indicator for the reaction, it should change color at about the same time as the jump in ph occurs. In your data table, record the volume when the indicator changes color. a. Before you have added any NaOH solution, click. Once the displayed ph reading has stabilized, click. In the edit box, type 0 (for 0 ml added). Press the ENTER key to store the first data pair for this experiment. b. Add 1 ml of the NaOH titrant. When the ph stabilizes, click. In the edit box, type the current buret reading. Press ENTER. You have now saved the second data pair for the experiment. c. Continue adding NaOH solution 1 ml at a time, entering the buret reading after each increment, until the ph of the mixture is about 5. d. Add NaOH in 0.5 ml increments until the ph is about 10. e. Continue adding NaOH solution in 1 ml increments until the ph value remains constant. 9. When you have finished collecting data, click. 10. Dispose of the reaction mixture as directed. Rinse the ph Sensor with distilled water in preparation for the next titration. 11. Label the point on your graph where the indicator solution changes color and describe the color change. To do this, choose Text Annotation from the Insert menu. Print a copy of the titration curve. 12. Repeat the necessary steps to conduct a second and third trial, using the bromthymol blue and phenolphthalein indicator solutions. Repeat Step 11 to analyze the titration curve for your second and third trials. Part II Select an Appropriate Indicator for the Titration of a Weak Acid or a Weak Base 13. Obtain a weak acid or weak base solution from your instructor. If you are testing a weak acid, use the 0.10 M NaOH solution as the titrant. If you are testing a weak base, rinse and fill your buret with the weak base solution, and titrate 20 ml of 0.10 M HCl solution. Use the results of your previous tests to select the appropriate indicator solution for this trial. Conduct the trial using the same procedure as before. Label the point on your graph where the indicator solution changes color and describe the color change. Print a copy of the titration curve. METHOD 2: Measuring Volume Using a Drop Counter 1. Obtain and wear goggles. Part I Strong Acid Strong Base Titrations 2. Add 40 ml of distilled water to a 100 ml beaker. (You can add less, about 20 ml, if you will be using a stirring bar instead of the Microstirrer.) Use a pipet bulb (or pipet pump) to pipet 5.00 ml of the HCl solution into the 100 ml beaker with distilled water. Add exactly one drop of methyl orange indicator solution to the beaker of HCl solution. CAUTION: Handle the hydrochloric acid with care. It can cause painful burns if it comes in contact with the skin. Advanced Chemistry with Vernier 11-3

Computer 11 Figure 2 3. Lower the Drop Counter plate onto a ring stand and clamp it into position (see Figure 2). 4. Connect the Drop Counter to DIG/SONIC 1 of the Vernier computer interface. Connect the ph Sensor to CH 1 of the interface. 5. Start the Logger Pro program on your computer. Open the file 11b Indicators (Drop) from the Advanced Chemistry with Vernier folder. 6. Obtain the plastic 60 ml reagent reservoir. Close both valves by turning the handles to a horizontal position. Follow the steps below to set up the reagent reservoir for the titration. a. Rinse the reagent reservoir with a few ml of the 0.10 M NaOH solution and pour the NaOH into an empty 250 ml beaker. b. Use a utility clamp to attach the reservoir to the ring stand. c. Fill the reagent reservoir with slightly more than 60 ml of the 0.10 M NaOH solution. d. Place the 250 ml beaker, which contains the rinse NaOH, beneath the tip of the reservoir. e. Drain a small amount of the NaOH solution into the 250 ml beaker so that it fills the reservoir s tip. To do this, turn both valve handles to the vertical position for a moment, then turn them both back to horizontal. f. Discard the drained NaOH solution in the 250 ml beaker as directed. 7. Calibrate the drops that will be delivered from the reagent reservoir. Note: If you are using the stored calibration (20 drops per ml), then skip this step. a. Choose Calibrate DIG 1: Drop Counter (ml) from the Experiment menu. b. Proceed by one of these two methods: If you have previously calibrated the drop size of your reagent reservoir and want to continue with the same drop size, select the Manual button, enter the number of Drops/mL, and click. Then proceed directly to Step 8. If you want to perform a new calibration, select the Automatic button, and continue with Part c of this step below. 11-4 Advanced Chemistry with Vernier

Investigating Indicators c. Place a 10 ml graduated cylinder directly below the slot on the Drop Counter, lining it up with the tip of the reagent reservoir. d. Open the bottom valve on the reagent reservoir (vertical). Keep the top valve closed (horizontal). e. Click the Start button. f. Slowly open the top valve of the reagent reservoir so that drops are released at a slow rate (~1 drop every two seconds). You should see the drops being counted in Logger Pro. g. When the volume of the NaOH solution in the graduated cylinder is between 9 and 10 ml, close the bottom valve of the reagent reservoir. h. Enter the precise volume of NaOH in the edit box. Record the number of Drops / ml displayed on the screen for possible future use. i. Click. Discard the NaOH solution in the graduated cylinder as directed, and set the graduated cylinder aside. 8. Assemble the apparatus as shown in Figure 2. a. Place the magnetic stirrer on the base of the ring stand. b. Insert the ph Sensor through the large hole in the Drop Counter. c. Attach the Microstirrer to the bottom of the ph Sensor. Rotate the paddle wheel of the Microstirrer, and make sure that it does not touch the bulb of the ph Sensor. d. Adjust the positions of the Drop Counter and reagent reservoir so they are both lined up with the center of the magnetic stirrer. e. Lift up the ph Sensor, and slide the 100 ml beaker containing the HCl solution (from Step 2) onto the magnetic stirrer. Lower the ph Sensor into the beaker. f. Adjust the position of the Drop Counter so that the Microstirrer on the ph Sensor is just touching the bottom of the beaker. g. Adjust the reagent reservoir so its tip is just above the Drop Counter slot. 9. Turn on the magnetic stirrer so that the Microstirrer is stirring at a fast rate. 10. You are now ready to begin collecting data. Click. No data will be collected until the first drop goes through the Drop Counter slot. Fully open the bottom valve. The top valve should still be adjusted so drops are released at a rate of about 1 drop every 2 seconds. When the first drop passes through the Drop Counter slot, check the data table to see that the first data pair was recorded. 11. Watch carefully to see if the indicator changes color before, at the same time, or after the rapid change in ph at the equivalence point. Note: Volume is displayed in the live table. If this is a suitable indicator for the reaction, it should change color at about the same time as the jump in ph occurs. Note the volume when the indicator changes color. 12. After the jump in ph occurs, continue to deliver about 3 more milliliters of NaOH solution, then click. Turn the bottom valve of the reagent reservoir to a closed (horizontal) position. Dispose of the beaker contents as directed. 13. Label the point on your graph where the indicator solution changes color and describe the color change. To do this, choose Text Annotation from the Insert menu. Print a copy of the titration curve. 14. Repeat the necessary steps to conduct a second and third trial, using the bromthymol blue and phenolphthalein indicator solutions. Repeat Step 13 to analyze the titration curve for your second and third trials. Advanced Chemistry with Vernier 11-5

Computer 11 Part II Select an Appropriate Indicator for the Titration of a Weak Acid or a Weak Base 15. Obtain a weak acid or weak base solution from your instructor. If you are testing a weak acid, use the 0.10 M NaOH solution as the titrant. If you are testing a weak base, rinse and fill your reagent reservoir with the weak base solution, and titrate 5 ml of 0.10 M HCl solution. Use the results of your previous tests to select the appropriate indicator solution for this trial. Conduct the trial using the same procedure as before. Label the point on your graph where the indicator solution changes color and describe the color change. Print a copy of the titration curve. DATA ANALYSIS 1. Describe how the three indicator solutions worked in the titrations. Which indicator solution is the best for a strong acid-strong base titration? Specify the color changes and the ph readings where the color changes occurred. 2. For which type of acid-base titrations would the other two indicator solutions be best suited? Explain. 3. Use the graphs to compare how accurately the indicator solutions indicated the equivalence point of the titrations that you conducted. In your judgment, can an indicator alone accurately determine the equivalence point of an acid-base reaction? Explain. 11-6 Advanced Chemistry with Vernier

Vernier Lab Safety Instructions Disclaimer THIS IS AN EVALUATION COPY OF THE VERNIER STUDENT LAB. This copy does not include: Safety information Essential instructor background information Directions for preparing solutions Important tips for successfully doing these labs The complete Advanced Chemistry with Vernier lab manual includes 35 labs and essential teacher information. The full lab book is available for purchase at: http://www.vernier.com/cmat/chema.html Vernier Software & Technology 13979 S.W. Millikan Way Beaverton, OR 97005-2886 Toll Free (888) 837-6437 (503) 277-2299 FAX (503) 277-2440 info@vernier.com www.vernier.com