CITY OF UPLAND GARDEN WALL STANDARD Building Divison, City of Upland, 460 North Euclid Avenue, Upland, CA 91/

Similar documents
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Section 2100-Trenching and Tunneling

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Chapter 3 Pre-Installation, Foundations and Piers

COMMONLY USED RESIDENTIAL BUILDING CODES

SECTION STORM DRAINAGE SYSTEM

Storm Drain Inlet Protection - IP

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The minimum reinforcement for the stem wall is the placement of:

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Superform Products Ltd.

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

SECTION STORM DRAINAGE TABLE OF CONTENTS

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Safe & Sound Bridge Terminology

MANUFACTURED HOUSING USED AS DWELLINGS

Residential Foundations and Basements

Residential Deck Safety, Construction, and Repair

Lighthouse Engineering, L.L.C.

SECTION STORM DRAIN SYSTEM

Connex. Mortarless Masonry Block System

Technical Notes 3B - Brick Masonry Section Properties May 1993

Proposed Minimum Subterranean Termite Treatment Standards

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

LAYING BLOCK AND BRICK

SECTION EARTH MOVING

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

FY08 SEWER POINT REPAIRS BID TABULATION

POST AND FRAME STRUCTURES (Pole Barns)

Ver. 2. Guide to. Inspecting Residential Brick Veneer

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

Beacon Hill Sewer District Standard Specifications

Section 402. STORM SEWERS

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

How To Retaining Wall Guide

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Table 4.9 Storm Drain Inlet Protetion Applicable for

SANITARY SEWER SPECIFICATIONS

How to secure your property after a disaster

EAST LYME HIGH SCHOOL

Louisiana Administrative Code Title 51 Part XIII. Sewage Disposal

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Mobile Home Pre-Inspection Checklist

PVC PIPE PERFORMANCE FACTORS

Guide for SOLID CONCRETE BLOCK SEALS

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

State of Connecticut Department of Public Health RADON PROGRAM

1. ASTM C Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

Ohio Board of Building Standards Building on the Code Education Series. Residential Code of Ohio Chapter 4 March 1, Presentation Handout

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

IRC 2009 CODE REQUIREMENTS FOR CIP CONCRETE FOUNDATIONS SUPPORTING LIGHT FRAME CONSTRUCTION IN SEISMIC DESIGN CATEGORY B (WITH QUESTIONS AND ANSWERS)

BMP-7. A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet.

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Gas Meter Clearances and Service Installation Requirements

TORO STEEL BUILDINGS. BOLTS: o " diam. x " diam. x " diam. C.J. - Control Joints to minimize cracking.(0.

Section SEWER PIPE INSTALLATION AND TESTING

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Wastewater Capital Projects Management Standard Construction Specification

Additions and Alterations

Gas Meter Clearances and Service Installation Requirements

Underground Service Requirements and Instructions

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

Fiberstars Mini Lighted Laminar Flow Fountains

Top 10+ Mistakes of DWV plumbing design

Tremie Concrete CM 420 CM 420 CM 420 CM 420. Temporary Structures. Tremie Concrete

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Mark Cramer Inspection Services, Inc.

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Chapter. Restoration of Damaged Structures

LS 2540 SEWER LATERALS AND INSPECTION TEES

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

CHIMNEYS AND FIREPLACES

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012

Lowering Basement Floors (Underpinning, Benching)

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

Elevating Your House. Introduction CHAPTER 5

Specifications for Residential Property Owners Connection to New Public Sewer

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

MUNICODE SERVICES LTD.

Permeable Pavement Construction Guide

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Transcription:

40G1 CITY UPLAND GARDN WALL STANDARD Building Divison, City of Upland, 460 North uclid Avenue, Upland, CA 91/86 909 931-41 10 Name: Permit #: SPCIFICATIONS: All footings adjacent to slopes to be at least 5 to day light as shown at left. This wall may not be constructed in a water course or otherwise obstruct natural drainage or run-off and it may not be used to retain earth or support other structures. BOTrOM *:::*:* 5 MIN Concrete blocks are Grade N per ASTMC9O-03. Mortar is Type M or S per section 2103.8 & grout is per section 2103.10.7, Mm 10 thick. Reinforcing steel is minimum Grade 40 deformed bars per ASTM Standards. Lap steel at least 24 inches. 6 feet, maximum Grout all cells that contain reinforcement bars. Install #4 horizontal bar bond beam in blocks along the top of the wall. Install grout stop mesh only in the cells that do not have vertical steel. Refer to mesh details on last page. 6 or 8 inch concrete blocks. #4 Vertical reinforcements bars @ 32" o.c to be centered in the wall. GARDN WALL 1. Footings & Pebar 2*Top Bond> {!J steel installed 3*Grout ji stee cells>before cap 4*FINAL TH OWNR / CONTRACTOR IS RSPONSIBL FOR TH ACCURACY WALL & LOCATIONS AT TH PROPRTY LINS. #4 vertical bars @ 32" on centers to be placed along bottom of footing, minimum 3" above soil, and extend upwards approximately 36" above turn angle, so as to obtain a minimum 24" lap with wall drop-in verticals. #4 horizontal bar at bottom of footing minimum 3" above soil. Alternate bends in footing steel. Bottom of footing tobe Mm J2"deep into undisturbed soil 3" clear 3" All steel to be :. :..... - 4 mm. 3" clear.- 3"dear3" - w W = 24" for up to 4 high wall. 36" when over 4 high. W = 19" for up to 4 high wall. 27" when over 4 high. Keep all footing steel 3" minimum from soil Use concrete dobies to maintain clearances. RVISON 002 03-30-1 1

140 RI 4 CITY UPLAND RTAINING WALL STANDARD Name: Permit #: SPCIFICATIONS: All footings adjacent to slopes to be at least 5 to day light as shown at left. These retaining walls shall support level soil backfill only, not designed to support other structures or walls. Keep top of wall away from structures, toe of slopes, and vehicle wheel loads a distance equal to the height of the wall. Minimum 8" wide concrete blocks are Grade N per ASTMC90-03. Mortar is Type M or S per section 2103.8 &groutis persection 2103.10.7. Mm 12" thick. Reinforcing steel is minimum Grade 40 deformed bars per ASTM Standards. Lap steel at least 24 inches. DO NOT BACKFILL WALLS FOR AT LAST SVN DAYS AFTR WALL IS GROUTD. NO TO WALL One of the # 4 horizontal bars in - bond beam block at the top of the wall. ir NO HL WALL 8 inch mm. concrete blocks Non-Load face of wall..4 - Grout all cells solid Place vertical bars per table below - 5-1/4 inches from non-load face of wall A POURD CONCRT WALL WITH TH SAM DIMNSIONS MAY B SUBSTITUTD FOR TH CONCRT BLOCKS #4 horizontal in bond beam block qually spaced - See Table for number of horizontal bars in the wall One cubic foot of 3/4 to 1-12" clean -I.. gravel behind the wall with weep holes or omit alternate first course head joints or a 4 PVC perforated pipe with holes down, sloped 1 % to an approved drain. J1 2- #4 longitudinal bars in footing. Add a #4 for footings 3-0" wide or wider. Height This is the Non-Load face wall. -. - I; -L RTAINING WALL 1- Faotinqs & Rebar 2-Top Bond> {AM steel installed 3-Grout i! steel cells>before cap 4-Verify Drainaqe is Adequate 5-FINAL- Level Backfill Only TI-J OVVNfl / CONrflAC1l IS F4SF ONSINL Ofl -rh F 0 O-I NC LOCA-rI ONS cr VH r I40PnTV LINS. a... 4. 2 * a, - *= =.=,. 4.,.-.... * : Keep footing 4teel 311 miniraium from dirt...-. *1 4.... l4ey may be Ioc4ed anyplace: along footing 2" O,ide key a. I 2" thick footing Key Depth per table Same as vertical steel o.c Footing width Per table below * #4 @ 32" 0-c- OK for the top 4-811, RVISON 002 03-30-1 1

140 GRI CITY UPLAND COMBO GARDN, RTAINING WALL STANDARD Name: Permit #: - SPCIFICATIONS All footings adjacent to slopes to be at least 5 to day light as shown at left. These walls shall not support other structures. Keep top of retaining portion of wall away from structures, toe of slopes, and vehicle wheel loads a distance equal to the height of the retaining portion of wall. BOTIOM IL,,. 5 MIN. Concrete blocks are Grade N per ASTMCOO-03. Mortar is Type M or S per section 2103.8 & grout is per section 2103.7. Mm 12 thick. Reinforcing steel is minimum Grade 40 deformed bars per ASTM Standards. Steel bar laps to be at least 24 inches. c I j Grout all cells that contain reinforcement bars. Install #4 horizontal bar bond beam in blocks along the top of the wall. Install grout stop mesh only in the cells that do not have vertical steel. Refer to mesh details on last page. -. 6 or 8 inch concrete blocks. #4 Vertical reinforcements bars bar @ 24" o.c to be centered in the wall, Must provide a minimum 24" lap of the vertical bars protruding up out of the top of the concrete footing. COMBO GARDN / RTAINING 1. Footinqs & Rebar 2*Retaining Steel Bond> no mesh 3-Retaininq qrout inspection 4.iop Bond> All steel installed 5.Grout all steel cells>before cap 6.FINAL TH OWNR, CONTRACTOR IS RSPONSINF FOR TH ACCURACY WAL & FOCATIONS AT TH PROPRTY LINS Non load Face of wall # 4 horizontal bar in bond beam block at the top of the retaining wall. Mm 8 inch Retaining concrete blocks with all cells grouted in the retaining portion of the wall wall with #4 @ 24" on centers placed 5-1/4 in from the Non load face of the wall. One cubic foot of 3/4 to 1-1/2 clean gravel behind the wall with weep holes or omit alternate first course head joints or a 4 PVC perforated pipe with holes down, sloped 1% to an approved drain. 12 thick footing *.* 4 4 a =4 = 4 12" thick footing 2 #4 IongudinaI ba in oting. minimum 3" above soil. 4" deep key - Locate key anyplace along footing. 36" wide footing 36" wide footing Keep all footing steel 3" minimum from soil Use concrete dobies to maintain clearances. RVISON 002 03-30-1 1

CITY UPLAND MASONRY COLUMN STANDARD I MASONRY COLUMNS For support of open fencing only. Wrought Ironi MAXIMUM 42" HIGH IN RQUIRD FRONT YARDI Column Width,12"Min,, - 16" Max 2-#4 Bars Full Height. 9 Brick or Concrete clock. Grout Solid 2- #4 Bars xtend Footing 1O -"Max Open Wrought Iron not solid. Design by others. e To Adjacent Column 1 " Mm. exterior 2" when exposed to earth. 3,, Clear Footing width to be 8" wider than column width. VRTICAL BAR RINFORCMNT RVISON 001 03-30-1 1

CITY UPLAND MSH DTAIL STANDARD 40 J Mesh to retain grout. Only in Cells where there is no vertical steel. Mm. cover HORIZONTAL BOND BAM STL BAR RINFORCMNT 1/2" Maximum GROUT SLUMP 1/2" MAXIMUM MORTAR PROJCTION INTO GROUT SPAC Grout must be plastic with a slump fluidity of 8 inches 203 mm to 11 inches 279 mm when tested in accordance with ASTM C 143 and be cohesive to avoid segregation of materials, particularly pea gravel. RVISON 001 03-30-1 1