PURUS 20. Operation / Maintenance Manual. SERIAL NUMBER (located on back of product): PATENTS: U.S ,

Similar documents
CG PTFE Diaphragm Liquid Transfer Pump

BOWIE PUMPS OPERATION - MAINTENANCE

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

Oil and Coolant Circulating Heating System. Model - OCSM

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

PRESSURE REDUCING CONTROL VALVE

Waste Oil Handling, Spill Containment & Lighting

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Hydraulic Trouble Shooting

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

TYPE E Main Valve Sizes 3 /8 through 12

Installation, Operation and Maintenance Manual for Pilot Operated Valves

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

Subject: 2005 Air Conditioning Service Guidelines

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Standard Hydraulic Piping Flushing Procedure

Vertical selfpriming Side-Channel Pumps Type WPV

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Chapter 7 Hydraulic System Troubleshooting

This instruction is valid for all ACD pump models shown on page 2

300 Series PA Pump and Cooler Assemblies

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Rexroth Hydraulic Pump A10VO Series User Manual

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Air Eliminators and Combination Air Eliminators Strainers

PBX Series Quick Fit Connector Bimetallic Steam Traps

Cryogenic Vacuum Pumps

Compact, High-Flow Gas Regulators

Master Catalogue I August 2011

Submersion/Insertion Toroidal Sensor

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Technical Guide 08/15/14

SunMaxx Solar Filling Station Operating Instructions

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Model 1210C Battery Powered Pump Shown. Description

Flat Bottom Long Ram Hydraulic Jack

TECHNICAL DATA. Dry 122a. November 12, 2013

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

1805 Series Relief Valves

! WARNING. Before using product, read and understand instructions.

Select Radiators Installation Guide

ALMATEC Series CX CX 10 CX 130

HYDROSTATIC TEST PUMPS

PREPIPED LIQUID FUEL MANIFOLDS PLPM

Instructions and precautions. Fork Height. Visit our website at:

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

Hydraulic control unit series

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

PVH131/141 Variable Displacement Piston Pump - 11 Design

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Doc. No. NDP 015M-15 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-10 series

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Pump Maintenance - Repair

Line to Refrigerator Ice/Water Dispenser

Float and Thermostatic Traps Series H, C and X

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

Maintenance and Service Instruction

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

DESIGN STANDARDS SECTION

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

VALVES FOR REFRIGERATING SYSTEMS

Flushing and Cleaning the A/C System

Trouble Shooting. Pump

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Assembly and Installation Procedures

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Models SFP33 & SFP32 Pressure Transmitters

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

MODEL G300 BRAKE BLEEDER

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

INSTALLATION MANUAL MODEL RP-100

V47 Series Temperature Actuated Modulating Water Valves

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

2" & 3" Poly Wet Seal Pump Instruction Manual

Carburetion Troubleshooting Quick Reference Guide

Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*

Dryaire Desiccant System

STC 3S A Series Solenoid Valves

COUNTERBALANCE VALVES

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

MODEL INSTALLATION INSTRUCTIONS

PET-10 INSTRUCTION MANUAL PRESSURE TANK

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Transcription:

Phone: 800-669-1303 or 801-561-0303 Fax: 801-255-2312 e-mail: treborservice@idexcorp.com PURUS 20 Operation / Maintenance Manual SERIAL NUMBER (located on back of product): PATENTS: U.S. 7.134.849, 7.021.062 06/10/13 MP20

CONTENTS 1 INTRODUCTION... 3 2 INSTALLATION... 4 2.1 UNPACKING... 4 2.2 UTILITIES / HOOK-UP... 4 3 TEMPERATURE AND PRESSURE LIMITS... 6 3.1 HIGH TEMPERATURE OPERATION... 6 3.2 HIGH BACK PRESSURE OPERATION... 6 4 OPTIONS... 7 4.1 FLUID PORT CONNECTION OPTIONS... 7 4.2 HOOK-UP WITH SURGE SUPPRESSOR... 7 5 START-UP... 8 5.1 PERFORMANCE CHARTS... 8 6 INSPECTION AND MAINTENANCE... 10 6.1 MAINTENANCE... 10 6.2 PART REFERENCE ILLUSTRATION P20... 10 6.3 PART REFERENCE LIST P20... 10 7 TROUBLESHOOTING... 11 8 WARRANTY... 12 P20 PUMP OPERATION / MAINTENANCE MANUAL CONTENTS

1 INTRODUCTION PFA injection molded high purity disposable pump. TREBOR S Purus 20 diaphragm pump addresses maintenance, rebuild, and cost issues common in many chemical pumps by using an injection molded PFA design with minimal welded parts. This design (Figure 1-1) creates a reliable, disposable pump that costs less than many competitor pump rebuild kits. The Purus 20 provides peace of mind because of its purity, performance, and simplicity. Figure 1-1: Injection Molded & Welded Design Purus pumps can be externally controlled or installed as a self-contained unit using TREBOR S PC7 (Figure 1-2) air-powered pump controller that mounts on the Purus 20, as shown in (Figure 1-1). Figure 1-2: Optional PC7 Controller Product Benefits Operating life exceeding 100 million cycles in many applications Excellent suction lift and priming capability No elastomer seals or gaskets to replace No metal parts to corrode or contaminate process Compact size 100% PFA/PTFE construction for the chemical compatibility and process purity FM4910 compliant Cleaned, assembled, and packaged in Class 1000 cleanroom CE Certified P20 PUMP OPERATION / MAINTENANCE MANUAL PAGE 3

2 INSTALLATION 2.1 UNPACKING After unpacking, the pump should be checked for any damage that may have occurred during shipment. Damage should be reported to the carrier immediately. NOTE: Although extensive efforts are made to deliver pumps to our customers completely dry, new pumps may contain residual moisture from their final DI water test. The following items should be included within the shipping container: Qty Item Description 1 1 1 PURUS 20 MP20 PC7 2.2 UTILITIES / HOOK-UP Purus 20 Pump Manual, Purus 20 pump PC& Pump Controller (optional) The pump is mounted using four ¼ (6mm) bolts. It is recommended that the pump be positioned within 15 from level to maintain self-priming ability and pumping efficiency. Allow sufficient room for tubing connectors. Figure 2-1: Dimensions (with mounted PC7 option & flare connection) PAGE 4 P20 PUMP OPERATION / MAINTENANCE MANUAL

Air Inlet: Air Supply: 3/8 OD Tubing) 20-80 PSIG (0.14-0.55 Mpa), clean dry air or inert gas Fluid Ports: 1/2 Flaretek standard (other options available) For maximum flow the following is recommended: 1. Maximize supply line diameter 2. Minimize supply line length 3. Minimize supply line restrictions (i.e. valves, fittings) NOTE: It is recommended that a filter be placed on the discharge side of the pump. ATTENTION: The pump should be operated with clean, dry air or nitrogen. Particulate, water and oils in the air supply can damage the pump. P20 PUMP OPERATION / MAINTENANCE MANUAL PAGE 5

3 TEMPERATURE AND PRESSURE LIMITS 3.1 HIGH TEMPERATURE OPERATION The Purus 20 pump is molded out of virgin PFA. This enables high temperature operation under specific conditions. The maximum temperature will vary in relation to the supply pressure. Figure 3-1 shows Trebor s maximum recommended temperature for the pump. Exceeding the temperature for a corresponding supply pressure could cause the pump to develop leaks at the pump main seal between the air and fluid chambers. Figure 3-1: Purus 20 Recommended Temperature Curve 3.2 HIGH BACK PRESSURE OPERATION Increasing the fluid outlet pressure, or back pressure, causes stress on the pump main seal. High back pressure, around 90% of the supply pressure, can cause the pump to develop leaks at the main seal. It is not recommended to run the Purus 20 pump at near dead head conditions. High back pressure and elevated fluid temperatures can combine to increase the likelihood of pump failure due to a main seal leak. Higher temperature reduces the yield strength of PFA, while higher stresses are induced by the high back pressure. The combination of those two operating conditions can cause the main seal to unload, which can lead to a leak. Due to the potential variations in operating conditions, the typical range of material properties and the tolerance stack up, it is impossible to identify the exact points where main seal leaks become probable due to temperature/back pressure interactions. PAGE 6 P20 PUMP OPERATION / MAINTENANCE MANUAL

4 OPTIONS 4.1 FLUID PORT CONNECTION OPTIONS Additional options are available. Please contact Trebor Sales Department for details regarding available options. ½ Flaretek (standard) ½ Pillar, Super 300 (optional) 4.2 HOOK-UP WITH SURGE SUPPRESSOR For surge suppression, Trebor International recommends the use of the SS40 inline surge suppressor. Consult factory for installation and performance specifications. Information also available at www.treborintl.com NOTE: See Surge Suppressor Operation Manual for detailed installation instructions. P20 PUMP OPERATION / MAINTENANCE MANUAL PAGE 7

5 START-UP Open the fluid suction (IN) line valve, if necessary Open the fluid discharge (OUT) line valve, if necessary Pump air supply pressure should be regulated Operate pump at 20 psig initially to prime pump Increase pressure to attain desired flow, (not to exceed 80 psig) If the pump fails to start, refer to the troubleshooting section or contact Trebor for further assistance. ATTENTION: Prolonged periods (>5 minutes) of running without fluid can damage critical internal pump parts. CAUTION: When handling potentially dangerous fluids under pressure, the pump and its fittings should be placed in an enclosure away from operators. 5.1 PERFORMANCE CHARTS Pumping capacity is a function of air supply pressure and volume, suction head, suction line restrictions, discharge head, discharge line restriction, and fluid specific gravity and viscosity. Air Supply Pressure (PSIG) Discharge Fluid Pressure (PSIG) Flow (LPM) Cycles Per Minute Displacement cc Per Cycle Air Consumption (CFM) 20 0 14 100 140 4.6 20 10 11 100 110 40 0 18.5 180 103 6.0 40 20 12.5 104 125 60 0 20 210 95 7.0 60 30 15 110 137 80 0 21 218 97 8.0 80 40 16 132 121 Table 5-1: Performance Chart NOTE: Test information is based on specific conditions and limited sampling. Use for general reference only. This information is preliminary and may be changed at a future date. PAGE 8 P20 PUMP OPERATION / MAINTENANCE MANUAL

DISCHARGE PRESSURE (PSIG) DISCHARGE PRESSURE PURUS 20 w/pc7 CONTROLLER PERFORMANCE CURVES 80 70 60 50 40 30 20 10 0 FLOW (LPM) 0 5 10 15 20 0 2 4 6 FLOW (GPM.) 5.62 4.92 4.22 3.52 2.81 2.11 1.41 0.70 0.00 Figure 5-1: Pressure and Capacity chart P20 PUMP OPERATION / MAINTENANCE MANUAL PAGE 9

6 INSPECTION AND MAINTENANCE 6.1 MAINTENANCE TREBOR S PURUS 20 has no serviceable parts, due to its welded and sealed construction. Please neutralize and dispose of the pump accordingly or contact the factory regarding methods of recycling. 6.2 PART REFERENCE ILLUSTRATION P20 6.3 PART REFERENCE LIST P20 Figure 6-1 Exploded View ILL NO QTY DESCRIPTION 1 2 HEAD 2 2 DIAPHRAGM 3 2 MAIN SEAL 4 2 PUSH PLATE 5 1 SHAFT 6 1 BODY ASSY 7 2 SUCTION SEAT 8 4 CHECK BALL 9 4 CHECK CAP 10 2 1/2T FLR NUT PAGE 10 P20 PUMP OPERATION / MAINTENANCE MANUAL

7 TROUBLESHOOTING Pump Will Not Start, Fails to Operate Cause: Solution: Insufficient air pressure Increase regulated supply pressure or check control valves for proper operation. Rotate PC7 speed control screw CW until it stops. Then readjust for correct speed (if applicable). Debris in shuttle valve Inspect/clean control valve assembly. PC7 (if applicable) Refer to PC7 Manual Bubbles in Fluid Discharge Cause: Solution: Inlet line fittings not tight Check and tighten all fittings on the suction line feeding the pump. Flow too high Under high flow conditions some fluids can cavitate releasing dissolved air bubbles. Diaphragm failure due to puncture Contact Trebor Customer service for additional service recommendations. Replace pump. Fluid Leaks Cause: Solution: Weld failure of fluid pump Replace pump (Non Serviceable) Fluid leaking from suction or discharge connections Erratic Cycling Cause: Inspect tubing and tighten fluid fittings. Solution: Debris in shuttle valve Inspect/clean control valve assembly. PC7 (if applicable) Refer to PC7 Manual P20 PUMP OPERATION / MAINTENANCE MANUAL PAGE 11

8 WARRANTY See the Trebor Standard Limited Warranty at: http://www.treborintl.com/technicalsupport.aspx PAGE 12 P20 PUMP OPERATION / MAINTENANCE MANUAL