Chest Freezers Service Manual

Similar documents
Troubleshooting Your Refrigerator

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.


GENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).

ON-VEHICLE INSPECTION

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

LOBOY 16 AIR CONDITIONERS

AFE424 SERVICE PARTS

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Failure code manual. content

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Installation & operating instructions

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

T-Series Air Conditioner T62 Model

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

USER S MANUAL HSC-24A

HVAC-02, Air Conditioning Troubleshooting and Repair

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE & MAINTENANCE MANUAL

, User s Manual

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL. Rev. S 2014 Pentair Equipment Protection P/N

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

Instructional & Operating Manual

Split units TH with hermetic compressors

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Heating and Air Conditioning

Heat Pump Water Heater IOM Manual

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

T-Series Air Conditioner

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Cooling system components, removing and installing

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Panel Mounted Air Conditioners by Dantherm, Inc.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

REFRIGERATOR INSTRUCTION MANUAL. Model No.: MCBR170W/B/S

HVAC. (w) HVAC SYSTEM. Blower unit. (See BLOWER UNIT REMOVAL/INSTALLATION.) (See BLOWER UNIT DISASSEMBLY/ASSEMBLY.) Air filter

Wine Cooler with Thermo-Electric Cooling & Heating Technology

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

SERVICE Manual AIR CONDITIONER AWH090ZE0K. 1. Precautions. 2. Product Specifications. 3. Installation and Operating Instructions

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

SERVICE MANUAL REFRIGERATION

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL. Rev. F 2013 Pentair Equipment Protection P/N

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. F 2016 Pentair Equipment Protection P/N

Operating Instructions Split System Air Conditioner

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

WINDOW ROOM AIR CONDITIONER

Marine Refrigerator/freezer CR 195 & CR 195 Stainless Steel-INOX

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Gas Oven Repair Guide

Air Conditioning Sign-Off Sheet

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

HEATER, AIR CONDITIONING AND VENTILATION

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

DTC B1423/23 Pressure Sensor Circuit

4.4 CU.FT. REFRIGERATOR INSTRUCTION MANUAL HMBR445BE HMBR445SE

How to Maintain an Air Conditioner

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

CORNER FRIDGE THERMOLUX TL6 - TL10 - TL16 INSTALLATION AND OPERATION INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

MACS Recommended Service Procedures

Meaco 30L and Meaco 40L dehumidifier instruction manual

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

BMG/TMG -27, 48, 52, 74, 80 LAE CONTROLLER Installation & Operations Manual

Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt

How To Power A Car With A Fan And A Fan (Power)

INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER

Geyser-R Heat pump water heater Installation manual

Use and Care Manual. Model CPA12KH AIR CONDITIONER

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

PORTABLE AIR CONDITIONER

WH/WIH/WIHD/WIHD&M/WIHL AND WIH SERIES

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air


Cooling system components, removing and installing

Transcription:

Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Chest Freezers Service Manual Please read this manual completely before attempting to install or operate this equipment! www.turboairinc.com

Specification: Subject to change without notice. SPECIFICATION Classification Power Source Volume Rated Current Rated Power Input Power Consumption High side /Low side pressure Refrigerant Overall Dimension Net Weight/Gross Weight 138 Liters (4.9 cu.ft) 2.0 Amp. 135 Watts 1.30 kw h/24h 155psig/-2.22psig HFC-134a (Tetrafluoroethane) CF3CH2F 115gm 695(W) x595(d) x 910(H) mm 45 Kg./50 Kg. Direct Cool, Manual Defrost, Tropical 115VAC, 60 Hz. PRODUCT SPECIFICATION Classification Color/Door Body Finish Temperature Control Defrost System Drain Evaporator Condenser Cabinet Insulation Freezer Door R efrigerant Refrigerant Charge (gm.) Door Lamp Fan Motor Compressor Compressor Oil PTC Starter Overload Protector Dryer (Desiccant) Overall Dimension (W x D x H mm.) Packing Dimension (W x D x H mm.) Net Weight (kg.) Gross Weight (kg.) Sliding glass Door, Direct Cool, Tropical White/ with Door Lock Sliding Glass Baked Acrylic Powder Coat Thermostat Manual Defrost Manual Drain Tube Type Tube Type Rigid Polyurethane Foam (Blowing Agent CP) Rigid Polyurethane Foam HFC-134a (Tetrafluoroethane) CF3CH2F 115 gm None None KONOR GQY50AD 135 Watts 290 ml.poe Polyol Ester (Synthetic) 8115PTH7M4R7MC1 (3.85.6, Max current 18A/180V) 11650X011 signt0296/74/t0296/05,b94-130-74,4tm762pbfzz-51(6.3):cut temperature:115-125 ;Close temperature:70-52 ;Overload current 27A;UTC(Min action current):3.36a/70 15 gm. 695(W) x595(d) x 910(H) mm 765 (W) x 680 (D) x 970(H) mm 45kg. 50 kg. CHARACTERISTIC Temperature Control Operating Temperature ( C) Dial Position WARM 1-10.0 C ± 2 C NORMAL 4-15.0 C ± 2 C COLD 7-20.0 C ± 2 C

ELEC. CIRCUIT: COOLING SYSTEM

PARTS LIST of

Exploded View of

CHARACTERISTIC Parts Name Compressor :TSD- 27CF PTC Starter : TSD- 27CF Overload Protector : TSD- 27CF Picture Check Method and Criterion Measure the resistance with a tester. (Ambient temperature : Room temperature 25 c) Main Wiring Auxiliary Wiring 7 8 9.9 11.3 KONOR Normal GQY50AD (Approx.)S (Approx.)S 135 WATTS Open( Ω ) or Short Circuited ( 0 Abnormal Ω ) Measure the resistance with a tester. (Ambient temperature : Room temperature 25 c) 8115PTH7M4R7MC1 Normal (3.85.6, Max current 18A/180V) Abnormal Open( Ω ) or Short Circuited ( 0 Ω ) Measure the resistance with a tester. (Ambient temperature : Room temperature 25 c) T0296/74/T0296/05,B94-130-74,4TM762PBFZZ- 51(6.3) Less than 1 Ω (Approx.) Cut temperature:115- Normal 125 ;Close temperature:70-52 ;Overload current 27A;UTC(Min action current):3.36a/70 Abnormal Open( Ω ) TROUBLE SHOOTING Thermostat PTC Starter Overload Protector 1. Set Thermo Knob to OFF position, pull & straightened feeler bulb 2. Remove Thermostat cover and pull out Thermostat from Thermo Box 3. Short the thermostat terminal and check, if compressor runs. 4. Replace thermostat 5. After replacing Thermostat, reverse steps above. 1. Release Relay Cover Fixing Clip. 2. Remove Relay Cover. 3. Remove PTC Starter 4. Pull out PTC Starter, check if open and compare value of resistance with given value, if not 5. Hold receptacle terminal then pull electrical wire from PTC Starter. 6. Replaces PTC Starter (change overload protector together), reverse the steps above. 1. Check for continuity on overload protector, if open 2. Pull out Overload Protector. 3. Hold receptacle terminal then pull electrical wire from Overload Protector. 4. Replace overload protector.

Cause Check Point Correction Compressor Check coils resistances 1. Replace compressor if measured resistances differ from given standard 2. Abnormal noise Not cooling Insufficient cooling Malfunction due to leaks or clogged system Check thermostat setting Check gasket gap Charged (purge) with nitrogen into the refrigeration system & check for leaks on welds or clogs 1. Operate unit for 10 minutes with thermostat set at maximum 1. Check if gap can be resolved by adjustment of door hinges fixing screws. 2. Defrost if accumulation of frost is more than 10mm. 1. Check for clog or leak in the cooling system. 2. Repair or replace the clogged or leak section. 3. Evacuate and change filter dryer. 4. Purge with nitrogen to clean and check for leaks 5. Recharge refrigerant, test run and seal system TROUBLE INSPECTION REMEDY No Power Check electric power supply voltage Open circuit breaker or fuse Open Fuse CAUSES Fix or replace Replace No Light Check electrical circuit Worn out or defective A/C cord Replace Check lamp Open Replace Check lamps socket Corroded Replace Low Cooling Check for thermo setting Setting too low Set thermostat higher Defective Cooling System Check leaks Check Thermostat Deform or warp door gasket. Poor weld on joints Over storage or load or heavy frost accumulation Check if compressor runs by shortening thermostat Adjust door hinges fixing screws Repair, purge with nitrogen re-charge refrigerant and test run. Reduce or re-arrange load or defrost unit Replace thermostat if compressor runs. Check PTC starter resistance against given value Check Overload Protector Check for leaks Check Compressor resistance against given specification Check Pipe System Open, no resistance or differ from given value Check for continuity Leaks or poor welds on joints Defective Clogged Pipe System or oil choke Replace PTC starter. Replace if open. Repair, re-weld, purge, evacuate and recharge refrigerant Replace, weld, purge, check for leaks and recharge refrigerant, test run and seal system 1. Evacuate then Purge with nitrogen to remove clogs 2. Repair or replace clogged section, evacuate, purge, check leak and recharge refrigerant. Test Run and seal system