USB-500 Series Stand-Alone, Low-Cost Data Loggers



Similar documents
USB-500 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

EL-USB-1-LCD Temperature Data Logger with LCD


EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

EL-USB mA Current Loop USB Data Logger

Data Logging Solutions from Lascar Electronics

Temperature Datalogger Users Manual

Data Loggers for Real Time Temperature Monitoring - WiFi

User Manual. Humidity-Temperature Chart Recorder. Model RH520

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

DataView DVTH Data Logger for Temperature and Humidity

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

USER S GUIDE Humidity and Temperature USB Datalogger

Temperature & Humidity SMS Alert Controller

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

4-Channel Thermometer / Datalogger

FT-1000/GPS-N. System of remote monitoring and control of physical

User Guide. Temperature and Humidity Datalogger. Model 42280

SMS GSM Alarm Messenger

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Wireless Data Logger Monitoring Systems

Energy Monitoring Solutions

SupcoLog Logger Interface Software

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

NEW. EVEN MORE data acquisition and test stand automation

Instruction Manual. T3111 T3111L T3111P T3111Ex

Current Monitoring Kit QUICK START GUIDE

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Current Monitoring Kit

SOLAR I-V Rel /07/10

SNMP Web Management. User s Manual For SNMP Web Card/Box

New thermometers and accessories to grow your business

Multifunction HVAC and IAQ Meter

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Multi-Range Programmable DC Power Supplies 9115 Series

Fluke 3000 FC Series Test Tools Technical Data

Call for Mechanical Engineering, Electrical Engineering, and Computer Engineering Senior Design Project Proposals

Frequency selective monitoring and logging of environmental electromagnetic fields

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

A-Series Data Loggers PRODUCT MANUAL

Premium Server Client Software

Long Distance Industrial Wireless Transmitters and Receivers

NETWORK ENABLED EQUIPMENT MONITOR

Dual Laser InfraRed (IR) Thermometer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

GSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA

BIOMEDICAL REFRIGERATORS

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

T0118 T2118 T3118. Instruction Manual

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Measurement data monitoring system

Multi-Range Programmable DC Power Supplies 9115 Series

5000V Graphical Megohmmeter Model 5070

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Temperature & Humidity SMS Alert Controller

Disturbance Recoder SPCR 8C27. Product Guide

Fluke 3000 FC Series Test Tools Technical Data

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

Simplify Data Acquisition with a Built-in LXI Web Server

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

securityprobe5es -X20

User's Guide DylosLogger Software Version 1.6

REMOTE MONITORING AND CONTROL SYSTEM

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Centro-Matic Automatic Lubrication Systems System Controls

EVAL-UFDC-1/UFDC-1M-16

EM Family Datasheet. Overview. Easy to install at any scale

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Nardalert S3 Non-Ionizing Radiation Monitor

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

securityprobe 5E Standard

HOBO U14 Data Logger User Manual

Ron 3025 Crane Scale with 1"/25mm Display

Committing to the future. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

STERILIZERS, LABORATORY DRYING OVENS

Affordable wireless monitoring without compromise

Electronic Control Devices The European Product Catalogue 2007

1000 Series Data Loggers PRODUCT MANUAL

USER MANUAL V5.0 ST100

Hand-held thermometer Model CTH7000

Simple Logger II Data Loggers

How To Use A Ds340 (Dsp)

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Integrating Sound Level Meter and Datalogger

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

SDI Multi Sensor Module with Charger Enclosure Station Support

Transcription:

Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use software to set sample rate, alarms, and start time Easily display, graph, and save data in formats such as.csv to import into Excel Summary The USB-500 Series of stand-alone data loggers record temperature, humidity, voltage, or current readings. The user can easily set up the logging rate and starttime, log data, then download the stored data by plugging the module straight into a PC s USB port with the included software. Relative humidity, temperature, and dew point data can then be graphed, printed, and exported to Excel. Each data logger is powered by a long-life lithium battery which will last for up to a full year. Several models are available with different measurement input types, sample rate, and amount of built-in memory. Analog Input One or two channels are available on USB-500 Series data loggers. Units are available with temperature, thermocouple, humidity, voltage, or current inputs. USB-500 Series loggers offer low-cost, stand-alone data collection for temperature, humidity, voltage, or current Each logger can be programmed with sample rates from 0.1 Hz to as long as 12 hours depending on user requirements and length of data collection needed. Data is stored onto the logger and then uploaded to a PC via USB when collection is complete. Status LEDs USB-500 Series loggers feature one or two LEDs which indicate logging status, alarm condition, battery, and memory status. Real-Time LCD Display The USB-501-TC-LCD and USB-502-LCD feature a built-in LCD for real time display of data. The LCD can display current and max/min stored temperature and humidity values. USB-500 Series Model Channels Measurement Type Memory Features USB-501-LT 1 temperature 15 min to 2 h 4 K readings USB-501 1 temperature 0.1 Hz to 12 h 16 K readings USB-501-PRO 1 temperature 1 Hz to 12 h 32 K readings extended temp. range USB-501-TC 1 thermocouple 1 Hz to 12 h 32 K readings USB-501-TC-LCD 1 thermocouple 1 Hz to 12 h 32 K readings built-in LCD display USB-502 2 temperature, humidity 0.1 Hz to 12 h 16 K readings USB-502-LCD 2 temperature, humidity 0.1 Hz to 12 h 16 K readings built-in LCD display USB-502-PLUS 2 temperature, humidity 0.1 Hz to 12 h 16 K readings increased accuracy USB-503 1 0 to 30 VDC 0.1 Hz to 12 h 32 K readings USB-504 1 4 to 20 ma 0.1 Hz to 12 h 32 K readings Measurement Computing (508) 946-5100 1 info@mccdaq.com mccdaq.com

General Information & Software Included with each USB-500 Series data logger is an easy to use software application which provides the ability to set sample rate, alarms, temperature scale, and start time. Logging parameters, alarms, and start time are all set up via easy to use dialog boxes. The included software also displays, graphs, and saves data to a file. Maximum and minimum values are noted., humidity, and dew point are also displayed. Data can also be exported into formats such as MS Excel. The included data logger software will display recorded measurements in an easy to read chart. Movable cursors provide data values along with time stamp., humidity, and dew point measurements are displayed. In addition, high and low alarms are also shown. All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. USB-501-LT Lowest Cost Logger Measurement Range: -10 C (+14 F) min, +50 C (+122 F) max Resolution: +1 C (+2 F) typical Accuracy (Overall Error): ±2.5 C (±4.5 F) max Intervals: 15 min, 30 min, 1 h, 2 h Max Samples: 4,080 High Temp Alarm Range: -10 C (+14 F) min, 79.5 C (175 F) max Low Temp Alarm Range: -10 C (+14 F) min, 79.5 C (175 F) max Temp Resolution: 0.5 C (1 F) CR1620 Lithium Button Cell Life: @ 30 minute logging rate, 1 month min Operating Range: -10 C (+14 F) min, 50 C (122 F) max Dimensions: 68 mm long x 18 mm wide x 9.4 mm high (2.7 in. long x 0.7 in. wide x 0.4 in. high) USB-501 Logger Measurement Range: -35 C (-31 F) min, 80 C (176 F) max Accuracy (Overall Error): ±1 C (±2 F) typical Intervals: 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Max Samples: 16,382 High Alarm Range: -35 C (-31 F) min, 79.5 C (175 F) max Low Alarm Range: -35 C (-31 F) min, 79.5 C (175 F) max Resolution Range: 0.5 C (1 F) 1/2-AA 3.6 V Lithium Battery Life: @ 1 minute logging rate, 1 year min Moisture and Dust Protection: Protective cap installed, IP67 Operating Range: -35 C (-31 F) min, 80 C (176 F) max Dimensions: 98 mm long x 26 mm wide x 26 mm high (3.86 in. long x 1.02 in. wide x 1.02 in. high) Measurement Computing (508) 946-5100 2 info@mccdaq.com mccdaq.com

USB-501-PRO Logger with Rugged Enclosure Measurement Range: -40 to +125 C (-40 to +257 F) Resolution: 0.1 C (0.2 F) typical Accuracy (Overall Error): ±0.2 C (±0.4 F) typical, ±0.5 C ( ±1.0 F) max, when operating between 0 C and 40 C Intervals: 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Samples: 32,510 Data Rollover: Software configurable; allows unlimited logging periods by overwriting the oldest data when the memory is full High Alarm Range: -40 C (-40 F) min, 124.5 C (256 F) max Low Alarm Range: -40 C (-40 F) min, 124.5 C (256 F) max Alarm Resolution: 0.1 C (0.2 F) typical 2/3-AA 3.6 V Lithium Battery Life @ -20 C and a 10 second logging rate, 1 year, min, @ +80 C and a 10 second logging rate, 2 year, typical @ -40 C (-40 F) min to +125 C (+257 F) max, 3 year max Operating Range: -40 C (-40 F) min to +125 C (+257 F) max Moisture and Dust Protection: Protective cap installed, IP67 Corrosion Protection: Stainless steel housing, 316 grade Dimensions: 111 mm long x 20 mm wide x 20 mm high (4.37 in. long x 0.787 in. wide x 0.787 in. high) USB-501-TC Thermocouple Logger The USB-501-TC can log temperatures as detailed below using thermocouple sensors. However, the data logger should not be subjected to temperatures outside the operating temperature range of -10 to +40 C (+14 to +104 F). The K-type thermocouple probe that ships with the USB-501-TC is rated from 0 to 400 C (32 to 752 F). Measurement Range: K-type thermocouple: -200 to +1350 C (-328 to +2462 F) J-type Thermocouple: -200 to +1190 C (-328 to +2174 F) T-type Thermocouple: -200 to +390 C (-328 to +734 F) Accuracy (Logger Error): ±1 C (±2 F) typical Intervals: 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Max Samples: 32,510 High Alarm Range: -200 C (-328 F) min, 1349.5 C (2461 F) max Low alarm Range: -200 C (-328 F) min, 1349.5 C (2461 F) max Alarm Resolution: 0.5 C (1 F) 1/2-AA 3.6 V Lithium Battery Life: @ 1 minute logging rate, 6 months typical Operating Range: -10 C (+14 F) min to +40 C (+104 F) max Dimensions: 118 mm long x 27 mm wide x 27 mm high (3.86 in. long x 1.02 in. wide x 1.02 in. high) USB-501-TC-LCD Thermocouple Logger with LCD Measurement Range K-type Thermocouple: -200 to +1350 C (-328 to +2462 F) J-type Thermocouple: -200 to +1190 C (-328 to +2174 F) T-type Thermocouple: -200 to +390 C (-328 to +734 F) Accuracy (Logger Error): ±1 C (±2 F) typical Note: The USB-501-TC-LCD ships with a K-type thermocouple probe rated from 0 to 400 C (32 to 752 F). The USB-501-TC-LCD can log temperatures as detailed above using thermocouple sensors. However, the data logger should not be subjected to temperatures outside the operating temperature range of -10 to +40 C (+14 to +104 F). Intervals: 1 s, 2,s, 5 s, 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Samples: 32,510 max Data Rollover: Software configurable: allows unlimited logging periods by overwriting the oldest data when the memory is full. High Alarm Range: -200 C (-328 F) min, 1349.5 C (2461 F) max Low Alarm Range: -200 C (-328 F) min, 1349.5 C (2461 F) max Alarm 1/2-AA 3.6 V Lithium Battery Life: @ 25 C and 1 minute logging rate, 6 months typical Operating Range: -10 C (+14 F) min to +40 C (+104 F) max LCD Status Indicators The high-contrast LCD shows temperature data and information regarding the logger status. ( C/ F): Current temperature, stored max, and stored min values LCD Mode Software Configurable: Always on; on for 30 seconds after the LCD button is pressed; always off Dimensions: 134.5 mm long x 23.9 mm wide x 21.2 mm high (5.29 in. long x 0.94 in wide x 0.83 in. high) Measurement Computing (508) 946-5100 3 info@mccdaq.com mccdaq.com

USB-502 & Humidity Logger Measurement Range: -35 C (-31 F) min, 80 C (176 F) max Repeatability: ±0.1 C (±0.2 F) typical Accuracy (Overall Error): ±0.5 C (+1 F) typical, ±2 C (±4 F) max Dew Point Accuracy (Overall Error): ±1.1 C (±2 F) typical Note: Specifies the overall error in the calculated dew point, for relative humidity measurements between 40 and 100% RH at 25 C Software Configurable: -35 to 79.5 C (-30 to 175 F), high and low alarms Accuracy (Overall Error): ±3.0 typical : 0 to 99.5 (high and low alarms) Software Configurable: 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Samples: 16,382 max Relative Humidity Samples: 16,382 max Logging Modes: Immediate and delayed start Source: 1/2-AA 3.6 V lithium battery Note: Battery lifespan is dependent on the sample rate and ambient temperature Operating Range: -35 C to 80 C (-31 F to 176 F) Ingress Protection: Meets IP67 Standard with protective cap installed Dimensions: 103 mm long x 26.4 mm wide x 26.4 mm high (4.06 in. long x 1.04 in. wide x 1.04 in. high) USB-502-LCD & Humidity Logger with LCD Measurement Range: -35 C (-31 F) min, 80 C (176 F) max Note: At temperatures below -20 C (-4 F), the LCD may exhibit slower response time of approximately 10 seconds. Repeatability (Short Term): ±0.1 C, ±0.2 F typical Accuracy (Overall Error): ±0.5 C typical, ±2 C max; ±1 F typical, ±4 F max Internal Resolution: 0.5 C, 1 F typical Dew Point Accuracy (overall error): ±1.1 C, ±2 F typical Note: Specifies the overall error in the calculated dew point, for relative humidity measurements between 40 and 100% RH at 25 C. Software Configurable: -35 to 79.5 C, -31 to 175 F (high and low alarms) Accuracy (Overall Error): ±3.0 typical, ±6.0 max : 0 to 99.5 (high and low alarms) Software Configurable: 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 hr, 2 h, 6 h, 12 h Samples: 16,379 max Relative Humidity Samples: 16,379 max Logging Modes: Immediate, delayed start, and push to start (via the device s LCD button) Data Rollover Software Configurable: Allows unlimited logging periods by overwriting the oldest data when memory is filled LCD Status Indicators The high-contrast LCD shows temperature data and information regarding the logger status. ( C/ F): Current temperature, stored max, and stored min values Relative humidity (%RH ): Current relative humidity, stored max, and stored min values LCD Mode Software Configurable: Always on; on for 30 seconds after the LCD button is pressed; always off Source: 1/2-AA 3.6 V lithium battery Note: Battery lifespan is dependent on the sample rate, ambient temperature, and use of the LCD screen. Operating Range: -35 C to 80 C (-31 F to 176 F) Note: At temperatures below -20 C (-4 F), the LCD may exhibit slower response time of approximately 10 seconds Dimensions: 126.0 mm L x 24.1 mm W x 25.3 mm H (4.96 in. L x 0.95 in. W x 1.00 in. H) USB-502-PLUS & Humidity Logger with Increased Accuracy Measurement Range: -35 C (-31 F) min, 80 C (176 F) max Repeatability: ±0.1 C, ±0.2 F typical Accuracy (Overall Error): ±0.3 C typical, ±1.5 C max; ±0.6 F typical, ±3 F max Internal Resolution: 0.5 C, 1 F typical Dew Point Accuracy (Overall Error): ±1.1 C, ±2 F typical Note: Specifies the overall error in the calculated dew point for relative humidity measurements between 40 and 100% RH at 25 C Software Configurable: -35 to 79.5 C, -30 to 175 F (high and low alarms) Measurement Computing (508) 946-5100 4 info@mccdaq.com mccdaq.com

& Ordering Information Accuracy (Overall Error): ±2.0 typical, ±4.0 max : 0 to 99.5 (high and low alarms) Software Configurable: 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Samples: 16,382 max Relative Humidity Samples: 16,382 max Logging Modes: Immediate and delayed start Data Rollover Software Configurable: Allows unlimited logging periods by overwriting the oldest data when the memory is full. Source: 1/2-AA 3.6 V lithium battery Operating Range: -35 C to 80 C (-31 F to 176 F) Ingress Protection: Meets IP67 Standard with protective cap installed Dimensions: 103 mm long x 26.4 mm wide x 26.4 mm high (4.06 in. long x 1.04 in. wide x 1.04 in. high) USB-503 Voltage Logger Voltage Measurement Range: 0 Volts DC min., 30 Volts DC max Resolution: 50 millivolts DC Accuracy (Overall Error): ±1% typical Intervals: 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Max Voltage Samples: 32,510 Units: Volts DC High Voltage Alarm Range: 0-30 Volts DC High Voltage Alarm Resolution: 0.3 Volts Low Voltage Alarm Range: 0-30 Volts DC Low Voltage Alarm Resolution: 0.3 Volts USB Device Type: USB 2.0 (Full-speed) Source: 1/2-AA 3.6 V lithium battery life; one year, depending on ambient temperature, logging rate, and use of alarm LEDs Operating Range: -25 C (-13 F) min, 80 C (176 F) max USB-504 4-20 ma Current Logger Current Measurement Range: 4-20 ma DC typical Resolution: ±0.05 ma DC Accuracy (Overall Error): ±1%, ±1 count Intervals: 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 15 min, 30 min, 1 h, 2 h, 6 h, 12 h Max Current Samples: 32,000 Units: ma DC High Current Alarm Range: 4-20 ma DC High Current Alarm Resolution: 0.16 ma Low Current Alarm Range: 4-20 ma DC Low Current Alarm Resolution: 0.16 ma USB Device Type: USB 2.0 (Full-speed) Source: 1/2-AA 3.6 V lithium battery life; one year, depending on ambient temperature, logging rate, and use of alarm LEDs Operating Range: -35 C (-31 F) min, 80 C (176 F) max Ordering Information Description Part No. Battery-powered remote temperature logger measures and stores up to 4,080 temperature readings USB-501-LT Battery-powered remote temperature logger measures and stores up to 16,382 temperature readings USB-501 Battery-powered remote temperature logger with extended temperature range measures and stores up to 32,510 temperature readings USB-501-PRO Battery-powered remote thermocouple data logger measures and records temperatures from -200 to +1300 C USB-501-TC Battery-powered remote thermocouple data logger with LCD measures and stores over 32,000 temperature readings USB-501-TC-LCD measures and stores up to 16,382 relative humidity and 16,382 temperature readings USB-502 with LCD display measures and stores up to 16,379 relative humidity and 16,379 temperature readings USB-502-LCD with increased accuracy measures and stores up to 16,382 relative humidity and 16,382 temperature readings USB-502-PLUS Battery-powered remote data logger measures and stores up to 32,510 voltage readings USB-503 Battery-powered remote current loop data logger measures and stores up to 32,000 current loop readings USB-504 Measurement Computing (508) 946-5100 5 info@mccdaq.com mccdaq.com