The Right Glazing in the Right Place

Similar documents
Glass and Building Regulations Impact Safety

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

A Guide to Best Practice in the Specification and Use of Fire-Resistant Glazed Systems

Approved Document Q: Security

ONLINE VERSION. Glazing safety in relation to impact, opening and cleaning ONLINE VERSION

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

The replacement or modification of existing windows shall comply with the following requirements:

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

Number of Sides Required to Have a Handrail

SCHOTT PYRANOVA Planline System

Protection from falling. collision and impact. The Building Regulations edition for use in England* ONLINE VERSION APPROVED DOCUMENT

Services Enclosures and Protected Shafts - Maintaining Compartmentation

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Understanding fire-resistant glazing systems. Presented by Russell Day Technical officer The Glass and Glazing Federation

Rochdale Building Control Guide. Approved Document F Means of ventilation

Pilkington Decorative Glass Range. Pilkington Texture Glass Pilkington Oriel Collection Pilkington Optifloat Opal

Guide to Conservatory Installation and Sewers

Pyroguard Wired Glass

Understanding BS EN 771-3: Aggregate concrete masonry units

Workplace Health, Safety & Welfare

Condensation. Some Causes, Some Advice

Standard Door Specification

Pilkington Decorative Glass Range. Pilkington Texture Glass Pilkington Oriel Collection Pilkington Optifloat Opal

Extracts from BUILDING REGULATIONS

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES.

Code of Practice for fire resisting metal doorsets

This guide sets out what forms of shop front security will and will not be acceptable to the Council.

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Guidance on loft conversions in two-storey houses

PROOF ONLY. Police and Fire Service Home Security & Fire Safety Checklist. Student Accommodation Security Checklist

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

TOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.

Fire safety in timber buildings

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Wales for Replacement Doors and Windows Contents

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Conwy Deposit Local Development Plan (Revised edition 2011)

Loss Prevention Standard

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

MP 3.4 SWIMMING POOL BARRIERS. Table of Contents


REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION. Building Solutions Automotive Industry

Ministry of the Environment Decree on accessible building

Accessibility Design Advice

EXHIBITION DISPLAY RULES

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

Classification of reaction to fire of glass products Recommendation from Glass for Europe

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

The Work at Height Safety Association. Guidance on inspecting eyebolts used for personal fall protection purposes

DOMESTIC WINDOW SECURITY

Charter Township of Shelby Harry Reese Building Director

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Decorative solutions made of glass

Rockwool Flexi Insulation Application Guide

The BASA Guide to the ISO Classification of Sealants for Building Construction

best practice guide BS EN 1154 Controlled Door Closing Devices to in association with

2010 edition. Handbook of. Fire-Rated Glass. for schools

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

Decoration. The Pilkington Texture Glass Range

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

FIRE DETECTION AND ALARM SYSTEMS

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

Walking and Working Surface Checklist:

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

Your essential guide to CE Marking

glass & Glazing Products

Squash Court Design general points

BUILDING PERMIT SPECIFICATIONS

BUILDING A FENCE? THE CITY OF CAMBRIDGE REQUIRES THAT ALL FENCES WITHIN THE CITY CONFORM TO THE REGULATIONS OF FENCE BY-LAW

Routers and machining centres

LAMINAR FLOW CABINETS

Planet Frameless Glazing. Planet 20 frameless glass swing door

Does Wall Township require an inspection by the building department on resale of a home?

CHAPTER 24 GLASS AND GLAZING

Europeiskt Tekniskt Godkännande European Technical Approval

Technical Bulletin 005(A) Developed with Communities and Local Government

MagTek A. Aluminium Manual Attack Resistant Doors

INFORMATION REGARDING GLASS TYPES AND PROPERTIES

39HQ Airovision Air Handling Units

Bath Planning Guidelines With Access Standards

Installation Instructions

Rockwool Cladding Roll

European technical approval

ELECSA and the Fire Industry

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

How to secure your property after a disaster

Security Dwellings. The Building Regulations edition for use in England* ONLINE VERSION APPROVED DOCUMENT ONLINE VERSION

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

SmartPly OSB3 SMARTPLY

Building Regulations Technical Guidance Document K. Stairways, Ladders, Ramps and Guards

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

European Technical Approval ETA 13/0526

Transcription:

Always use a current GGF Member. To see the latest list of GGF Members visit www.ggf.org.uk/directory SAFETY AND SECURITY REFERENCE NUMBER 40.3 JULY 2014 The Right Glazing in the Right Place It is a legal requirement to install the right glazing in the right place. This will save lives.

03 Glass and Glazing Federation The Glass and Glazing Federation (GGF) is the recognised leading authority for employers and companies within the flat glass, glazing, home improvement, plastics and window film industries. GGF Members can be found in over 1,500 business locations throughout the U.K. Talk to the specialists All GGF Members follow a strict code of conduct that is laid down in the Federation s Code of Good Practice. By dealing with a GGF Member you reduce the risk of problems with any work carried out. The GGF logo on a company s literature or vehicles is a sign of quality and reliability. Insist on a GGF Member. Contents The Right Glazing in the Right Place: Use of safety glazing in critical locations Impact performance / Marking Table 1: Recommendations on class of safety glass or safety plastics to be used in critical locations Table 2: Nominal thickness and maximum pane size dimensions for glass not classified in accordance with EN 12600 that may be used in specific critical locations with four edges supported (see BS 6262: Part 4 - clause 8.4b) 04 05 06 Critical Location (BS 6262: Part 4 clause 8) Figure 1: Critical Locations 08 Other considerations Figure 2: Permanent screen protection 10

04 05 The Right Glazing in the Right Place: Use of safety glazing in critical locations Impact performance / Marking Glazing in part of a door, wall or other part of a building likely to be subject to accidental human impact. Impact performance (see BS 6262: Part 4 clause 6) Marking (see BS 6262: Part 4 clause 7) The Building Regulations in England, Wales, Scotland and Northern Ireland have had requirements for Glazing subjected to human impact since the early 1990s. The appropriate documents are as follows: England Approved Document K: 2013 Wales Approved Document N: 1998 Scotland Technical Handbook 4.8 Northern Ireland Part V1 NOTE 1: England Approved Document K: 2013; Safety glazing is covered in K4 and manifestation of glazing K 5.2 NOTE 2: Wales Approved Document N formerly England & Wales Approved Document N 1998 incorporating 2000 and 2010 amendments The details of the requirements are incorporated into: BS 6262 Part 4:2005 Glazing for buildings Part 4: Code of practice for safety related to human impact. General BS 6262 Part 4 takes into account the following: The publication of harmonised European standards (hens) for glass products; Withdrawal of BS 6206: Specification for impact performance requirements for flat safety glass and safety plastics for use in buildings. For testing of flat safety glass. The publication of BS EN 12600; Glass in building-pendulum test-impact test method and classification for flat glass. Definitions (see BS 6262-4 - clause 3) The following definitions apply: Safety glass Glass product conforming to;- EN 572-3 Glass in building Basic soda-lime silicate glass products Part 3: Polished wired glass EN 572-6 Glass in building Basic soda-lime silicate glass products Part 6: Patterned wired glass EN 12150-1 Glass in building Thermally toughened soda-lime silicate safety glass Part 1: Definition and description EN ISO 12543-2 Glass in building Laminated glass and laminated safety glass Part 2: Laminated safety glass EN 14179-1 Glass in building Heat soaked thermally toughened soda-lime silicate safety glass Part 1: Definition and description EN 13024-1 Glass in building Thermally toughened borosilicate silicate safety glass Part 1: Definition and description that has a performance classification in accordance with EN 12600 Safety plastics Plastics glazing sheet material that has been classified in accordance with BS 6206 Unbacked mirror glazing Glazing which has either no backing or only partial backing behind its entire area, or has a backing that does not retain its integrity or is cracked or broken when tested as described in BS 7449: 1991 Specification for inclusion of glass in the construction of furniture, other than tables or trolleys, including cabinets, shelving systems, and wall hung or free-standing mirrors. Safety film The European standard for Adhesive backed polymeric filmed glass is under preparation. This product can be tested and classified in accordance with EN 12600 and can therefore be regarded as a safety glass. Safety glass Is tested and classified in accordance with EN 12600. The classification is as follows: α (β) Ф Where: α is the drop height at which the product either did not break or broke safely. β is the mode of breakage of the material. Ф is the drop height at which the product either did not break or broke in the fashion of laminated glass i.e. the broken glass offers containment. Safety plastics Is tested and classified in accordance with BS 6206. General Installed safety glass and safety plastics, in critical locations, shall be indelibly marked in such a position so that the marking is visible after installation. Safety glass Installed safety glass shall be clearly and indelibly marked with the following: The name or trade mark of the manufacturer, merchant or installer; The identifier of the product standard that the safety glass conforms to e.g. EN 12150, EN 14449 Glass in building laminated glass and laminated safety glass evaluation of conformity/product standard. etc. The classification according to EN 12600. Safety film Adhesive backed polymeric filmed glass should be marked as follows: Name or trade mark of manufacturer, merchant or installer; F for filmed glass; EN 12600 and classification. BS 6262-4:2005 requires only the first part of the marking designation. However, the full designation might be required to meet other regulatory requirements. Attention is drawn to the Building Regulations for all regions within the United Kingdom. Safety plastics Safety plastics shall be marked in accordance with BS 6206: 1981; clause 6.

06 07 Table 1 Table 2 Recommendations on class of safety glass or safety plastics to be used in critical locations Nominal thickness and maximum pane size dimensions for glass not classified in accordance with EN 12600 that may be used in specific critical locations with four edges supported (see BS 6262: Part 4 - clause 8.4b) Critical location Minimum recommended classification NOTE: BS6262: Part 4 clause 8.4b Only applies if the pane forms part of a frontage of a building e.g. shopfront that is not a dwelling, in which case glass recommended in Table 2 may be used. Safety glass a Safety plastics a Doors (see clause 8.2) Minor dimension of pane > 900 mm 2(β)Ф Class B Minor dimension of pane 900 mm 3(β)Ф Class C Normal thickness a 8mm Maximum pane size dimensions 1100mm x 1100mm Door side panels (see clause 8.3) Minor dimension of pane > 900 mm 2(β)Ф Class B Minor dimension of pane 900 mm 3(β)Ф Class C 10mm 12mm 2250mm x 2250mm 4500mm x 4500mm Low level glazed areas (see clause 8.4) Irrespective of pane dimensions 3(β)Ф Class C 15mm or thicker no limits Fully backed mirror glazing (see clause 8.5a) Minor dimension of pane > 900 mm 2(β)Ф Class B Minor dimension of pane 900 mm 3(β)Ф Class C a See BS 952-1. Glass for glazing Part 1: Classification Unbacked mirror glazing accessible from one side only (see clause 8.5b) Minor dimension of pane > 900 mm 2 0 (β)ф b Class B0 Minor dimension of pane 900 mm 3 0 (β)ф b Class C0 This leaflet outlines the recommended glazing to use in major risk areas. For example as detailed in the Building Regulations England, i.e. Approved Document K: 2013 Edition: Part K2 Protection from falling; Part K4 Protection against impact with glazing; Part K5 Additional provisions for glazing in buildings other than dwellings. The leaflet is also based on British Standard Code of Practice BS 6262 Part 4: 2005. NOTE: Scotland Technical Handbook 4.8 calls up BS 6262: Part 4 2005 as a deemed to satisfy requirement Bathing areas (see clause 8.7) Areas of special risk (see clause 8.8) Irrespective of pane dimensions 3(β)Ф Class C Irrespective of pane dimensions 3(β)Ф Class C a The second and third parts of the EN 12600 classification, ie (β)ф, are not required for the classification of safety glass in this British Standard. b In these locations the safety glass is only required to be tested and classified from the face that, when installed, is likely to be impacted. The safety glass should be marked with the classification 2 0 or 3 0 respectively, see clause 7. c These classifications are taken from BS 6206.

08 09 Critical location (BS 6262: Part 4 Clause 8) Figure 1 General Those areas of internal and external walls, see Figure 1, that are considered critical locations in terms of safety are: a) Between the finished floor level and 1500mm above that level in doors, and in side panels which are within 300mm of either edge of the door; b) Between the finished floor level and 800mm above that level in the case of windows not included in a) above; c) Mirrored doors and panels Robustness Robustness refers to the strength of the glazing that forms fronts to non-domestic buildings such as shops, showrooms, offices, factories and public buildings. Some glazing such as polycarbonate is inherently strong. Annealed glass that does not normally comply with EN 12600 can gain robustness with increased thickness. Annealed glass may only be used in critical locations, therefore, when the nominal thickness and dimensions are as listed in Table 2. Critical Locations 3 2 2 It is important to note that any part of a glass area affected must meet the requirements in its entirety and not just in the relevant section. Table 1 gives the minimum recommended safety glass and safety plastics for use in all critical locations. Exceptions There are instances where glazing other than safety glass and safety plastics are deemed to be satisfactory: Small Panes Ordinary annealed glass may be used in small panes up to a maximum width of 250mm and an area not exceeding 0.5m 2. Such glass must not be less than 6mm in thickness, except in the case of traditional leaded lights and copper lights, where 4mm can be used. Permanent Screen Protection If glazing in a critical location is protected by a suitably designed protective screen system the recommendations of clause 8 do not apply. The protective screen should: a) be independent of the glazing; b) prevent a sphere of 75mm diameter from touching the glazing (see Figure 2); c) if 900mm or more in length, it should be sufficiently robust to sustain a centrally applied force of at least 1350 N, (1100 N, if less than 900mm in length) without: 1) fracturing; 2) deflecting so as to impact the glass; 3) permanently distorting; 4) being displaced. If the protective system is multi-railed, each rail must satisfy this recommendation. If the glazing is installed behind a permanent robust screen, it need not itself comply with any other safety requirements provided the protected screen would prevent a sphere of 75mm diameter coming into contact with the glazing. 800mm 3 2 Key 300mm 1 See clause 8.2 2 See claus e 8.3}BS 6262-4: 2005 3 See clause 8.4 1 1 2 300mm 1500mm

10 11 Other considerations Figure 2 Areas of Special Risk In all those parts of buildings where the planned activity generates a special risk, for example indoor sports facilities, all glazing should conform to Table 1 within BS 6262 Part 4:2005. In these situations, the designer or specifier should consider if a higher class is required, or if additional safeguards such as protective rails or screens, or manifestation, are necessary Glazing in Non-Domestic Buildings Under some conditions of lighting, large areas of transparent glazing used to subdivide a building might not be readily apparent. The risk of human impact with this glazing is greatest if adjacent areas within or immediately outside the building are at the same level so that a person might reasonably assume unimpeded passage from one part to another. Permanent screen protection Glazing in Bathing Areas Any glazing forming part of a bath or shower screen, or located adjacent to, or surrounding, a bath, swimming pool, or other associated wet area, constitutes a potential danger because of the possibility of a person slipping on a wet surface. Such glazing should consist of a material recommended for bathing areas as specified in Table 1, unless this British Standard recommends that material of a higher class should be used (see 8.2 and 8.3). Glazing for prefabricated shower enclosures and shower cabinets should also conform to EN 14428 Shower enclosures functional requirements and test methods. Protective barriers Glazing in protective barriers should conform to BS 6180:2011 Barriers in and about buildings code of practice. Safety glass should be classified in accordance with EN 12600:2002 and safety plastics should conform to BS 6206:1981. For more detailed information see GGF Data Sheet 7.2: Guidelines for the Use of Glass in Protective Barriers. If the presence of such glazing is not sufficiently well indicated by mullions, transoms, door frames, large door handles, stall risers or other components of the glazing system, it should be made apparent by some form of manifestation. The manifestation employed should be of a sufficient size to make it immediately obvious. It can take the form of broken or solid lines, patterns or company logos, positioned between 600mm and 1500mm above floor level at appropriate horizontal intervals. The manifestation should preferably be permanent, e.g. etching of the glazing, but alternatively, if applied materials are used they should be durable and not easily removed. Further information can be found in the applicable Building Regulations, e.g. Approved Document K 2013 Edition For use in England Section K5.2 Existing Glazing The Workplace (Health Safety and Welfare) Regulations. The criteria and requirements of Regulation 14 impose the same requirements for existing glazing retrospectively; Every window or other transparent or translucent surface in a wall or partition and every transparent or translucent surface in a door or gate shall, where necessary for reasons of health and safety be of safety material or be protected against breakage of the transparent or translucent material and be appropriately marked or incorporate features to make it apparent. 800mm from floor level Less than 75mm screen glass or plastics 75mm Plan detail of screen screen Diagrams are used with kind permission of BSI.

Glass and Glazing Federation 54 Ayres Street London SE1 1EU T: 020 7939 9100 E: info@ggf.org.uk www.ggf.org.uk Follow us on Twitter: @GGF_News 2014 GLASS AND GLAZING FEDERATION