Liquid Oxygen Mother Unit/ Portable Flask System.

Similar documents
The Home Oxygen Handbook.

CARING FOR YOUR WATER HEATER

San josé OWNER S MANUAL

THE NEWCASTLE UPON TYNE HOSPITALS NHS FOUNDATION TRUST SAFE USE AND STORAGE OF LIQUID NITROGEN AND SOLID CARBON DIOXIDE (DRY ICE)

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Patient Manual. Oxygen Concentrator

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

NITROUS TRANSFER PUMP INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Medical gas cylinder data chart. BOC: Living healthcare

PC1131 Electric Air Compressor

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

Medical Gas Data Sheet (MGDS) Medical air

2-SLICE COOL TOUCH TOASTER

Oxygen for Symptom Relief (Palliative Oxygen)

PC1130 Electric Air Compressor

Tassimo The Art of the Perfect Cup

Medical Gas Data Sheet (MGDS) 9% helium/35% oxygen/nitrogen medical gas mixture

National- Spencer Inc.

Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

orlando OWNER S MANUAL

Care and Handling of Your VAIO Computer

ON-VEHICLE INSPECTION

Oxygen. Do not use flammable products, such as aerosol sprays, rubbing alcohol, paint thinners, and other oil-based lubricants near oxygen.

CAR SEAT/ STROLLER INSTRUCTION MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Oxygen Policy and Procedure

MAINTENANCE & TROUBLESHOOTING

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

ThermoStar Refrigeration Air Dryers

MAINTENANCE & TROUBLESHOOTING

Medical Gas Data Sheet (MGDS) 9% helium/35% oxygen/ nitrogen medical gas mixture

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Standard Operating Procedure Liquid Nitrogen Storage, Use & Transportation Guidance & Code of Practice

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Please read and keep these instructions. Run water through your machine before first use

Oxygen Therapy. A guide for the patient. Please bring to any outpatient appointments. Patients name. Exceptional healthcare, personally delivered

Wilesco D365, D366, D367, D368, D405, D406 D407, D409 Operating Instructions

OUTDOOR GAS FIREPLACE USER GUIDE North America _2 EF

Compressed Gas Cylinder Program

QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus. Operating Manual

Chapter 7 Hydraulic System Troubleshooting

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

U S E R M A N U A L. (CGA 870 Connection)

MATERIAL SAFETY DATA SHEET

Compressed Gas Cylinder Safety

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

TWO BURNER PROPANE CAMPING STOVE

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

NFPA31FuelOilPiping 1 Revised

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

RC HELICOPTER INSTRUCTION MANUAL

Your Portable Oxygen System. Use & Care Guide

Nokia Wireless Keyboard (SU-8W) User Guide

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Peasouper Operator s Manual

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Cylinder Leak- Down Tester

cairn HMO Tenant Information Property Address: Letting: Maintenance:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

NFC Communication Tray Model: HHX-IT3-Z

RISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Introduction. What does PICO do? How does PICO work?

What is Dry Ice? Dry Ice Company Safety Rules: DRY ICE: SAFETY DATA SHEET & RISK ASSESSMENT

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

19 LED Tube Controller ORDERCODE 41003

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

Draining and filling cooling system

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Record Cleaning Machine

TWO BURNER PROPANE CAMPING STOVE

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

FLUSHOMETER - TANK SYSTEM

X-Plain Foley Catheter Male Reference Summary

Tankless Water Heater

Bottom Loading Water Dispenser

Extraction: Separation of Acidic Substances

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Fuel. What you will learn. Things you need before you start. Materials. Tools. When you have finished this module, you should be able to:

CHROME FRONT BRAKE MASTER CYLINDER KIT

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Housing Services Guidance for tackling condensation, damp and mould in your home

PORTABLE AIR CONDITIONER

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Transcription:

Liquid Oxygen Mother Unit/ Portable Flask System. Equipment Guide. BOC: Living Healthcare

02 Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. Contents. 3 The basics 4 How to fill the portable flask 6 Liquid portable flask usage chart 8 Do s & Don ts 9 Troubleshooting

Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. 03 IMPORTANT: Please ensure you read all accompanying literature supplied prior to using your home oxygen equipment. In particular, pay attention to the section on not smoking or allowing others to smoke near your equipment. Liquid oxygen allows the storage of larger quantities of gas more readily than normal gaseous oxygen. One litre of liquid oxygen when evaporated equals approximately 860 litres of gaseous oxygen. The liquid oxygen is vaporized into gas and warmed to room temperature inside the equipment before it is delivered to you via tubing called a cannula, which fits into your nostrils. The liquid oxygen system for homecare consists of a stationary mother unit vessel and a portable flask for holding your ambulatory oxygen. The basics. Marathon unit (Lightweight portable flask). Companion unit (Standard portable flask). We can supply liquid oxygen systems to you depending on your prescription. A full risk assessment will be carried out by our Patient Service Representative (PSR) prior to installation to check that it is safe for installation. This system gives greater flexibility and allows for an increased level of mobility. You will be supplied with a compact mother unit which contains your reserve supply of liquid oxygen. This is used to refill the small portable flask with oxygen as and when you need it. Dependent on your Home Oxygen Ordering Form (HOOF), you will be supplied one of two different portable flasks as shown above.

04 Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. How to fill the portable flask. a b 1. Using a clean and dry cloth, wipe the male fill connector (b) on the mother unit and the female fill connector (a) on the portable flask (supplied by your PSR). 2. Position the portable flask over the recessed area on the top of the mother unit and carefully lower the portable flask into place so that the fill connectors are properly aligned. 3. Place one or both hands on top of the portable flask and press straight down directly over the fill connector. While holding the portable flask in the fill position, pull down and hold the vent valve lever in the open position, as shown. You will hear a hissing sound keep pressing down whilst the portable flask is filling. 4. When the portable flask is full, there will be a change in the sound of the gas followed by a dense white vapour forming around the mother unit s cover. Close the vent valve by returning the vent lever to the upright position.

Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. 05 5. Disengage the portable flask from the mother unit vessel by pressing the portable release button and lifting the portable flask off the reservoir, as shown. 6. Check the contents of the portable flask by lifting the contents indicator strap, ensuring the bottom back of the unit is straight, as shown. The green bar inside the clear window indicates how full your unit is.

06 Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. Liquid portable flask usage chart. How long will my portable flask last? Please note the duration is only approximate and for guidance only (shown in hours unless otherwise stated). The PSR will let you know which portable flask you have been supplied. The duration is based on a full portable flask. To identify the portable flask you have been supplied, please refer to the photos page 3. Companion 1000 portable flask Flow control setting (LPM) Duration (hours) 0.25 30.8 0.5 21.5 0.75 16.5 1 13.4 1.5 9.7 2 7.7 2.5 6.3 3 5.4 4 4.1 5 3.3 6 2.8 Companion 1000T (high flow) portable flask Flow control setting (LPM) Duration (hours) 0.5 21.5 1 13.4 1.5 9.7 2 7.7 3 5.4 4 4.1 5 3.3 6 2.8 8 2.1 10 1.7 15 1.2 Marathon portable flask Continuous flow setting Flow control setting (LPM) Duration (hours) C1 12.1 C2 6.1 C3 4.0 C4 3.0 C5 2.4 C6 2.0 Marathon portable flask Demand flow setting Flow control setting (LPM) Duration (hours) D1.5 29.3 D2 22.0 D2.5 17.6 D3 14.6 D4 11.0

Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. 07

8 Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. Do s & Don ts. General Follow the advice we have given you about where to safely store and use your liquid oxygen vessel. Use and store your liquid oxygen base unit upright. Use the portable flask in a position as demonstrated by our PSR. Periodical hissing from either the mother unit vessel or portable flask is normal and is how the system controls its pressure. Liquid oxygen installation requires a suitable ground floor area for storage - either a secure outdoor area, a well ventilated ground floor room or outbuilding free from any oils, paints, fuels etc. Filling Always ensure the filling connections on the portable flask and mother units are clean and dry before attempting to refill the portable flask using a dry cloth. When trans-filling the portable flask, never leave it unattended until the unit is full. If the unit will not disconnect easily, never use force to remove it. Wait a few moments to allow it to thaw and then try again. Should a minor leakage occur when the portable flask is disengaged, proceed to re-engage and then disengage the portable flask. This will help to dislodge any ice or other obstruction. If a leakage is still present, engage unit again and call us immediately. Should a major leakage occur (i.e. a stream of liquid oxygen is present) when the portable flask is disengaged, stay away from the flask, ventilate the area where safe to do so and call us immediately on 0800 136 603. Replace cap on mother unit vessel fill connector when not in use. Safety Never touch any cold parts on either vessel or allow liquid oxygen to come into contact with your skin, as this could cause a serious burn. If you do receive a cold burn, immerse the affected parts in tepid water. Close valve Keep flow control valve closed when the oxygen vessel is not in use.

Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. 9 Troubleshooting. Symptom Possible cause Solution No flow from portable flask. Flow does not seem sufficient. Wrong indication of liquid level. Leaks when connecting the units. Problem disconnecting units. Portable flask leaking after disconnecting. 1. Flow control set to off (0). 1. Set flow to correct setting. 2. Mother unit empty. 2. Check contents gauge. 3. Tubing not fitted correctly. 3. Check the fitting of the tubing. Check tubing is not kinked. 4. Blockage of tubing. 4. Contact us on 0800 136 603. 1. Leaks from tubing. 1. Refit tubing. 2. Incorrect setting. 2. Set flow control to prescribed flow rate. 1. Battery flat. 1. Contact us on 0800 136 603. 2. Failure of level indication system. 2. Contact us on 0800 136 603. Dirt on connecting faces or damaged Disconnect portable flask and clean connector. faces with a clean cloth, then refit. Ice on connecting faces. Ensure vent valve is closed and allow ice to melt NATURALLY. Clean and dry connecting faces with a clean cloth after removing unit. Ice in the fill valve or damaged connector. Major leaks Stay away from unit, open windows, contact us immediately on 0800 136 603. Minor leaks Reconnect portable flask to mother unit vessel with vent valve closed. Wait two minutes. Disconnect portable flask. If leak stops, clean and dry connecting faces with a clean cloth after unit is removed. If leak continues, reconnect the portable flask with vent valve closed. Contact us immediately on 0800 136 603.

10 Liquid Oxygen Mother Unit/Portable Flask System. Equipment Guide. Symptom Possible cause Solution Leak of water from portable flask. Leak of water from mother unit. Duration of use from portable flask shorter than usual. Any other problem or if problem persists. Felt pad on portable flask is saturated from condensation. On the Marathon portable flask, the felt pad can be located in the bottom of the back pack. Condensate receiver full. Portable flask not filled correctly. Please contact BOC Healthcare on 0800 136 603 Empty receiver and clean it before replacing. Please contact BOC Healthcare on 0800 136 603 if this cannot be located. Refill flask and check the level indicator indicates full. Contact us on 0800 136 603.

If you are visually impaired and require a large print copy, please contact us. Contact us. Our normal working hours are Monday to Friday 8am until 5.30pm. We are open 24 hours for emergencies only. BOC Healthcare Patient Service Centre, Priestley Road, Worsley, Manchester M28 2UT, United Kingdom Tel 0800 136 603, Fax 0800 169 9989, healthcare.home-uk@boc.com, www.bochealthcare.co.uk HLC/406735/1011 The stripe symbol and the letters BOC are registered trade marks of The BOC Group Limited. Both BOC Limited and The BOC Group Limited are members of The Linde Group, the parent company of which is Linde AG. Reproduction without permission is strictly prohibited. BOC Limited 2012