StainlessLite. Unvented mains pressure water storage in Duplex stainless steel

Similar documents
StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Electric Flow Boiler

Link-Up. Solid Fuel Association Guide to Central Heating.

Session 2: Hot Water Supply

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

UNDERSTANDING CENTRAL HEATING SYSTEMS

High Output Boiler Systems

Megaflo eco. Unvented hot water cylinders

Hot water supply, distribution and use

INSTALLATION INSTRUCTIONS FOR ALBION ULTRASTEEL UNVENTED CYLINDERS: DIRECT, INDIRECT AND SOLAR MODELS.

your water pressure explained

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

R e n e w a b l e s. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 14 May 2011 Part No.

HEAVY DUTY STORAGE GAS

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Torrent ECO. Design, Installation & Servicing Instructions. Open vented thermal store providing heating and mains pressure hot water

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Water Heating Catalogue

CI/SfB. (53.3) x. August Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Vaillant s plain English guide to. simple, concise and precise

Laddomat Charging unit

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

maximise the sun s energy with warmflow solar Warmflow Solar

Itho Products for Hot and Boiling water. product-

Guidance on how to comply with the 2010 Building Regulations Part L

Natural geothermal energy.

Solar Hot Water. What systems are available?

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Description of functions

Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation

ECOCIAT. Domestic hot water heat recovery unit

Solar Collector Series. Product List

Quantifying the energy and carbon effects of water saving summary report

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

Technical data. Danfoss DHP-A

Unvented water heater

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Get more from your hot water

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

building engineering services association specification for: Domestic Heating

ASME Packaged Indirect Fired Water Heater

BoilerMate SP. benchmark. user instructions A - C L A S S

Fully Pumped Systems

Building Services Engineering Technician

Baxi Combi 80e & 105e

Daikin Altherma Hybrid Heat Pump

Blowdown vessels Meeting the requirements of HSE PM60

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

Light Duty Commercial Electric Water Heater

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Gas Condensing Boilers

Stove-boiler for solid fuels KW Directions for use and assembling

Rainwater Harvesting

Delivering exceptional performance and Ecovalue. Ecocent

Daikin Altherma Hybrid Heat Pump

CE30. Domestic heating by gas: boiler systems guidance for installers and specifiers

Megalife Vented Cistern Fed Water Heater Installation manual

Ecodan Installation Manual

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC

Unvented water heater

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Operating instructions

Thermo Siphon Solar Systems

HOT WATER SYSTEMS.

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

SF15K SF05KSS, SF10KSS

HS-901(A) BASIC STEAM HEATING SYSTEMS

Continuous flow direct water heating for potable hot water

Module 2.2. Heat transfer mechanisms

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Domestic Chemical Water Treatment Manufacturers Association

Daikin Altherma Hybrid Heat Pump

Energy to the Power of

WARRANTY BOOKLET. Commercial Water Heaters. Register online at

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

CE29. Domestic heating by oil: boiler systems guidance for installers and specifiers

EcoSoft Water Softener. General Installation Guide

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

ECOplus Solar Cylinder

Operators manual Basic water heater

Air Source Heat Pump Installation and Maintenance Manual

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

1 DESCRIPTION OF THE APPLIANCE

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Energy Company Obligation (ECO): Technical Monitoring Questions

The energy you need. Clearly Hybrid. hybrid. Efficient Solutions. Heating. Hot Water.

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

ErP made easy What does it mean to merchants? What does it mean to installers?

Fall in love with your heating again. Reduce your heating bills with

SOLAR HOT WATER SOLUTIONS Ground Systems

ROTEX gas hybrid heat pump. A strong team.

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Water supply in tall buildings: roof tanks vs. pressurised systems

Commercial Semi-Instantaneous Water Heaters

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

Transcription:

StainlessLite Unvented mains pressure water storage in Duplex stainless steel S U P P L I E R S T O T H E M E R C H A N T T R A D E F O R O V E R 4 0 Y E A R S

StainlessLite Providing powerful, mains-pressure performance, it incorporates high flow rate controls, ideal for multi bathroom homes where baths fill very quickly. There are Indirect and Direct patterns for gas/oil and electricity with model sizes from 60 litres to 400 litres in each pattern with an additional eight options for solar energy. Duplex Stainless Steel The Stainless Lite uses the very latest high specification Duplex to resist all forms of corrosion including crevice and stress whilst its high mechanical strength gives it durability. The very latest automated welding procedures along with full post weld treatments guarantee welds that are as strong as the parent metal. Stainless Lite is pressure tested in the factory to a full 12 bar which is four times the normal working pressure. Corrugated Coil Stainless Lite uses a high heat transfer corrugated tube heat exchanger to give a 20% faster recovery than plain tube. It is also lighter and stronger than plain tube making the vessel the lightest and easiest to handle on site. Gledhill - The Cylinder Specialist The Gledhill name is synonymous with a family of water heating and storage products that lead the field in terms of innovation and quality. We are respected for our worldleading range of primary stores, but we have also produced unvented cylinders from the very beginning. Stainless Lite is an unvented mains pressure store in Duplex stainless steel that establishes new criteria for quality, performance and life. 2

storage vessels. The cylinders have been tested by NSF-WRc and WRAS, and found to comply with Building Regulations G3 and Water Regulations. In performance, it complies with the requirements of BS EN 806-1 to 5 and meets the NHBC criteria for domestic properties. Gledhill also operates a quality management system audited and accepted by the BSI in accordance with BS EN ISO 9001:2008. The Stainless Lite cylinders are supplied with all the quality fittings needed, according to model, including; Heat Loss All Gledhill Stainless Lite cylinders are manufactured using the very latest HCFC free EnviroFoam insulation. This has an Ozone Depletion Potential (ODP) of zero and an industry leading Global Warming Potential (GWP) of 0.7. Immersion heater(s) 2 port zone valve (indirect) Wiring centre (indirect) Dual thermostat (indirect) Inlet control set Tundish Benchmark log book Installation manual Expansion vessel kit including flexible connection hose Lift up pressure and temperature relief valve (unvented) Control thermostat and drain valve 90 degree elbow on hot draw off Tests show that the 50mm of EnviroFoam insulation injected into the case and covering both domes achieves astonishingly low levels of heat loss, which ensures it is fully compliant with 2010 Part L requirements for both new build and replacement cylinders. 25 Year Guarantee The 25 year guarantee underlines the usual Gledhill confidence in its own products. We regularly have copper cylinders returned to us that we made more than 40 years ago why should anyone expect less from stainless steel? Service Buying a good reputable product is critical but it must be available when needed. Gledhill has strategically located manufacturing units so that delivery can be made to a merchant anywhere within hours. Quality Standard - EN 12897 All Stainless Lite cylinders are manufactured in accordance with BS EN 12897 the specification for unvented water Our complete range of stainless steel cylinder options are explained in this brochure: Page 4 Page 6 Page 8 Stainless Lite Direct and Indirect Stainless Lite Solar Stainless Lite Slimline Direct, Indirect and Solar Page 10 Stainless Lite Horizontal Page 11 Stainless Lite Heat Pump Page 12 Stainless Lite Heat Pump Solar Page 14 Stainless Lite Slimline Heat Pump Page 15 Buffer Store Page 16 Flexible Buffer Store Page 17 Stainless Lite Triple Coil Page 18 Stainless Lite Vented 3

Direct and Indirect Unvented cylinders for use with a conventional boiler or electric power Gledhill Building Products manufacture 16 standard direct and indirect cylinders, ranging from 90 litres to 400 litres capacity. The Stainless Lite direct model is supplied with two immersions for off-peak and on-peak use (except 90 litre model which only has an on-peak immersion). Therefore, the store of water in the cylinder can be heated utilising the off-peak electricity, making the unit extremely efficient. These cylinders are ultimately lightweight, easy to install answer for electric hot water options. The immersion heater(s) must be connected to the supply through a double pole linked isolating switch with a minimum breaking capacity of 13A. All models have a temperature and pressure relief valve factory set at 6 bar and 92-95 C. The indirect range has a high efficiency corrugated tube coil which is connected to a conventional boiler to heat the cylinder of water. The coils corrugated design gives you much faster re-heat times than can be achieved with plain tube coils. All indirect models come with an on-peak immersion but only the 250, 300 and 400 litre models are supplied with an off-peak immersion. All tappings are within a 90 segment to make installation easier. 4

Stainless Lite Direct Technical Specification Description D90 D120 D150 D180 D210 D250 D300 D400 Height mm 745 930 1120 1305 1495 1745 1992 2030 Diameter mm 550 550 550 550 550 550 550 630 Weight (empty) kg 13 18 22 24 28 32 37 48 Weight (full) kg 103 138 172 204 238 282 337 448 Capacity litres 90 120 150 180 210 250 300 400 Pressure regulator bar 3 3 3 3 3 3 3 3 Expansion vessel size litres 12 12 18 18 24 24 35 2 x 24 kw rating of primary coil kw n/a n/a n/a n/a n/a n/a n/a n/a Recovery time after 70% draw off min 58 90 121 157 192 224 263 358/179 Standing losses kwhr/24hr 0.85 1.06 1.27 1.48 1.70 1.85 2.04 2.82 Stainless Lite Direct Model Selection Guide Maximum hot water demand Maximum number of bed spaces (bedrooms) Model 1 shower room Bedsit (0) D120 1 bathroom 2 (2) D150 1 bathroom 4 (3) D180 1 bathroom & separate shower room 6 (4) D210 1 bathroom & 2 separate shower rooms or 2 bathrooms 7 (5) D210 2 bathrooms & separate shower room 7 (5) D250 2 bathrooms & 2 separate shower rooms 7 (5) D300 3 bathrooms & 2 separate shower rooms 9 (6) D400 Stainless Lite Indirect Technical Specification Description IND90 IND120 IND150 IND180 IND210 IND250 IND300 IND400 Height mm 745 930 1120 1305 1495 1745 1992 2030 Diameter mm 550 550 550 550 550 550 550 630 Weight (empty) kg 19 22 26 28 33 38 44 55 Weight (full) kg 109 142 176 208 243 288 344 455 Capacity litres 90 120 150 180 210 250 300 400 Pressure regulator bar 3 3 3 3 3 3 3 3 Expansion vessel size litres 12 12 18 18 24 24 35 2 x 24 kw rating of primary coil kw 16.5 18.0 18.5 19.0 20.5 21.5 25.0 30.5 Recovery time after 70% draw off min 16 19 19 21 26 30 32 36 Standing losses kwhr/24hr 0.85 1.06 1.27 1.48 1.70 1.85 2.04 2.82 Stainless Lite Indirect Model Selection Guide Maximum hot water demand Maximum number of bed spaces (bedrooms) Model 1 shower room Bedsit (0) IND90 1 bathroom 2 (2) IND120 1 bathroom 4 (3) IND120 1 bathroom & separate shower room 6 (4) IND150 1 bathroom & 2 separate shower rooms or 2 bathrooms 7 (5) IND180 2 bathrooms & separate shower room 7 (5) IND210 2 bathrooms & 2 separate shower rooms 7 (5) IND250 3 bathrooms & 2 separate shower rooms 9 (6) IND300 3 bathrooms & 3 separate shower rooms 9 (6) IND400 Notes: 1 Recovery time is based on primary coil/immersion heater duty (ie. assumes the boiler output is adequate). 2 All connections are supplied with compression fittings for direct connection to copper pipework. 3 The heat up times shown for the D400 model indicate the times when 1 or 2 immersions are fitted. 4 The model sizes shown are based on a typical days hot water use assuming an Economy 7 tariff is provided. A reduction of one model size can normally be made with an Economy 10 tariff. 5 When using the Direct model for high specification developments, an increase of one model size should be considered. 5

StainlessLite Solar Unvented cylinders incorporating a solar coil Gledhill has developed a range of cylinders specifically for solar applications in mind, therefore providing an efficient way of providing domestic hot water. Each model features a dedicated high performance solar coil, transferring the maximum amount of heat from the solar circuit to the stored water. The cylinders are compatible with a wide range of solar systems available through the United Kingdom and have been designed to maximise the dedicated solar volume. The direct models are electrically heated cylinders, using the 3kW immersion heater supplied with the unit, with a high performance solar coil. They are capable of meeting the requirements of Building regulations, provided that it is matched to the panels and the hot water requirement correctly. The indirect cylinders are heated by a conventional boiler (either gas or oil) through a second high performance coil. The solar range is based on the standard Stainless Lite cylinders, therefore still providing you with mains pressure hot water, low standing heat losses and lightweight construction. The range of cylinders is suitable for properties from a bedsit to a 5 bedroom family home. Stainless Lite Direct Solar Technical Specification Description SOL180d SOL210d SOL250d SOL300d SOL400d Height mm 1305 1495 1745 1992 2030 Diameter mm 550 550 550 550 630 Weight (empty) kg 26 30 34 39 49 Weight (full) kg 206 240 284 339 449 Capacity litres 180 210 250 300 400 Pressure regulator bar 3 3 3 3 3 Expansion vessel size litres 18 24 24 35 2 x 24 kw rating of primary coil kw n/a n/a n/a n/a n/a Recovery time after 70% draw off min 90 115 139 187 260 Standing losses kwhr/24hr 1.48 1.70 1.85 2.04 2.82 Surface area of solar coil m 2 0.680 0.680 0.970 0.970 1.270 Dedicated solar volume litres 60 70 84 100 150 Maximum hot water demand Model Selection Guide Maximum solar panel area (m 2 ) Bedrooms 1 shower room 2.4 Bedsit SOL180d 1 bathroom 2.8 1-3 SOL210d 1 bathroom & separate shower room 3.36 1-3 SOL250d 1 bathroom & 2 separate shower rooms 4.0 2-4 SOL300d 2 bathrooms & separate shower room 6.0 4-5 SOL400d Notes: 1 Recovery time is based on primary coil/immersion heater duty (ie. assumes the boiler output is adequate). 2 All connections are supplied with compression fittings for direct connection to copper pipework. 3 The model sizes shown are based on a typical days hot water use assuming an Economy 7 tariff is provided. A reduction of one model size can normally be made with an Economy 10 tariff. 4 When using the Direct model for high specification developments, an increase of one model size should be considered. 5 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the solar panel to ensure compliance with Building Regulations. 6 Maximum solar panel area is calculated based on 25l/m 2 of net solar panel area. Model 6

Stainless Lite Indirect Solar Technical Specification Description SOL180i SOL210i SOL250i SOL300i SOL400i Height mm 1305 1495 1745 1992 2030 Diameter mm 550 550 550 550 630 Weight (empty) kg 30 35 40 46 59 Weight (full) kg 210 245 290 346 459 Capacity litres 180 210 250 300 400 Pressure regulator bar 3 3 3 3 3 Expansion vessel size litres 18 24 24 35 2 x 24 kw rating of primary coil kw 18.0 18.5 19.0 20.5 22.0 Recovery time after 70% draw off min 16 16 19 20 24 Standing losses kwhr/24hr 1.48 1.70 1.85 2.04 2.82 Surface area of solar coil m 2 0.680 0.680 0.970 0.970 1.270 Dedicated solar volume litres 96 101 107 125 165 Model Selection Guide Maximum hot water demand Maximum solar panel area (m 2 ) Bedrooms Model 1 bathroom 2.8 1-3 SOL180i 1 bathroom & separate shower room 3.6 1-3 SOL210i 1 bathroom & 2 separate shower rooms 4.8 2-4 SOL250i 2 bathrooms & separate shower room 5.0 3-4 SOL300i 2 bathrooms & 2 separate shower rooms 6.6 4-5 SOL400i Notes: 1 Recovery time is based on primary coil/immersion heater duty (ie. assumes the boiler output is adequate). 2 All connections are supplied with compression fittings for direct connection to copper pipework. 3 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the solar panel to ensure compliance with Building Regulations. 4 Maximum solar panel area is calculated based on 25l/m 2 of net solar panel area. 7

StainlessLite Slimline Unvented cylinders designed for restricted spaces with optional solar coil The new Stainless Lite Slimline cylinders have been added to our range of Duplex stainless steel cylinders, to enable you to utilise those smaller storage areas. The standard size Stainless Lite cylinders are 550mm in diameter but the new slimline range has a reduced diameter of 475mm.This now enables installers to fit the new cylinders into smaller properties or older homes where there are space limitations, and so provide the benefits of mains pressure hot water. The new range of Stainless Lite Slimline cylinders come in sizes from 60 litres to 210 litres in both indirect and direct versions. In addition, it also comes with a solar option in 180 litre and 210 litre sizes. This now means there will be a model to suit most homes. The introduction of the Slimline solar range enables homeowners to not only upgrade to a Duplex stainless steel cylinder, but also have the added benefit of being able to utilise solar power to contribute to the heating of the store. Properties that previously could not enjoy mains pressure hot water can now enjoy powerful, mains-pressure performance, incorporating high flow rate controls, ideal for multi bathroom homes, where baths fill very quickly. You will still benefit from the high heat transfer corrugated tube giving 20% faster recovery than plain tubing, controlled stratification and minimal heat loss. All slimline models (except 60 and 90 litre direct options) come complete with an on-peak immersion. All direct models have an off-peak immersion. 75mm slimmer than a standard unit 8

Stainless Lite Direct Slimline and Solar Technical Specification Description D60-SL D90-SL D120-SL D150-SL D180-SL D210-SL SOL 180d-SL SOL 210d-SL Height mm 705 978 1250 1520 1790 1970 1790 1970 Diameter mm 475 475 475 475 475 475 475 475 Weight (empty) kg 13 16 22 30 31 32 32 36 Weight (full) kg 73 106 142 180 211 242 212 246 Capacity litres 60 90 120 150 180 210 180 210 Pressure regulator bar 3 3 3 3 3 3 3 3 Expansion vessel size litres 12 12 12 18 18 24 18 24 kw rating of primary coil kw n/a n/a n/a n/a n/a n/a n/a n/a Recovery time after 70% draw off min 39 58 90 121 157 192 90 115 Standing losses kwhr/24hr 0.95 1.25 1.52 1.77 2.01 2.23 2.01 2.23 Surface area of solar coil m 2 n/a n/a n/a n/s n/a n/a 0.680 0.680 Dedicated solar volume litres n/a n/a n/a n/a n/a n/a 60 70 Stainless Lite Indirect Slimline and Solar Technical Specification Description IND60-SL IND90-SL IND120-SL IND150-SL IND180-SL IND210-SL SOL 180i-SL SOL 210i-SL Height mm 705 978 1250 1520 1790 1970 1790 1970 Diameter mm 475 475 475 475 475 475 475 475 Weight (empty) kg 14 19 23 28 31 34 33 37 Weight (full) kg 74 109 143 178 211 244 213 247 Capacity litres 60 90 120 150 180 210 180 210 Pressure regulator bar 3 3 3 3 3 3 3 3 Expansion vessel size litres 12 12 12 18 18 24 18 24 kw rating of primary coil kw 15.0 16.5 18.0 18.5 19.0 20.5 18.0 18.5 Recovery time after 70% draw off min 11 16 19 19 21 26 16 16 Standing losses kwhr/24hr 0.95 1.25 1.52 1.77 2.01 2.23 2.01 2.23 Surface area of solar coil m 2 n/a n/a n/a n/s n/a n/a 0.680 0.680 Dedicated solar volume litres n/a n/a n/a n/a n/a n/a 60 70 Model Selection Guide Maximum hot water demand Maximum number of bed spaces (bedrooms) Direct Model Indirect Model 1 shower room Bedsit (0) D120-SL IND90-SL 1 bathroom 2 (2) D150-SL IND120-SL 1 bathroom 4 (3) D180-SL IND120-SL 1 bathroom & separate shower room 6 (4) D210-SL IND150-SL 1 bathroom & 2 separate shower rooms or 2 bathrooms 7 (5) D210-SL IND180-SL 2 bathrooms & separate shower room 7 (5) - IND210-SL Solar Model Selection Guide Maximum hot water demand Maximum solar panel area (m 2 ) Bedrooms Direct Model Indirect Model 1 shower room 2.4 Bedsit SOL180d-SL - 1 bathroom 2.4 1-3 - SOL180i-SL 1 bathroom 2.8 1-3 SOL210d-SL - 1 bathroom & separate shower room 2.8 1-3 - SOL210i-SL Notes: 1 Recovery time is based on primary coil/immersion heater duty (ie. assumes the boiler output is adequate). 2 All connections are supplied with compression fittings for direct connection to copper pipework. 3 The Direct model sizes shown are based on a typical days hot water use assuming an Economy 7 tariff is provided. A reduction of one model size can normally be made with an Economy 10 tariff. 4 When using the Direct model for high specification developments, an increase of one model size should be considered. 5 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the solar panel to ensure compliance with Building Regulations. 6 Maximum solar panel area is calculated based on 25l/m 2 of net solar panel area. 9

Horizontal Option StainlessLite horizontal unvented cylinders with a solar option available We have achieved yet another market first with the launch of the UK s only domestic horizontal unvented cylinder. This has been independently approved by public health and safety organisation, NSF-WRc, to meet the legal requirements of Building Regulations With another new addition to Gledhill s market leading family of StainlessLite cylinders, the new range of horizontal products are available in sizes from 180 litres to 300 litres in both indirect and indirect solar configurations. Providing the ideal solution for locations where installation height is restricted, Gledhill s StainlessLite range is up to 50 per cent lighter than other unvented stainless steel cylinders, making the product perfectly suited to loft spaces. NSF-WRC APPROVED P RO D U CT Stainless Lite Horizontal Indirect and Solar Technical Specification Description IND180 IND210 IND250 IND300 IND180 SOL IND210 SOL IND250 SOL Overall Height mm 585 585 585 585 585 585 585 585 Overall Width mm 1310 1495 1745 1992 1310 1495 1745 1992 Diameter mm 550 550 550 550 550 550 550 550 Weight (empty) kg 27 31 35 46 34 34 35 46 Weight (full) kg 203 238 281 342 205 242 279 340 Capacity litres 176 207 246 296 174 208 244 294 Pressure regulator bar 3 3 3 3 3 3 3 3 Expansion vessel size litres 18 24 24 35 18 24 24 35 kw rating of primary coil kw 18.4 20.9 20.3 21.6 15.4 16.0 20.2 17.7 Recovery time after 70% draw off min 27 26 26 28 21 23 36 26 Standing losses kwhr/24hr 1.88 1.96 2.06 2.18 1.88 1.96 2.06 2.18 Surface area of solar coil m 2 n/a n/a n/a n/a 0.49 0.49 0.59 0.59 Dedicated solar volume litres n/a n/a n/a n/a 64 85 112 145 IND300 SOL Notes: 1 Recovery time is based on primary coil/immersion heater duty (ie. assumes the boiler output is adequate). 2 All connections are supplied with compression fittings for direct connection to copper pipework. 3 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the solar panel to ensure compliance with Building Regulations. 4 Maximum solar panel area is calculated based on 25l/m 2 of net solar panel area. 10

StainlessLite HP Stainless steel unvented cylinder designed for use with heat pumps Gledhill have expanded its range of unvented stainless steel units specifically for heat pump applications by developing a model with an increased size heat exchanger to maximise the lower temperatures available from the heat pump. The heat exchanger is a new design, and has been increased up to 4 square metres in the largest units, maximising the heat exchange. Due to the fact that many heat pumps will not raise the stored water temperature to 60 C, which is necessary to prevent the growth of legionella, the Stainless Lite HP model is supplied with an immersion heater and a thermostat. It is recommended that a thermostat is fitted which brings the immersion heater on at a temperature just below the heat pump maximum and switches off at 60 C or 65 C. Stainless Lite HP Technical Specification Description HP180IND HP210IND HP250IND HP300IND HP400IND Height mm 1305 1495 1745 1992 2030 Diameter mm 550 550 550 550 630 Weight (empty) kg 33 38 43 58 62 Weight (full) kg 204 250 294 350 452 Capacity litres 171 212 251 292 390 Pressure regulator bar 3 3 3 3 3 Expansion vessel size litres 18 24 24 35 2 X 24 kw rating of heat pump coil kw 16.74 17.91 15.93 13.18 18.87 Heat pump coil pressure loss bar 0.04 0.05 0.06 0.05 0.07 Surface area of heat pump coil m 2 2.5 3 3 3 4 Standing losses kwhr/24hr 1.48 1.70 1.85 2.04 2.82 Model Selection Guide Maximum hot water demand Bedrooms Model 1 bathroom 1-3 HP180IND 1 bathroom & separate shower room 2-3 HP180IND 1 bathroom & 2 separate shower rooms 2-3 HP180IND 2 bathrooms & separate shower room 2-4 HP210IND 2 bathrooms & 2 separate shower rooms 2-4 HP250IND 2 bathrooms & 2 separate shower rooms 3-5 HP300IND 2 bathrooms & 3 separate shower rooms 4-5 HP400IND Notes: 1 All connections are supplied with compression fittings for direct connection to copper pipework. 2 The suggested model sizes shown are based on a typical days hot water use assuming that the heat pump will heat the domestic hot water to approximately 50 C. 3 Heat pump kw rating performed at 80 C and 0.25 l/s. 11

StainlessLite HP SOL Unvented cylinders designed for use with heat pump and solar technology Gledhill have produced an unvented stainless steel unit specifically for heat pump applications providing mains pressure domestic hot water. Utilising the well established Gledhill Stainless Lite unvented hot water cylinder, this product has been developed to maximise the lower temperatures available from the heat pump. The heat exchanger is a totally new design. It consists of a multi-pass corrugated stainless steel tube in parallel to reduce the pressure loss whilst maximising the heat exchange. Many medium to large heat pumps need heat exchangers in the store that will cope with the higher flow rates associated with primary temperatures that are typically 50 C or 60 C. All the usual features of the Gledhill Stainless Lite are maintained together with all the necessary controls and expansion devices included. Due to the fact that many heat pumps will not raise the stored water temperature to 60 C, which is necessary to prevent the growth of legionella, the Stainless Lite HP model is supplied with an immersion heater and a thermostat. It is recommended that a thermostat is fitted which brings the immersion heater on at a temperature just below the heat pump maximum and switches off at 60 C or 65 C. In this way the use of direct electricity is minimised and most of the water heating is achieved through the heat pump. The key features of the Stainless Lite HP SOL are: The latest and highest quality Duplex Stainless Steel. A 25 year guarantee. Fast reheat rate from its purpose designed low resistance coil. One of the highest insulation ratings on offer today. The Stainless Lite HP SOL is supplied with all the necessary connections including two dry thermostat pockets. 12

Stainless Lite HP SOL system (with optional solar panels) for use on a sealed heating system. PRV Expansion vessel Central heating zone valve Solar pumping station Hot water zone valve System pump Primary circuit sealed system kit Heat pump PRV Solar circuit zone valve Central heating flow and return Stainless Lite HP SOL Technical Specification Description HP180INDSOL HP210INDSOL HP250INDSOL HP300INDSOL HP400INDSOL Height mm 1305 1495 1745 1992 2030 Diameter mm 550 550 550 550 630 Weight (empty) kg 33 38 43 49 61 Weight (full) kg 213 248 293 349 461 Capacity litres 180 210 250 300 400 Pressure regulator bar 3 3 3 3 3 Expansion vessel size litres 18 24 24 35 2 X 24 kw rating of heat pump coil kw 24.3 26.2 27.5 34.2 47.2 Heat pump coil pressure loss bar 0.048 0.054 0.060 0.019 0.027 Surface area of heat pump coil m 2 1.36 1.56 1.94 2.04 2.91 Standing losses kwhr/24hr 1.48 1.70 1.85 2.04 2.82 Surface area of solar coil m 2 0.680 0.680 0.970 0.970 1.270 Dedicated solar volume litres 65 75 90 105 130 Model Selection Guide Maximum hot water demand Maximum solar Model (without Model (with solar Bedrooms panel area (m 2 ) solar heating input) heating input) 1 bathroom 2.6 1-3 HP180INDSOL HP180INDSOL 1 bathroom & separate shower room 3.0 2-3 HP180INDSOL HP210INDSOL 1 bathroom & 2 separate shower rooms 3.6 2-3 HP180INDSOL HP250INDSOL 2 bathrooms & separate shower room 4.2 2-4 HP210INDSOL HP300INDSOL 2 bathrooms & 2 separate shower rooms 5.2 2-4 HP250INDSOL HP400INDSOL 2 bathrooms & 2 separate shower rooms - 3-5 HP300INDSOL - 2 bathrooms & 3 separate shower rooms - 4-5 HP400INDSOL - Notes: 1 All connections are supplied with compression fittings for direct connection to copper pipework. 2 The suggested model sizes shown are based on a typical days hot water use assuming that the heat pump will heat the domestic hot water to approximately 50 C. 3 When connecting to solar heating input, it is important to check the dedicated solar volume is suitable for the total floor area to comply with Building Regulations. 4 The Stainless Lite HP units are the same whether you are running solar thermal systems in conjunction with heat pump or just using a heat pump input only. 5 The solar dedicated volume is only applicable when used in conjunction with solar thermal systems. 6 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the solar panel to ensure compliance with Building Regulations. 7 Maximum solar panel area is calculated based on 25 l/m 2 of net solar panel area. 8 Heat pump kw rating performed at 80 C and 0.25 l/s. 13

Slimline Heat Pump Stainless steel unvented heat pump cylinders designed for restricted spaces In situations where you want to upgrade a standard cylinder with a heat pump installation, you will constantly come up against the problem of installing a standard diameter unit into a small cupboard space, common in older properties. As a result, in addition to our existing Stainless Lite standard heat pump range, we have developed the new Stainless Lite Slimline HP which has a reduced diameter of 475mm.This now enables installers to fit the new cylinders into smaller properties or older homes where there are space limitations, and so provide the benefits of mains pressure hot water. specifically designed for maximum heat transfer. The heat exchanger is a totally new design. It consists of a multipass corrugated stainless steel tube in parallel to reduce the pressure loss whilst maximising the heat exchange and ensuring high flow rates essential to work with heat pumps. Due to the fact that many heat pumps will not raise the stored water temperature to 60 C, which is necessary to prevent the growth of legionella, the Stainless Lite Slimline HP model is supplied with an immersion heater and a thermostat. The new range of Stainless Lite Slimline HP cylinders come in 180 litres and 210 litres sizes. Utilising the well established Gledhill Stainless Lite unvented hot water cylinder, this product has been developed to maximise lower temperatures available from the heat pump. Although the cylinder has a reduced diameter, it still has a 3m 2 high performance corrugated coil which has been It is recommended that a thermostat is fitted which brings the immersion heater on at a temperature just below the heat pump maximum and switches off at 60 C or 65 C. In this way the use of direct electricity is minimised and most of the water heating is achieved through the heat pump. As with all our Stainless Lite cylinders, they are insulated with 100% recyclable foam, which provides one of the lowest standing heat losses on the market to aid SAP. Stainless Lite Slimline HP Technical Specification Description HP180SL HP210SL Height mm 1790 1970 Diameter mm 475 475 Weight (empty) kg 33 37 Weight (full) kg 213 247 Capacity litres 180 210 Pressure regulator bar 3 3 Expansion vessel size litres 18 24 kw rating of heat pump coil kw 32.8 31.2 Heat pump coil pressure loss bar 0.018 0.018 Surface area of heat pump coil m 2 3.01 3.01 Standing losses kwhr/24hr 2.01 2.23 Model Selection Guide Maximum hot water demand Bedrooms Model 1 bathroom 1-3 HP180SL 1 bathroom & separate shower room 2-3 HP180SL 1 bathroom & 2 separate shower rooms 2-3 HP180SL 2 bathrooms & separate shower room 2-4 HP210SL Notes: 1 All connections are supplied with compression fittings for direct connection to copper pipework. 2 The suggested model sizes shown are based on a typical days hot water use assuming that the heat pump will heat the domestic hot water to approximately 50 C. 3 Heat pump kw rating performed at 80 C and 0.25 l/s. 14

Buffer Store Vented store for use with heat pump systems Buffer vessels are simply a duplex stainless steel tank that contains a volume of water, increasing the overall volume of the heating distribution system. This extra volume of water is designed to absorb any extra heat generated by the heat pump in low load conditions. If the building cannot absorb the extra heat generated the return temperature to the heat pump will increase and will potentially cause the heat pump to turn off. If the temperature drops in the water returning to the heating appliance, then it will turn itself back on. If this cycling occurs at a greater frequency than the minimum run time for the appliance, this is classed as short cycling. The aim of a buffer vessel is to remove the possibility of any short cycling of the heating appliance. These buffer vessels are designed to work at up to 3.5 bar pressure for primary water only. They should not be used for potable domestic hot water and are not approved for this purpose. Stainless Lite Direct Buffer Store Technical Specification Description 90D 120D 210D 300D 400D Height mm 745 930 1495 1992 2030 Diameter mm 550 550 550 550 630 Weight (empty) kg 13 18 28 37 51 Weight (full) kg 103 138 238 337 451 Capacity litres 90 120 210 300 400 Standing losses kwhr/24hr 0.85 1.06 1.70 2.04 2.82 Stainless Lite Indirect Buffer Store Technical Specification Description 120IND 210IND 300IND 400IND Height mm 930 1495 1992 2030 Diameter mm 550 550 550 630 Weight (empty) kg 22 33 44 55 Weight (full) kg 142 243 344 455 Capacity litres 120 210 300 400 Standing losses kwhr/24hr 1.06 1.70 2.04 2.82 15

Flexible Buffer Store Vented store for use with multiple heat pumps or additional heat sources The Buffer Store range has been extended providing multiple connections. This not overcomes the issue of connecting multiple heat pump units to a single store, but you are now also able to connect a wood burning stove and open vented gas boiler (subject to correct controls being installed), making the Flexible Buffer Store the perfect solution. This allows you to utilise multiple heat sources to boost the temperature of the water within the store initially generated by the heat pumps. In addition to the multiple inputs, the Flexible Buffer Store also allows installers to connect a heating circuit to the cylinder to provide heating to the property. High Level Stat 22mm Compression Upper Plain Pipe Connections Inspection Hatch Low Level Stat Lower Plain Pipe Connections ½" BSP Fitting for Drain Valve These buffer vessels are designed to work at up to 3.5 bar pressure for primary water only. They should not be used for potable domestic hot water and are not approved for this purpose. Stainless Lite Flexible Buffer Store Technical Specification Description 90FLX 120FLX 210FLX 250FLX 300FLX 400FLX Capacity litres 90 120 210 250 300 400 Height mm 745 930 1495 1745 1992 2030 Diameter mm 550 550 550 550 550 630 Weight (empty) kg 13 18 28 32 37 51 Weight (full) kg 103 138 238 282 337 451 Standing losses kwhr/24hr 0.85 1.06 1.70 1.85 2.04 2.82 Maximum working pressure - cylinder bar 3.5 3.5 3.5 3.5 3.5 3.5 Maximum working pressure - space heating bar 3.5 3.5 3.5 3.5 3.5 3.5 Tappings mm 28 28 35 35 35 35 16

StainlessLite Triple Coil Open vented cylinders for use with multiple heat sources To satisfy the growing demand for a stainless steel cylinder being capable of accepting multiple heat sources, Gledhill has developed a triple coil version of the Stainless Lite cylinder, which can accept solar and uncontrolled heat sources such as solid fuel or wood burning appliances. The cylinder has a dedicated solar coil at the bottom of the cylinder. It then has a double coil for the solid fuel heat supply and a single coil for the gas/oil boiler. It also has a back up heat source in the form of an immersion heater. The three separate coils will work independently providing the maximum heat to the store, and subsequently reduce the households fuel bills. The boiler coil and solar coil are both 22mm and the solid fuel gravity circulation are 28mm. Stainless Lite Triple Coil Technical Specification Description IND300-STC IND400-STC Height mm 1992 2030 Diameter mm 550 630 Weight (empty) kg 46 60 Weight (full) kg 346 460 Capacity litres 300 400 kw rating of primary coil kw 20.5 20.5 Recovery time after 70% draw off min 41 45 Standing losses kwhr/24hr 2.04 2.82 Surface area of solar coil m 2 0.97 1.27 Dedicated solar volume litres 100 150 Maximum solar panel area m 2 4.0 6.0 Notes: 1 Recovery time is based on primary coil/immersion heater duty (ie. assumes the boiler output is adequate). 2 All connections are supplied with compression fittings for direct connection to copper pipework. 3 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the solar panel to ensure compliance with Building Regulations. 4 Maximum solar panel area is calculated based on 25l/m 2 of net solar panel area. 17

StainlessLite Vented Unvented cylinders converted for use with uncontrolled heat sources The only difference between the vented and unvented range of Stainless Lite cylinders is that instead of being supplied with the unvented kit, the vented option is supplied with a control thermostat and a drain valve. The technical and dimensional data for the Stainless Lite vented is the same as the Stainless Lite and Stainless Lite Solar, both of which are available in direct and indirect configurations. Full technical details can be found on pages 5-8 in this brochure. The Stainless Lite vented option provides a high quality open vented stainless steel cylinder for use in a traditional vented cylinder installation. As an open vented cylinder, it also permits the connection of an uncontrolled heat source such as a solid fuel or wood burning appliance, which is not permitted with an unvented cylinder. Please note when using in this application, a fully pumped system will be required. The traditional vented storage water heater has a proven track record of reliability and safety. The operating pressure is dictated by the vertical distance between the cistern tank and the bottom of the heater. The open vented system is renowned for its safety because the open vent that discharges in to the cistern tank automatically equalises any excess pressure or vacuum. The Stainless Lite vented cylinder is fully compliant with 2010 Part L regulations, therefore it now enables you to fit a vented cylinder into a new build property. 18

Up against time to replace that cylinder? The required model is not stocked at the merchant? Then the obvious choice has to be the complete cylinder service Ordering your urgently required unvented cylinder couldn t be simpler; Place your order at the merchant Order is sent to one of our nationwide depots where the core range of cylinders stocked Same day collection available from the local depot* Next day delivery to any mainland UK address at no extra cost** * The same day collection service is subject to orders before 1pm ** Not applicable to all postcode regions in Scotland, please speak to Inverkeithing depot for further details PLACE YOUR ORDER STOCKED LOCALLY DELIVERED NEXT DAY 19

UK Super Depot Infrastructure Blackpool Head Office and Stainless Steel Manufacturing Site Nottingham Telephone: 01773 580684 Fax: 01773 581129 Blackburn Telephone: 01254 693844 Fax: 01254 673615 Bristol Telephone: 01179 820814 Fax: 01179 820821 Inverkeithing Telephone: 01383 414133 Fax: 01383 413123 Luton Telephone: 01582 728253 Fax: 01582 318976 Maidstone Telephone: 01622 714770 Fax: 01622 882286 Oldbury Telephone: 01384 636245 Fax: 01384 413700 Paignton Telephone: 01803 557470 Fax: 01803 559213 Southampton Telephone: 01329 846601 Fax: 01329 845881 For technical advice please call 01253 474584 SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS Gledhill Building Products Limited Sycamore Estate, Squires Gate, Blackpool FY4 3RL Tel: 01253 474550 Fax: 01253 474551 sales@gledhill.net Gledhill Building Products produce cylinders for use with a wide range of heat sources including; Gas and oil boilers Electricity Air source heat pumps Ground source heat pumps Solar energy Wood burning stoves Further information on Gledhill products can be found on the internet at www.gledhill.net Only the best is acceptable FM 02057 Due to a programme of continuous improvement Gledhill Building Products reserve the right to modify products without prior notice. It is advisable to check the product technical detail by using the latest design and installation manuals available from our technical support team or on our website. It is an offence to copy or adapt this document without consent of the owner. Spec 103/08 07/14