Corning Spheroid Microplates

Similar documents
Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

ADP/ATP Ratio Assay Kit (Bioluminescent)

Radius 24-Well Cell Migration Assay (Laminin Coated)

Corning Microplate Selection Guide. For Assays and Drug Discovery

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

INTERFERin in vitro sirna/mirna transfection reagent PROTOCOL. 1 Standard sirna transfection of adherent cells... 2

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

Cell Migration, Chemotaxis and Invasion Assay Protocol

BioResearch. RAFT 3D Cell Culture Kit Protocol

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

AxyPrep TM Mag PCR Clean-up Protocol

Proto col. GoClone Repor ter Construc ts: Sample Protocol for Adherent Cells. Tech support: Luciferase Assay System

PRODUCT INFORMATION...

ab Protein Sumoylation Assay Ultra Kit

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Corning Microplates Product Selection Guide. For Assays and Drug Discovery

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

full library phenotypic screening without compromise

Thermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples

Empower 3D cell culture with simplicity and versatility. VitroGel TM 3D. a ready-to-use hydrogel system for 3D cell culture and beyond

T100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover

Human Adult Mesothelial Cell Manual

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

Classic Immunoprecipitation

Mesenchymal Stem Cells

Application Note. Single Cell PCR Preparation

Creatine Kinase Activity Assay Kit (Colorimetric)

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

CellTiter-Fluor Cell Viability Assay

Modulating Glucose Uptake in Skeletal Myotubes:

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

HBV Quantitative Real Time PCR Kit

CFSE Cell Division Assay Kit

Featuring fast rotor exchanges with AUTO-LOCK

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

GASTRIC ORGANOID CULTURE PROTOCOL

How To Get Rid Of Small Dna Fragments

ArC Amine Reactive Compensation Bead Kit

Uscn Life Science Inc. Wuhan

Effective Methods For Culturing Breast Cancer Cell Lines

Keysight Technologies How to Choose your MAC Lever. Technical Overview

Optimized Protocol sirna Test Kit for Cell Lines and Adherent Primary Cells

ProteinChip Energy Absorbing Molecules (EAM)

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Steatosis Colorimetric Assay Kit

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

Follicle Dermal Papilla Cell

Annexin V-EGFP Apoptosis Detection Kit

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

Cell Cycle Phase Determination Kit

Malondialdehyde (MDA) ELISA

Automating Cell Biology Annual general meeting, September 7, Phase Holographic Imaging

MTT Cell Proliferation Assay

Islet Viability Assessment by Single Cell Flow Cytometry

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

BD PuraMatrix Peptide Hydrogel

Equipment. Reagent reconstitution and storage

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

Effects of Antibiotics on Bacterial Growth and Protein Synthesis: Student Laboratory Manual

Annexin V-FITC Apoptosis Detection Kit

LightSwitch Dual Assay System DA010 (100 assays)

Maxwell 16 Blood DNA Purification System

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Barcode Labeling in the Lab Closing the Loop of Patient Safety

Human Free Testosterone(F-TESTO) ELISA Kit

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Glycolysis Cell-Based Assay Kit

CytoSelect 48-Well Cell Adhesion Assay (ECM Array, Fluorometric Format)

Automation of Cell Staining Technical Information Bulletin

Data Sheet. PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

Mouse ES Cell Nucleofector Kit

Fast, easy and effective transfection reagent for mammalian cells

Corning Cell Culture Selection Guide. Life Sciences

Application Note No. 2 / July Quantitative Assessment of Cell Quality, Viability and Proliferation. System

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

Annexin V-FITC Apoptosis Detection Kit

Cell Culture Protocol for Biogelx Peptide Hydrogel 2D and 3D Cell Culture PRO/BGX/001

ab83369 Alkaline Phosphatase Assay kit (Colorimetric)

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

Creatine Kinase Activity Colorimetric Assay Kit ABE assays; Store at -20 C

BR-10150B. Bringing power and flexibility down to size. BIOMEK NX LABORATORY AUTOMATION WORKSTATION

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

LAB 24 Transpiration

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.

QuickZyme Soluble Collagen Assay

Overview of 3D Cell Culture Model Systems & Validating Cell-based Assays for Use with 3D Cultures Terry Riss, PhD March 2014

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

ncounter Gene Expression Assay Manual Total RNA and Cell Lysate Protocols

CypExpress 3A4 Catalyzed Conversion of Testosterone (TE) to 6β- Hydroxytestosterone (HT)

CytoSelect Cell Viability and Cytotoxicity Assay Kit

IncuCyte ZOOM Whole Well Imaging Overview

Corning Cell Culture Selection Guide

HARVESTING AND CRYOPRESERVATION OF HUMAN EMBRYONIC STEM CELLS (hescs)

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Transcription:

Corning Spheroid Microplates User Guide In vitro 3D cell culture models are widely recognized as more physiologically relevant systems compared to 2D formats. The 3D models reflect more accurately the complex in vivo microenvironment and have been used in many research areas, such as cancer biology 1, hepatotoxicity 2, neurology 3, pancreatic studies 4, nephrology 5, and stem cell biology 6. These studies have revolutionized our understanding of cellular behavior both in culture and in vivo. However, adoption of 3D cell culture models in high throughput screening (HTS) platforms has been slow due to the limitations of the current technologies. Problems include increased variability, low throughput, difficulty to automate, and high cost 1. Corning spheroid microplates are multiple well, cell culture plates with opaque walls and clear, round well-bottom geometry. The proprietary Corning Ultra-Low Attachment surface coating, which is hydrophilic, biologically inert and non-degradable, is covalently attached to the interior surface of the well-bottom. The unique design of the well-bottom enables highly reproducible growth of 3D cell spheroid cultures. The opaque side walls and proprietary gridded plate bottom design reduce well-towell cross-talk and background fluorescence/luminescence. Spheroids may be generated, cultured, and assayed for fluorescent or luminescent signals in the same plate without the need for transferring the spheroids. Currently, Corning spheroid microplates are available in both 96-well (Corning Cat. Nos. 4520 and 4515) and 384-well (Corning Cat. Nos. 3830 and 4516) formats. Both formats are automation friendly. The protocol below describes a basic method for generating and culturing multicellular spheroids. Plating volumes and densities are cell line and downstream application dependent, therefore assay specific optimization of conditions is recommended. Setting Up Cell Cultures Initial plating densities for spheroid formation depend on factors such as cell-type, duration of growth phase in a spheroidal format and the desired size of spheroid at the time of assessment. Depending on the cell lines to be cultured and downstream processes, starting volumes can range from 75 to 200 µl per well (maximum working volume: 300 µl) for the 96-well format and 25 to 75 µl per well (maximum working volume: 90 µl) for the 384-well format. 1. Prepare single cell suspension at the desired seeding concentration; cells can come from fresh cultures or from frozen vials. Note: If necessary to achieve a single cell suspension, cells can be passed through a 40 µm cell strainer (Corning Cat. No. 431750) or a 5 ml round bottom, polystyrene tube, with cell strainer snap cap (Corning Cat. No. 352235). 2. Dispense cell suspension into wells. This step can be achieved by using either manual multichannel pipettor or automated dispensing systems. Note: During manual seed, ensure pipet tips do not scratch the bottom or sides of the wells to avoid damaging the Ultra-Low Attachment surface coating. 3. Following dispensing, the plates can be covered then transferred to incubation step. (Set humidified incubator to 37 C and 5% CO 2 for most mammalian cultures). Note: Most cell lines will form spheroids within a 24-hour period. Some cell lines may require a 15-minute incubation post-seed or a quick pulse spin in a centrifuge in order to help cells congregate faster. Optimization of the protocol is recommended.

4. Daily monitoring of spheroid formation and growth can be easily done using any microscope. 5. Depending on the cell line and the duration of growth phase in a spheroidal format, a re-feeding step may be necessary. Spheroids can be fed by adding fresh media to wells or by removing spent media and dispensing fresh media into the wells. a. Aspiration and addition of media can be done manually or using an automated liquid handling system. b. In order to leave spheroids undisturbed during media changes, sides of wells should be used to remove and add media. c. It is recommended that 10 to 20 µl volume be left in the well during media change. 6. Assay/process spheroids in microplate following recommended assay steps, no transfer step required. Examples of Multicellular Spheroids in Corning Spheroid Microplates Uniform, single mulicellular spheroids (MCS) generated per well. DU 145 Spheroids in a 96-well Corning Spheroid Microplate 40 cells/well 200 cells/well 1,000 cells/well 5,000 cells/well 10,000 cells/well 24 hr 72-hour Spheroid Cultures DU 145 Spheroids HCT-116 48 hr HeLa 72 hr Hep-G2, HeLa, and HCT-116 Spheroids in a 384-well Corning Spheroid Microplate 2,500 cells/well 5,000 cells/well Hep-G2 10,000 cells/well 20,000 cells/well Scale bar = 1,000 µm 2

Examples of Assay Using Corning Spheroid Microplates Cell proliferation and cytotoxicity assay screening using CellTiter-Glo 3D Cell Viability Assay (Promega Cat. No. G9683). Tumor invasion assay using Cytation Cell Imaging Multi-Mode Reader and Gen5 Data Analysis Software (BioTek Instruments, Inc.) DU 145 spheroid dose response to Doxorubicin over a 72-hour treatment in a 384-well Corning spheroid microplate. MDA-MB-231/Fibroblast tumor invasion in a 96-well Corning spheroid microplate imaged using the Cytation Cell Imaging Multi-Mode microplate reader. Image reprinted, courtesy of BioTek Instruments, Inc. Fluorescence microscopy using LIVE/DEAD Viability/Cytotoxicity Kit (Life Technologies, Cat. No. L3224). 30 min 1 hr 6 hr 24 hr 48 hr 80 hr Within the hour, cells form a loose aggregate. Cells pool into a more defined aggregate. Tight spheroid with defined edges. Center of spheroid shows initial signs of necrosis. HT-29 spheroid formation over a 3-day period in a 96-well Corning spheroid microplate. Dimensions to Support Instrumentation Setup Cat. No. 96-well 4520 and 4515 384-well 3830 and 4516 Volume (µl) Depth Diameter (top/bottom) Length Width A1 Row Offset A1 Column Offset Center to Center Spacing Flange or Skirt Stack Elevation Thickness 300 12.36 6.85/6.35 127.6 85.5 14.2 11.2 14.27 9 6.096 13.12 1.86 0.0875 1.86 90 12.54 3.63/2.82 127.6 85.5 14.2 8.99 12.13 4.5 2.41 12.95 1.81 0.0875 1.81 Distance to of 3

Corning Spheroid Microplate FAQ Q: How many spheroids are generated per well? A: The Corning spheroid microplate was designed to generate single, uniform sized spheroids in every well. Q: How do I control the size of the spheroids? A: By altering the initial seeding density, the diameter of the spheroids in the culture can be controlled. Q: Are there any special storage conditions? A: No. The Corning Ultra-Low Attachment surface is a stable, noncytotoxic, nondegradable, biologically inert hydrogel coating that requires no special storage or handling conditions. Q: What is the advantage of using a round bottom vs. a flat bottom microplate for forming spheroids? A: The unique round well bottom design of the Corning spheroid microplate generates single, uniform spheroids, that are centered in each well. This technology is a reliable tool for 3D screening. Flat bottom wells generate multiple, non-uniform sized spheroids that are not evenly distributed and lack reproducibility across wells. Because of the variation from well to well, the technology does not lend itself to high throughput screening. Q: What are the dimensions of the plate for automation programing? A: Corning spheroid microplates adhere to the standard ANSI/SBS footprint dimensions for 96-well and 384-well microplate formats. A plate dimensions guide is provided with this user manual. Q: What are the plate dimensions with respect to imaging, e.g., the bottom thickness? A: bottom thickness for both 96-well and 384-well formats is 0.0875 mm. Please refer to the plate dimension guide for more information. Q: How do I change media when feeding? A: For a media change you need to remove a portion of the spent media from the wells and replace it with fresh media. To leave the spheroids undisturbed, we recommend performing this media change off-center using the sides of wells to remove and add media. A 50/50 media exchange will be the easiest. For example, to remove 50% of media from a 96-well format with a 200 μl starting volume, aspirate 100 μl of spent media from the wells, and replace with 100 μl of fresh media. For a full media change or wash step for either the 96-well or 384-well format, we recommend leaving behind a minimum of 10 µl per well. Use the plate dimension guide to program liquid handling instruments to be 2mm to 3 mm above the bottom of the wells and to be slightly off-center. Q: Will evaporation be an issue, like with the hanging drop technique? A: No. Evaporation is less of an issue because the spheroids are generated inside the wells. For longterm cultures, especially in the 384-well format, we recommend the use of breathable sealing tape (Corning Cat. No. 3345) during incubation periods. Q: What imagers have been validated for compatible use with Corning spheroid microplates? Manufacturer BioTek Instruments, Inc. Essen Bioscience Molecular Devices Nexcelom TTP Labtech Instrument Name Cytation cell imaging multi-mode reader IncuCyte ZOOM ImageXpress Micro XLS automated imaging system Celigo S image cytometer Acumen Cellista laser scanning image cytometer 4

Q: Are there any issues when reading plates while using fluorescent/colorimetric agents? A: No, Corning spheroid microplates are specifically designed for assay use. The plates feature optically clear, round bottom wells with a black opaque microplate body. The plate design also includes a unique well shield to minimize well-to-well cross-talk. We recommend using Promega CellTiter-Glo 3D Cell Viability Assay for cell proliferation and cytotoxicity assay screening. Q: Where can I find application notes for Corning spheroid microplates? A: Corning technical literature can be found online at www.corning.com/lifesciences/cellbasedassays References 1. Vinci, et al. 2012. Advances in Establishment and Analysis of Three Dimensional Tumor Spheroid-based Functional Assays for Target Validation and Drug Evaluation. BMC Biology 10:29. 2. Godoy P., et al. 2013. Recent Advances in 2D and 3D In Vitro Systems Using Primary Hepatocytes, Alternative Hepatocyte Sources and Non-parenchymal Liver Cells and Their Use in Investigating Mechanisms of Hepatotoxicity, Cell Signaling and ADME. Arch. Toxicol. 87(8):1315-1530. Pubmed/23974980. 3. Lai, et al. 2011. Neural Cell 3D Microtissue Formation is Marked by Cytokines Up-regulation. PLoS One 6(10):e26821. 4. Jun Y. 2013. 3D Co-culturing Model of Primary Pancreatic islets and Hepatocytes in Hybrid Spheroid to Overcome Pancreatic Cell Shortage. Biomaterials 34(15):3784-3794. 5. Astashkina, et al. 2012. A 3-D Organoid Kidney Culture Model Engineered for High-Throughput Nephrotoxicity Assays. Biomaterials 33:4700-4711. 6. Sasai Y. 2013. Next-Generation Regenerative Medicine: Organogenesis from Stem Cells in 3D Culture. Cell Stem Cell 12(5):520-530. For more specific information on claims, visit the Certificates page at www.corning.com/lifesciences. Warranty/Disclaimer: Unless otherwise specified, all products are for research use only. Not intended for use in diagnostic or therapeutic procedures. Corning Life Sciences makes no claims regarding the performance of these products for clinical or diagnostic applications. Corning Incorporated Life Sciences 836 North St. Building 300, Suite 3401 Tewksbury, MA 01876 t 800.492.1110 t 978.442.2200 f 978.442.2476 www.corning.com/lifesciences For additional product or technical information, please visit www.corning.com/lifesciences or call 1.800.492.1110. Outside the United States, call 978.442.2200. Worldwide Support Offices ASIA/PACIFIC Australia/New Zealand t 61 427286832 China t 86 21 3338 4338 f 86 21 3338 4300 India t 91 124 4604000 f 91 124 4604099 Japan t 81 3-3586 1996 f 81 3-3586 1291 Korea t 82 2-796-9500 f 82 2-796-9300 Singapore t 65 6572-9740 f 65 6861-2913 Taiwan t 886 2-2716-0338 f 886 2-2516-7500 For a listing of trademarks, visit us at www.corning.com/lifesciences/trademarks. All other trademarks in this document are the property of their respective owners. EUROPE France t 0800 916 882 f 0800 918 636 Germany t 0800 101 1153 f 0800 101 2427 The Netherlands t 31 20 655 79 28 f 31 20 659 76 73 United Kingdom t 0800 376 8660 f 0800 279 1117 All Other European Countries t 31 (0) 20 659 60 51 f 31 (0) 20 659 76 73 LATIN AMERICA e grupola@corning.com Brasil t (55-11) 3089-7400 f (55-11) 3167-0700 Mexico t (52-81) 8158-8400 f (52-81) 8313-8589 5 2014, 2015 Corning Incorporated. All rights reserved. Printed in U.S.A 6/15 CLS-AN-235 REV5