Towards a methodology of medical robot design



Similar documents
Medical Robotics. Classification of surgical systems

O-MS035. Abstract. Keywords: surgical robots, laparoscopic surgical robot, workspace, robot-assisted surgery, robot design

Dermarob: A Safe Robot for Reconstructive Surgery

CONCEPTUAL DESIGN OF A HYBRID ROBOT

Industrial Robotics. Training Objective

Stirling Paatz of robot integrators Barr & Paatz describes the anatomy of an industrial robot.

Autonomous Mobile Robot-I

Arrangements And Duality

Robotic for a cardiac surgeon

Pneumatically Driven Robot System with Force Perception for Minimally Invasive Surgery

Practical Work DELMIA V5 R20 Lecture 1. D. Chablat / S. Caro Damien.Chablat@irccyn.ec-nantes.fr Stephane.Caro@irccyn.ec-nantes.fr

Computer Animation. Lecture 2. Basics of Character Animation

Scooter, 3 wheeled cobot North Western University. PERCRO Exoskeleton

UOM Robotics and Industrial Automation Laboratory

Medical Robotics. Control Modalities

Robotic Surgery 12 years of robotic assisted surgery vs. conventional laparoscopic surgery

This week. CENG 732 Computer Animation. Challenges in Human Modeling. Basic Arm Model

INTRODUCTION. Robotics is a relatively young field of modern technology that crosses traditional

Force/position control of a robotic system for transcranial magnetic stimulation

Selecting Robots for Use in Drug Discovery and Testing

MODEL-SIZED AND FULL-SCALE DYNAMIC PENETRATION TESTS ON DAMPING CONCRETE

Constraint satisfaction and global optimization in robotics

Figure Cartesian coordinate robot

LEGO NXT-based Robotic Arm

Metrics on SO(3) and Inverse Kinematics

Photonic & Fiber Alignment Engines

Integration of a Robotic Arm with the Surgical Assistant Workstation Software Framework

INSTRUCTOR WORKBOOK Quanser Robotics Package for Education for MATLAB /Simulink Users

IRB 2600ID-15/1.85 Simple integration, high performance

Creating the Conceptual Design by Gathering and Analyzing Business and Technical Requirements

Al Akhawayn University in Ifrane. School of Science and Engineering. Design and Engineering of a Robot Arm

4.2 Free Body Diagrams

Introduction to Robotics Analysis, systems, Applications Saeed B. Niku

Leghe a memoria di forma come tecnologia di attuazione per la biorobotica

Design Aspects of Robot Manipulators

Introduction to Robotics Analysis, Systems, Applications

ROBOTICS 01PEEQW. Basilio Bona DAUIN Politecnico di Torino

Frequently Asked Questions

INTRODUCTION TO SERIAL ARM

A User Interface for a Seven Degree of Freedom Surgical Robot

Machine Tool Control. Besides these TNCs, HEIDENHAIN also supplies controls for other areas of application, such as lathes.

Considering Surgery for Fibroids? Learn about minimally invasive da Vinci Surgery

Robotic Surgery. Human and Robot strengths and weaknesses

Chapter. 4 Mechanism Design and Analysis

Definitions. A [non-living] physical agent that performs tasks by manipulating the physical world. Categories of robots

Introduction to Simulink & Stateflow. Coorous Mohtadi

5 WAYS TO EVEN GREATER EFFICIENCY

Operational Space Control for A Scara Robot

RobotWare 6 External Presentation

Facing Pancreatic Surgery? Learn about minimally invasive da Vinci Surgery

An inertial haptic interface for robotic applications

Applications > Robotics research and education > Assistant robot at home > Surveillance > Tele-presence > Entertainment/Education > Cleaning

Facing a Hysterectomy? If you ve been diagnosed with early stage gynecologic cancer, learn about minimally invasive da Vinci Surgery

Robot coined by Karel Capek in a 1921 science-fiction Czech play

Sandvik Mining and Construction France,

ABB Robotics, June IRB 1200 Overview. ABB Group August 21, 2014 Slide 1

Facing a Hernia Repair? Learn about minimally invasive da Vinci Surgery

INTRODUCTION TO ROBOTICS. Dr. Bob Williams, Ohio University

Considering Endometriosis Surgery? Learn about minimally invasive da Vinci Surgery

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

Geometry: Unit 1 Vocabulary TERM DEFINITION GEOMETRIC FIGURE. Cannot be defined by using other figures.

Robotic motion planning for 8- DOF motion stage

CALIBRATION OF A ROBUST 2 DOF PATH MONITORING TOOL FOR INDUSTRIAL ROBOTS AND MACHINE TOOLS BASED ON PARALLEL KINEMATICS

Sensory-motor control scheme based on Kohonen Maps and AVITE model

Selecting the Best Approach to Teach 3D Modeling to Technical College Engineering

Facing Hysterectomy? Learn why da Vinci Surgery may be your best treatment option for early stage gynecologic cancer

Intelligent Robotics Lab.

Positioning control in the Healthcare domain. Rob Albers, PhD Healthcare / Image Guided Therapy Systems March 25, 2015

Security Integrated System Using 3 DOF Robotic Lamps Along With SMS Alert

Simulation of Trajectories and Comparison of Joint Variables for Robotic Manipulator Using Multibody Dynamics (MBD)

Design-Simulation-Optimization Package for a Generic 6-DOF Manipulator with a Spherical Wrist

DESIGN AND PROTOTYPING OF A THREE DEGREES OF FREEDOM ROBOTIC WRIST MECHANISM FOR A ROBOTIC SURGERY SYSTEM

Products / Applications / Solutions. Your Intelligent Robotics Par tner

CIS009-2, Mechatronics Robotic Arms & Hands

LEONI ORION Precision patient positioning system Synchronicity with six degrees of freedom

Vector Algebra. Addition: (A + B) + C = A + (B + C) (associative) Subtraction: A B = A + (-B)

Measurement and Description of Dynamics Required for in vivo Surgical Robotics via Kinematic Methods

animation animation shape specification as a function of time

The Department of Engineering, has two Scorbot-ER VII robotic manipulators and one Controller- A. There are 4 components in the system:

Advances in Robotic Technology

Unit 1: INTRODUCTION TO ADVANCED ROBOTIC DESIGN & ENGINEERING

Interactive Motion Simulators

67273 EN V40/14 NOUVAG AG, all rights reserved Subject to change. Laparoscopic Hysterectomy Morcellator

Research-Grade Research-Grade. Capture

How To Perform Da Vinci Surgery

Robot Dynamics and Control

Animations in Creo 3.0

Robot soldering head 4900

Transcription:

Towards a methodology of medical robot design Laurence Nouaille Laboratoire Vision et Robotique Université d Orléans 1

Design of medical robots Medical Requirements Medical gesture analysis Specifications chart robotics constraints specific needs Designer helping tool Topological synthesis Classification robots morphologies medical domains choice of morphologies Dimensional synthesis robots dimensions choice of actuators 2

1- Study of specifications Otelo 2 TER Dermarob CT-Bot Hippocrate Padyc MC2E Drimis 3

1- Study of specifications Medical gesture follow up safety conditions Continue path planing without collision Dimensions : inaccessible safety zone Spherical movement around point contact probe skin Low powered actuators Inclination 35 mini, 60 Maxi Robot quickly removed from patient Movement tangent to skin cercle R= 25mm Minimum number of dof Translation perpendicular to skin -30mm to 10 mm Easily controllable structure Own rotation over than 90 Implementation Max Speed Max Strength Mobility v = 30 mm/s Fz = 20 N Light weight ω = 0,5 rad/s Compact Fast implementation Interchanging probes Specifications chart of Otelo 2 : tele-echography robot 4

2- Classification of medicals robots - 60 medical robots classified by : medical fields, mechanical structure, number of degree of freedom, kinematic configurations Laboratoire Robots Cinématique archi globale Porteur Poignet ddl config globale Acrobot Ltd Imperial College Acrobot anthropomorphe s s 6 6R Computer Motion Aesop Scara RCM passif s s RCM 6 PRRRRR Madhani Black Falcon RCM s RCM 8 RRPRRRRP Ortomaquet Caspar anthropomorphe s s 6 6R Brandt Zimolong Crigos parallèle Stewart p p 6 LSIIT CT-Bot parallèle p 5 RP LIRMM D2M2 bras passif s s s 5 PRRRP Intuitive Surgical Da vinci RCM actif parallélogramme s s RCM 6 RRPRRR LIRMM Dermarob Scara s s 6 PRRRRP LRP DRIMIS Outil intra -corporel s s 5 RRRRR Masuda Echographie abdomen hybride h p RCM 6 RRRRRP Salcudean Echographie artérielle Série s s RCM 6 PRRRRR Wendlandt Endo - plateforme parallèle Stewart p p 3 PPR Armstrong Healthcare EndoAssist RCM passif s s RCM 5 PRRRR Imperial college EndoBot RCM actif s 4 RRRP LIRM Hippocrate anthropomorphe s s 6 6R TIMC LER RCM actif poignet sphérique s RCM 3 RRP Israël Shoham Burman MARS parallèle Stewart p p 6 LRP MC2E RCM actif poignet sphérique s RCM 4 RRRP TIMC Neuromate anthropomorphe s s 6 RRRRRRR LVR Otelo RCM actif s RCM 6 PPRRRP TIMC PADyC ou RSP Scara passif s s s 6 PRRRRP Etats Unis PAKY RCM poulie courroie bras passif s RCM 7 RRP Finlay Armstrong Healthcare Path Finder anthropomorphe bras passif s s 6 6R ISS Robodoc Scara actif s s 5 RRPRR Auer Imperial College Roboscope parallèle p p 6 TIMC RPL hybride h p RCM 4 PPRRP Berkeley San Francisco RTW Hybride h RCM 6 RRRPRP Mitsuishi RUDS Série cartésien s 7 PPPRRRP Isis Robotics Surgiscope parallèle delta+rm p p 3 Vilchis TER 2 hybride h p RCM 6 PPRRRP LVR Teresa RCM actif s RCM 4 RRRP Polytec PI URS URS Evolution1 parallèle Stewart p p 6 6(SPS) Computer Motion Zeus Scara RCM passif s s RCM 4 PRRR 5

2- Classification of medicals robots - statistic analysis 13% allocation of robots by medical fields 7% 3% Neurochirurgie 14% Orthopédie Echographie 17% Chirurgie mini invasive 32% 14% Ponctions Radiothérapie Coloscopie Divers 6

2- Classification of medicals robots allocation of structures allocation of serial carriers 15% 24% Parallèles Séries Hybrides 61% 33 robots allocation of wrists 8% 12% RCM parallèles 44% 16 robots 14% 25% 31% Design of RCM robots 7% 21% anthropomorphe Scara divers Poignet à articulation passive poignet sphérique parallélogramme 25 robots 80% séries 29% 14 robots 29% poulie courroie commande 7

. 3- Designer helping tool ( d 3 3 < 500 mm + w < 5 kg) ( a < 1 mm) Parallel d : dimensions w : weight a : accuracy s : strength dof : degree of freedom A Choice of wrist Choice of the structure 3 d < 500 mm 3 w < 5kg Delta a < 1mm s < 100 N dof 4 Parallel No carrier Scara Anthropomorphic Hexapode Neuro-surgical Ponctions A Tele-echography Endoscopeholder mini-invasive Surgery Orthopaedic Neuro-surgical 8

. 3- Designer helping tool ( RCM 3 3 a < 2 mm) ( d > 500 mm ) compacity spherical wrist d : dimensions Choice of wrist RCM : Remote Center Motion a : accuracy RCM concourant Taking skin a < 2 mm P.A.P. mini-invasive Surgery 3 d > 500 mm 3 compacity Parallélogramme Parallelogram Spherical Circular guide mini-invasive Surgery Tele-echography Endoscope holder Tele-echography Endoscope holder 9

. 4- Conclusion and Perspectives To conclude : - Specifications design constraints and criteria - classification kwledge of the design of medical robots - Designer helping tool by a case-based design (CBD) method permits choosing morphologies The flow charts are verified by 51 robots of the classification The other robots are either particular cases or we don t have all the necessary information about them 10

4- Conclusion and Perspectives It is planned to : Dimensions - improve the bounds of the flow charts : perhaps by using fuzzy logic? - link the flow charts with computer assisted design 400^3 600^3 mm^3 - create a web site presenting all existing solutions - make a dimensional analysis applied to a new medical robot generic methodology of medical robot design 11