Fiber Optic Selector Guide for PLC & Serial Communication Networks

Similar documents
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Using installed Fieldbus Wiring to carry Ethernet Communications

OPT SERIAL TO FIBER OPTIC CONVERTER

F2400 FOM II Series Fiber Optic Modem Technical Manual

NC-12 Modbus Application

OPTICAL FIBER repeaters/ isolators

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Square D Model 6 Motor Control Centers

Perle 10/100 Ethernet Media Converters

TX2123 RS485 TO ETHERNET ADAPTOR

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

FlexPoint T1/E1 Copper to Fiber Line Driver

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

PCS0100en Persy Control Services B.V. Netherlands

M-series Virtual I/O Module 2

NetScanner System. Toronto: , Montreal: , Toll Free: ,

S-series SQ Controller

Product Information D23m Digital I/O System

Introduction Media converters

DeltaV SISnet Repeater

MLC TM Maximum Productivity and Versatility for Control without Compromise!

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Unidirectional Transmitter/ Receiver Units Introduction

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

Understanding Device Level Connection Topologies

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

SNAP-SCM-PROFI Communication Module

EDI Distributor Control Interface Wiring and Setup Instructions

PIEZOMETER AIRFLOW MEASURING RING

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

TrueAlarm Fire Alarm Systems

Automation Unit TM 1703 ACP Flexible automation and telecontrol

DeltaV Control Network Hardware

HARTING mcon 1000 Introduction and features

SCADA and Monitoring for Solar Energy Plant

Perle Fast Fiber to Fiber. Media Converters

Hirschmann Switch-Tuning: The new Gigabit OpenRail.

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Auxiliary equipment for communication with the EuroProt protective devices

Digital and Analog I/O

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Process Control and Automation using Modbus Protocol

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

ControlNet Fiber Media Planning and Installation Guide

PowerLogic Sub Meter Display (SMD and SMDOPN)

S-series Mass Connection Solutions

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

3500/22M Transient Data Interface

Loop-IP6702 TDMoEthernet

Technical Information POWER PLANT CONTROLLER

Module 1 Overview ControlLogix5000

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

EtherDevice Switch EDS-726 Series

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

IO-DIM6 6-Channel, Digital to Analogue Converters

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

HARTING econ 3000 Introduction and features

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Perle 10/100/1000 Ethernet Media Converter Module

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Perle Gigabit Fiber to Fiber Media Converters

MAJORSINE Power Inverter

c o m m u n i c a t i o n n e t w o r k s

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

AC Drive Solutions. We Engineer Uptime

Rack mounted telephone- and leased line modem for industrial applications

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Overview of the Cisco 2500 Series Access Server

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Understanding Device Level Connection Topologies

ABB RTU560A Series CMU & Modules

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

TAC I/NETTM MR-AHU-HP. Application Specific Controller

User Manual Revision English

SL42-xx SL42: Smart lighting controllers installation in the pole

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

TACTICAL FIBER OPTIC MODEMS U.S. Army and ANSI Standards

SCADA System Fundamentals

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Power over Ethernet technology for industrial Ethernet networks

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

LDG DTS-4/4R Desktop Coaxial Switch / Remote

My first Hirschmann: The SPIDER family of switches.

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

10/100/1000 Base-T to Gigabit Fiber Media Converter

Current Loop Application Note 1495

Transcription:

Fiber Optic Selector Guide for PLC & Serial Communication Networks Electrical Interface Modules Optical Interface Modules Power Supply Modules Self-Healing Ring Modules www.ultra-nspi.com

EOTec 2000 Self-Healing Ring (SHR) Networks Self-Healing Ring solution Achieve media redundancy without duplicate hardware Instantaneous switchover, in case of fiber failure, eliminates down time Snap-on upgrade to existing EOTec 2000 systems Local and remote alarm indication Automatic ring recovery after failed fiber link is restored The use of fiber optic technology to replace copper communications cable provides many advantages for industrial control applications. In addition to EMI/RFI immunity, the ability to run fiber optic cable through hazardous areas and long distance communications runs, another benefit of fiber is the ability to achieve media redundancy without incurring the cost of duplicate hardware systems. By using Ultra Electronics Self-Healing Ring (SHR) modules, a critical system can achieve uninterrupted communications in the event of a failure in the fiber optic communications lines. Constructing a self-healing ring network is as simple as adding the appropriate module(s) from the table below to an existing EOTec 2000 stack consisting of a PSM, EIM and two OIM s. In the case of Profibus, the self-healing ring function is integrated into the electrical interface module, so that only the EIM, PSM and two OIM s are required. When employing a self-healing ring configuration, the self-healing ring module is hardwired as Master. The electrical interface module must be set to 1 and the adjacent modules must be set to 2 and 3. Part Number Network Protocol Communications Data Rate Certifications Compatible Electrical Interface Modules 2C23 PROFIBUS-DP W/ 24VDC POWER ALL PROFIBUS DATA RATES BUILT INTO DEVICE 2C30 GE GENIUS, R-NET, MODICON REMOTE I/O, MODICON MODBUS PLUS, AB DH+, AB REMOTE I/O 9.6K TO 2M BAUD FM APPROVED CLASS 1 DIVISION 2 GROUPS A, B, C, D 2C02, 2C07, 2C, 2C14, 2C15, 2C29 2C30 - RELAY CONTACT RATING: 175VDC, 0.25A SWITCHING, 1A CONTINUOUS Ultra Electronics 2

EOTec 2000 Modular Fiber Optic Converters Transparent copper to fiber conversion Modular, flexible, scalable Real-time monitoring of fiber optic signal strength Protocol specific copper interface connections High Performance Deterministic Technology Full industrial operating temperature range (-40 to +85 C) FM approved Class I, Div 2, Groups A, B, C & D Standard 35 mm DIN rail mounting EOTec 2000 Fiber Optic Converters are designed to take traditional copper networks, convert them to fiber optic signals, and back again. Options support all popular fiber optic connectors (, SMA, SC). Problems such as ground loops, EMI/RFI noise and lightning strikes are eliminated. Fiber optic communication links can also be extended over much greater distances and support physical topologies not available with copper networks. Every fiber optic node requires Electrical Interface Module (EIM) Optical Interface Module (OIM) Power Supply Module (PSM) The Electrical Interface Module (EIM) is connected to the copper communication line. The module receives signals from the copper link, conditions them and makes the signal available to the backplane for conversion. The EIM also accepts signals from the backplane and transmits the signal to the attached copper link. The user must be sure to select the proper EIM for the copper protocol being converted. Considerations when selecting an Electrical Interface Module (EIM) What communication protocol is being converted? What is the baud rate? EIM Description and Part Number Baud Rate Physical Interface Copper Cable Termination Max. Devices/Copper Cable Length per Module GE Fanuc GE FANUC GENIUS BUS / REMOTE I/O 2C02 153.6K EXTENDED 32UNITS, 3500FT (1KM) Rockwell Automation RELIANCE R-NET / REMOTE I/O A-B DH & DH+ / REMOTE I/O A-B DH-485 2C07 2C 2C15 800K 57.6K, 115.2K AND 230.4K JUMPER SELECTABLE 19.2K BNC INTERNAL (75Ω) 1UNIT, 200FT (50M) 60 UNITS, 10,000FT (3KM) DH-485 SPECIFICATION 32 DEVICES/4000FT. Schneider MODICON REMOTE I/O MODICON MODBUS PLUS 2C14 2C29 1.54M 1.0M F-TYPE DB-9 PIN INTERNAL (75Ω) 20DB OF CABLE/TAP LOSS MODICON MODBUS PLUS SPECIFICATION Open Protocols RS-232/485 CONTROLNET DEVICENET 2C10 2C20 2C RS-232: 9.6K-115K RS- 485: 9.6K-230K HALF DUPLEX 5.0M 5K BNC 5-POS DNET TERMINAL INTERNAL (75Ω) RS-232: 1 UNIT, 50FT (15M) RS-485: 30 UNITS, 4000FT (1.2KM) CONTROLNET SPECIFICATION DEVICENET SPECIFICATION PROFIBUS 2C22 ALL DB-9 PIN PROFIBUS SPECIFICATION EIM s without internal termination can be used anywhere along a copper segment, whereas, modules with internal termination must be used at the end of copper segments only. 3 Ultra Electronics

EOTec 2000 Modular Optical Interface Modules Extend your network up to 30 km without a repeater SMA or fiber connectors Diagnostic Output (4-20mA) Up to 5 optical modules per modem Single/Multi-mode conversion possible or wavelength High/Low power setting Long lifetime - Class I LED The Optical Interface Module (OIM) accepts a signal from the backplane, converts it to an optical signal, and transmits this signal down the fiber optic cable. Conversely, the module will receive optical signals, condition the signal and make it available to the backplane. Considerations when selecting an Optical Interface Module (OIM) Is the fiber optic cable single mode or multi-mode? What types of connectors terminate the fiber optic cable? ( or SMA) What is the total loss on the fiber optic link? (This number must be less than the optical budget of the OIM selected) Is fiber link monitoring desirable? OIM Type and Part Number Optical Wavelength Baud Rate Optical Connector Type Optical Dynamic Range (db) Applicable Fiber Optic Cable Size/Type (µm) Diagnostic Output (4-20mA) 2E06* SMA 2D06* SMA MULTIMODE 2E07 2D07 2E10 2D10 2E09 23 17 23 17 2D09 2E19 18 2D19 18 SINGLE MODE 2E36 2D36 2E46 2D46 10 10 16 16 Safety: IEC 60825-1 Class 1 LED PRoducts, FDA CFR1040.10 & 1040.11 Each 2E/2D OIM module can be set for high power or low power. Default jumper setting for the optical transmit power is H (high); this setting should not be adjusted unless an optical overdrive situation occurs. Select position L (Low) in overdriving conditions. * t suitable for use with 2C20 ControlNet module Ultra Electronics 4

EOTec 2000 Power Supply Modules Universal Power Supply 85-240VAC, 50/60Hz and 85-5VDC Input (2A06/2A16) Discrete Diagnostic Output for Remote Control (2A16/2A18) Dual Power Supply Capability for Redundancy 24VDC Power Supply (2A08/2A18) UL/CSA listed (2A06/2A16) FM Approved for Class I, Div. 2, Groups A, B, C & D (2A08/2A18) The Power Supply Module (PSM) will accept the user s DC or AC power input and provide DC voltage to any module engaged to its backplane connector. PSM part numbers always begin with 2A, for example, 2A08 is our DC power supply. Considerations when selecting a Power Supply Module (PSM) Will AC or DC power be available at the installation site? Is redundancy required? Part Number Input Voltage Input Current (Max.) Input Fuse Alarm Relay CE Mark/UL FM Approval Class I, Div. 2 2A06 85-240VAC 50/60Hz & 85-140VDC 250mA / 2A16 85-240VAC 50/60Hz & 85-140VDC 250mA / 2A08 24VDC (±10%) 400mA / 2A18 24VDC (±10%) 400mA / ALARM RELAY CONTACT RATING: FORM-C, 175FDC, 1A CONTINUOUS Module Dimensions Ultra Electronics 5

Topologies Supported by the EOTec 2000 Product Family D A #1 POINT TO POINT Basic connection between two devices. #4 Redundant Pathway #2 C #3 B DAISY CHAIN Used for multiple drops along a line. AR Connects a central location to several branches. SELF-HEALING RING Achieve Media Redundancy Ultra Electronics Self-Healing Ring Modules Ultra Electronics Self-Healing Ring Module (SHR) provides media redundancy when utilized in each drop of a fiber optic ring network. Data is always routed on the shortest possible path to reduce propagation delay through the system. Ultra Electronics SHR accomplishes this by creating a virtual break in the ring at the link farthest from the originating node. Referring to the figure above, if de 1 is the originating node of a message, a virtual break will be created on the fiber link B or C (B is shown here). This virtual break is created on a packet-by-packet basis. The network behaves as if it were in a Daisy Chain, preventing the delivery of the same packet to any node twice. When fiber breaks actually occur, the SHR devices detect the break and a virtual break is no longer created since the real fiber break has done the function of putting the system into a Daisy Chain. The SHR automatically resets when the fiber path has been restored. Visible LED indicators in conjunction with relay contacts provide local and remote monitoring of the integrity of the fiber optic network. OPTICAL REPEATER Used to boost optical signals or for multimode single mode conversion. Weed Instrument Company, Inc. d/b/a Ultra Electronics, Nuclear Sensors & Process Instrumentation 707 Jeffrey Way, PO Box 300 Round Rock, TX 78680-0300 USA Phone: +1 5 434 2850, Fax: +1 5 434 2901 E-Mail: fiberop@ultra-nspi.com www.ultra-nspi.com Specifications subject to change without notice. Rev. 1, Pub: FSG-02.09