OWNERS MANUAL ECOJET

Similar documents
Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

1/3 HP Submersible Sump Pump with Vertical Float Switch

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP

Bottom Loading Water Dispenser

Electric Water Heater

Leak Detection System

4 in 1 Air Compressor

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

ClearView 100. Instruction Manual

TROUBLESHOOTING GUIDE

SunMaxx Solar Filling Station Operating Instructions

MINI-BRUTE II HOT WATER POWER WASHER MODEL# MBII

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

3 WATT LED SPOTLIGHT Model No. SLM

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Customer Support

100 Series Maxi Internal Filters. Instruction Manual

accidents which arise due to nonobservance and the safety information herein.

B-AIR BLOWER CUB POWER MODEL # CP-1

GAS SAFETY PRECAUTIONS

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Oil and Coolant Circulating Heating System. Model - OCSM

Mini-led spotlight with magnetic base

Owner s Manual & Safety Instructions

24.2L M.A.N. V12 Engine Module

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Ceiling Mount Air Handler Manual

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Battery Charger. Instruction Manual G

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Owner s Manual & Safety Instructions

CARING FOR YOUR WATER HEATER

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

IR Repeater. Operation Manual P8620

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Baths of Distinction Inc Carrier St St. Petersburg Florida USA Manufacturers of Classically Styled Vintage Bathtubs

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Instructions & Safety Information Models A220-20D and A220-20L Version 2

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

MODEL INSTALLATION INSTRUCTIONS

PAINT SPRAY GUN WASHER

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Get Me Cool Now Portable Air Conditioner User s Manual

Master Prep Professional

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Say Hello to Your Precision Cooker

The Storm 20-Gallon Wet/Dry Vac

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

INSTANT HOT WATER RECIRCULATING SYSTEM

, User s Manual

RT-200 HI-TEST ROPE TESTER

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

User Manual (English)

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

What you can expect from your Solar Hot Water System

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Advantium 2 Plus Alarm

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

3000W Power Inverter

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Micron-Master EL Series Fogger

NFC Communication Tray Model: HHX-IT3-Z

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

BroadBand PowerShield. User Manual

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Single Station Remote Alarm

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Installation, Maintenance, & Repair Series 4000B/LF4000B

United Technologies USER'S MANUAL. Split Type Room Air Conditioner

Mini Power Bank and Charger

AROS SMART WINDOW AIR CONDITIONER

Utility Distribution Systems

120Volt 60-70A ARC WELDER Rev

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Transcription:

OWNERS MANUAL ECOJET

ECO-JET Self-priming pumps ideal for supplying water for domestic and irrigation applications. 1) 1 Suction 2) 1 Discharge 3) Fill Plug 4) Drain Plug Fig. A 115V/60Hz Dear Customer, We congratulate you on the purchase of this quality product from Leader Pumps. 1. WARNING For its proper and trouble-free operation it is important to carefully read and follow these operating instructions and to fully observe all warnings. For safety reasons, people who are not familiar with these operating instructions should not use the pump, especially children under the age of 16. Please keep them away from the connected unit and during its installation. For the proper use of this garden pump it is essential to follow the given operating instructions provided by the manufacturer, before installing or servicing any pump, be certain pump power is disconnected to avoid any possible electric shock. Conformity with federal, State and local electric codes are mandatory. The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying sump, utility, effluent and all fountain pumps, pool pumps and other pond equipment. Consult a licensed electrician or your power company if in doubt.

The unit is supplied with a grounding conductor and a grounding type plug. To reduce risk of electric shock, connect only to a properly grounded electrical circuit equipped with an interrupter device. For all electrical connections, a separate line with a fuse or circuit breaker switch should be run from the meter, or breaker box, and properly grounded. Do not remove the grounding pin from the plug. This pump is not intended, nor has it been investigated, for use in pool areas. This pump is designed for 115- Volt - 60 Hz operation Be Sum the supply voltage is the same, This unit is not designed, nor intended, for the pumping of chemicals or corrosive liquids. This will shorten the life of the unit, expose user to possible personal harm, and void the warranty. Never pump gasoline or other flammable liquids or operate in the areas where flammable or explosive fumes are present as fire or explosion could occur. Unit features can be read on one side of its packaging. Piping must be protected against freezing which will cause damage and void the warranty. Do not run pump dry. If the pump is dry, damage will result and void the warranty. This pump must be primed before running. 2. PUMP FEATURES Built in handle for portability and ease of handling. Garden hose fitting included for discharge Suction lift capability to 25 ft. 3. USE AND APPLICATIONS This pump is intended to be used for irrigation of green areas, yards and vegetable gardens. For operating irrigators and sprinklers; suction of water from ponds, tanks, cisterns and fountains. 4. INSTALLATION AND STARTING OPERATION. Before putting the pump into operation it is absolutely necessary to carry out the following operations: a) The diameter of the suction and lines should correspond to the diameter of the connections of the pump housing (1") (see point 1 and 2 of previous page). For a suction height of over 12 ft. A suction hose with a greater diameter should be used. b) Fit the suction lines with the foot valve to the pump (at point 1), avoiding siphons, counter slopes and stand the pump on solid, flat level ground. c) Fit the delivery line at point 2 d) IMPORTANT Before operating for the first time, the pump must be filled to the top with fresh water through the delivery connection. The filling operation must be carried out very slowly. Wait few minutes until air comes out and fill again to the top.

e) Put into operation the pump and wait for the suction of the water. If nothing occurs after 2-3 minutes, switch off the pump, unplug and repeat the whole operation (from point d.) It will be necessary to recheck pump s installation. During checking operations always remember to take out the plug. Possible causes may be a leak in suction line letting air in, faulty foot or check valve, suction line not completely submerged or damaged, too high suction lift, clogged suction filter or closed outlet. For all electrical connections, a separate line' with a fuse switch should be run from the meter, or breaker box and properly grounded. Open all shut-off devices in the pressure system of the pump (e.g.) spray nozzle or faucet), so that air can escape during the printing operation, The temperature of the water must never exceed 35 C or 100 F. Always unplug the pump before working on it, in case of maintenance. Do not place or submerge the pumps into water. Always use a suction line with an installed check valve or foot valve; this will allow ease priming when starting the pump. 5. SAFETY INFORMATION Always disconnect electricity to the unit before handling it. Do not lift the unit by the power cord. Do not pump heated liquids. Max. Temperature 35 C or 100 F. Conformity with local and State electric codes is mandatory. Consult a licensed electrician or your power company if in doubt. Power cables as well as extension cables may be done using same cord type. Take care that connections are done in areas protected from flooding. Before installation please check for} any damage to the unit (e.g. power cable and plug). 6. WARRANTY The ECOJET series pumps are warranted to the user against defective material and workmanship under normal use for a period of 12 months from the date of purchase by the purchaser. Replacement liability in all events is limited to the replacing or repairing at LEADER's sole discretion of any or parts which are defective in material or workmanship.

Proof of purchase is required on all claims in the form of invoice copy, sales ticket, etc. APPLICATION: Warranty covers only properly installed and maintained units. Warranty is limited to application at normal temperature (up to 35 C or l00 F) and pumping fresh water. SITUATIONS NOT COVERED: this limited warranty does not cover product failures resulting from the following: handling flammable liquids, solvents, strong chemicals or severe abrasive solutions; handling liquids hotter than product rating Normal wear Commercial or industrial use running pumps dry ADMINISTRATION: Warranty claims must be made by returning the defective LEADER pump freight paid along with proof of purchase. Please call (803) 797-5002 for a "RMA number before returning to: PUMPS AMERICA INC Customer Service Dept. 3226 Benchmark Drive, Ladson, South Carolina 29456 - U.S.A. All items returned will be inspected to determine the cause of failure before warranty is approved. Before returning your unit to our store and to insure that your defective pump will be covered by warranty - call us at (803) - 797-5002. INSTALLATION and/ or REMOVAL CHARGES: Warranty does not cover any costs associated with the installation or removal of products subject to warranty claims. If products were damaged in transit please file a claim with the carrier..

DISCLAIMER: Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, and should not be relied upon and are not part of the contract for sale. Seller s and manufacturer s only obligation, and buyer s and user s only remedy, shall be for the manufacturer to either replace / or repair at the manufacture s sole discretion the LEADER product as described above. Neither seller nor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising from any cause whatsoever, no matter based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them, Before using, the buyer and user shall determine the suitability of the product for the intended use, and assumes all risks and liability whatsoever in connection therewith. The warranty and remedy described in this limited warranty is an EXCLUSIVE warranty and remedy and IN LIEU of any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED, including but not limited to any implied warranty of MERCHANTABILITY or FITNESS for a PARTICULAR PURPOSE. This warranty gives buyer and user specific legal rights, and buyer and user may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply you. All warranties are voided if alterations are made to the elect1ic cord or plug not in accordance with Safety Information ( nr..) or if the unit is wholly or partially disassembled beyond the instructions in the troubleshooting section.

10. OPERATING PROBLEMS PROBLEM CAUSE CORRECTIVE ACTION Pump does not prime See point nr. 4 Operation information The pump does not run The pump runs but does not deliver 1. Not plugged in 2. Thermal overload or Amperometric protection tripped due to: a) Overheating (the pump ran with hot water or ran dry) b) Shaft blocked c) Impeller blocked 1. Air in the pump housing 2. Air bubbles in the suction line 3. Pump not primed 1. Check the plug. 2. Remedy to : a) Press the amperometric protection reset button on the pump (only ECOJET models 120 and 130) or wait until thermal protector switches back on after adequate cooling time allowed. b) Unplug the pump and with a screwdriver twist the rear shaft side. c) Unplug the pump, disassemble the pump and clean it and remove the causes of the overload / overheating switch off. 1Unplug the pump. Take out discharge line; shake the pump and suction pipe. Fill up pump housing with water ; fit discharge line and switch on the Pump 2. Verify that suction line and fittings are fixed tight and that foot valve is correctly mounted on suction line. 3. Read priming instructions We expressly point out that in accordance with product liability law - we are not liable for damage caused by our equipment if it is due to improper repair or if parts have been exchanged not using our original Leader parts or parts approved by us and if the repairs were not carried out by a Leader Service centre or an authorized electrician. 11. APPROVAL AND CONFORMITY MARKS

3226 BENCHMARK DRIVE LADSON, SC 29456 USA TEL: 1-843-824-6332 FAX: 1-843-797-3366