ATMOR 100 Series Models: 100, 100V, 101, 101V, 101P, 101PV, 102, 102V, 102P, 102PV

Similar documents
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

ELECTRIC INSTANTANEOUS WATER HEATER

SERVICE MANUAL Order No.WH0911S001V0

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

INFRARED QUARTZ WALL HEATER

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Shower Handbook (Also covers 650 chrome variant)

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

SF15K SF05KSS, SF10KSS

HERZ-Thermal Actuators

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

3 IN 1 BATHROOM HEATER

Operators manual Basic water heater

CARING FOR YOUR WATER HEATER

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

High kw Electric Tankless Water Heater Troubleshooting Guide

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Reverse Cycle Inverter Split System Air Conditioner

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

Please also see 10 golden rules for correct Saniflo installation on

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Chill 4 Hole Bath Shower Mixer

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

ELECTRIC CENTRAL HEATING FLOW BOILER

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Isotemp Basic, Slim/B & Slim Square

1. Description. 2. List of Accessories included A B C F G H

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

Triac Printed Circuit Board Replacement

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Overheating limit control

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Electric Instantaneous. Water Heaters. Service manual

Portable Air Conditioner

USER S MANUAL HSC-24A

OPERATING INSTRUCTIONS

Operating Instructions. Room temperature controller

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

For Models #6-5001, #6-7501, # & #10-12K1

Cara electric shower Installation and operating instructions

Geyser-R Heat pump water heater Installation manual

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

WE-350 Series ¼ Turn Electric Actuator

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

ClearView 100. Instruction Manual

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

INSTALLATION INSTRUCTIONS BL-8704

This section gives you some helpful information and tips on running your home and the equipment in it.

Aquamax Australia Pty Ltd ABN

SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER SHC 2.5 SHC 4. English. English

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

PWC-500/1000/1010/1500

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Accessory Manual Ventilation Section Model Comfort Circle

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Safety & Environmental Protection Services Guidance Note

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

5W LED Energy Saver PIR Bulkhead

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

SMD Rework Station TABLE OF CONTENTS

CALIFORNIA PROPOSITION 65 WARNING:

Economy Combo Heat Press Manual Model No.: ECH-800

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

LUCCI AIRFUSION QUEST II CEILING FAN

SWIMMING POOL HEAT PUMP

Transcription:

Installation and Operation Guide ATMOR 100 Series Models: 100, 100V, 101, 101V, 101P, 101PV, 102, 102V, 102P, 102PV Instant hot water heater provides endless supply of hot water while significantly conserving energy and water Reset Pump www.atmor.net P.N. 000000

Dear Customer, Thank you for purchasing Atmor instantaneous water heater: High energy efficiency Slim design Flow controlled 2

Safety 1. Carefully read the instructions below. 2. Check the data on data sticker and compare it with your mains voltage. 3. The heater must be installed and put into operation by a licensed specialized. Do not switch ON the heater when it obviously frozen in. The heater operates at a minimum water flow rate of 1.6L/Min. For direct connection to the water tank, the heater must have a minimum of 1.0m below the water tank. Separate electric circuits must be provided for the heater via a double pole linked switch with a minimum contact gap of 3mm in both poles and must be permanently connected to the direct main current supply. The switch must be readily accessible and clearly identifiable and out of reach of person using a fixed bath or shower. The use of a plug and socket is not recommended. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been Using Double Pole ELSD For Phase and neutral,optional Single Pole ELSD Technical data For technical characterizes, please refer to the appliance Data sticker: MODEL: 100 220-240V A.C. 3.0-3.6kW 50Hz IP25 Made in China Max. Water Pressure: 600 kpa(6 bar) Min. Water Pressure: 30 kpa (0.3 bar) Rated Pressure: 0 kpa (0 bar) SERIAL No. Sample Data Sticker Model Weight Dimensions With pump 2.3 kg 381 (H) * 215 (W) * 77(D) mm Without pump 1.9 kg WARNING! "Earth" Led (Blue), indicate the product properly grounded to protect from electrocution. In case the EARTH led is OFF switch OFF the incoming power supply and call proffesional electrician. 1. The appliance must be earthed. 2. If any of the following conditions occur, immediately switch off the mains and contact Service. Never attempt to repair the unit yourself. If the heater begins to make an odd noise, smell or smoke. ELSD and heater lamp does not light up. Water temperature can not be controlled. If the heater shows signs of a distinct change in performance. If found water leakage from inside. 3

Installation instruction Note: The control knobs are integral parts of the cover do not attempt to remove them. Unscrew the bottom & top A& B (fig.1) retained screws and lift the cover from the back plate. Use the back plate as a template and mark the fixing holes. The heater position should be 1.5 meter from the bathroom floor. (fig.2) Drill the holes: 2 Options: (Fig 3 Or Fig. 4) and insert the wall plugs. Insert the cables through the cable entry of the heater. Fit the heater to the wall. (Fig 3 Or Fig 4) To mount the shower accessory, mark 2 screws points for positioning the slider rail set beside the heater. It is recommended the top of the portion with the top of the heater. Remove the terminal cover from the mounting terminal and screw the mounting to position. Close the cover. Insert the shower holder and soap Tray. Close the cover. 1. For the correct size of wire conductor corresponding to different electrical loading, please refer to table 1. 2. The built in ELSD will automatic cut off the power supply in case there is a current leakage as low as 15mA. To ensure correct operation of the ELSD, DO NOT installs this product if the line voltage is lower than 175V. 3. The thermostat will automatic cut off the power if it has sensed an abnormal rise in showing water temperature. Only qualified technicians are allowed to reset the thermal cut- out built inside the appliances. Fig.1 1.5o m B A Fig.2 Option 1 Option 2 Fig.3 Fig.4 4

Plumbing connection Warning: The outlet of the heater acts as a vent and MUST NOT be connected to any TAP, CONTROL VALVE OR FITTING TO THE WATER OUTLET. INCORRECT INSTALLATION 1. Connect the stop valve to the water inlet with rubber washer. Use correct tools to tighten and be careful not to break the plastic nut. 2. Insert Mesh filter washer then connect the incoming water piping end to the stop valve (1/2 BSP). 3. Connect the PVC hose and hand shower to the outlet of the heater; be sure to put in the rubber washer. 4. Hook the hand shower to the slider Rail Holder and adjust to your ideal position. Fig.5 Danger: Outlet on the Left size of unit. THE WATER INLET AND OUTLET MUST BE INSTALLED CORRECTLY, OTHERWISE THE HEATER CAN NOT FUNCTION. CORRECT INSTALLATION DO NOT USE PLUMBING CEMENT ON CONNECTION. IF NECESSARY, USE ONLY THREAD OR SEALING TAPE. Turn on the water mains to drain out all plumbing dirt and to fill up the heater tank Check for any water leakage. (IMPORTANT: This step will prevent damage to the Heating element). Outlet Inlet Fig.6 5

Electrical connection This appliance must be EARTHED. The EARTH continuity conductor of the electrical installation must be effectively connected electrically to all exposed metal parts of other appliances in the room in Which the heater installed. SWITCH OFF at mains before carrying out any electrical work. Refer to the Electrical Loading Table (Table 1) for the correct cable size. DO NOT install this product if the line voltage is lower than 175V. Fig.5 1. Use double coated flexible cable having nominal crosssectional area between 4 and 6 mm 2. (IEC/EN 60335-1). 2. Lead the power cable from the circuit breaker to a ON/OFF double bipolar switch outside the bathroom, then lead a cable connected to terminal block inside the unit (fig.5). Note: Conduit entry can only from rear. 3. Connect the cable to terminal block and fully tighten them (insure no cable insulation is trapped under the screws) as follow: (fig.5) BROWN or RED FOR LIVE (L) BLUE or BLACK for NEUTRAL (N) GREEN or Green/ Yellow for EARTH ( ). The cable clamp must be used to secure the cable. (fig.6) 4. Check the wiring connection is tightens and correct then close the front cover. When close back the front cover, please take note the below procedure: To ensure the correct position, turn the temperature knob insert to OFF position as shown in fig.8. (At the heater base). To install the front cover, turn the temperature control knob to OFF position to align with the knob insert as shown in fig.8 (At the front cover). For pump models, the same align procedure is apply to both pump speed VR insert And pump knob. 5. Fix back the screws A & B. (fig. 7) Do not switch on the electricity supply until the cover has been fitted. Fig.6 B A Fig.7 6 Fig.8

Testing Testing THE HEATER TANK MUST BE FILLED UP WITH WATER BEFORE TURN ON THE ELECTRICITY SUPPLY. THIS IS TO PREVENT ANY DRY BURNT DAMAGE TO THE HEATING ELEMENT. 1. Turn on the water supply (J) then wait until the water flow through the Hand shower. 2. Switch on the electrical supply and the Green Led (ELSD) lamp will turn on (F). 3. Turn on the temperature control knob (E) to ON, the red LED (Heater) lamp will turn on; the hot water will come out in a few seconds. The higher the temperature indicator position, the hotter is the shower. 4. The shower might not be enough even at the maximum position if the incoming water supply from the mains is too cold or the flow too high. In this case, you can adjust the water inflow in order to get the desired showering temperature. 5. Check the Built-in ELSD as follow: Press the TEST button (B), the unit should trip and cut off the power supply, All leds lamps should light off. 6. Press the RESET button (C), the unit should resume normal function, Green LED lamp should light on. If the above mentioned procedures prevail, the ELSD is functioning in normal condition. 7. If shower accessory is available, the height and the direction of the shower holder is adjustable. For pump model: 8. Turn on the pump control knob (D) to test run the pump. If the shower is not hot enough, you can adjust the knob (A) to reduce the pump speed until you get the desired shower temperature. For power ON/OFF model: 9. After turn ON supply (J) and press power ON/OFF button (G) then wait until the water flow through the hand shower. Reset Pump J A B C D E F G H 7

Maintenance Read the section WARNING first. Test the ELSD regularly Turn on the electricity (G) and water supply (J), the green ELSD lamp (F) will light up. If the temperature control knob (E) is in ON position; the red heater lamp will light up also. Press The ELSD test knob (B), the ELSD and heater lamp should go off. Press the reset knob (C) to resume the electricity supply. If the ELSD or heater lamp does not go off when you press the ELSD test knob, SWITCH OFF the main supply and contact service. NEVER try to repair the unit by yourself. The users shall test the built in ELSD at least once a month to ensure the heater is safe to use. Clean the filter Remove the filter by turn it anti clockwise and flush it with water to remove any trapped Sediments. Fitting and cleaning the Shower head Warning: Metallic / chromed hose and conductive control valve shall not be used. (Apply for products installed in Malaysia only) Fit the two end brackets to the Rod. Place the brackets with rod onto the wall and mark the position on the two screw holes. Fit the end brackets, holder and rod onto the wall with the wall plugs and screw provided. Fit the flexible hose to the shower head. Connect the flexible hose with shower head to the heater using the rubber sealing washer. Place the shower head in the holder. The heater is now ready to be fitted to the electrical supply. Note: The shower head must be periodically clean to ensure no blockage occurred. Do not use thinner, alcohol, petrol or any other organic solutions to clean the set. 8

Electrical connection Table 1: Electrical Loading Table Wattage Amperage (AMPs) Cable Size 1Ø 220V 1Ø 230V 1Ø 240V (mm 2 ) 2kW 9.1 8.7 8.3 2.5mm 2 3.3kW 13.6 13.0 12.5 2.5mm 2 3.5kW 15.0 14.3 13.7 2.5mm 2 4.5kW 20.5 19.5 18.8 2.5-4.0mm 2 5.5kW 25 23.9 22.9 4-6mm 2 6.5kW 29.5 28.2 27.0 4.0-6.0mm 2 Wattage Amperage (AMPs) Cable Size 1Ø 220V 1Ø 230V 1Ø 240V (mm 2 ) 7.5kW 34.1 32.6 31.3 4.0-6.0mm 2 8.5kW 38.6 37.0 35.4 2 6.0-10.0mm 9.5kW 43.2 41.3 39.6 6.0-10.0mm 2 3Ø 220V 3Ø 230V 3Ø 240V 8.5kW 12.9 12.3 11.8 2.5 2 9.5kW 14.4 13.7 13.2 2.5 2 Wiring Diagram - With Pump +24V 0V Speed Control Power, Pump & 2P ELSD Control PCBA Power, Pump SV & 2P ELSD Control PCBA 9

Electrical connection Wiring Diagram - Without Pump 10

Part List Terminal Block PCBA DP ELSD (Optional SP) Pump SP Tank Assy Main PCBA Control Flow Switch Assy Outlet Inlet Reset Pump Reset ELSD+PUMP Model Cover ELSD Cover Cover 11

Trouble shooting SYMPTOM POSSIBLE CAUSE SOLUTION Water no! hot enough Water too hot Heater switch Off during use Too much waler fiowing through the heater Reduction In tha ambient temperature Water Pressure below of 1.0bar Electrical Mallunction Not enough Water flowing through the heater Increase in the ambient temperature Interruption of mains electrical supply ELSD trip, possible earth leakage Reduce the flow rate of the waler via the outlet tap. Switch to higher temperature setting. Check if the mains stop valve is fully open and that the there are no other restriction in the supply line. Have the Heater unit check by a qualified eiectrician or contact your local authorised distributor. Increase the flow rate via the outlet tap Switch to lower temperature setting Check incoming power supply, MCB, switches and supply cabling. Check earth leakage and reset ELSD If problem persists, call your local authorised distributor for assistance. Water ceases to flow Water temperature varies from hot to cold during use No hot water despite fully open hot water faucet Blockage of spray head, twisted or blocked flexible shower hose. No water supply. Water pressure has dropped below min. level. No electrical power The activation flow rate needed to turn on the heating element has not been reached. Clean or replace sprayheed, check for free passage of water through hose. Replace as necessary. Check water supply, stop valve Open? and no blockage. Increase hot water supply, Check the circuit breaker and check voltage at the wiring block. Clean filter screen Turn circuit breaker off Open hot valve to release pressure from the unit. Turn circuit breaker on. 12 www.atmor.net