SEIHTP1, SEIHTM1 Installation Manual. Issue SEIHTM1 Model Shown STROM- ELECTRICAL.

Similar documents
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SF15K SF05KSS, SF10KSS

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

MAC FAUCETS. Owner s Manual. Models: FA444

High kw Electric Tankless Water Heater Troubleshooting Guide

3 IN 1 BATHROOM HEATER

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

CARING FOR YOUR WATER HEATER

Design Utility Lever Thermostatic Bath Shower Mixer

SunMaxx Solar Filling Station Operating Instructions

ELECTRIC INSTANTANEOUS WATER HEATER

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

SERVICE MANUAL Order No.WH0911S001V0

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

2-SLICE COOL TOUCH TOASTER

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Operators manual Basic water heater

INFRARED QUARTZ WALL HEATER

Overheating limit control

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Ceiling Mount Air Handler Manual

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

INSTALLATION & TECHNICAL MANUAL

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Please also see 10 golden rules for correct Saniflo installation on

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

What you can expect from your Solar Hot Water System

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

MODEL INSTALLATION INSTRUCTIONS

Electric Instantaneous. Water Heaters. Service manual

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Oil and Coolant Circulating Heating System. Model - OCSM

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Shower Handbook (Also covers 650 chrome variant)

Geyser-R Heat pump water heater Installation manual

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Meaco 30L and Meaco 40L dehumidifier instruction manual

Solar Hot Water System Operation Manual

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

Aquamax Australia Pty Ltd ABN

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

ALL IN ONE. Heat Pump Water Heater

1/3 HP Submersible Sump Pump with Vertical Float Switch

Stainless Steel Single and Dual Circulation Kits

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

Installation Instructions S

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Troubleshoot resources for homeowner

Electric Water Heater

Tankless Water Heater

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Thermo Siphon Solar Systems

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Version: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Assembly and instructions

Home comfort: water heating

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

ThermoStar Refrigeration Air Dryers

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

HOT WATER HEAT PUMP MANUAL FOR ADVICE, REPAIRS AND SERVICE: CALL (AUSTRALIA) (NZ)

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Chill 4 Hole Bath Shower Mixer

Mira Extra Bath and Thermostatic Shower Control

Super Cascade Filtration Systems (CE)

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

Continuous Flow Water Heaters

COMPRESSED AIR DRYER

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Moda. Instructions for use. Breville Customer Service Centre Australian Customers. Cordfree Kettle. New Zealand Customers

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Artisan Thermostatic Bath Shower Mixer

Transcription:

SEIHTP1, SEIHTM1 Installation Manual Issue 1 2015 SEIHTM1 Model Shown STROM- ELECTRICAL www.strom-electrical.com

INTRODUCTION Thank you for purchasing your Strom-Electrical instaneous water heater, we are very proud of our products and we are sure that you will be happy with the years of service you get from your model. This product has been designed to operate at mains pressure and deliver instant hot water. SPECIFICATION MODEL SEIHTP1 SEIHTM1 Body Material High Quality Stainless Steel Tap Head Material High Strength ABS Plastic High Quality Stainless Steel Voltage 220-240v Rated Frequency 50-60Hz Power 3.0kW Rated Current 13.6A Recommended Cable Size 1.5mm 2 Thermal Cut-Out 50 o C Dry Heating Protection 70 o C Hot Water Flow 2L - 5L Per Minute IP Rating IP25 Working Pressure 0.04-0.4mPa IMPORTANT NOTICE For your satisfaction and safety, read all instructions before installing or using this instant hot water tap. This particular unit is not intended for commercial use. This appliance should be connected to mains water feed. This water heater may not be suitable for children or some elderly operators unattended due to the risk of scalding should the flow of water not be controlled properly.

Your Strom-Electrical water heater MUST be installed and maintained regularly by a qualified professional in accordance with current electrical and plumbing regulations. If the chloride content exceeds 200ppm a filtration system should be fitted, failure to do so may invalidate your warrenty. This device has been designed for internal use only, if the system may be exposed to frost please drain down the system completely, and DO NOT attempt to use the device if you suspect it is frozen. Always ensure that the flow temperature is not excessive before use. If the water is too hot please increase the flow at the tap and wait for the temperature to reduce. As part of the product maintenance regularly clean the filter washer provided at the tap, failure to do so may reduce your flow rate over time. The tap is not designed for modification in any way, please do not fit anything to the tap unless otherwise recommended. When comissioning the water valve should be adjusted to increase or decrease the water flow to the tap, this in turn will control the temperature of water from the tap, slower increase the temperature, faster decreases the temperature. Each unit is tested at our factory before its departure, a little residual water is normal, and the product should be flushed through before use. Never try to operate this device if your water supply is blocked or turned off, doing so could cause premature failure of your device. Any damage to the wiring or integrity of your device should be assessed by a qualified electrician, and the device should not be used until the unit or wiring has been repaired. The minimum water supply available at the point of install is 0.02mPa. BEFORE INSTALLATION This installation must only be taken by a qualified electrician and installed to all relevent national and local electrical and plumbing regulations. Failure to do this could render the install both illegal and dangerous. Before installationation please ensure the following: 1. Your Strom-Electrical appliance is intact, and the fittings are supplied & complete. 2. Please make sure the mains power supply, water pressure, earthing condition, and cabling reach the standards required for installation as required by all relevent regulations & laws. 3. The appliance must be properly earthed in accordance with all current regulations and laws. 4. If the unit is not to be used for a prolonged period of time please drain down and isolate the electrical supply of the product. 5. Position the unit upright with all plumbing connections at the bottom of the unit. 6. During the installation please test water flow is achieved at the tap before connecting the power supply. If the heater is activated without water supply the unit may be damaged.

PRODUCT STRUCTURE SEIHTP1 SEIHTM1 WIRING SCHEMATIC This diagram is provided for your reference of the internal wiring of your Strom-Electrical water heating product. No attempt should be made to change the internals of your water heater, doign so may be dangerous and will invalidate your warranty. Your product MUST always be wired by a qualified electrician in accordance with all the relevent regulations and laws in place at the time of installation.

PRODUCT SITING Installation of your electrical water heater can be achieved in two ways: 1. With the supply cable underneath the counter top. 2. With the supply cable above the counter top. INSTALLATION Once your product has been sited in accordance with the diagrams above please secure your tap with the supplied plastic spacer and nut, and finally connect your product to the mains supply using a 1/2 tap hose to the base of the tap. Fit the supplied filter between the tap and the hose. We suggest fitting an isolation valve and ball valve before the tap to facilitate removal of the tap and servicing. REMEMBER: Before turning off the water supply to the tap you must isolate its electric supply, operating the tap while there is no water can cause premature failure and invalidate your warrenty. DO NOT turn on your electric supply at this time.

COMISSIONING 1. Please flush the system through completely by pulling the flow control towards: Do this for 20 seconds to allow the system to flush and fill compeltely. 2. Turn on the power supply to the tap. 3. Push the flow control backwards towards: the indicator light on the tap should illuminate. 4. With the flow control roughly half way backwards please adjust the ball valve to achieve the desired flow rate and temperature. Slowing the flow rate down will increase the temperature at this position, increasing the flow rate will reduce the temperature. 5. Turn the device to the OFF position on the tap. 6. Your tap is now ready for use. GENERAL USE Operation of this tap is simple: Pulling the flow control towards: will give you cold water, the further forwards you turn the flow control the faster the cold water will come out of the tap. Pushing the flow control backwards towards: will give you hot water, the further backwards you turn the flow control the faster the flow rate will become, but the cooler the water will be. By pushing the control only slightly backwards the flow rate will be very low but the water temperature will be very hot. REMEMBER: This product if used incorrectly can scald, if the water is too hot increase the flow rate by turning the flow control further backwards, if it is too cool reduce the flow rate by throttling the flow control forwards. Leaving the tap in the central OFF position turns the flow rate and the heater off. REMEMBER: If you are to leave this product unattended for long periods of inactivity please isolate the electric supply, and drain the product down. MAINTENANCE Always turn off the power supply before servicing your unit To ensure a long lasting and efficient product we recommend the following maintenance regime: Periodically remove scale and dirt that may build up at the aerator of the faucet or in the sprinkler. The filter washer supplied and fitted should be cleaned to reduce any debris build up and ensure good consistent flow rates.

TROUBLESHOOTING SYSTEM ISSUE LIKELY CAUSE POSSIBLE SOLUTION No Hot Water Is Supplied When The Tap Is Turned On. Inlet flow rate is less than 1L/Min Increase the inlet flow rate There is no power supply Please call an electrician to inspect your installation Outlet Temperature Is Too Hot Flow rate is too low Increase the flow rate at the tap Outlet Temperature Is Too Cold Flow rate is too high Reduce the flow rate at the tap Flow Rate At The Tap Is Low Filter washer clogged Please clean the filter washer Water Flow At The Tap Is Uneven Or Spraying Sprinkler at the tap is blocked or impeeded Remove limescale from sprinkler and clean. GUARANTEE Your Strom-Electrical water heater is guaranteed for a period of 12 months from the date of purchase. The unit is only guaranteed if the water heater has been installed and maintained in accordance with these instructions. Full guarantee information can be found at: www.strom-electrical.com/guarantee The guarantee specifically excludes: Corrosion by incorrect maintenance of the water heater, or incorrect installation. Limscale build up. Consequential losses, including labour charges and damages to fittings. Any water heater that has not been maintained and installed in accordance with this manual.

www.strom-electrical.com STROM- ELECTRICAL www.strom-electrical.com